Home > Panasonic > Blood Pressure Monitor > Panasonic Ew Bu35 Operating Instructions

Panasonic Ew Bu35 Operating Instructions

Here you can view all the pages of manual Panasonic Ew Bu35 Operating Instructions. The Panasonic manuals for Blood Pressure Monitor are available online for free. You can easily download all the documents as PDF.

Page 21

HOW TO USE
English
20
Storage
1. Unplug the AC adapter from the AC outlet.
2. Unplug the plug from the main unit.
5. Place the tube into the cuff.
Do not wrap the tube around the main 
 
●
unit. It may get damaged by excessive 
force on the tube.
Be careful not to bend the tube.
 
●
3.  Close the hook and loop fastener of the 
cuff.
1
23
4.  Fold the spare cuff material inside the cuff.
6. Place the main unit and the cuff into the 
accessory pouch.
To prevent from unexpectedly operations 
 
●
during...

Page 22

APPENDIX
English
21
Care and maintenance
Do not apply excessive force to the instrument or drop the instrument.
 
●
   - Doing so may cause damage.
Measurements may be affected if the device is used close to televisions, microwave 
 
●
oven, X-ray equipment or other devices with strong electrical fields. Measure blood 
pressure at a sufficient distance from such devices or switch them off.  
If the instrument is stored at temperatures below the freezing point, do not use it 
 
●
immediately. Leave it in a...

Page 23

APPENDIX
English
22
Explanation of rating plate symbols
Read the operating instructions carefully before use.
Protection against electric shock    Type BF applied part (Blood pressure monitor)
Protection against electric shock    Class II equipment (AC adapter)
AC
DC 
BU35.indb   222011/06/14   14:28:29 

Page 24

APPENDIX
English
23
Q&A
Q Why are the blood pressure values measured at home different from those measured at the doctor’s office?
A Blood pressure varies 24 hours a day. In addition, it can change greatly depending on the weather, your mental state, exercise, etc. .
In particular, there is the phenomenon of “White coat hypertension” at doctor’s offices, where 
the blood pressure measured in a doctor’s office is higher because of stress or worry.
In addition, if the blood pressure measured at home is...

Page 25

APPENDIX
English
24
Q The  indicator does not light when an arm is moved.
A The 
 indicator is a function to notify you that your arm is bent or to indicate extra loads 
on the cuff.
Therefore, it may not indicate motions (bending an arm slightly, etc.) that do not affect the cuff. 
If you are concerned about the result, retry the measurement.
Q&A (continued)
Troubleshooting
Display Status before error Cause and solution
 
is displayed. The indication disappears in the 
middle of the operation. (the...

Page 26

APPENDIX
English
25
Troubleshooting (continued)
SymptomPossible cause
Systolic or diastolic blood pressure value 
is high or low. The position of the cuff is higher or lower than your 
 
●
heart when measuring.
Cuff is not wrapped correctly.
 
●
You moved or talked during measurements. (See page 
 
●
13.)
Value is different from that measured by 
the doctor. Blood pressure varies in response to minute changes 
 
●
in your mental state, such as your reaction to a doctor’s 
presence.
Sit quietly for 4 to 5...

Page 27

APPENDIX
English
26
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class 
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed 
to provide reasonable protection against harmful interference in a residential 
installation. This equipment generates, uses and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause 
harmful interference to...

Page 28

For questions or assistance with your blood pressuremonitor, call us at 1-800-338-0552. 
Panasonic Corporation of North AmericaOne Panasonic Way 1H-1 Secaucus, NJ 07094
1-800-338-0552 (USA only) for questions and comments
No.1 EN, SP   ¢ žÝæ§ £  
© Panasonic Electric Works Co., Ltd. 2011 1
W9030BU35201
Issued date: 2011-06-14 Printed in China
Impreso en China
BU35.indb   292011/06/14   14:28:43 
Start reading Panasonic Ew Bu35 Operating Instructions

Related Manuals for Panasonic Ew Bu35 Operating Instructions

All Panasonic manuals