Home > Panasonic > Recording Equipment > Panasonic Digital Disk Recorder Wj Rt208 Operating Instructions

Panasonic Digital Disk Recorder Wj Rt208 Operating Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Digital Disk Recorder Wj Rt208 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							31
    (4) After completing the settings, press the [MENU] button
    again to close the camera setup menu.
    Caution:When displaying the Special Menu, move the
    cursor to SPECIAL on the camera setup menu and
    press the camera selection button [2].
    When returning the camera settings to the default
    settings, move the cursor to CAMERA RESET and
    press the camera selection button [3].
    Press the [ESC] button to move from the Special
    menu back to the previous menu.
    2.6 Control this Unit with a PC
    When this unit is connected to a network, it is possible to
    operate and set up this unit with the software on the acces-
    sory disc. 
    In this case, outlined explanations will be given about the
    functions available and requirements for the computer con-
    figuration. 
    For details about each function, refer to the Network
    Operating Instructions on the accessory disc.
    2.6.1 Outlined functions
    •Display of live monitoring screen and recording
    •Playback and downloading of the recorded data
    •Setup of this unit
    •Event notification (Alarm)
    •Automatic time and date adjustment
    2.6.2 Computer configuration
    A computer with the configuration specified below is rec-
    ommended. If a computer other than the recommended
    one is used, some problems may arise including software
    not starting, delayed screen display, and operation failures.
    Notes: 
    *If the Graphic Memory is not over 32 MB, only a maxi-
    mum of four channels can be connected to the
    NetClient.
    *The NetClient cannot be started unless the display driv-
    er overlay is applied.
    *For some display driver versions, the NetClient may fail
    to start normally. In this case, update the display driver
    to the latest version.
    OS
    PC
    CPU
    Main
    Memory
    Graphic
    Memory
    Display
    Driver
    Interface
    Monitor
    OthersMicrosoft Windows 2000 Professional SP4
    Microsoft Windows XP Professional or Edition
    SP2
    IBM PC/AT Compatible
    Intel Pentium 4, 2.4 GHz or faster
    DDR 512 MB
    Independent larger than 64 MB
    Overlay supported
    100 MB network interface card built-in
    Resolution: better than 1024 x 768,
    24 bit true color
    Direct X 8.0a or later 
    						
    							32
    3. Setup
    Setup Menu List
    Setting Item
    SYSTEM MANAGEMENT
    SYSTEM SETUP
    DISK INFORMATION
    REBOOT SYSTEM
    PICTURE ADJUST
    TIME & DATE
    VERSION
    SEARCH
    Description
    Basic operation settings of this unit
    HDD information and initialization
    Restart of this unit
    Screen adjustment of each channel
    Time and date setting
    Version confirmation of the software
    Recording data check and playback
    Timer recording settings of each channel
    REC & EVENT SETUP
    TIMER REC
    TERMINAL REC Terminal recording settings of each channel
    VMD REC Motion detector recording settings of each channel
    RECORD LENGTH Partial length of recording
    AUDIO SELECT Selection of the presence of audio
    PTZ SETUP
    PTZ selection
    PTZ SELECT
    PRESET INFORMATION PTZ preset position check
    CAMERA SETUPCamera connection check and protocol settings
    COMMUNICATION SETUP
    Settings for network IP address, gateway, etc.NETWORK SETUP
    RS485 SETUP Settings for RS485 communication
    DATA PORT SETUP Settings for serial data communication
    REPORT
    SYSTEM LOG
    EVENT LOG
    OLDEST DATA INFORMATION
    USER INFORMATION
    USER LEVEL SETUPOperating log of this unit, and trouble log
    Log at event occurrence 
    Time of the oldest recording data on the hard disc
    Functional setup to enable the user at each level to operate in each channel
    ONLINE USER INFORMATION Display of IP address for on-line user
    PASSWORD User password setup at each level
    KEYLOCK Keyboard lock
    DATA MANAGEMENT
    FACTORY DEFAULT
    BACKUPReturning each setup parameter to the default settings
    Recorded data backup in the external hard disk 
    						
    							33
    3.1 Operation for Various Settings
    3.1.1 System Management (SYSTEM MAN-
    AGEMENT)
    (1) Press the [MENU] button. WJ-RT208 SETUP MENU
    appears.
    (2) Move the cursor to SYSTEM MANAGEMENT and
    press the [SET] button.
    (3) Move the cursor to SYSTEM SETUP and press the
    [SET] button.
       WJ-RT208 SETUP MENU
    SYSTEM MANAGEMENT
    SEARCH
    REC&EVENT SETUP
    PTZ SETUP
    CAMERA SETUP
    COMMUNICATION SETUP
    REPORT
    USER INFORMATION
    DATA MANAGEMENT
        SYSTEM MANAGEMENT
    SYSTEM SETUP 
    DISK INFORMATION 
    REBOOT SYSTEM 
    PICTURE ADJUST 
    TIME & DATE 
    VERSION 
    Off Power On Rec.
    NTSC Video Format
    All Status Display
    On Keylock Buzz
    Off Pre Recording
    04 I Frame Inter.
    Off
    OK Cancel Alarm Spot
    N.O. Terminal Input05 Seq. Dwell
    On Overwrite
    600 Keylock TimeSec
    Sec
    Off Alarm Buzz
    Normal  Rec. Quality
    800x600 Resolution
    CBR Stream Type
    Full Frame Rate SYSTEM SETUP 
    						
    							Descriptions and remarksSelectable parameters
    [Default Setting]Item
    Full, 1/2F, 1/4F, 1/8F, 1/16F
    Full
    Note:When Terminal Input is set at N.C., an alarm unit of N.O. should be connected to the alarm port of this unit. If no con-
    nections are made, the alarm port will be N.O. (normally open) and will continue receiving alarm signals at all times. Pre Recording
    Rec. Quality
    I Frame Inter.
    Resolution
    Alarm Spot
    Stream Type
    Terminal Input
    Frame RateThe time period for pre recording can differ according to the order of
    recording start. The minimum time period is 5 seconds. (Changeable with
    I Frame Inter., Rec. Quality, and Stream Type)
    When changing this setting, it is necessary to stop recording and discon-
    nect all network connections.
    Note:When Pre Recording is set at On, the pre-recorded image data
    may be separated to different data groups.
    If settings of Rec. Quality, I Frame Inter., Stream Type, and Frame
    Rate are changed in the middle of recording, recording will stop and
    then will resume. Then the setting values become effective.
    If recording is not stopped, the new setting becomes effective after the
    lapse of the time period preset with RECORD LENGTH.
    Playback is delayed if the setting value for I Frame Inter. is too high. We
    recommended using a default value. When changing this setting, it is
    necessary to stop recording and disconnect the network connections.
    Implement the settings of I Frame Inter. after the pre-recording setting
    has been set at OFF.
    Resolution of image data output from the VGA interface
    When an alarm goes off, the screen of the occurring alarm is displayed in
    the single-spot mode.
    When the setting is made at VBR, there may be a difference in recording
    length. If the recording time need be in higher preference, the setting
    should be made at CBR. If screen changes seem to be extreme, the set-
    ting made at VBR is preferable.
    N.O.: Alarm is started with a low-level signal.
    N.C.: Alarm is started with a high-level signal.
    The frame rate set at Full is 25 frames/second.On/Off     Off
    SP Fine/Fine/Good/
    Normal/Extended
    Normal
    01 - 15
    04
    800 x 600 or 1024 x 768
    [800 x 600]
    On/Off     Off
    CBR/VBR
    CBR
    N.O./N.C.
    N.O.
    34
    System setup (SYSTEM SETUP)
    Power On Rec. Recording will automatically start when the power is turned on. On/Off
    Off
    Seq. Dwell Sequential changeover time intervals. 02 - 30, 05
    Video Format
    Overwrite
    Status Display
    Keylock Time
    Keylock Buzz
    Alarm BuzzThe video output format is fixed to the NTSC system. Therefore, the user
    cannot set the settings.
    Even when On is selected for Overwrite, recording will not be per-
    formed to protect data from overwriting for the days set on Rec. Reserve
    of CAMERA SETUP unless the set days have passed.
    It is possible to conceal information such as the channel name that is dis-
    played on the screen.
    Even after the lapse of the preset time, the key lock does not function if
    recording data is being backed up.
    After the lapse of the preset time counted after the completion of record-
    ing data backup, the key will be automatically locked.
    When setting is made at On and a password is wrongly keyed in three
    times continuously, the buzzer begins to sound for one minute.
    Buzzer On/Off is set up.NTSC
    On/Off
    On
    All/Stat/None/Name
    All
    005 - 999     600
    On/Off     On
    On/Off     Off 
    						
    							35
    Disk information (DISK INFORMATION)
    In regard to hard disc initialization and hard disc index
    recovery, refer to 3.4 herein.  
    Reboot system (REBOOT SYSTEM)
    (1) Press the [MENU] button. WJ-RT208 SETUP MENU
    appears. Move the cursor to SYSTEM MANAGEMENT
    and press the [SET] button. (Refer to steps (1) and (2)
    in 3.1.1.)
    (2) Move the cursor to REBOOT SYSTEM and press the
    [SET] button.
    (3) The confirmation dialog box will be displayed.
    (4) Move the cursor to [OK] and press the [SET] button. 
    Picture adjustment (PICTURE ADJUST)
    (1) Select the desired channel to be adjusted by using the
    direction button (up/down) or the appropriate numeric
    button.
    The image frame of the selected channel (camera)
    blinks.
    (2) Press the [MENU] button. WJ-RT208 SETUP MENU
    appears. Move the cursor to SYSTEM MANAGEMENT
    and press the [SET] button. 
    (Refer to steps (1) and (2) in 3.1.1.)
    (3) Move the cursor to PICTURE ADJUST and press the
    [SET] button.(4) Move the cursor to the item to adjust and change the
    numeric value with the direction button (right/left).
    Note:During playback on Channel 1, the screen setup
    cannot be used.
    (5) When adjustment is completed, move the cursor to
    [Return], and press the [SET] button. The newly set
    conditions are saved.
    Note:When PICTURE ADJUST is selected in a chan-
    nel where no input signals are available.
    Time & date (TIME & DATE)
    Refer to 1.4 for the system’s time period.
    Version (VERSION)
    (1) Press the [MENU] button. WJ-RT208 SETUP MENU
    appears. Move the cursor to SYSTEM MANAGEMENT
    and press the [SET] button. (Refer to steps (1) and (2)
    in 3.1.1.)
    (2) Move the cursor to VERSION and press the [SET] but-
    ton.
    The current software version of this unit is displayed.
    Note:Refer to the Network Operating Instructions for
    the software upgrade.
        SYSTEM MANAGEMENT
    SYSTEM SETUP 
    DISK INFORMATION 
    REBOOT SYSTEM 
    PICTURE ADJUST 
    TIME & DATE 
    VERSION 
    OKREBOOT SYSTEM
    Cancel Do you really want to 
    reboot system ?
    CH1 PICTURE ADJUST
    Return71 Contrast
    74 Brightness
    50 Color
    65 Saturation
        SYSTEM MANAGEMENT
    SYSTEM SETUP 
    DISK INFORMATION 
    REBOOT SYSTEM 
    PICTURE ADJUST 
    TIME & DATE 
    VERSION 
    OK PICTURE ADJUST
    No.X channel has none signal, 
    cant do adjust.
    OK VERSION
    Current Version 1.30 
    						
    							36
    Stream type:CBR or VBR
    Default: CBR (If screen changes seem extreme,
    the setting made at VBR is preferable.)
    Recording date:SUN, MON, TUE, WED, THU,
    FRI, SAT, DAILY
    Two types of Period1 and/or Period2 can be set
    up for one day. 
    If the same setting is used every day, the setting
    should be made with DAILY. When all time spans
    have been set up, select On.
    Default: 00:00 - 24:00, Off
    (4) If the same setting is required for all channels, press
    [All] after completing the setting for one channel. All the
    parameters are then made identical to that setting.
    Press the [SET] button to close the prompt box.
    (5) Move the cursor to [OK] and press the [SET] button.
    Note:When trying to stop the recording by changing
    the settings in the process of the timer recording,
    recording will not stop immediately. The timer
    recording will not stop until it reaches the end time
    of the set duration for the timer recording. (When
    two durations are set, the timer recording will stop
    when it reaches the end time set later.) To stop the
    timer recording, stop recording manually after
    changing the settings for the timer recording.
    Terminal recording (TERMINAL REC)
    (1) Press the [MENU] button. WJ-RT208 SETUP MENU
    appears. Move the cursor to REC&EVENT SETUP and
    press the [SET] button. (Refer to steps (1) and (2) in
    3.1.3.)
    (2) Move the cursor to TERMINAL REC and press the
    [SET] button. 
    3.1.2 Record search (SEARCH)
    Refer to 3. 2.
    3.1.3 Recording & event setup (REC & EVENT)
    Timer recording (TIMER REC)
    (1) Press the [MENU] button. WJ-RT208 SETUP MENU
    appears.
    (2) Move the cursor to REC&EVENT SETUP and press the
    [SET] button.
    (3) Move the cursor to TIMER REC and press the [SET]
    button. The TIMER REC menu is displayed.
    Camera identification:1 - 8
    Picture quality:SP Fine/Fine/Good/Normal/Extended
    Default: Normal
    Frame rate:Full, 1/2F, 1/4F, 1/8F, 1/16F
    Default: Full
       WJ-RT208 SETUP MENU
    SYSTEM MANAGEMENT
    SEARCH
    REC&EVENT SETUP
    PTZ SETUP
    CAMERA SETUP
    COMMUNICATION SETUP
    REPORT
    USER INFORMATION
    DATA MANAGEMENT
    OK
    Current channel information 
    has been copied to all 
    channels!
           REC & EVENT
    TIMER REC
    TERMINAL REC
    VMD REC
    RECORD LENGTH
    AUDIO SELECT
    TIMER REC
    1Normal Full CBR
    SUNChannel
    MON
    TUE
    WED
    THU
    FRI
    SAT
    DAILY
    All OK Cancel00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
    00: 00 24: 00 Off 00: 00 24: 00 Off
           REC & EVENT
    TIMER REC
    TERMINAL REC
    VMD REC
    RECORD LENGTH
    AUDIO SELECT 
    						
    							37
    Video motion detector recording (VMD REC)
    (1) Press the [MENU] button. WJ-RT208 SETUP MENU
    appears. Move the cursor to REC&EVENT SETUP and
    press the [SET] button. (Refer to steps (1) and (2) in
    3.1.3.)
    (2) Move the cursor to VMD REC and press the [SET] but-
    ton.
    Camera ID:1-8
    Default: 1
    Sensitivity:01 - 99 (01 corresponds to the maximum
    sensitivity.) 
    Default: 10
    Area setup:140 grid areas can be established inde-
    pendently. 
    Default: All areas are not selected.
    Alarm output connector:0-3
    Default: 0 (0 indicates that there is no alarm signal
    output.)
    Alarm time:000-999
    Default: 030
    Rec. Interval:030-999
    Default: 060
    Camera preset position:000-256
    Default: 000
    Picture quality:SP Fine/Fine/Good/Normal/Extended
    Default: Normal
    Terminal input connector:1 - 8
    Default: 1
    Alarm output connector:0 - 3
    Default: 0 (0 indicates that there is no alarm signal
    output.)
    Alarm time:000 - 999
    Default: 030
    Rec. Interval:030 - 999
    Default: 060
    Camera preset position:000 - 256
    Default: 000
    Recording channel:0 - 8
    Default: 1
    Picture quality:SP Fine/Fine/Good/Normal/Extended
    Default: Normal
    Frame rate:Full, 1/2F, 1/4F, 1/8F, 1/16F
    Default: Full
    Stream type:CBR/VBR
    Default: CBR (If screen changes seem extreme,
    the setting made at VBR is preferable.)
    Period:Period1/Period2
    Default: 00: 00 - 24:00
    When On is selected for Period1 and/or Period2,
    alarm detection will be validated in the set period.
    Notes:
    1. When setting is completed, set Period1 and/or
    Period2 at On.
    2. For [All] operation and functions, refer to the timer
    recording explanation.
    (4) When setting is completed, move the cursor to [OK]
    and press the [SET] button.
    Note:When trying to stop the recording by changing
    the settings in the process of the terminal recording,
    recording will not stop immediately. The terminal
    recording will not stop unless time set for Rec.
    Interval has been passed. To stop the terminal
    recording, stop recording manually after changing
    the settings for the terminal recording.
    1Terminal Input
    0Alarm Output
    030Alarm Time
    060Rec. Interval
    Sec
    Sec
    000
    PTZ Preset
    1Rec. Channel
    NormalRec. Quality
    00: 00Period1
    00: 00Full CBR
    24: 00
    24: 00Off
    OnPeriod2
    All OK CancelTERMINAL REC
           REC & EVENT
    TIMER REC
    TERMINAL REC
    VMD REC
    RECORD LENGTH
    AUDIO SELECT
    Channel No.
    Sensitivity
    Area Setup
    Alarm Output
    Rec. Interval
    PTZ Preset
    Rec. Quality
    Period1
    Period21
    10
    Set
    0030 Sec
    Sec 060
    000
    Normal Full CBR
    All OK Cancel00: 00
    00: 0024: 00
    24: 00Off
    Off VMD REC 
    						
    							38
    2. While NetBackup (data backup function) is being per-
    formed using the provided software, VMD response
    may be delayed.
    Record length (RECORD LENGTH)
    (1) Press the [MENU] button. WJ-RT208 SETUP MENU
    appears. Move the cursor to REC & EVENT SETUP
    and press the [SET] button. (Refer to steps (1) and (2)
    in 3.1.3.)
    (2) Move the cursor to RECORD LENGTH and press the
    [SET] button.
    Setup enabled range:005 - 240
    Default: 15
    Note:If the RECORD LENGTH setup conditions are
    changed in the middle of recording, setting becomes
    effective at that time point.
    (3) Move the cursor to [OK] and press the [SET] button.
    Audio selection (AUDIO SELECT)
    (1) Press the [MENU] button. WJ-RT208 SETUP MENU
    appears. Move the cursor to REC & EVENT SETUP
    and press the [SET] button. (Refer to steps (1) and (2)
    in 3.1.3.)
           REC & EVENT
    TIMER REC
    TERMINAL REC
    VMD REC
    RECORD LENGTH
    AUDIO SELECT
    OK Cancel015 Time Per File MinRECORD LENGTH
    Frame rate:Full, 1/2F, 1/4F, 1/8F, 1/16F
    Default: Full
    Stream type:CBR/VBR
    Default: CBR (If screen changes seem extreme,
    the setting made at VBR is preferable.)
    Period:Period1/Period2
    Default: 00:00 - 24:00
    (The setup time for Period1 (or Period2) is dis-
    played when the VMD recording function is started.)
    Cautions:
    1. When setting is completed, set Period1 and/or
    Period2 to On.
    2. For [All] operation and functions, refer to the timer
    recording explanation.
    (3) When setting is completed, move the cursor to [Ok] and
    press the [SET] button.
    VMD Area Setup (AREA SETUP)
    (1) Move the cursor to [OK] and press the [SET] button in
    the VMD REC menu. A motion detector area setup
    screen is displayed.
    (2) Areas in green and without color are displayed on the
    screen. In the green area, the motion detector has
    already been set up, while no setting has been made in
    the colorless area. Move the cursor to a setting place
    with the direction button and press the [SET] button.
    The grid color is turned from green to colorless or from
    colorless to green, and the setup change of that grid is
    displayed.
    (3) Press the [ESC] button to save the setup conditions of
    the motion detector area. Move the cursor to [OK] and
    press the [SET] button and make settings for parame-
    ters other than those of VMD REC.
    Notes:
    1.When trying to stop the recording by changing the set-
    tings in the process of the VMD recording, recording will
    not stop immediately. The VMD recording will not stop
    unless time set for Rec. Interval has been passed. To
    stop the VMD recording, stop recording manually after
    changing the settings for the VMD  recording.
    Cursor
    The green areas 
    are where the 
    motion detection 
    has already been 
    set.The colorless areas 
    are where the motion 
    detection is not set.
           REC & EVENT
    TIMER REC
    TERMINAL REC
    VMD REC
    RECORD LENGTH
    AUDIO SELECT 
    						
    							39
    (2) Move the cursor to AUDIO SELECT and press the
    [SET] button.
    (3) Use the direction button (up/down) and move the cur-
    sor to the setting channel. The radio button is lit up and
    recording takes place when the audio signals are sent.
    Note:Even though recording is performed within the
    same time period, much more hard disk capacity is
    needed for recording with audio signals than
    recording without audio signals.
    3.1.4 PTZ setup (PTZ SETUP)
    PTZ selection (PTZ SELECT)
    For the selection of the camera, refer to 2.5 Camera
    Control. 
    Preset position information (PRESET INFORMA-
    TION)
    (1) Press the [MENU] button. Move the cursor to PTZ
    SETUP and press the [SET] button.
    (2) Move the cursor to PRESET INFORMATION on the
    PTZ SETUP dialog box and press the [SET] button. 
    Camera No.:1-8
    Default: 1 (Adjusted with the (right/left) direction
    button)
    Preset:001 - 256
    Default: 001 (Move the cursor by using the direction
    button (right or left), and enter the preset posi-
    tion number by using the numeric buttons.
    Call:Move the cursor to Call and press the [SET] but-
    ton. The camera turns to the preset position of the
    selected number.
    Note:For PTZ preset position setting, refer to 2.5.6.
    (3) When confirmation is completed, move the cursor to
    [Return] and press the [SET] button.
    3.1.5 Camera setup CAMERA SETUP 
    (1) Press the [MENU] button. WJ-RT208 SETUP MENU
    appears. 
    (2) Move the cursor to CAMERA SETUP and press the
    [SET] button.
    Camera No.:1 - 8
    Default: 1
    CH Enable:On/Off
    Default: On
    Mask Area:Refer to note 4 below.
    Mask Enable:On/Off
    Default: Off
    PTZ Protocol: PANASONIC/TYPE1/TYPE2/TYPE3/
    TYPE4
    Default: PANASONIC
    Rec. Reserve:000 - 200
    Default: 000
    OK Audio1AUDIO SELECT
    Cancel Audio2 Audio3 Audio4
    Audio5 Audio6 Audio7 Audio8
            PTZ SETUP
    PTZ SELECT 
    PRESET INFORMATION
    PRESET INFORMATION
    Return1 Camera
    001 Preset
    Call
       WJ-RT208 SETUP MENU
    SYSTEM MANAGEMENT
    SEARCH
    REC&EVENT SETUP
    PTZ SETUP
    CAMERA SETUP
    COMMUNICATION SETUP
    REPORT
    USER INFORMATION
    DATA MANAGEMENT
    CAMERA SETUP 
    1 Channel No. 
    On CH Enable 
    Set Mask Area 
    Off Mask Enable
    PANASONIC PTZ Protocol
    000
    All OK Cancel Rec. Reserve
    Channel Name CH1Days 
    						
    							40
    Channel Name:Indicates the correlation between the
    camera title and serial number. Channel name can
    be changed using the provided software.
    Cautions:For the [All] operation and functions, refer to the
    timer recording explanation.
    Notes:
    1. CH Enable of channel 1 cannot be set at Off. During
    playback in channel 1, it is impossible to set up its
    masking area.
    Mask Enable:
    On:Used to enable masking area setup. The masked
    area will not be displayed and recorded (Black
    screen will be recorded.).
    Off:The masking function is not effective.
    2. During operation in sequence mode, CH Enable can-
    not be set up.
    3. When the setup value for Rec. Reserve exceeds one
    day, the screen data for a maximum of preset number
    of days + 4 hours can be reserved.
    4. Mask Area can be set up with the procedures speci-
    fied below.
    Move the cursor to Set of Mask Area and press the
    [SET] button. The masking area setup screen is then
    opened.
    a) The red cursor in the above diagram indicates the
    starting position and the black cursor indicates the
    ending position. When the direction button is used,
    it is possible to move both the red and black cur-
    sors simultaneously throughout the area. It is also
    possible to move the black cursor only to adjust the
    area size. Determine if you make a control mode
    changeover by pressing the [SET] button, moving
    the red and black cursors at the same time, or mov-
    ing the black cursor only.
    b) When Numeral 1 is pressed, the profile of the mask-
    ing area is displayed. When 2 is pressed, all the
    area is embedded.
    3.1.6 Communication setup (COMMUNICA-
    TION SETUP)
    Network setup (NETWORK SETUP)
    Move the cursor to COMMUNICATION SETUP on WJ-
    RT208 SETUP MENU and press the [SET] button.
    Move the cursor to NETWORK SETUP and press the [SET]
    button.
    IP Address:IP address given to this unit
    Subnet Mask:Subnet mask for this unit
    Gateway:Gateway address for this unit
    Server Port:Port number of  this unit
    Protocol:Communication protocol
    Alarm Center IP:IP address of the PC on which the
    Alarm Center is installed
    Alarm Port:Communication port number of the alarm
    center, 1024 - 9999
    Default: [4000]
    Alarm Enable:On or Off
    Default: Off
    Line Speed:Communication speed of the network card
    is set up to match network communications.
    Notes:
    1. In regard to initial setting and setup enabled range,
    refer to Parameters and initial setup values for the
    setup menu.
    2. It is necessary to restart the unit after changing the set-
    tings.
    Mask area
    Start position
    End position
       COMMUNICATION SETUP
    NETWORK SETUP
    RS485 SETUP
    DATA PORT SETUP
    OKNETWORK SETUP
    192.168.000.088 IP Address
    Cancel
    255.255.255.000 Subnet Mask
    192.168.000.088 Gateway
    2000 Server Port
    TCP Protocol
    192.168.000.188 Alarm Center IP
    4000 Alarm Port
    Off Alarm Enable
    Auto Mode Line Speed 
    						
    All Panasonic manuals Comments (0)