Configure the display settings [Display Setup]
Status Display
Determine which information is to be displayed.
All:All information will be displayed.
Status:The status icons and time and date will be dis-
played.
Name:The camera title and time and date will be dis-
played.
Play:Time and date of the recorded images currently
being played will be displayed.
Off:No information will be displayed.
Default:All
Note:
Error information will be displayed regardless of the set-
ting.
Sequence Dwell
Set the...

Page 62

62
Configure the settings relating to the camera control [Camera Control
Setup]
Configure the communication type for the camera control and the cable compensation setting for each channel.
Type
Select a camera control method from the following.
Coax:Control the camera using the coaxial communica-
tion. (Cam 1 - 8 are available (Cam 5-8 are available
only when an optional board is installed).)
RS485:Control the cameras using the RS485 communica-
tion.
Off:Do not control the cameras.
Default:Coax (Cam 1 -...

Page 63

63
DHCP
Select On or Off to determine whether or not to use the
DHCP server.
Select On when obtaining values for IP Address, Subnet
Mask and Gateway from the DHCP server.
Select Off when entering values for IP Address, Subnet
Mask and Gateway manually.
On:Use the DHCP server
Off:Not use the DHCP server
Default:off
IP Address
Enter an IP address. For this recorder, enter 4 units from
the decimal numbers (0-255).
Default:192.168.0.250Subnet Mask
Enter a subnet mask according to the network configura-...

Page 64

64
Baud Rate
Select a line speed for data communication with the con-
nected device from the following.
2 400/4 800/9 600/19 200/38 400 (bps)
Default:19 200 (bps)
Data Bit
The data bit will be displayed. It is impossible to change
the value.
Parity
A method of checking for errors in communication function-
ing will be displayed. It is impossible to change the value.
Stop Bit
The stop bit type will be displayed. It is impossible to
change the value.Unit Address (System)
A unit address (Sys) is a...

Page 65

65
Baud Rate
Select the communication speed for data transmission
with a connected device from the following.
2 400/4 800/9 600/19 200/38 400 bps
Default:9 600
Data Bit
The data bit will be displayed. It is impossible to
change the value for this setting.
8 (bit)
Parity
Select a method to check a transmission error at com-
munication from the following.
None:No parity check
Even: Even parity
Odd:Odd parity
Default:None
Stop Bit
Select a stop bit from the following.
1 bit/2 bit
Default:1 (bit)
Retry...

Page 66

66
Configure the settings relating to user information [User Management]
User information such as the user level, password, etc. can be managed (registration, editing, deletion).
qRestrict the operable functions [User Level Setup]
Configure the operational level of operator and viewer for each channel.
         User Management
User Level Setup
Password
Logout
qw
e
Camera No. 01User Level Setup
AllYes Operator Live View
Yes Operator Playback
Yes Viewer Live View
Yes Viewer Playback
OK Cancel
Step 1
Select...

Page 67

67
wSet the password [Password]
Set the password for each user level. Password entry will be required to log in the recorder.
Enter the password for each user level. Enter the same password in the Confirm box to set the password for Manager or
Operator. Character number for the password is as follows. Enter the password using the camera selection buttons (0 - 9).
Manager:Up to 8 characters
Operator:Up to 6 characters
Viewer:Up to 4 characters
Display the desired password setup window using the...

Page 68

68
Maintenance functions [Maintenance]
Configuration of the settings relating to the HDDs, the system information check, log check, and initialization of the settings are
available.
qCheck the alarm log [Alarm Log]
The alarm logs (time and date of the event occurrence and event) will be displayed in the list form.
Refer to page 27 for further information about the events.
Up to 9 990 alarm logs can be kept and the older logs will be overwritten by the newer logs. 
The following is the descriptions of the...

Page 69

69
eCheck the system information [System Information]
System information such as the firmware version, MAC address, etc. can be checked.
The following can be checked.
Firmware Version
MAC Address
Video Format
Optional Board
Information about the coaxial communication board (optional) will be displayed.
Coax1, Coax2: 2 of the coaxial communication board are installed.
Coax1: A single coaxial communication board is installed.
--: No coaxial communication board is installed.
Current Temperature
Highest...

Page 70

70
yCheck the user information of the current login user [Online User Information]
By using the monitoring software, it is possible to check user information of the online users such as user name, operational
status and IP address.
The following information will be displayed for Type.
Monitor: Displayed live images from the cameras using the monitoring software
Control: Logged in the recorder using the monitoring software
Backup: Downloaded recorded images using the monitoring software
Talk: Communicated...
Start reading Panasonic Digital Disk Recorder Wj Rt416 Operating Instructions

Related Manuals for Panasonic Digital Disk Recorder Wj Rt416 Operating Instructions

All Panasonic manuals