Have a look at the manual Panasonic DLP Projector PT-DZ770U PT-DZ770UL Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
[NETWORK] menu ENGLISH - 91 Settings ▶■[Network status] page Click [Status] → [Network status]. The current network setting status is displayed. ▶■[Access error log] page Click [Status] → [Access error log]. The error log on the WEB server is displayed such as access to the pages that do not exist or access with unauthorized user names or passwords. ▶■[Access log] page Click [Status] → [Access log]. The log such as user name accessed to the WEB control page, accessed IP address, accessed time is displayed. Note z [Access error log]/[Access log] will display the recent few thousand accesses/requests. May be unable to display all information when many accesses/requests are made at one time. zWhen [Access error log]/[Access log] exceeds a certain amount, old information will be erased. zConfirm [Access error log]/[Access log] periodically .
[NETWORK] menu 92 - ENGLISH Settings ▶■[Basic control] page Click [Projector control] → [Basic control]. (1) (2) (4) (6) (3) (5) (1) [POWER] Switches the power on/off. (2) [SHUTTER] Switches between use or not use of the shutter function. (3) [OSD] Switches between on (display)/off (no display) of the on-screen display function. (4) [SYSTEM] Switches the system method. (5) On-screen display of the projector Displays the same content as the on-screen display of the projector. The settings of the menu can be checked or changed. This is displayed even when the on-screen display function is set to off (hide). (6) [INPUT SELECT] Switches the input signal. ▶■[Detail control] page Click [Projector control] → [Detail control]. (2) (3) (4) (5) (6) (7) (8) (1) (1) Control of the projector The projector is controlled by clicking the buttons in the same way as the buttons on the remote control. After the projector is controlled, the on-screen display of the projector on the right side of the control page is updated. (2) [LENS] Adjusts the projection lens. (3) [TEST PATTERN] Displays the test pattern. (4) [GET OSD] Updates the on-screen display of the projector at the right of the control page. (5) [SUB MEMORY] Switches the sub memory. (6) [SYSTEM DAYLIGHT VIEW] Switches to system daylight view settings. (7) [FREEZE] Temporarily pauses the image. (8) [SIDE BY SIDE] Displays two different input signals simultaneously.
[NETWORK] menu ENGLISH - 93 Settings ▶■[Network config] page Click [Detailed set up] → [Network config]. ▶z Click [Network config] to display the [CAUTION!] screen. ▶zThe current settings are displayed by pressing the [Next] button. ▶zThe following setting change screen is displayed by pressing the [Change] button. (1) (2) (3) (4) (5) (6) (7) (8) (1) [PROJECTOR NAME] Enter the name of the projector. Also enter the host name if it is required when using a DHCP server, etc. (2) [DHCP ON]/[DHCP OFF] To enable the DHCP client function, set to [DHCP ON]. (3) [IP ADDRESS] Enter the IP address when not using a DHCP server. (4) [SUBNET MASK] Enter the subnet mask when not using a DHCP server. (5) [DEFAULT GATEWAY] Enter the default gateway address when not using a DHCP server. (6) [DNS1] Enter the DNS1 server address. Permissible characters for the entry of DNS1 server address (primary): Numbers (0 to 9), period (.) (Example: 192.168.0.253) (7) [DNS2] Enter the DNS2 server address. Permissible characters for the entry of DNS2 server address (secondary): Numbers (0 to 9), period (.) (Example: 192.168.0.254) (8) [Back]/[Next] Click the [Back] button to return to the original screen. The current settings are displayed by pressing the [Next] button. Click the [Submit] button to update the settings. Note zWhen you use the “Forward” and “Back” functions of your browser , a warning message “Page has Expired” may appear. In that case, click [Network config] again since the following operation will not be guaranteed.
[NETWORK] menu 94 - ENGLISH Settings ▶■[Adjust clock] page Click [Detailed set up] → [Adjust clock]. (1) (2) (3) (4)(5)(6) (7) (1) [Time Zone] Select the time zone. (2) [Set time zone] Updates the time zone setting. (3) [NTP SYNCHRONIZATION] Set to [ON] to adjust the date and time automatically. (4) [NTP SERVER NAME] Enter the IP address or server name of the NTP server when you set to adjust the date and time manually. (To enter the server name, the setup of the DNS server is required.) (5) [Date] Enter the date to be changed. (6) [Time] Enter the time to be changed. (7) [Set date and time] Updates the date and time settings. Note zThe replacement of the battery inside the projector is required when the time goes out of alignment right after correcting the time. Please consult your dealer . ▶■[Ping test] page You can check whether the network is connected to the E-mail server, POP server, DNS server, etc. Click [Detailed set up] → [Ping test]. (1) (2) (3) (4) (1) [Input IP address] Enter the IP address of the server to be tested. (2) [Submit] Executes the connection test. (3) Example of display when the connection has succeeded (4) Example of display when the connection has failed
[NETWORK] menu ENGLISH - 95 Settings ▶■[E-mail set up] page E-mail address set in advance for use when there is a problem or when the usage time of a lamp reaches a set value. E-mail can be sent to (maximum two locations). Click [Detailed set up] → [E-mail set up]. (1) (2) (3) (4) (5) (6) (1) [ENABLE] Select [Enable] to use the E-mail function. (2) [SMTP SERVER NAME] Enter the IP address or the server name of the E-mail server (SMTP). To enter the server name, the setup of the DNS server is required. (3) [MAIL FROM] Enter the E-mail address of the projector. (Up to 63 characters in single byte) (4) [MEMO] You can enter information such as the location of the projector that notifies the sender of the E-mail. (Up to 63 characters in single byte) (5) [MINIMUM TIME] Change the minimum interval for the temperature warning mail. The default value is 60 minutes. In this case, another E-mail will not be sent for 60 minutes after sending the temperature warning mail even if it reaches the warning temperature. (6) [INTAKE AIR TEMPERATURE] Change the temperature setting for the temperature warning mail. A temperature warning mail is sent when the temperature exceeds this value. (8) (7) (7) [E-MAIL ADDRESS 1]Enter the E-mail address to be sent. (8) Settings of the conditions to send E-mail Select the conditions to send E-mail. [MAIL CONTENTS]: Select either [NORMAL] or [SIMPLE]. [ERROR]: An E-mail message is sent when an error occurred in the self-diagnosis. [LAMP1 RUNTIME]: An E-mail message is sent when the remaining lamp on time for the lamp 1 has reached the value set at the right field. [LAMP2 RUNTIME]: An E-mail message is sent when the remaining lamp on time for the lamp 2 has reached the value set at the right field. [INTAKE AIR TEMPERATURE]: An E-mail message is sent when the air intake temperature has reached the value set at the above field. [PERIODIC REPORT]: Place a check mark on this when E-mail is to be sent periodically. It will be sent on the days and time with the check mark.
[NETWORK] menu 96 - ENGLISH Settings ▶■[E-mail set up] page (continued) (3) (2) (1) (1) [E-MAIL ADDRESS 2] Enter the E-mail address to be sent when two E-mail addresses are to be used. Leave it blank when two E-mail addresses are not to be used. (2) Settings of the conditions to send E-mail Select the conditions to send E-mail to the second E-mail address. [MAIL CONTENTS]: Select either [NORMAL] or [SIMPLE]. [ERROR]: An E-mail message is sent when an error occurred in the self-diagnosis. [LAMP1 RUNTIME]: An E-mail message is sent when the remaining lamp on time for the lamp 1 has reached the value set at the right field. [LAMP2 RUNTIME]: An E-mail message is sent when the remaining lamp on time for the lamp 2 has reached the value set at the right field. [INTAKE AIR TEMPERATURE]: An E-mail message is sent when the air intake temperature has reached the value set at the above field. [PERIODIC REPORT]: Place a check mark on this to send E-mail to the second E-mail address periodically. It will be sent on the days and time with the check mark. (3) [Submit] Update the settings.
[NETWORK] menu ENGLISH - 97 Settings ▶■[Authentication set up] page You can set the authentication items when POP authentication or SMTP authentication is necessary to send an E-mail message. Click [Detailed set up] → [Authentication set up]. (1) (2) (3) (4) (5) (6) (7) (8) (1) [Auth] Select the authentication method specified by your Internet service provider. (2) [SMTP Auth] Set when the SMTP authentication is selected. (3) [POP server name] Enter the POP server name. Allowed characters: Alphanumerics (A to Z, a to z, 0 to 9) Minus sign (-) and period (.) (4) [User name] Enter the user name for the POP server or the SMTP server. (5) [Password] Enter the password for the POP server or the SMTP server. (6) [SMTP server port] Enter the port number of the SMTP server. (Normally 25) (7) [POP server port] Enter the port number of the POP server. (Normally 110) (8) [Submit] Update the settings.
[NETWORK] menu 98 - ENGLISH Settings ▶■Contents of mail sent ▶z Example of E-mail sent when E-mail is set The following E-mail is sent when the E-mail settings have been established. === Panasonic projector report(CONFIGURE) === Projector Type : DZ770 Serial No : SH1234567 ----- E-mail setup data ----- TEMPERATURE WARNING SETUP MINIMUM TIME at [ 60] minutes interval INTAKE AIR TEMPERATURE Over [ 45C / 113F ] ERROR [ OFF ] LAMP1 RUNTIME [ OFF ] at REMAIN [ 400] H LAMP1 RUNTIME [ OFF ] at REMAIN [ 200] H LAMP2 RUNTIME [ OFF ] at REMAIN [ 400] H LAMP2 RUNTIME [ OFF ] at REMAIN [ 200] H INTAKE AIR TEMPERATURE [ OFF ] PERIODIC REPORT Sunday [ OFF ] Monday [ OFF ] Tuesday [ OFF ] Wednesday [ OFF ] Thursday [ OFF ] Friday [ OFF ] Saturday [ OFF ] 00:00 [ OFF ] 01:00 [ OFF ] 02:00 [ OFF ] 03:00 [ OFF ] 04:00 [ OFF ] 05:00 [ OFF ] 06:00 [ OFF ] 07:00 [ OFF ] 08:00 [ OFF ] 09:00 [ OFF ] 10:00 [ OFF ] 11:00 [ OFF ] 12:00 [ OFF ] 13:00 [ OFF ] 14:00 [ OFF ] 15:00 [ OFF ] 16:00 [ OFF ] 17:00 [ OFF ] 18:00 [ OFF ] 19:00 [ OFF ] 20:00 [ OFF ] 21:00 [ OFF ] 22:00 [ OFF ] 23:00 [ OFF ] ----- check system ----- MAIN CPU BUS [ OK ] FAN [ OK ] INTAKE AIR TEMPERATURE [ OK ] OPTICS MODULE TEMPERATURE [ OK ] AROUND LAMP TEMPERATURE [ OK ] LAMP1 REMAIN TIME [ OK ] LAMP2 REMAIN TIME [ OK ] LAMP1 STATUS [ OK ] LAMP2 STATUS [ OK ] SHUTTER [ OK ] INTAKE AIR TEMP.SENSOR [ OK ] OPTICS MODULE TEMP.SENSOR [ OK ] AROUND LAMP TEMP.SENSOR [ OK ] BATTERY [ OK ] COLOR WHEEL [ OK ] COVER OPEN [ OK ] FILTER UNIT [ OK ] AIR FILTER [ OK ] (Error code 00 00 00 00 00 00 00 00) Intake air temperature : 26 degC / 78 degF Optics module temperature : 39 degC / 102 degF Around lamp temperature : 30 degC / 86 degF PROJECTOR RUNTIME 1 H POWER ON 1 times LAMP1 ON 1 times LAMP1 ECO 0 H LAMP1 NORMAL 0 H LAMP1 REMAIN 1999 H LAMP2 ON 1 times LAMP2 ECO 0 H LAMP2 NORMAL 1 H LAMP2 REMAIN 1999 H -------- Current status --------- MAIN VERSION 1.00 NETWORK VERSION 1.00 SUB VERSION 1.00 LAMP STATUS LAMP1=ON LAMP2=ON INPUT SIGNAL RGB1 --- 0.00kHz / 0.00Hz REMOTE2 STATUS DISABLE ----- Wired Network configuration ----- DHCP Client OFF IP address 192.168.10.100 MAC address 70:58:12:00:00:00 Wed Jan 18 11:42:37 2012 ----- Memo -----
[NETWORK] menu ENGLISH - 99 Settings ▶zExample of the E-mail sent for an error The following E-mail is sent when an error has occurred. === Panasonic projector report(CONFIGURE) === Projector Type : DZ770 Serial No : SH1234567 ----- check system ----- MAIN CPU BUS [ OK ] FAN [ OK ] INTAKE AIR TEMPERATURE [ OK ] OPTICS MODULE TEMPERATURE [ OK ] AROUND LAMP TEMPERATURE [ OK ] LAMP1 REMAIN TIME [ OK ] LAMP2 REMAIN TIME [ OK ] LAMP1 STATUS [ OK ] LAMP2 STATUS [ OK ] SHUTTER [ OK ] INTAKE AIR TEMP.SENSOR [ OK ] OPTICS MODULE TEMP.SENSOR [ OK ] AROUND LAMP TEMP.SENSOR [ OK ] BATTERY [ OK ] COLOR WHEEL [ OK ] COVER OPEN [ OK ] FILTER UNIT [ FAILED ] AIR FILTER [ OK ] (Error code 04 00 00 00 00 00 00 00) Intake air temperature : 26 degC / 78 degF Optics module temperature : 39 degC / 102 degF Around lamp temperature : 30 degC / 86 degF PROJECTOR RUNTIME 1 H POWER ON 1 times LAMP1 ON 1 times LAMP1 ECO 0 H LAMP1 NORMAL 0 H LAMP1 REMAIN 1999 H LAMP2 ON 1 times LAMP2 ECO 0 H LAMP2 NORMAL 1 H LAMP2 REMAIN 1999 H -------- Current status --------- MAIN VERSION 1.00 NETWORK VERSION 1.00 SUB VERSION 1.00 LAMP STATUS LAMP1=ON LAMP2=ON INPUT SIGNAL RGB1 --- 0.00kHz / 0.00Hz REMOTE2 STATUS DISABLE ----- Wired Network configuration ----- DHCP Client OFF IP address 192.168.10.100 MAC address 70:58:12:00:00:00 Wed Jan 18 11:42:37 2012 ----- Memo -----
[NETWORK] menu 100 - ENGLISH Settings ▶■[Change password] page Click [Change password]. (1) (2) (3) (1) [Administrator] Used to change the setting of the [Administrator]. (2) [User] Used to change the setting of the [User]. (3) [Next] Used to change the setting of the password. ▶z[Administrator] account (1) (2) (3) (4) (5) (6) (7) (1) [Account] Displays the account to change. (2) [Current] [User name] Enter the user name before the change. (3) [Current] [Password] Enter the current password. (4) [New] [User name] Enter the desired new user name. (Up to 16 characters in single byte) (5) [New] [Password] Enter the desired new password. (Up to 16 characters in single byte) (6) [New] [Password(Retype)] Enter the desired new password again. (7) [OK] Determines the change of password.