Home > Panasonic > Recording Equipment > Panasonic Digital Disk Recorder Wj Rt416 Operating Instructions

Panasonic Digital Disk Recorder Wj Rt416 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Digital Disk Recorder Wj Rt416 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							51
    Setup menu
    It is necessary to configure the settings on the setup menu in advance to operate the recorder.
    Display the setup menu on the monitor and configure the settings.
    Setup menu chart
    Setup item Description Page
    System SetupConfigure the settings relating to the system such as the clock adjust-
    ment, language setting, auto login user, etc.
    Recording Setup
    Common Setup Configure the basic settings to be applied regardless of the recording
    type (manual recording, timer recording, alarm recording).
    Manual Rec. Setup Configure the image quality and the recording rate for the manual
    recording.
    Timer Rec. Setup Configure the schedule settings of the timer recording.
    Event Setup
    Common Setup Configure the basic settings relating to the event action to be applied
    regardless of the event type.
    Alarm Rec. Setup Configure the settings for the alarm recording.
    Display SetupConfigure the settings relating to image display.
    Camera Control SetupConfigure the communication type for the camera control and the
    cable compensation setting for each channel.
    Communication Setup
    Network Setup Configure the basic settings relating to the network connection.
    RS485 Setup Configure the RS485 settings.
    PS.Data Setup Configure the PS·Data settings.
    User Management
    User Level Setup Configure the operational level of operator and viewer for each
    channel.
    Password Set the password for each user level.
    Logout Log out the recorder.
    Maintenance
    Alarm Log Log of event occurrences can be checked.
    Error Log Log of error occurrences can be checked.
    System Information System information such as the firmware version, MAC address, etc.
    can be checked.
    Current Recording Settings The current recording settings for each camera channel such as the
    recording rate can be checked.
    Disk Management Format of the built-in HDDs and restore of HDD management informa-
    tion (list information of recorded images) are available.
    Online User Information Information and operational status (user name, etc.) of the users who
    is currently accessing the recorder can be checked.
    Factory Default Reset the current settings to the default.
    Reboot System Reboot of the recorder is available.
    Advanced Information Log of operations and accesses can be checked.
    Firmware upgrade is also available.53
    55
    57
    57
    58
    59
    61
    62
    63
    64
    64
    66
    67
    67
    68
    68
    69
    69
    69
    70
    70
    70
    71 
    						
    							52
    Basic operation of the setup menu
    Screenshot 1
    Display the setup menu by pressing the SETUP button.Step 1
    Press the [SET] button after selecting the desired setup
    item using the arrows button (Cor D).           Setup Menu
    System Setup
    Recording Setup
    Event Setup
    Display Setup
    Camera Control Setup
    Communication Setup
    User Management
    Maintenance
    Screenshot 2
    The submenu of the selected setup item will be displayed.
    (Example: When Recording Setup is selected) Step 2
    Press the [SET] button after selecting the desired submenu
    using the arrows button (Cor D).
            Recording Setup
    Common Setup
    Manual Rec. Setup
    Timer Rec. Setup
    Screenshot 3
    The setup window of the selected submenu will be dis-
    played.
    (Example: When Common Setup is selected) Step 3
    Configure each setting on the setup window.
    To select the setup item:Move the cursor onto the
    desired setup item using the arrows button (CDAB).
    To change the parameter, to move the cursor on the
    setup window:Press the [SKIP s] or [SKIP d] button.
    To enter a number:Press the camera selection buttons.
    To go back to the previous page:Press the [ESC] button.
    Step 4
    To save the settings, move the cursor onto OK and press
    the [SET] button.
    To cancel the edited settings, move the cursor onto
    Cancel and press the [SET] button.
    Common Setup
    Power On Manual Rec.
    Off
    Overwrite
    On
    Audio Select
    Set
    Advanced Setup
    Set→
    OKCancel 
    						
    							53
    Time & Date Setup (Time Zone)
    Adjust the clock of the recorder. Select the time zone
    according to the location where the recorder is.
    Refer to page 17 for how to adjust the clock.
    Default:GMT –5:00 (NTSC model)
    GMT +0:00 (PAL model)
    Language
    Select the display language from the following.
    English/Japanese/Chinese/Custom
    When selecting Custom, display characters can be
    changed according to your needs. Refer to the operating
    instructions of the monitoring software (PDF) on the provid-
    ed CD-ROM for further information.
    Default:English
    Auto Login User
    Configure the auto login user setting.
    Disable:No user can log in automatically.
    Viewer/Operator/Manager:Log in the recorder with its own
    user level.
    Default:Manager
    Auto Logout Time
    When no operation has been made for a period specified in
    advance by a currently logged user (who is not an auto
    login user), this user will forcibly be logged out.
    005 - 999 (Sec)
    Default:600 (Sec)
    Error Buzz
    Set the sounding duration of the buzzer that starts sounding
    at an error occurrence.
    000 - 180 (sec)
    When 000 is selected, the buzzer will not sound.
    Default:002 (sec)System Setup(Advanced)
    The following window will be displayed when the [Set ] but-
    ton is pressed after moving the cursor onto Set→.
    Date Format
    Select a time format from the following.
    (Example: October 5, 2006)
    yyyy-mm-dd: 2006-10-05
    mmm-dd-yyyy: Oct-05-2006
    mm-dd-yyyy: 10-05-2006
    dd-mm-yyyy: 05-10-2006
    dd-mmm-yyyy: 05-Oct-2006
    Default:mmm-dd-yyyy (NTSC model)
    dd-mm-yyyy (PAL model)
    Note:
    Display of month will be mm (numeric) except when
    displaying images (page 15) and Highest
    Temperature of System Information (page 69).
    (Month will not be displayed in alphabet (mmm).)
    Time Format
    Select a time format to be displayed when displaying
    live/recorded images from the following.
    (Example for 3 o’clock in the afternoon)
    12h: 3:00:00 PM
    24h: 15:00:00
    Default:12h (NTSC model)
    24h (PAL model)
                   System Setup
                           Month-Day-Year
    Time & Date            10-22-2006 11:30:30
    (Time Zone)            GMT-5:00
                           Set
    Language               English
    Auto Login User        Manager
    Auto Logout Time       600 Sec
    Error Buzz             002 Sec
    Advanced Setup         Set→
    OK Cancel
              System Setup (Advanced)
    Date Format              mmm-dd-yyyy
    Time Format              12h
    Auto Adjust Time         off
    Summer Time (DST)        off
    Summer Time (DST) Table  Set
    Auto Data Delete         000 Days
    Default Search Time      15 Min Before
    OK Cancel
    Configure the system settings [System Setup]
    Configure the settings relating to the system such as the clock adjustment, language setting, auto login user, etc. 
    						
    							54
    Auto Adjust Time
    When signal is input to the time adjust input terminal on the
    rear of the recorder (page 50), the clock of the recorder
    will be set to 00 minute. The clock will be set to 00 minute
    only when signal is input at the following time.
    • Between 00 minutes 00 seconds and 14 minutes 59
    seconds, every hour
    • Between 45 minutes 00 seconds and 59 minutes 59
    seconds, every hour
    The clock will be set to 00 minutes 00 seconds of the clos-
    est hour.
    Example:
    When 15:00 is set for Time
    Signal is supplied at 14:50:00 (hour:minute:second) →
    Set at 15:00:00
    Signal is supplied at 15:14:45 →Set at 15:00:00
    Signal is supplied at 15:20:00 →Time will not be
    adjusted.
    On:Adjust the clock automatically.
    Off:Do not adjust the clock automatically.
    Default:Off
    Summer Time (DST)
    Select Auto or Off to determine whether or not to apply
    summer time.
    Auto:Apply summer time automatically in accordance with
    the settings for switching to summer time.
    Off:Do not apply summer time.
    Default:Off
    Summer Time (DST) Table
    Set the start/end date and time for summer time. The follow-
    ing window will be displayed when the [SET] button is
    pressed after moving the cursor onto Set.
    Default:As shown in the illustration above. Auto Data Delete
    Configure the settings to delete recorded images automati-
    cally when the set days have passed from the day the
    images were recorded.
    000 - 200 (Days)
    When 000 is selected, images will not be deleted auto-
    matically.
    Default:000 (Days)
    Default Search Time
    It is possible to automatically set the start time (of time
    ranged to be searched) that is specified minutes ago from
    the current time when displaying the search window such
    as the Time & Date Search window.
    For example, when 15 (Min Before) is selected and the
    search window is displayed at 10:00, 9:45 will automati-
    cally be entered for the start time on the search window.
    00 - 60 (Min Before)
    Default:15 (Min Before)
    Summer Time (DST) Table
    INMonth-Day-Year TimeOUT
    OKCancelMonth-Day-Year Time
    1
    03-25-2007 02 :00
    203-30-2008 02 :00
    303-29-2009 02 :00
    403-28-2010 02 :00
    503-27-2011 02 :0010-28-2007 02 :00
    10-26-2008 02 :00
    10-25-2009 02 :00
    10-31-2010 02 :00
    10-30-2011 02 :00 
    						
    							55
    Configure the recording settings [Recording Setup]
    Configure the settings for recording (manual recording, timer recording, alarm recording).
    qConfigure the common recording settings [Common Setup]
    Configure the basic settings to be applied regardless of the recording type (manual recording, timer recording, alarm record-
    ing).
    Power On Manual Rec.
    Select On or Off to determine whether or not to automati-
    cally start manual recording when the power of the recorder
    is turned on.
    On:Start recording automatically.
    Off:Do not start recording automatically.
    Default:Off
    Overwrite
    Select On or Off to determine whether or not to overwrite
    recorded images when the available disk space is running
    out.
    On:Overwrite recorded images.
    Off:Do not overwrite recorded images.
    Default:OnAudio Select
    Select On or Off for each camera channel to determine
    whether or not to record images with audio.
    The following window will be displayed when the [SET] but-
    ton is pressed after moving the cursor onto Set.
    On:Record audio together with images.
    Off:Record only images.
    Default:Off
    Note:
    When Off is selected, no audio will be heard through
    this software.
            Recording Setup
    Common Setup
    Manual Rec. Setup
    Timer Rec. Setup
    qw
    e
    Common Setup
    Power On Manual Rec.
    Off
    Overwrite
    On
    Audio Select
    Set
    Advanced Setup
    Set→
    OKCancel
    Audio Select
    OKCancel
    Cam1Off
    Cam3Off
    Cam5Off
    Cam7Off
    Cam9Off
    Cam11Off
    Cam13Off
    Cam15Off
    Cam2Off
    Cam4Off
    Cam6Off
    Cam8Off
    Cam10Off
    Cam12Off
    Cam14Off
    Cam16Off 
    						
    							56
    Advanced Setup
    The following window will be displayed when the [SET] but-
    ton is pressed after moving the cursor onto Set→.
    Time Per File
    Determine the recording time length of the recorded
    images to be saved as a file. Recorded images will be
    divided into files and the recording time length of each file
    will be the selected time length.
    05 - 60 (Min)
    Default:15 (Min)
    I Frame Interval
    Determine the I-Frame insertion interval.
    1 - 4 (Sec)
    Default:4 (Sec)
    Resolution
    Determine the resolution of recorded images. The following
    window will be displayed when the [SET] button is pressed
    after moving the cursor onto Set.
    Select a resolution for each camera channel from the fol-
    lowing.
    Field:Standard (NTSC model: 704 x 240, PAL model: 704 x
    288)
    SIF:Low (NTSC model: 352 x 240, PAL model: 352 x 288)
    ---:No recording and image transmission is carried out.
    Default:Field
    Common Setup (Advanced)
    Time Per File
    15 Min
    I Frame Interval
    4
    Resolution
    Set
    OKCancel
    Resolution
    OKCancel
    Cam1Field
    Field
    Field
    Field
    Field
    Field
    Field
    Field
    Field
    Field
    Field
    Field
    Field
    Field
    Field
    Field
    Cam3
    Cam5
    Cam7
    Cam9
    Cam11
    Cam13
    Cam15Cam2
    Cam4
    Cam6
    Cam8
    Cam10
    Cam12
    Cam14
    Cam16 
    						
    							57
    wConfigure the manual recording settings [Manual Rec. Setup]
    Configure the settings for manual recording that starts recording when the [REC] button is pressed.
    Camera No.
    Select a camera channel to be used for manual recording.
    Note:
    The camera selection buttons (1 - 10/0) are available for
    the camera channel selection.
    Rec. Quality
    Select an image quality for recorded images from the fol-
    lowing.
    SP Fine:Highest quality
    Fine:High quality
    Normal:Standard quality
    Extended:Low quality
    Default:SP FineRec. Frame Rate
    Select a recording frame rate from the following.
    Full, 1/2F, 1/4F, 1/8F, 1/16F
    (When Full is selected, recording frame rate will be 30
    frames/sec for NTSC model and 25 frames/sec for PAL
    model.)
    Default:Full
    Note:
    When the [SET] button is pressed after moving the cur-
    sor onto All, the same settings for Rec. Quality and
    Rec. Frame Rate will be applied to all of the camera
    channels.
    Camera No., Rec. Quality, Rec. Frame Rate
    These settings can be configured in the same manner as
    for Manual Rec. Setup. Refer to the Manual Rec. Setup
    section.
    Recording time range
    Set the start time and end time for the desired day of the
    week, and then select On.
    Up to 2 time ranges can be set as the timer recording
    schedule.To set the same time range for every day of the week, enter
    the start and end time for DAILY.
    When On and Off of 2 different schedules are set in the
    same time range, the timer recording will be carried out
    according to the schedule for which On is selected.
    Note:
    When the [SET] button is pressed after moving the cur-
    sor onto All, the same settings for Rec. Quality, Rec.
    Frame Rate and Recording time range will be applied
    to all of the camera channels.
    eConfigure the timer recording settings [Timer Rec. Setup]
    Designate a day of the week and time when the timer recording is to be started (timer recording schedule).
    Manual Rec. Setup
    Camera No.
    01
    Rec. Quality
    SP Fine
    Rec. Frame Rate
    Full
    OK
    AllCancel
    Timer Rec. Setup
    01
    SUNCamera No.
    SP FineFull
    MON
    TUE
    WED
    THU
    FRI
    SAT
    DAILY
    All
    OK Cancel 00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off 
    						
    							58
    Configure the alarm action settings [Event Setup]
    Configure the settings relating to the alarm action that is to be taken at an event occurrence.
    Refer to page 27 for further information about the event type and the alarm action.
    qConfigure the common settings for the alarm recording [Common Setup]
    Configure the common settings relating to the alarm action that is to be taken when an event (terminal alarm, VMD alarm, com-
    mand alarm) occurred.
    Alarm Buzz
    Select On or Off to determine whether or not to sound the
    buzzer at an event occurrence. The selected duration for
    Alarm Duration of Alarm Rec. Setup (page 59) will be
    applied as the sounding duration of the buzzer. 
    On:Sound the buzzer
    Off:Do not sound the buzzer
    Default:On
    Alarm Spot
    Select On or Off to determine whether or not to display
    images from the camera that is selected for Alarm Spot
    Camera No. of Alarm Rec. Setup (Advance) (page 59)
    on a single screen at an event occurrence. 
    On:Display images from the selected camera.
    Off:Do not display images from the selected camera.
    Default:On
    Note:
    The screen that was displayed immediately before an
    event resumes after the event is finished.
    Pre Alarm Recording
    Select On or Off to determine whether or not to start
    recording from the specified seconds before an event
    occurrence (pre-alarm recording). 
    On:Start the pre-alarm recording.
    Off:Do not start the pre-alarm recording.
    Default:Off
    Notes:
    • Maximum recording duration of the pre-alarm recording
    is approximately 5 seconds. Recording duration of the
    pre-alarm recording varies depending on the following
    settings.
    • I Frame Interval
    • Capture Resolution
    • Rec. Quality
    • Rec. Frame Rate
    • Audio is not recorded during pre-alarm recording.
    Common Setup
    Alarm Buzz
    On
    Alarm Spot
    On
    Pre Alarm Recording
    Off
    OKCancel
    Event Setup
    Common Setup
    Alarm Rec. Setup
    qw 
    						
    							59
    wConfigure the alarm recording settings [Alarm Rec. Setup]
    Configure the settings relating to the alarm recording that starts upon an event occurrence.
    Alarm No.
    Alarm No. indicates the following according to the event
    type.
    Terminal input:Terminal used for the terminal alarm
    recording.
    VMD:Camera channel
    Command alarm reception:Camera channel
    Note:
    The camera selection buttons (1 - 10/0) are available for
    the camera channel selection.
    Rec. Quality
    Rec. Frame Rate
    These settings can be configured in the same manner as
    for Manual Rec. Setup. Refer to page 57 for further infor-
    mation.
    Term (Alarm Duration)
    Determine the alarm action to be taken and the time range
    when the alarm action is to be taken upon a terminal input
    or a command alarm reception. The alarm action to be
    taken can be determined from the following.
    AL-M:All the set alarm actions will be taken upon a termi-
    nal input.
    AD-M:Some of the alarm action will be taken upon a termi-
    nal input.
    (Refer to the Action at an event occurrence (alarm
    action) section on page 27.)
    Off:No alarm action will be taken.
    Default:Alarm Duration 1: 00:00 - 24:00, Off
    Alarm Duration 2: 00:00 - 24:00, AL-M
    Note:
    When AL-M and AD-M of 2 different alarm durations
    are set in the same time range, the alarm action will be
    taken according to the setting for the alarm duration
    with AL-M.
    Term (Rec. Channel)
    Set the camera channel to be used for the alarm recording
    upon a terminal input or a command alarm reception.
    00 - 16
    When 00 is selected, images from all of the camera
    channel will be recorded.
    Default:(Same value set for Alarm No.)
    VMD (Alarm Duration)
    Determine the alarm action to be taken and the time range
    when the alarm action is to be taken upon a VMD alarm.
    The alarm action to be taken can be determined from the
    following.
    AL-M, AD-M, Off
    Default:00:00 - 24:00, Off (for both Alarm Duration 1 and
    2)
    VMD (Rec. Channel)
    The camera channel used for the alarm recording upon a
    VMD alarm will be displayed.
    The displayed camera channel is the same camera channel
    number as Alarm No. (camera channel number from
    which the VMD alarm is detected). Editing is unavailable.
    VMD (Sensitivity)
    Set the sensitivity level of the VMD function.
    01 (high) - 99 (low)
    Default:10
    Alarm Rec. Setup
    Alarm No.
    Set→
    SP FineFull
    Rec. Channel
    01 Term
    00:0024:00Off00:0024:00AL-M
    Rec. Channel01
    Sensitivity
    10
    Area Setup
    Set VMD
    00:0024:00Off00:0024:00Off
    01
    Advanced Setup
    OK
    AllCancel 
    						
    							60
    VMD (Area Setup)
    Set the VMD area.
    The following window will be displayed when the [SET] but-
    ton is pressed after moving the cursor onto Set.
    Green area:Set as the VMD area.
    Clear area:Not set as the VMD area.
    Red area:Cursor
    Light blue area:Set as the VMD area, and currently motion
    is being detected.
    The VMD area can be set using the following buttons.
    Arrows button: Select an area.
    [SKIP d]/[SKIP s] buttons: Determine whether or not to
    set the selected area as the VMD area (green: set as the
    VMD area, clear: not set as the VMD area). 
    When completing the VMD area setting, press the [ESC]
    button.
    The Alarm Rec. Setup window will be displayed.
    Move the cursor onto OK and press the [SET] button to
    apply the settings.
    Default:All areas are set as the VMD area.
    Notes:
    • The colors of the VMD areas may look not exactly as
    described depending on the brightness or contrast of
    the images displayed in the areas.
    • The VMD area cannot be set for Alarm No. to which no
    video signal is supplied.
    Advanced Setup
    The following window will be displayed when the [SET] but-
    ton is pressed after moving the cursor onto Set→.
    Configure the following settings on the setup window of
    each Alarm No. (page 59).Rec. Duration
    Set the alarm recording duration.
    000, 030 - 999 (sec)
    When 000 is selected, recording will not stop until the
    alarm is reset.
    Default:030 (sec)
    Alarm Duration
    Set the active duration of the alarm action (LED blinking,
    buzzer sounding, alarm output from the terminal on the rear
    of the recorder).
    001 - 999 (Sec)
    Default:030 (Sec)
    Alarm Output Port
    Select a port from which an alarm signal is output.
    0 - 4
    When 0 is selected, no alarm signal will be output.
    Default:0
    Alarm Spot Camera No.
    Select a camera channel from which images are to be dis-
    played on a single screen at an event occurrence.
    1 - 16
    Default:(Same value set for Alarm No.)
    Preset Camera No.
    Select a camera channel that the connected camera is to
    be moved to the preset position at an alarm occurrence.
    1 - 16
    Default:(Same value set for Alarm No.)
    Preset Position
    Set the preset position to which the camera moves at an
    event occurrence.
    000 - 256
    When 000 is selected, the camera will not move at an
    event occurrence.
    Default:000
    [All] button
    When the [SET] button is pressed after moving the cursor
    onto All, the same settings will be applied to the following
    for all of the Alarm No..
    • Rec. Quality
    • Rec. Frame Rate
    • Time range of each schedule
    • Sensitivity
    • Rec. Duration (Advanced Setup)
    • Alarm Duration (Advanced Setup)
    • Alarm Output Port (Advanced Setup)
    Cursor (red)
    Green areas 
    (set as the 
    VMD areas)Clear (colorless) 
    areas (not set as 
    the VMD areas)
    No.01 Alarm Rec. Setup(Advanced)
    Rec. Duration
    060 Sec
    030 Sec
    Alarm Duration
    Alarm Output Port
    0
    Alarm Spot Camera No.
    01
    Preset Camera No.
    01
    Preset Position
    000
    OKCancel 
    						
    All Panasonic manuals Comments (0)