Have a look at the manual Panasonic DLP Projector PT-DW740E PT-DW740EL PT-DX810E PT-DX810EL Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ENGLISH - 101 Chapter 4 Settings — [NETWORK] menu [E-mail set up] page You can send E-mail to an E-mail address (maximum two addresses) set in advance when a problem occurs or the cumulative operating time of a lamp reaches a set value. Click [Detailed set up] → [E-mail set up]. (1) (2) (3) (4) (5) (6) 1 [ENABLE] Select [Enable] to use the E-mail function. 2 [SMTP SERVER NAME] Enter the IP address or the server name of the E-mail server (SMTP). To enter the server name, the setup of the DNS server is required. 3 [MAIL FROM] Enter the E-mail address of the projector. (Up to 63 characters in single byte) 4 [MEMO] You can enter information such as the location of the projector that notifies the sender of the E-mail. (Up to 63 characters in single byte) 5 [MINIMUM TIME] Change the minimum interval for the temperature warning mail. The default value is 60 minutes. In this case, another E-mail will not be sent for 60 minutes after sending the temperature warning mail even if it reaches the warning temperature. 6 [INTAKE AIR TEMPERATURE] Change the temperature setting for the temperature warning mail. A temperature warning mail is sent when the temperature exceeds this value. (8) (7) 7 [E-MAIL ADDRESS 1] Enter the E-mail address to be sent. 8 Settings of the conditions to send E-mail Select the conditions to send E-mail. [MAIL CONTENTS]: Select either [NORMAL] or [SIMPLE]. [ERROR]: An E-mail message is sent when an error occurred in the self- diagnosis. [LAMP1 RUNTIME]: An E-mail message is sent when the remaining lamp on time for the lamp 1 has reached the value set at the right field. [LAMP2 RUNTIME]: An E-mail message is sent when the remaining lamp on time for the lamp 2 has reached the value set at the right field. [INTAKE AIR TEMPERATURE]: An E-mail message is sent when the air intake temperature has reached the value set at the above field. [PERIODIC REPORT]: Place a check mark on this when E-mail is to be sent periodically. It will be sent on the days and time with the check mark.
102 - ENGLISH Chapter 4 Settings — [NETWORK] menu (11) (10) (9) 9 [E-MAIL ADDRESS 2] Enter the E-mail address to be sent when two E-mail addresses are to be used. Leave it blank when two E-mail addresses are not to be used. 10 Settings of the conditions to send E-mail Select the conditions to send E-mail to the second E-mail address. [MAIL CONTENTS]: Select either [NORMAL] or [SIMPLE]. [ERROR]: An E-mail message is sent when an error occurred in the self- diagnosis. [LAMP1 RUNTIME]: An E-mail message is sent when the remaining lamp on time for the lamp 1 has reached the value set at the right field. [LAMP2 RUNTIME]: An E-mail message is sent when the remaining lamp on time for the lamp 2 has reached the value set at the right field. [INTAKE AIR TEMPERATURE]: An E-mail message is sent when the air intake temperature has reached the value set at the above field. [PERIODIC REPORT]: Place a check mark on this to send E-mail to the second E-mail address periodically. It will be sent on the days and time with the check mark. 11 [Submit] Update the settings. [Authentication set up] page You can set the authentication items when POP authentication or SMTP authentication is necessary to send an E-mail message. Click [Detailed set up] → [Authentication set up]. (1) (2) (3) (4) (5) (6) (7) (8) 1 [Auth] Select the authentication method specified by your Internet service provider. 2 [SMTP Auth] Set when the SMTP authentication is selected. 3 [POP server name] Enter the POP server name. Allowed characters: Alphanumerics (A to Z, a to z, 0 to 9) Minus sign (-) and period (.) 4 [User name] Enter the user name for the POP server or the SMTP server. 5 [Password] Enter the password for the POP server or the SMTP server. 6 [SMTP server port] Enter the port number of the SMTP server. (Normally 25) 7 [POP server port] Enter the port number of the POP server. (Normally 110) 8 [Submit] Update the settings.
ENGLISH - 103 Chapter 4 Settings — [NETWORK] menu Contents of mail sent Example of E-mail sent when E-mail is set The following E-mail is sent when the E-mail settings have been established. === Panasonic projector report(CONFIGURE) === Projector Type : DW740 Serial No : SH1234567 ----- E-mail setup data ----- TEMPERATURE WARNING SETUP MINIMUM TIME at [ 60] minutes interval INTAKE AIR TEMPERATURE Over [ 45C / 113F ] ERROR [ OFF ] LAMP1 RUNTIME [ OFF ] at REMAIN [ 400] H LAMP1 RUNTIME [ OFF ] at REMAIN [ 200] H LAMP2 RUNTIME [ OFF ] at REMAIN [ 400] H LAMP2 RUNTIME [ OFF ] at REMAIN [ 200] H INTAKE AIR TEMPERATURE [ OFF ] PERIODIC REPORT Sunday [ OFF ] Monday [ OFF ] Tuesday [ OFF ] Wednesday [ OFF ] Thursday [ OFF ] Friday [ OFF ] Saturday [ OFF ] 00:00 [ OFF ] 01:00 [ OFF ] 02:00 [ OFF ] 03:00 [ OFF ] 04:00 [ OFF ] 05:00 [ OFF ] 06:00 [ OFF ] 07:00 [ OFF ] 08:00 [ OFF ] 09:00 [ OFF ] 10:00 [ OFF ] 11:00 [ OFF ] 12:00 [ OFF ] 13:00 [ OFF ] 14:00 [ OFF ] 15:00 [ OFF ] 16:00 [ OFF ] 17:00 [ OFF ] 18:00 [ OFF ] 19:00 [ OFF ] 20:00 [ OFF ] 21:00 [ OFF ] 22:00 [ OFF ] 23:00 [ OFF ] ----- check system ----- MAIN CPU BUS [ OK ] FAN [ OK ] INTAKE AIR TEMPERATURE [ OK ] OPTICS MODULE TEMPERATURE [ OK ] AROUND LAMP TEMPERATURE [ OK ] LAMP1 REMAIN TIME [ OK ] LAMP2 REMAIN TIME [ OK ] LAMP1 STATUS [ OK ] LAMP2 STATUS [ OK ] SHUTTER [ OK ] INTAKE AIR TEMP.SENSOR [ OK ] OPTICS MODULE TEMP.SENSOR [ OK ] AROUND LAMP TEMP.SENSOR [ OK ] BATTERY [ OK ] COLOR WHEEL [ OK ] COVER OPEN [ OK ] FILTER UNIT [ OK ] AIR FILTER [ OK ] (Error code 00 00 00 00 00 00 00 00) Intake air temperature : 26 degC / 78 degF Optics module temperature : 39 degC / 102 degF Around lamp temperature : 30 degC / 86 degF PROJECTOR RUNTIME 1 H POWER ON 1 times LAMP1 ON 1 times LAMP1 ECO 0 H LAMP1 NORMAL 0 H LAMP1 REMAIN 1999 H LAMP2 ON 1 times LAMP2 ECO 0 H LAMP2 NORMAL 1 H LAMP2 REMAIN 1999 H -------- Current status --------- MAIN VERSION 1.00 NETWORK VERSION 1.00 SUB VERSION 1.00 LAMP STATUS LAMP1=ON LAMP2=ON INPUT SIGNAL RGB1 --- 0.00kHz / 0.00Hz REMOTE2 STATUS DISABLE ----- Wired Network configuration ----- DHCP Client OFF IP address 192.168.10.100 MAC address 70:58:12:00:00:00 Wed Jan 18 11:42:37 2012 ----- Memo -----
104 - ENGLISH Chapter 4 Settings — [NETWORK] menu Example of the E-mail sent for an error The following E-mail is sent when an error has occurred. === Panasonic projector report(CONFIGURE) === Projector Type : DW740 Serial No : SH1234567 ----- check system ----- MAIN CPU BUS [ OK ] FAN [ OK ] INTAKE AIR TEMPERATURE [ OK ] OPTICS MODULE TEMPERATURE [ OK ] AROUND LAMP TEMPERATURE [ OK ] LAMP1 REMAIN TIME [ OK ] LAMP2 REMAIN TIME [ OK ] LAMP1 STATUS [ OK ] LAMP2 STATUS [ OK ] SHUTTER [ OK ] INTAKE AIR TEMP.SENSOR [ OK ] OPTICS MODULE TEMP.SENSOR [ OK ] AROUND LAMP TEMP.SENSOR [ OK ] BATTERY [ OK ] COLOR WHEEL [ OK ] COVER OPEN [ OK ] FILTER UNIT [ FAILED ] AIR FILTER [ OK ] (Error code 04 00 00 00 00 00 00 00) Intake air temperature : 26 degC / 78 degF Optics module temperature : 39 degC / 102 degF Around lamp temperature : 30 degC / 86 degF PROJECTOR RUNTIME 1 H POWER ON 1 times LAMP1 ON 1 times LAMP1 ECO 0 H LAMP1 NORMAL 0 H LAMP1 REMAIN 1999 H LAMP2 ON 1 times LAMP2 ECO 0 H LAMP2 NORMAL 1 H LAMP2 REMAIN 1999 H -------- Current status --------- MAIN VERSION 1.00 NETWORK VERSION 1.00 SUB VERSION 1.00 LAMP STATUS LAMP1=ON LAMP2=ON INPUT SIGNAL RGB1 --- 0.00kHz / 0.00Hz REMOTE2 STATUS DISABLE ----- Wired Network configuration ----- DHCP Client OFF IP address 192.168.10.100 MAC address 70:58:12:00:00:00 Wed Jan 18 11:42:37 2012 ----- Memo ----- User name [Change password] page Click [Change password]. 1 2 3 1 [Administrator] Used to change the setting of the [Administrator]. 2 [User] Used to change the setting of the [User]. 3 [Next] Used to change the setting of the password.
ENGLISH - 105 Chapter 4 Settings — [NETWORK] menu [Administrator] account (1) (2) (3) (4) (5) (6) (7) 1 [Account] Displays the account to change. 2 [Current][User name] Enter the user name before the change. 3 [Current][Password] Enter the current password. 4 [New][User name] Enter the desired new user name. (Up to 16 characters in single byte) 5 [New][Password] Enter the desired new password. (Up to 16 characters in single byte) 6 [New][Password(Retype)] Enter the desired new password again. 7 [OK] Determines the change of password. [User] account (1) (2) (3) (5) (4) 1 [Account] Displays the account to change. 2 [New][User name] Enter the desired new user name. (Up to 16 characters in single byte) 3 [New][Password] Enter the desired new password. (Up to 16 characters in single byte) 4 [New][Password(Retype)] Enter the desired new password again. 5 [OK] Determines the change of password.
106 - ENGLISH Chapter 4 Settings — [NETWORK] menu [Change password] (For user rights) Only the change of password is enabled under the user rights. (1) (2) (4) (3) 1 [Old Password] Enter the current password. 2 [New Password] Enter the desired new password. (Up to 16 characters in single byte) 3 [Retype] Enter the desired new password again. 4 [OK] Determines the change of password. Note r f To change the account of the administrator, you must enter the [Current] [User name] and [Password]. [CRESTRON RoomView] page The projector can be monitored and/or controlled with RoomView. To start the RoomView control page from the Web control screen, you need to access with the administrator rights. (For user rights, the [CRESTRON RoomView] button is not displayed on the Web control screen.) The control page of RoomView is displayed by clicking [CRESTRON RoomView]. It is not displayed if Adobe Flash Player is not installed on the computer used, or the browser\ used does not support Flash. In that case, click [Back] on the control page to go back to the previous page. Control page 1 2 3 4 5 6 7 1 [Tools][Info][Help] Tabs for selecting the setting, information, or help page of the projector. 2 [POWER] Switches the power on/off. 3 [SHUTTER] Switches between use or not use of the shutter function. 4 [Input Select] Controls input selection. Not available when the power of the projector is turned off. 5 Menu screen control buttons Navigates the menu screen. 6 Freeze/Picture quality adjustment Controls items related to freeze/picture quality. 7 [Back] Performs return to the previous page.
ENGLISH - 107 Chapter 4 Settings — [NETWORK] menu [Tools] page Click [Tools] on the control page. 1 2 3 4 5 1 [Control System] Set the information required for communicating with the controller to be connected with the projector. 2 [User Password] Set the user rights password for the RoomView control page. 3 [Admin Password] Set the administrator rights password for the RoomView control page. 4 Network Status Displays the settings of wired LAN. [DHCP] Displays the current setting. [Ip Address] Displays the current setting. [Subnet Mask] Displays the current setting. [Default Gateway] Displays the current setting. [DNS Server] Displays the current setting. 5 [Exit] Returns to the control page. [Info] page Click [Info] on the control page. 45 6 7 1 2 3 8 1 [Projector Name] Displays the projector name. 2 [Mac Address] Displays the MAC address. 3 [Lamp Hours] Displays the cumulative operating time (converted value) of the lamps. 4 [Power Status] Displays the status of the power. 5 [Source] Displays the selected image input. 6 [Lamp Mode] Displays the lamp mode. 7 [Error Status] Displays the error status. 8 [Exit] Returns to the control page.
108 - ENGLISH Chapter 4 Settings — [NETWORK] menu [Help] page Click [Help] on the control page. The [Help Desk] window is displayed. 1 1 [Help Desk] Messages can be sent to or received from an administrator who uses Crestron RoomView.
ENGLISH - 109 Chapter 5 Maintenance This chapter describes inspection when there are problems, and maintenan\ ce methods.
110 - ENGLISH Chapter 5 Maintenance — Lamp/Temperature/Filter indicators Lamp/Temperature/Filter indicators Managing the indicated problems If a problem should occur inside the projector, the lamp indicators // the temperature indicator and the filter indicator will inform you by lighting or flashing. Check the status of the indicators and manage the indicated problems as \ follows. Attention r f When switching off the projector to deal with problems, make sure to follow the procedure in “Switching off the projector” ( x page 43). r f Check the status of the power supply with the power indicator ( x page 42). Lamp indicator Power indicator Lamp indicator Temperature indicator Filter indicator Lamp indicators / Indicator status Lighting in red Flashing in red (1 time) Flashing in red (3 times) Status Time to replace the lamp unit. The lamp unit is not attached.A problem is detected in the lamp or the power supply for the lamp. Cause r f Was [REPLACE LAMP] displayed when you turned on the power of the projector? r f This indicator lights up when the cumulative operating time of the lamp unit has reached 1 800 hours (when [LAMP POWER] is set to [NORMAL]). r f Is the lamp unit attached? r f Have you turned on the power again immediately after turning it off? r f Some error has arisen in the lamp circuit. Check for fluctuation (or drop) in the source voltage. Solution r f Replace the lamp unit. r f Install the lamp case if the lamp unit is not installed. r f If the indicator is still blinking in red even though the lamp unit is not installed, consult your dealer. r f Wait a while until the luminous lamp cools off, and then turn on the power. r f Turn the switch ( x page 43), and consult your dealer. Note r f If lamp indicator / is still lit or flashing after the preceding measures are taken, ask your dealer to repair the unit.