    Have a look at the manual Panasonic DLP Projector PT-DZ21KU PT-DS20KU PT-DW17KU Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							[NETWORK] menu
    ENGLISH - 141
    Settings
    ▶z[User] account
    (1)
    (2)
    (3)
    (5) (4)
    (1) [Account]
    Displays the account to change.
    (2) [New][User name] Enter the desired new user name. (Up to 16 
    characters in single byte)
    (3) [New][Password] Enter the desired new password. (Up to 16 characters 
    in single byte)
    (4) [New][Password(Retype)] Enter the desired new password again.
    (5) [OK] Determines the change of password.
    ▶z[Change password] (For user rights)
    Only the change of password is enabled under the user rights.
    (1)
    (2)
    (4) (3)
    (1) [Old Password]
    Enter the current password.
    (2) [New Password] Enter the desired new password. (Up to 16 
    characters in single byte)
    (3) [Retype] Enter the desired new password again.
    (4) [OK] Determines the change of password.
    Note
     zT
    
    o change the account of the administrator, you must enter the [Current] [User name] and [Password]. 
    						
    							Lamp/Temperature/Filter Indicators 
    142 - ENGLISH
    Maintenance
    Lamp/Temperature/Filter Indicators
    Managing the indicated problems
    If a problem should occur inside the projector, the lamp indicators ///, the 
    temperature indicator , and the filter indicator  will inform you by lighting or flashing.
    Check the status of the indicators and manage the indicated problems as follows.Attention
     z When switching of
    
    f the power to deal with problems, make sure to follow the procedure in “Switching of f the 
    projector” (
     page 51).
    Note
     z Check the status of the power supply with the power indicator . (
     page 49)
    /DPSLQGLFDWRU/$03!
    3RZHULQGLFDWRU
    21*67$1%
    						
    							Lamp/Temperature/Filter Indicators
    ENGLISH - 143
    Maintenance
    ▶■Temperature indicator
    Indicator 
    status Lighting in red Flashing in red
    (2 times) Flashing in red
    (3 times)
    Status Warm-up status Internal 
    temperature 
    is high. 
    (WARNING)Internal temperature is high 
    (standby mode)
    The cooling fan has 
    stopped.
    Cause
     z Did you turn on the 
    power when the 
    room temperature 
    was about 0°C 
    (32°F)? zIs the air intake/exhaust port blocked?
     zIs the room temperature high?
     zIs the filter indicator  not lit?
    ―
    Solution
     zW
     ait at least five 
    minutes in the 
    current status.
     z Install the unit 
    in a location 
    with an ambient 
    temperature of 
    0°C (32°F) to 45°C 
    (1
    
    13°F)
    *1.
     zRemove any objects that are blocking the air 
    intake/exhaust port.
     zMove the projector to a location with an 
    ambient temperature of 0°C (32°F) to 45°C 
    (1
     13°F)
    *1 and a humidity of 20% to 80% (no 
    condensation).
     z C
    
    lean the air filter unit or replace it. (
     page 144)
     z T
     urn the  switch to 
     (
     page 51), 
    and consult your 
    dealer.
    *1: When using the projector at high elevations (1 400 m (4 593 ft) – 2 700 m (8 858 ft) above sea level), the operating environment 
    temperature will be 5°C (41°F) lower than the maximum limit.
    When using a smoke cut filter
    , the temperature will be 0°C (32°F) to 35°C (95°F). However, it cannot be used at high elevations.
    Note
     zIf the temperature indicator  is still lit or flashing after taking the preceding measures, ask your dealer 
    to repair the unit.
    ▶■ Filter indicator 
    Indicator 
    status Lighting in red
    Flashing in red
    Status The filter is clogged.
    The temperature inside or outside the projector is abnormally high. The air filter unit is not 
    attached.
    Cause
     z Is the air filter unit 
    dirty? zIs the air intake/
    exhaust port 
    blocked? zIs [HIGH 
    
    ALTITUDE 
    MODE] set 
    correctly?
     z Is the air filter unit 
    attached?
    Solution
     z Clean the air filter 
    unit or replace it. 
    (
     page 144)
     zRemove any objects 
    that are blocking the 
    air intake/exhaust 
    port. zWhen using the 
    projector at high 
    elevations 1
    
      400   m 
    (4   593   ft) – 2   700   m 
    (8
      858   ft) sea 
    level, set [HIGH 
    ALTITUDE MODE] 
    (
     page 100) to [ON].
     z Do not use the 
    projector at high 
    elevations 2
    
      700   m 
    (8
     
    858   ft) or higher 
    above sea level.
     z Attach the air filter 
    unit.
    Note
     z If the filter indicator  is still lit or flashing after taking the preceding measures, ask your dealer to 
    repair the unit.
     z If the filter is clogged, only one lamp may light even when [LAMP
     SELECT] is set to [QUAD], [TRIPLE], or 
    [DUAL]. Cleaning the air filter unit or replacing it with a new one will turn of f the indicator
    
    . 
    						
    							Maintenance/replacement 
    144 - ENGLISH
    Maintenance
    Maintenance/replacement
    Before maintaining/replacing the unit
     zMake sure to turn of
    f the power before maintaining or replacing the unit. ( pages 48, 51)
     zW
    
    hen switching off the projector, make sure to follow the procedures in “Switching off the projector” (
     page 51).
    Maintenance
    ▶■ Outer case
    Wipe off dirt and dust with a soft, dry cloth.
    ▶z
    If the dirt is persistent, soak the cloth with water and wring it thoroughly before wiping. Dry of
    f the projector 
    with a dry cloth.
    ▶z Do not use benzene, thinner
    
    , or rubbing alcohol, other solvents, or household cleaners. Doing so may 
    deteriorate the outer case and peel off the paint.
    ▶z When using chemically treated dust cloths, follow the instructions written on its packaging.
    ▶■ Lens
    If dirt or dust accumulates on the surface of the lens, it will be enlarged and projected onto the screen.
    Wipe off dirt and dust from the front surface of the lens with a soft clean cloth.
    ▶z
    Do not use a cloth that is fluf
    
    fy, dusty, or soaked with oil/water.
    ▶zSince the lens is fragile, do not use excessive force when wiping the lens.
    Attention
     z The lens is made of glass. Impacts or excessive force when wiping may scratch its surface. Please handle with 
    care.
    ▶■ Air filter unit
    Perform maintenance of the air filter unit in the following cases.
    ▶z
    The air filter is clogged with dust, causing the filter replacement message to appear on the screen and the 
    filter indicator  to light in red.
    1) Remove the air filter cover .
    ▶zUse a Phillips screwdriver to turn the air filter cover screw counterclockwise until it turns freely
    , and then 
    remove the air filter cover .
    Air filter cover f\
    ixing screw
    Air filter cover
    2) Pull out the air filter unit.
    ▶zRemove the air filter unit frame at the front side (with the lens) from the tab of the projector body while 
    slightly pressing the center and pull out in the direction of the arrow
    , and then remove the frame at the 
    opposite side from the tab.
    ▶z After pulling out the air filter unit, remove large foreign objects and dust from the air filter unit compartment 
    and the air intake port of the projector body if there are any
    
    .
    Tabs on the 
    projector body Tabs on the 
    projector body
    Air filter unit com\’partment and 
    the projector’\f air intake port
    Air filter unit
     
    Attention
     zT
    
    ake care not to touch the radiator fin when removing dirt or dust. 
    						
    							Maintenance/replacement
    ENGLISH - 145
    Maintenance
    3) Clean and dry the air filter unit.
     zCleaning the air filter unit
    (i)
     
    Soak the air filter unit in cold or warm water and then lightly rinse it.
    •
    
    ▶
    Do not use cleaning tools such as brushes.
    •
    
    ▶
    When rinsing, hold the frame of the air filter unit without putting strong pressure on the filter unit.
    (ii)
    
     
    Rinse the unit two to three times using fresh water each time.
    •
    
    ▶
    Insufficient rinsing may result in odors.
     zDrying the air filter unit
    •
     
    Let the unit naturally dry of
     f in a well-ventilated place where there is little dust and the unit is protected 
    from direct sunlight.
    •
     
    Do not dry using drying devices such as dryers.
    4) Attach the air filter unit to the projector .
    ▶zThe air filter unit has no dif ference between top and bottom, but is two-sided. Match the protrusion position 
    of the air filter with the grooves on the projector body.
    ▶z Hook the air filter unit frame at the exhaust port side to the two tabs of the back side of the projector
    ’
    
    s air 
    filter unit compartment and perform Step 2) in the reverse order to attach.
    •
     
    Confirm that the tabs of the air filter unit compartment of the projector body are hooked to the air filter unit 
    frame.
    Tabs on the project\ior body
    Tabs on the project\ior body
    Protrusion o\f the a\iir \filter unit
    Protrusion o\f the a\iir \filter unit
    Groove on the proje\ictor body
    Groove on the proje\ictor body
    5) Attach the air filter cover to the projector and use a Phillips screwdriver to tighten 
    the air filter cover screw
    .
    ▶zPerform Step  1) in the reverse order.
    Attention
     z After washing the air filter unit, dry it thoroughly before attaching it back to the projector
    . 
    
    Attaching a wet unit 
    will cause an electric shock or malfunction.
     z Do not disassemble the air filter unit.  
    						
    							Maintenance/replacement 
    146 - ENGLISH
    Maintenance
    Note
     zT
    
    ake care not to touch the radiator fin when removing dirt or dust.
     zMake sure that the air filter unit is properly attached before using the projector
    . If it is not properly attached, the 
    projector will suck in dirt and dust causing a malfunction.
    –
    
    ▶
    If you use the projector without attaching the air filter unit, the message appears on the projection screen for 
    approximately 30 seconds.
     zReplace the air filter unit with a replacement filter unit (Model No.: ET
    -EMF510) if it is damaged or if the dirt 
    does not come of
    
    f even after washing.
     zAir filter replacement is recommended after cleaning the unit two times.
     zThe dust-proof properties may be reduced after each cleaning.
    Replacing the unit
    ▶■ Air filter unit
    If dirt does not come off even if the unit is maintained, it is time for the unit to be replaced.
    The replacement filter unit (Model No.: ET-EMF510) is an optional accessory. To purchase the product, 
    consult your dealer.
    ▶■Replacement of the air filter unit
    Attention
     z
    Make sure to turn of
    
    f the power before replacing the air filter unit.
     zWhen replacing the unit, make sure that the projector is stable. Perform the replacement in a safe place where 
    the projector will not be damaged even if you drop the air filter unit.
    1) Remove the air filter cover
    .
    ▶zUse a Phillips screwdriver to turn the air filter cover screw counterclockwise until it turns freely
    , and then 
    remove the air filter cover .
    Air filter cover f\
    ixing screw
    Air filter cover
    2) Pull out the air filter unit.
    ▶zRemove the air filter unit frame at the front side (with the lens) from the tab of the projector body while 
    slightly pressing the center and pull out in the direction of the arrow
    , and then remove the frame at the 
    opposite side from the tab.
    ▶z After pulling out the air filter unit, remove large foreign objects and dust from the air filter unit compartment 
    and the air intake port of the projector body if there are any
    
    .
    Tabs on the 
    projector body Tabs on the 
    projector body
    Air filter unit com\’partment and 
    the projector’\f air intake port
    Air filter unit
     
    Attention
     zT
    
    ake care not to touch the radiator fin when removing dirt or dust. 
    						
    							Maintenance/replacement
    ENGLISH - 147
    Maintenance
    3) Attach the replacement filter unit optional accessory (Model No.: ET-EMF510) to the 
    projector .
    ▶zThe air filter unit has no dif ference between top and bottom, but is two-sided. Match the protrusion position 
    of the air filter with the grooves on the projector body.
    ▶z Hook the air filter unit frame at the exhaust port side to the two tabs of the back side of the projector
    ’
    
    s air 
    filter unit compartment and perform Step  2) in the reverse order to attach.
    •
     
    Confirm that the tabs of the air filter unit compartment of the projector body are hooked to the air filter unit 
    frame.
    Tabs on the project\ior body
    Tabs on the project\ior body
    Protrusion o\f the a\iir \filter unit
    Protrusion o\f the a\iir \filter unit
    Groove on the proje\ictor body
    Groove on the proje\ictor body
    4) Attach the air filter cover to the projector and use a Phillips screwdriver to tighten 
    the air filter cover screw
    .
    ▶zPerform Step  1) in the reverse order.
    Attention
     z When switching on the projector
    
    , make sure that the air filter unit is installed. If it is not properly attached, the 
    projector will suck in dirt and dust causing a malfunction.
    –
    ▶
    If you use the projector without attaching the air filter unit, the message appears on the projection screen for 
    approximately 30 seconds.
    Note
     z The replacement cycle of the air filter unit varies greatly depending on the usage environment.
    ▶■ Lamp unit
    The lamp unit is a consumable component. See “When to replace the lamp unit” ( page 148) for details about 
    the replacement cycle.
    Consult your dealer to purchase a replacement lamp unit (Model No.: ET -LAD510 (1 bulb), ET-LAD510F (4 bulbs)).
    It is recommended that you request a qualified technician to replace the lamp unit. Consult your dealer .
    Attention
     z Do not replace the lamp unit when it is hot. (W
    
    ait at least one hour after use.)
    ▶■Checking the lamp unit to be replaced
    Check the status of the lamp indicators ///.
     z
    The lamp unit corresponding to the lamp indicator that is lit in red is required to be replaced.
    ▶■ Notes on the replacement of the lamp unit
    ▶z
    A Phillips screwdriver is necessary when replacing the lamp unit.
    ▶z
    Since the luminous lamp is made of glass, it may burst if dropped or hit with a hard object.
    Please handle with care.
    ▶zDo not disassemble or modify the lamp unit.
    ▶zWhen replacing the lamp unit, be sure to hold it by the handle because its surface is pointed and its shape 
    is protruded.
    ▶zThe lamp may be burst. Replace the lamp unit carefully so that the broken pieces of the lamp glass will not 
    scatter
    
    . When the projector is mounted on the ceiling, do not make the replacement directly under the lamp 
    unit or put your face near it.
    ▶z The lamp contains mercury
    
    . When disposing of used lamp units, contact your local authorities or dealer for 
    correct methods of disposal.
    Attention
     z Use only specified lamp units.
    Note
     z The model numbers of accessories and optional components are subject to change without notice. 
    						
    							Maintenance/replacement 
    148 - ENGLISH
    Maintenance
    ▶■When to replace the lamp unit
    The lamp unit is a consumable component. Since its brightness gradually decreases over time, it is necessary 
    to replace it regularly. The estimated duration before replacement is 2 000 hours. However, this may be 
    shortened depending on individual lamp characteristics, usage conditions, and the installation environment. 
    Therefore, it is strongly recommended that a replacement lamp unit be prepared. 
    The unit can damage the 
    projector if it has not been replaced after 2
      000 hours of usage. Thus, the lamp automatically turns off after 
    approximately ten minutes.
    If the cumulative operating time of all 4 lamp unit bulbs exceeds 2 000 hours, the power will be switch of f after 
    about 10 minutes.
    On-screen displayLamp indicator
    Over 1 800 hours The message is displayed for 30 seconds. 
    Pressing any button on the control panel 
    or remote control within 30 seconds will 
    clear the message.
    Lights in red even during the standby 
    mode.
    Over 2 000 hours The message remains displayed until you 
    press a button.
    Note
     z T
    
    o predict when to replace the lamp, check the lamp cumulative operating hours displayed in [LAMP1] - [LAMP4] 
    (
     page 109) of [STATUS].
     z The usage period of 2 000 hours is a rough estimate and is not guaranteed.
    ▶■ Replacing the lamp unit
    Attention
     z
    When the projector is mounted on the ceiling, do not perform tasks while your face is near the lamp unit.
     zDo not remove or loosen the screws other than specified ones when replacing the lamp.
    1) Set the  switch to  and disconnect the power plug from the 
    power outlet.
    ▶zW ait at least one hour and and check if the lamp unit has cooled down.
    2) Remove the lamp unit cover
    .
    (i) Use a Phillips screwdriver to loosen the lamp unit cover fixing screw (one screw) counterclockwise until 
    it turns freely
    , and then open the lamp unit cover slowly in the direction of the arrow described in the 
    following figure.
    •
    ▶
    Opening the lamp unit cover quickly may result in damage to the cover .
    •
    
    ▶
    I
     f you loosen the lamp unit cover fixing screw with the projector installed upward in the vertical direction, 
    the lamp unit cover may open on its weight and drop off the lamp unit.
    (ii)
     
    Hold the lamp unit cover securely and slide it in the direction of the arrow , and then pull it out backward 
    to remove.
    Lamp unit cover 
    fixing screw
    Lamp unit cover
    Attention
     zBe careful to hold the lamp unit cover and to loosen the lamp unit 
    cover fixing screws with the projector installed upward in the vertical 
    direction since the lamp unit cover may open and the lamp case may 
    drop of
    
    f on its weight.
    –
    ▶
    This can cause severe injury or accidents.
    REPLACE LAMP 
    						
    							Maintenance/replacement
    ENGLISH - 149
    Maintenance
    3) Pull out the lamp case.
    ▶zUse a Phillips screwdriver to turn the lamp case fixing screws of the lamp unit to be replaced (two screws 
    each) counterclockwise until they turn freely
    , and then hold the lamp case handles to be replaced and pull 
    out backward.
    ▶z Do not remove the black screws other than the lamp case fixing screws.
    ▶zWhen you loosen the lamp case fixing screws with the projector installed upward in the vertical direction, 
    the lamp case may drop of
    
    f on its weight. Be sure to hold the lamp case handle when you loosen the lamp 
    case fixing screws.
    ▶z When removing the lamp case, make sure that the projector is stable and remove it in a safe place where 
    the lamp case is dropped of
    
    f.
    Lamp case handlesLamp case LLamp case R
    Lamp case fixing s\wcrews
    /DPSXQLW
    /DPSXQLW
    /DPSFDVH5
    /DPSFDVH/ /DPSXQLW
    /DPSXQLW
    4) Remove the lamp unit.
    ▶z
    Use a Phillips screwdriver to turn the lamp unit fixing screws (two screws) counterclockwise until they turn 
    freely
    , and then remove the lamp unit from the lamp case.
    ▶zHold the handles of the lamp unit and remove it.
    ▶zDo not remove the screws other than the lamp unit fixing screws.
    Lamp unit fixing s\dcrews
    Lamp unit
    Lamp case hand\fe
    Lamp unit 
    hand\fes
    Guide pins and guide\d ho\fes
    Lamp unit
    5) Attach the lamp unit.
    (i) Gently push the new lamp unit into the lamp case. Install the new lamp unit carefully so that the guide 
    pins on the lamp case are inserted into the guide holes on the lamp unit.
    •
    ▶
    If the lamp unit is not installed properly
     , remove it and then gently install it again. Pushing it in forcibly 
    or exerting excessive force may break the connector.
    (ii)
     
    Use a Phillips screwdriver to firmly tighten the lamp unit fixing screws (two screws each).
    ▶zMake sure to attach the lamp unit properly
    
    . 
    						
    							Maintenance/replacement 
    150 - ENGLISH
    Maintenance
    6) Attach the lamp case.
    ▶zGently push in the lamp case along the grooves for the lamp case attachment guide on the projector
    , and 
    then firmly tighten the lamp case fixing screws (two screws).
    ▶z When you secure the lamp case with the projector installed upward in the vertical direction, the lamp case 
    may drop of
    
    f on its weight. Be sure to hold the lamp case handle when you tighten the lamp case fixing 
    screws.
    ▶z If the lamp case is not installed properly
    
    , remove it and then gently install it again. Pushing it in forcibly or 
    exerting excessive force may break the connector.
    ▶z Make sure to attach the lamp case properly
    
    .
    Grooves of the gui\pde to attach the l\pamp case
    Guides to attach t\phe lamp case
    Lamp case handlesLamp case LLamp case R
    Lamp case fixing s\wcrews
    7) Attach the lamp unit cover
    .
    (i) Align the lamp unit cover to the marks of (a) and (b) ( and ) to attach as shown by the arrow.
    (ii)
     
    Close the lamp unit cover in the direction of the arrow and use a Phillips screw driver to firmly tighten 
    the lamp unit cover fixing screw (one screw).
    ▶z Make sure to attach the lamp unit cover properly
    
    .
    D
    E
    L LL
    Note
     zWhen you place the new lamp unit, the projector resets the total usage time of the lamp unit automatically
    .
     zWhen the lamp case is removed or attached, it will be caught because of the fall-prevention stopper
    . 
    
    This, 
    however, is not a problem. 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic DLP Projector PT-DZ21KU PT-DS20KU PT-DW17KU Operating Instructions