61 Configure the display settings [Display Setup] Status Display Determine which information is to be displayed. All:All information will be displayed. Status:The status icons and time and date will be dis- played. Name:The camera title and time and date will be dis- played. Play:Time and date of the recorded images currently being played will be displayed. Off:No information will be displayed. Default:All Note: Error information will be displayed regardless of the set- ting. Sequence Dwell Set the...
Page 62
62 Configure the settings relating to the camera control [Camera Control Setup] Configure the communication type for the camera control and the cable compensation setting for each channel. Type Select a camera control method from the following. Coax:Control the camera using the coaxial communica- tion. (Cam 1 - 8 are available (Cam 5-8 are available only when an optional board is installed).) RS485:Control the cameras using the RS485 communica- tion. Off:Do not control the cameras. Default:Coax (Cam 1 -...
Page 63
63 DHCP Select On or Off to determine whether or not to use the DHCP server. Select On when obtaining values for IP Address, Subnet Mask and Gateway from the DHCP server. Select Off when entering values for IP Address, Subnet Mask and Gateway manually. On:Use the DHCP server Off:Not use the DHCP server Default:off IP Address Enter an IP address. For this recorder, enter 4 units from the decimal numbers (0-255). Default:192.168.0.250Subnet Mask Enter a subnet mask according to the network configura-...
Page 64
64 Baud Rate Select a line speed for data communication with the con- nected device from the following. 2 400/4 800/9 600/19 200/38 400 (bps) Default:19 200 (bps) Data Bit The data bit will be displayed. It is impossible to change the value. Parity A method of checking for errors in communication function- ing will be displayed. It is impossible to change the value. Stop Bit The stop bit type will be displayed. It is impossible to change the value.Unit Address (System) A unit address (Sys) is a...
Page 65
65 Baud Rate Select the communication speed for data transmission with a connected device from the following. 2 400/4 800/9 600/19 200/38 400 bps Default:9 600 Data Bit The data bit will be displayed. It is impossible to change the value for this setting. 8 (bit) Parity Select a method to check a transmission error at com- munication from the following. None:No parity check Even: Even parity Odd:Odd parity Default:None Stop Bit Select a stop bit from the following. 1 bit/2 bit Default:1 (bit) Retry...
Page 66
66 Configure the settings relating to user information [User Management] User information such as the user level, password, etc. can be managed (registration, editing, deletion). qRestrict the operable functions [User Level Setup] Configure the operational level of operator and viewer for each channel. User Management User Level Setup Password Logout qw e Camera No. 01User Level Setup AllYes Operator Live View Yes Operator Playback Yes Viewer Live View Yes Viewer Playback OK Cancel Step 1 Select...
Page 67
67 wSet the password [Password] Set the password for each user level. Password entry will be required to log in the recorder. Enter the password for each user level. Enter the same password in the Confirm box to set the password for Manager or Operator. Character number for the password is as follows. Enter the password using the camera selection buttons (0 - 9). Manager:Up to 8 characters Operator:Up to 6 characters Viewer:Up to 4 characters Display the desired password setup window using the...
Page 68
68 Maintenance functions [Maintenance] Configuration of the settings relating to the HDDs, the system information check, log check, and initialization of the settings are available. qCheck the alarm log [Alarm Log] The alarm logs (time and date of the event occurrence and event) will be displayed in the list form. Refer to page 27 for further information about the events. Up to 9 990 alarm logs can be kept and the older logs will be overwritten by the newer logs. The following is the descriptions of the...
Page 69
69 eCheck the system information [System Information] System information such as the firmware version, MAC address, etc. can be checked. The following can be checked. Firmware Version MAC Address Video Format Optional Board Information about the coaxial communication board (optional) will be displayed. Coax1, Coax2: 2 of the coaxial communication board are installed. Coax1: A single coaxial communication board is installed. --: No coaxial communication board is installed. Current Temperature Highest...
Page 70
70 yCheck the user information of the current login user [Online User Information] By using the monitoring software, it is possible to check user information of the online users such as user name, operational status and IP address. The following information will be displayed for Type. Monitor: Displayed live images from the cameras using the monitoring software Control: Logged in the recorder using the monitoring software Backup: Downloaded recorded images using the monitoring software Talk: Communicated...