Have a look at the manual Panasonic Digital Disk Recorder Wj Rt208 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
51 Setting item Setting item Setting item 2. Recording Search (SEARCH) 3. Recording & Event Setup (REC & EVENT) 3.1 Timer Recording (TIMER REC) Note:The parameters for this unit can be defined for each channel. 3.2 Terminal Recording (TERMINAL REC) Note:The parameters for this unit can be defined for each channel. The underlined parameters will not be copied when the channel copy is performed.Channel No. Start End Event Only Default setting 0 – – No Available values 0 - 8 – – Yes/No Terminal Input Alarm Output Alarm Time Rec. Interval PTZ Preset Default setting 1 0 030 060 000 Available values 1 - 8 0 - 3 000 - 999 030 - 999 000 - 256 Rec. Channel 1 0 - 8 Rec. Quality Normal SP Fine/Fine/Good/Normal/Extended (Frame Rate) Full Full/1/2F/1/4F/1/8F/1/16F (Stream Type) CBR CBR/VBR Period1 00:00 00:00 - 24:00 24:00 00:00 - 24:00 Off Off/On Period2 00:00 00:00 - 24:00 24:00 On00:00 - 24:00 Off/On Channel (Rec. Quality) (Frame Rate) (Stream Type) SUN - SAT, DAILY Default setting 1 Normal Full CBR 00:00 24:00 Off 00:00 24:00 Off Available values 1 - 8 SP Fine/Fine/Good/Normal/Extended Full/1/2F/1/4F/1/8F/1/16F CBR/VBR 00:00 - 24:00 00:00 - 24:00 Off/On 00:00 - 24:00 00:00 - 24:00 Off/On
52 Setting item Setting item 3.3 VMD Setup (VMD REC) Notes: •The parameters for this unit can be defined for each channel. •The underlined parameters will not be copied when the channel copy is performed. *At the default, no area is selected. Up to 140 (14 x 10) areas are available. 3.4 Recording Length (RECORD LENGTH) 3.5 Audio Selection (AUDIO SELECT) 4. PTZ Setup (PTZ SETUP) 4.1 PTZ Selection (PTZ SELECT) 4.2 Preset Information (PRESET INFORMATION) Channel No. Sensitivity Area Setup Alarm Output (Alarm Time) Default setting 1 10 – * 0 030 Available values 1 - 8 01 - 99 – 0 - 3 000 - 999 Rec. Interval 060 030 - 999 PTZ Preset 000 000 - 256 Rec. Quality Normal SP Fine/Fine/Good/Normal/Extended (Frame Rate) Full Full/1/2F/1/4F/1/8F/1/16F (Stream Type) CBR CBR/VBR Period1 00:00 00:00 - 24:00 24:00 00:00 - 24:00 Off Off/On Period2 00:00 24:00 Off00:00 - 24:00 00:00 - 24:00 Off/On Setting item Record Length Default setting 015 Available values 005 - 240 Setting item Audio1 - 8 Default setting Audio select Available values Selected/not selected Setting item Cam1 - 8 Default setting Not selected Available values Selected/not selected Camera Preset Default setting 1 001 Available values 1 - 8 001 - 256
53 Setting item Available values Available values Available values Alarm Port Alarm Enable Line Speed 5. Camera Setup (CAMERA SETUP) Note:The parameters for this unit can be defined for each channel. 6. Communication Setup (COMMUNICATION SETUP) 6.1 Network Setup (NETWORK SETUP) 6.2 RS485 Setup (RS485 SETUP) Setting item Channel No. CH Enable Mask Area Mask Enable PTZ Protocol Rec. Reserve Channel Name Default setting 1 On – Off PANASONIC 000 CH11 - 8 Off/On – Off/On PANASONIC/TYPE 1/TYPE 2/TYPE 3/TYPE 4 000 - 200 en: 10 letters, em: 5 letters Setting item IP Address Subnet Mask Gateway Server Port Protocol Alarm Center IP Default setting 192.168.000.088 255.255.255.000 192.168.000.001 2000 TCP 192.168.000.188 4000 Off Auto Mode001.000.000.000 - 255.255.255.255 000.000.000.000 - 255.255.255.254 001.000.000.000 - 255.255.255.255 1024 - 9999 TCP/UDP/MCAST 001.000.000.000 - 255.255.255.255 1024 - 9999 Off/On Auto Mode/10M Half/10M Full/100M Half/100M Full Setting item Baud Rate Data Bit Parity Stop Bit Default setting 19200 8 None 12400/4800/9600/19200/38400 – (FIX) – (FIX) – (FIX) 6.3 Data port setup (DATA PORT SETUP) Available values Unit Address (System) Baud Rate Data Bit Parity Stop Bit Retry Timing Alarm Data Channel No. Default setting 001 9600 8 None 1 Off 1s -001 - 099 2400/4800/9600/19200/38400 – (FIX) None/Even/Odd 1/2 Off/100ms/200ms/400ms/1000ms Off/0s/1s/5s -
54 7. Report (REPORT) 7.1 System Log (SYSTEM LOG) Note: n:On-line user number m:HDD position number 7.2 Event Log (EVENT LOG) Note: n:Channel No. (1 - 8) 7.3 Oldest Data Information (OLDEST DATA INFORMATION) Possible displayed contents System Startup Invalid Password [MANAGER] Login [OPERATOR] Login [VIEWER] Login [L] Update Sys Settings [L] Modify Time [L] Reset System Modify Timer Rec. Modify VMD Rec. Modify Terminal Rec. Modify Network Modify Manager Pswd Modify Operator Pswd Modify Viewer Pswd Restore Default Set Possible displayed contents Ch=n VMD alarm Port=n terminal alarm Cam=n loss signal Cam=n get signal Possible displayed contents Format Disk=m Repair Directory Disk m Disconnect User= n [R] Control User Login [R] Video User Login [R] Update Sys Settings [R] Modify Time [R] Reset System Disk Full User Allow Overwrite Full Records Disk Access Error [R] System Updated Thermal Error Fan Error Modify Rec. Reserve
55 Setting item Setting item 8. User Information (USER INFORMATION) 8.1 User Level Setup (USER LEVEL SETUP) Note:The parameters for this unit can be defined for each channel. 8.2 Online User Information (ONLINE USER INFORMATION) 8.3 Password (PASSWORD) 8.4 Keylock (KEYLOCK) 9. Data Management (DATA MANAGEMENT) 9.1 Factory Default (FACTORY DEFAULT) 9.2 Search (BACKUP) Setting item Channel No. Operator - Live Viewer Operator - Playback Viewer - Live Viewer Viewer - Playback Default setting 1 Yes Yes Yes Yes Available values 1 - 8 Yes/No Yes/No Yes/No Yes/No Viewer Operator Manager Default setting 8888 88888 888888 Available values 0 - 999999 0 - 999999 0 - 999999 Setting item Channel No. Start End Event Only Default setting 0 – – No Available values 0 - 8 – – Yes/No User Level Type Default setting – – Available values MANAGER/OPERATOR/VIEWER CONTROL/MONITOR/NETPLAY/FRAME/BACKUP/TALK
56 Operation using the system controller The following are descriptions of how to operate the unit using the system controller WV-CU650. To operate the unit using the system controller WV-CU650, configure the settings required to use a PS·Data compatible system controller in advance. ■Operation using the WV-CU650 Operation WJ-RT208 WV-CU650 Note Open/close the SETUP MENU Select an itemAfter displaying the System Setup (301) submenu of the WV-CU650At the default setting of the WV-CU650, it is possible to display the System Setup (301) submenu by pressing the [F1] button while holding the [SHIFT] but- ton down. SHIFTF1MENUF1 F2 Open the SETUP MENU Close the SETUP MENU 1, 2, ... CAM (SET)or CAM (SET)or MON (ESC) SHIFTALARM ALM SUSPEND RECREC STOP RECREC STOP PLAY/PAUSE STOP Change the set parameter Enter a value Change the cursor position Press a button on the pop-up menu Press a button on the pop-up menu Return to the previous menu Alarm suspension – Manual recording Stop recording Press for 2 seconds or morePress for 2 seconds or more Camera selection buttons 1, 2, … , 9 SET SET ESC ALARM RESET REC STOP PLAY STOP Play Stop playback Available only during recording Alarm reset ALM RESET ALM ALL RESET
57 Operation WJ-RT208 WV-CU650 Note Pause playback Skip to the next frame PAUSEPLAY/PAUSEAvailable only during playback Available only during pause PLAY Skip to the next/previous recordSKIPAvailable only during playback Select a camera Select a multi-screen 5CAM (SET) Switches in the following order each time the button is pressed 4-split screen (1-4 CH) →4-split screen (5-8 CH) →6- split screen →9-split screen Select a camera channel MULTISCREEN Available only when displaying on a multi-screen Select a camera to be dis- played on the upper left area when displaying on a 6-split screen Sequential display ON SEQUENCETOUR SEQ GROUP SEQ Available only when displaying on a 6-split screen It is possible to stop the sequential display by pressing the [TOUR SEQ/GROUP SEQ] button while hold- ing the [SHIFT] button down. SHIFT TOUR SEQ GROUP SEQ Camera selection buttons 1, 2, … , 8 Press Dor C.Camera number MON (ESC)5CH number Camera selection buttons 1, 2, … , 8 5CAM (SET)Camera number Pause the displayed imageAfter displaying the Max Still (305) submenu of the WV- CU650 (Only clockwise rotation is effective.) Press B. or F1 Note: When the recorder is in the camera control mode ( ), some functions may be inoperable when controlling the recorder using the system controller. To use all functions, press the [OSD] button ( ) on the system controller for sever- al times.OSD STILL REV FWD PLAY Press for 2 seconds or more Fast forward/rewind Slow playback When the shuttle ring is rotated clockwise: Slow play- back, Normal speed playback, >>, >>>>, >>>>>> When the shuttle ring is rotated counterclockwise:
– These may be occurred due to the performance of this unit. However, this is not an error. 58 Confirm whether the power plug is inserted in an AC wall outlet. Troubleshooting Prior to repairing services, verification should be carried out for the respective items specified below. Contact a dealer if a problem cannot be solved even after checking and trying the solution, or if a problem is not described below, or when having an installation problem. Power is not turned on. Images do not fit on the screen. Camera images look dark and pale. Parameter cannot be set up with a SETUP MENU. Noise is generated during play- back and images are some- times distorted during playback. Response is delayed when text is displayed, buttons are pressed, or the VMD function is activated. – Is the power cord connected to the power outlet of this unit?– No camera images are dis- played. Is the camera lens dislodged?– Is the power supply turned ON for the camera and connected devices?– Is the cable connected correctly?– Are the screen setup parameters correct? Refer to page 33. Confirm the user log-in security level. Refer to page 22. This is not a fault. It is a resolution problem. Depending on the monitor, images will not fit on the screen.– Aren’t there dusts or dirt on the camera lens?– Confirm the user level for log-in. Refer to page 22. While NetBackup (data backup function) is being performed using the provided software, these responses may be delayed. – Page Check item/remedyProblem
59 Specifications ■Basic Specifications General Power supply 120 V AC, 60 Hz Power consumption (approx.) 120 W Ambient operating temperature +5 °C - +45 °C (41 °F - 113 °F) Ambient operating humidity 5 - 90 % (without condensation) Dimensions 430 mm (W) x 88 mm (H) x 470 mm (D) [16.9 (W) x 3.5 (H) x 18.5 (D)] Weight (approx.) WJ-RT208K: 9.0 k g(19.9 lb) (No hard disk model) WJ-RT208: 10.0 k g(22.0 lb) (2 hard disks model) Input/Output Video Video input 1.0 V[P-P]/75 ΩNTSC composite video signal (BNC) x 8 Video output 1.0 V[P-P]/75 ΩNTSC composite video signal (BNC) x 1 RGB output (15 pin D-sub) x 1 Audio Audio input –10 dB 22 kΩ(BNC) x 8 Audio output –10 dB 22 kΩ(BNC) x 1 Alarm Alarm input Voltage value alarm input (25-pin, D-sub) x 8 Alarm output Switch volume output (contact output of normally ON and normally OFF) (25-pin, D-sub) Ethernet port 10BASE-T/100BASE-Tx (RJ-45) x 1 Remote interface RS485 x 1 (25 pin D-sub) Data interface RS485 x 1 (RJ-11) Data backup interface High speed serial interface (front panel x 1, rear panel x 1, 0.8 Mbps to 1.3 Mbps of transfer rate depending on recorder operating state) HDD interface 4 IDE interfaces are incorporated. (capable of installing eight hard disks) Function Video compression mode MPEG4 [CBR (fixed bit stream)/VBR (variable bit stream)] Audio compression mode ADPCM Picture quality (compressed level) Class 5 (independent setting enabled for each line) Image resolution Live aspect 704 x 480 Recording picture playback 352 x 240 (SIF) Image display 1-/4-/6-/9-split screen display Image Recording Rate Live recording of each line (1-30 frames/sec. for each line, adjustable) Simultaneous operation Field multiscreen monitoring, recording, playback, network monitor- ing Recording Mode Manual/Timer/Terminal/VMD/Power ON REC mode Video Motion Detection 140 items of motion detector area/motion detector sensitivity Class 99 can be independently set up for each line. (Adjustments are pos- sible.)
Recording mode 60 ■Table of Recording Length Approximate recording days Table 1 Caution: 1. Recording conditions: 8CH, Recording time: 10 hours/day, Stream type: CBR, Audio selection: Off, VMD: Off, I frame Inter.: 4 (default) 2. The recording time may differ from the values in the table above according to the selected picture quality. Table 2 30 frames/secImage quality Super fine Fine Good Normal ExtendedHDD capacity 250 GB 7 9 12 17 3914 18 25 34 7821 27 37 51 11728 36 49 68 15535 45 62 86 19443 54 74 103 23350 63 86 120 27257 72 99 137 311 500 GB 750 GB 1000 GB 1250 GB 1500 GB 1750 GB 2000 GB Standard Accessories CD-ROM .................................................................. 1 pc. Operating Instructions (This Document) ................. 1 pc. Note:The files specified below are included on the CD-ROM. Network Operating Instructions (pdf) Net Client (software) The following are for installation: Power cord .............................................................. 1 pc. HDD mounting screw WJ-RT208K ...................................................... 32 pcs. WJ-RT208 ......................................................... 24 pcs. Recording mode 30 frames/secImage quality Super fine Fine Good Normal ExtendedHDD capacity 250 GB 3 4 5 7 166 7 10 14 329 11 15 21 4812 15 20 28 6515 19 26 36 8118 22 31 43 9721 26 36 50 11324 30 41 57 130 500 GB 750 GB 1000 GB 1250 GB 1500 GB 1750 GB 2000 GB Caution: 1. Recording conditions: 8CH, Recording time 24 hours/day, Stream type: CBR, Audio selection: Off, VMD: Off, I frame Inter.: 4 (default) 2. The recording time may differ from the values in the table above according to the selected picture quality.