Have a look at the manual Panasonic Digital Disk Recorder Wj Rt416 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
51 Setup menu It is necessary to configure the settings on the setup menu in advance to operate the recorder. Display the setup menu on the monitor and configure the settings. Setup menu chart Setup item Description Page System SetupConfigure the settings relating to the system such as the clock adjust- ment, language setting, auto login user, etc. Recording Setup Common Setup Configure the basic settings to be applied regardless of the recording type (manual recording, timer recording, alarm recording). Manual Rec. Setup Configure the image quality and the recording rate for the manual recording. Timer Rec. Setup Configure the schedule settings of the timer recording. Event Setup Common Setup Configure the basic settings relating to the event action to be applied regardless of the event type. Alarm Rec. Setup Configure the settings for the alarm recording. Display SetupConfigure the settings relating to image display. Camera Control SetupConfigure the communication type for the camera control and the cable compensation setting for each channel. Communication Setup Network Setup Configure the basic settings relating to the network connection. RS485 Setup Configure the RS485 settings. PS.Data Setup Configure the PS·Data settings. User Management User Level Setup Configure the operational level of operator and viewer for each channel. Password Set the password for each user level. Logout Log out the recorder. Maintenance Alarm Log Log of event occurrences can be checked. Error Log Log of error occurrences can be checked. System Information System information such as the firmware version, MAC address, etc. can be checked. Current Recording Settings The current recording settings for each camera channel such as the recording rate can be checked. Disk Management Format of the built-in HDDs and restore of HDD management informa- tion (list information of recorded images) are available. Online User Information Information and operational status (user name, etc.) of the users who is currently accessing the recorder can be checked. Factory Default Reset the current settings to the default. Reboot System Reboot of the recorder is available. Advanced Information Log of operations and accesses can be checked. Firmware upgrade is also available.53 55 57 57 58 59 61 62 63 64 64 66 67 67 68 68 69 69 69 70 70 70 71
52 Basic operation of the setup menu Screenshot 1 Display the setup menu by pressing the SETUP button.Step 1 Press the [SET] button after selecting the desired setup item using the arrows button (Cor D). Setup Menu System Setup Recording Setup Event Setup Display Setup Camera Control Setup Communication Setup User Management Maintenance Screenshot 2 The submenu of the selected setup item will be displayed. (Example: When Recording Setup is selected) Step 2 Press the [SET] button after selecting the desired submenu using the arrows button (Cor D). Recording Setup Common Setup Manual Rec. Setup Timer Rec. Setup Screenshot 3 The setup window of the selected submenu will be dis- played. (Example: When Common Setup is selected) Step 3 Configure each setting on the setup window. To select the setup item:Move the cursor onto the desired setup item using the arrows button (CDAB). To change the parameter, to move the cursor on the setup window:Press the [SKIP s] or [SKIP d] button. To enter a number:Press the camera selection buttons. To go back to the previous page:Press the [ESC] button. Step 4 To save the settings, move the cursor onto OK and press the [SET] button. To cancel the edited settings, move the cursor onto Cancel and press the [SET] button. Common Setup Power On Manual Rec. Off Overwrite On Audio Select Set Advanced Setup Set→ OKCancel
53 Time & Date Setup (Time Zone) Adjust the clock of the recorder. Select the time zone according to the location where the recorder is. Refer to page 17 for how to adjust the clock. Default:GMT –5:00 (NTSC model) GMT +0:00 (PAL model) Language Select the display language from the following. English/Japanese/Chinese/Custom When selecting Custom, display characters can be changed according to your needs. Refer to the operating instructions of the monitoring software (PDF) on the provid- ed CD-ROM for further information. Default:English Auto Login User Configure the auto login user setting. Disable:No user can log in automatically. Viewer/Operator/Manager:Log in the recorder with its own user level. Default:Manager Auto Logout Time When no operation has been made for a period specified in advance by a currently logged user (who is not an auto login user), this user will forcibly be logged out. 005 - 999 (Sec) Default:600 (Sec) Error Buzz Set the sounding duration of the buzzer that starts sounding at an error occurrence. 000 - 180 (sec) When 000 is selected, the buzzer will not sound. Default:002 (sec)System Setup(Advanced) The following window will be displayed when the [Set ] but- ton is pressed after moving the cursor onto Set→. Date Format Select a time format from the following. (Example: October 5, 2006) yyyy-mm-dd: 2006-10-05 mmm-dd-yyyy: Oct-05-2006 mm-dd-yyyy: 10-05-2006 dd-mm-yyyy: 05-10-2006 dd-mmm-yyyy: 05-Oct-2006 Default:mmm-dd-yyyy (NTSC model) dd-mm-yyyy (PAL model) Note: Display of month will be mm (numeric) except when displaying images (page 15) and Highest Temperature of System Information (page 69). (Month will not be displayed in alphabet (mmm).) Time Format Select a time format to be displayed when displaying live/recorded images from the following. (Example for 3 o’clock in the afternoon) 12h: 3:00:00 PM 24h: 15:00:00 Default:12h (NTSC model) 24h (PAL model) System Setup Month-Day-Year Time & Date 10-22-2006 11:30:30 (Time Zone) GMT-5:00 Set Language English Auto Login User Manager Auto Logout Time 600 Sec Error Buzz 002 Sec Advanced Setup Set→ OK Cancel System Setup (Advanced) Date Format mmm-dd-yyyy Time Format 12h Auto Adjust Time off Summer Time (DST) off Summer Time (DST) Table Set Auto Data Delete 000 Days Default Search Time 15 Min Before OK Cancel Configure the system settings [System Setup] Configure the settings relating to the system such as the clock adjustment, language setting, auto login user, etc.
54 Auto Adjust Time When signal is input to the time adjust input terminal on the rear of the recorder (page 50), the clock of the recorder will be set to 00 minute. The clock will be set to 00 minute only when signal is input at the following time. • Between 00 minutes 00 seconds and 14 minutes 59 seconds, every hour • Between 45 minutes 00 seconds and 59 minutes 59 seconds, every hour The clock will be set to 00 minutes 00 seconds of the clos- est hour. Example: When 15:00 is set for Time Signal is supplied at 14:50:00 (hour:minute:second) → Set at 15:00:00 Signal is supplied at 15:14:45 →Set at 15:00:00 Signal is supplied at 15:20:00 →Time will not be adjusted. On:Adjust the clock automatically. Off:Do not adjust the clock automatically. Default:Off Summer Time (DST) Select Auto or Off to determine whether or not to apply summer time. Auto:Apply summer time automatically in accordance with the settings for switching to summer time. Off:Do not apply summer time. Default:Off Summer Time (DST) Table Set the start/end date and time for summer time. The follow- ing window will be displayed when the [SET] button is pressed after moving the cursor onto Set. Default:As shown in the illustration above. Auto Data Delete Configure the settings to delete recorded images automati- cally when the set days have passed from the day the images were recorded. 000 - 200 (Days) When 000 is selected, images will not be deleted auto- matically. Default:000 (Days) Default Search Time It is possible to automatically set the start time (of time ranged to be searched) that is specified minutes ago from the current time when displaying the search window such as the Time & Date Search window. For example, when 15 (Min Before) is selected and the search window is displayed at 10:00, 9:45 will automati- cally be entered for the start time on the search window. 00 - 60 (Min Before) Default:15 (Min Before) Summer Time (DST) Table INMonth-Day-Year TimeOUT OKCancelMonth-Day-Year Time 1 03-25-2007 02 :00 203-30-2008 02 :00 303-29-2009 02 :00 403-28-2010 02 :00 503-27-2011 02 :0010-28-2007 02 :00 10-26-2008 02 :00 10-25-2009 02 :00 10-31-2010 02 :00 10-30-2011 02 :00
55 Configure the recording settings [Recording Setup] Configure the settings for recording (manual recording, timer recording, alarm recording). qConfigure the common recording settings [Common Setup] Configure the basic settings to be applied regardless of the recording type (manual recording, timer recording, alarm record- ing). Power On Manual Rec. Select On or Off to determine whether or not to automati- cally start manual recording when the power of the recorder is turned on. On:Start recording automatically. Off:Do not start recording automatically. Default:Off Overwrite Select On or Off to determine whether or not to overwrite recorded images when the available disk space is running out. On:Overwrite recorded images. Off:Do not overwrite recorded images. Default:OnAudio Select Select On or Off for each camera channel to determine whether or not to record images with audio. The following window will be displayed when the [SET] but- ton is pressed after moving the cursor onto Set. On:Record audio together with images. Off:Record only images. Default:Off Note: When Off is selected, no audio will be heard through this software. Recording Setup Common Setup Manual Rec. Setup Timer Rec. Setup qw e Common Setup Power On Manual Rec. Off Overwrite On Audio Select Set Advanced Setup Set→ OKCancel Audio Select OKCancel Cam1Off Cam3Off Cam5Off Cam7Off Cam9Off Cam11Off Cam13Off Cam15Off Cam2Off Cam4Off Cam6Off Cam8Off Cam10Off Cam12Off Cam14Off Cam16Off
56 Advanced Setup The following window will be displayed when the [SET] but- ton is pressed after moving the cursor onto Set→. Time Per File Determine the recording time length of the recorded images to be saved as a file. Recorded images will be divided into files and the recording time length of each file will be the selected time length. 05 - 60 (Min) Default:15 (Min) I Frame Interval Determine the I-Frame insertion interval. 1 - 4 (Sec) Default:4 (Sec) Resolution Determine the resolution of recorded images. The following window will be displayed when the [SET] button is pressed after moving the cursor onto Set. Select a resolution for each camera channel from the fol- lowing. Field:Standard (NTSC model: 704 x 240, PAL model: 704 x 288) SIF:Low (NTSC model: 352 x 240, PAL model: 352 x 288) ---:No recording and image transmission is carried out. Default:Field Common Setup (Advanced) Time Per File 15 Min I Frame Interval 4 Resolution Set OKCancel Resolution OKCancel Cam1Field Field Field Field Field Field Field Field Field Field Field Field Field Field Field Field Cam3 Cam5 Cam7 Cam9 Cam11 Cam13 Cam15Cam2 Cam4 Cam6 Cam8 Cam10 Cam12 Cam14 Cam16
57 wConfigure the manual recording settings [Manual Rec. Setup] Configure the settings for manual recording that starts recording when the [REC] button is pressed. Camera No. Select a camera channel to be used for manual recording. Note: The camera selection buttons (1 - 10/0) are available for the camera channel selection. Rec. Quality Select an image quality for recorded images from the fol- lowing. SP Fine:Highest quality Fine:High quality Normal:Standard quality Extended:Low quality Default:SP FineRec. Frame Rate Select a recording frame rate from the following. Full, 1/2F, 1/4F, 1/8F, 1/16F (When Full is selected, recording frame rate will be 30 frames/sec for NTSC model and 25 frames/sec for PAL model.) Default:Full Note: When the [SET] button is pressed after moving the cur- sor onto All, the same settings for Rec. Quality and Rec. Frame Rate will be applied to all of the camera channels. Camera No., Rec. Quality, Rec. Frame Rate These settings can be configured in the same manner as for Manual Rec. Setup. Refer to the Manual Rec. Setup section. Recording time range Set the start time and end time for the desired day of the week, and then select On. Up to 2 time ranges can be set as the timer recording schedule.To set the same time range for every day of the week, enter the start and end time for DAILY. When On and Off of 2 different schedules are set in the same time range, the timer recording will be carried out according to the schedule for which On is selected. Note: When the [SET] button is pressed after moving the cur- sor onto All, the same settings for Rec. Quality, Rec. Frame Rate and Recording time range will be applied to all of the camera channels. eConfigure the timer recording settings [Timer Rec. Setup] Designate a day of the week and time when the timer recording is to be started (timer recording schedule). Manual Rec. Setup Camera No. 01 Rec. Quality SP Fine Rec. Frame Rate Full OK AllCancel Timer Rec. Setup 01 SUNCamera No. SP FineFull MON TUE WED THU FRI SAT DAILY All OK Cancel 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off 00: 00 24: 00 Off
58 Configure the alarm action settings [Event Setup] Configure the settings relating to the alarm action that is to be taken at an event occurrence. Refer to page 27 for further information about the event type and the alarm action. qConfigure the common settings for the alarm recording [Common Setup] Configure the common settings relating to the alarm action that is to be taken when an event (terminal alarm, VMD alarm, com- mand alarm) occurred. Alarm Buzz Select On or Off to determine whether or not to sound the buzzer at an event occurrence. The selected duration for Alarm Duration of Alarm Rec. Setup (page 59) will be applied as the sounding duration of the buzzer. On:Sound the buzzer Off:Do not sound the buzzer Default:On Alarm Spot Select On or Off to determine whether or not to display images from the camera that is selected for Alarm Spot Camera No. of Alarm Rec. Setup (Advance) (page 59) on a single screen at an event occurrence. On:Display images from the selected camera. Off:Do not display images from the selected camera. Default:On Note: The screen that was displayed immediately before an event resumes after the event is finished. Pre Alarm Recording Select On or Off to determine whether or not to start recording from the specified seconds before an event occurrence (pre-alarm recording). On:Start the pre-alarm recording. Off:Do not start the pre-alarm recording. Default:Off Notes: • Maximum recording duration of the pre-alarm recording is approximately 5 seconds. Recording duration of the pre-alarm recording varies depending on the following settings. • I Frame Interval • Capture Resolution • Rec. Quality • Rec. Frame Rate • Audio is not recorded during pre-alarm recording. Common Setup Alarm Buzz On Alarm Spot On Pre Alarm Recording Off OKCancel Event Setup Common Setup Alarm Rec. Setup qw
59 wConfigure the alarm recording settings [Alarm Rec. Setup] Configure the settings relating to the alarm recording that starts upon an event occurrence. Alarm No. Alarm No. indicates the following according to the event type. Terminal input:Terminal used for the terminal alarm recording. VMD:Camera channel Command alarm reception:Camera channel Note: The camera selection buttons (1 - 10/0) are available for the camera channel selection. Rec. Quality Rec. Frame Rate These settings can be configured in the same manner as for Manual Rec. Setup. Refer to page 57 for further infor- mation. Term (Alarm Duration) Determine the alarm action to be taken and the time range when the alarm action is to be taken upon a terminal input or a command alarm reception. The alarm action to be taken can be determined from the following. AL-M:All the set alarm actions will be taken upon a termi- nal input. AD-M:Some of the alarm action will be taken upon a termi- nal input. (Refer to the Action at an event occurrence (alarm action) section on page 27.) Off:No alarm action will be taken. Default:Alarm Duration 1: 00:00 - 24:00, Off Alarm Duration 2: 00:00 - 24:00, AL-M Note: When AL-M and AD-M of 2 different alarm durations are set in the same time range, the alarm action will be taken according to the setting for the alarm duration with AL-M. Term (Rec. Channel) Set the camera channel to be used for the alarm recording upon a terminal input or a command alarm reception. 00 - 16 When 00 is selected, images from all of the camera channel will be recorded. Default:(Same value set for Alarm No.) VMD (Alarm Duration) Determine the alarm action to be taken and the time range when the alarm action is to be taken upon a VMD alarm. The alarm action to be taken can be determined from the following. AL-M, AD-M, Off Default:00:00 - 24:00, Off (for both Alarm Duration 1 and 2) VMD (Rec. Channel) The camera channel used for the alarm recording upon a VMD alarm will be displayed. The displayed camera channel is the same camera channel number as Alarm No. (camera channel number from which the VMD alarm is detected). Editing is unavailable. VMD (Sensitivity) Set the sensitivity level of the VMD function. 01 (high) - 99 (low) Default:10 Alarm Rec. Setup Alarm No. Set→ SP FineFull Rec. Channel 01 Term 00:0024:00Off00:0024:00AL-M Rec. Channel01 Sensitivity 10 Area Setup Set VMD 00:0024:00Off00:0024:00Off 01 Advanced Setup OK AllCancel
60 VMD (Area Setup) Set the VMD area. The following window will be displayed when the [SET] but- ton is pressed after moving the cursor onto Set. Green area:Set as the VMD area. Clear area:Not set as the VMD area. Red area:Cursor Light blue area:Set as the VMD area, and currently motion is being detected. The VMD area can be set using the following buttons. Arrows button: Select an area. [SKIP d]/[SKIP s] buttons: Determine whether or not to set the selected area as the VMD area (green: set as the VMD area, clear: not set as the VMD area). When completing the VMD area setting, press the [ESC] button. The Alarm Rec. Setup window will be displayed. Move the cursor onto OK and press the [SET] button to apply the settings. Default:All areas are set as the VMD area. Notes: • The colors of the VMD areas may look not exactly as described depending on the brightness or contrast of the images displayed in the areas. • The VMD area cannot be set for Alarm No. to which no video signal is supplied. Advanced Setup The following window will be displayed when the [SET] but- ton is pressed after moving the cursor onto Set→. Configure the following settings on the setup window of each Alarm No. (page 59).Rec. Duration Set the alarm recording duration. 000, 030 - 999 (sec) When 000 is selected, recording will not stop until the alarm is reset. Default:030 (sec) Alarm Duration Set the active duration of the alarm action (LED blinking, buzzer sounding, alarm output from the terminal on the rear of the recorder). 001 - 999 (Sec) Default:030 (Sec) Alarm Output Port Select a port from which an alarm signal is output. 0 - 4 When 0 is selected, no alarm signal will be output. Default:0 Alarm Spot Camera No. Select a camera channel from which images are to be dis- played on a single screen at an event occurrence. 1 - 16 Default:(Same value set for Alarm No.) Preset Camera No. Select a camera channel that the connected camera is to be moved to the preset position at an alarm occurrence. 1 - 16 Default:(Same value set for Alarm No.) Preset Position Set the preset position to which the camera moves at an event occurrence. 000 - 256 When 000 is selected, the camera will not move at an event occurrence. Default:000 [All] button When the [SET] button is pressed after moving the cursor onto All, the same settings will be applied to the following for all of the Alarm No.. • Rec. Quality • Rec. Frame Rate • Time range of each schedule • Sensitivity • Rec. Duration (Advanced Setup) • Alarm Duration (Advanced Setup) • Alarm Output Port (Advanced Setup) Cursor (red) Green areas (set as the VMD areas)Clear (colorless) areas (not set as the VMD areas) No.01 Alarm Rec. Setup(Advanced) Rec. Duration 060 Sec 030 Sec Alarm Duration Alarm Output Port 0 Alarm Spot Camera No. 01 Preset Camera No. 01 Preset Position 000 OKCancel