11 Connections Menuj1 Function Tx Rx Direct Menuj5 Outputj1 RSj232C RSj422 When the settings are completed, press the key (i) once again to exit the menu settings. START2 MENU+ Receiving system connection procedure 1. Connect the AW-PS301 AC adapter to the DC 12V IN connector on this adapter. 3.Connect the telephone line to the line input jack on the modem. 5.Set the power switch on the AW-DU600 to ON. 7.Set the power switch on the modem and the pan-tilt head to ON. 8.“OK” appears on the LCD panel. 6.Dial Up Adapter settings 1Set this adapter to receive mode. Press the key (i) to open the menu settings. When “Menu-1 Function” appears on the LCD panel, use the ! #keys and select Rx (receive mode). STOPSTART START2MENU+ 2Select the pan-tilt head system control. Press the key (i) to change the menu setting item. When “Menu-5 Output-1” appears on the LCD panel, use the ! #keys and select RS-2332C or RS-422 according to operating conditions. STOPSTART START2MENU+ 4.Connect the pan-tilt head to this adapter. OIf the connection distance between this adapter and the AW-PH300A pan-tilt-head is 10 m or less, use the AW-CA28T9 (10 m) cable to connect the RS- 232C CONTROL OUT connector on this adapter to the P/T CONTROL IN connector on the AW-PH300A. OIf the connection distance between this adapter and the AW-PH300A pan-tilt-head is more than 10 m, use an RS-232C/RS-422 converter between the RS-422 CONTROL OUT connector on this adapter to the P/T CONTROL IN connector on the AW-PH300A when performing the connection. OWhen the AW-PH350 pan-tilt-head is used, use a 10 BASE-T cable to connect the RS-422 CONTROL OUT connector on this adapter to the CONTROL IN IP/RP connector on the AW-PH350. When an AW-RP301 or AW-RP501 is used as the controller, connect the pan-tilt head to the P1 CONTROL OUT connector on this adapter. 2.Connect the TO MODEM connector to the RS-232C connector on the modem using the RS-232C cable provided with the modem. Mode : Receiver OK Mode : Receiver j jj jj j If the modem is not connected correctly, [---] will appear on the LCD panel.
12 Connections 0123456789 1: Press Start Making a call Make a call from the AW-DU600 of the transmitting system. 2.Use the number keys on this adapter to enter the desired number. The telephone number entered appears on the top section of the LCD panel. While the telephone line is being connected, none of the operating keys on the adapters will function except for the STOP key on the transmitting side. 1.Turn on the power to all units. 3.After entering the telephone number, press the START key. When the connection is initiated, “Calling” appears on the LCD panel. When the connection is established, “Connect” appears on the LCD panel and control of the pan-tilt head system from the control panel is possible. The message appearing on the LCD panel may differ, depending on the modem used. 4.Control the pan-tilt head system from the control panel. When an AW-RP605 is being used as the control panel, set the OPERATE switch to ON to control the pan-tilt head system. OWhen an AW-RP505 or AW-RP605 is being used as the control panel, it is possible to switch the receiving pan-tilt head system using the CONTROL button on the control panel. OIf the OPERATE switch on the AJ-RP605 is set to ON before the telephone line is connected, “NO CONNECT” is displayed on the LCD panel. 5.After control of the pan-tilt head is completed, press the STOP key. “Hang Up” appears on the LCD display and the telephone line is cut. Once the line is cut, “Press Start” appears on the LCD panel. When ON has been selected for the “Menu-7 Pw-Off” setting, the power to the pan-tilt head will turn off at the same time as the telephone line is cut. When OFF has been selected for the “Menu-7 Pw-Off” setting, the power to the pan-tilt head will remain on when the telephone line is cut. If the POWER switch or OPERATE switch on the control panel is set to OFF before the telephone line is cut, the power to the pan-tilt head will turn off regardless of the “Menu-7 Pw-Off” setting. If the wrong number is entered by mistake, press the DELETE key (i) to delete 1 digit at a time, starting from the number entered last. Press the CLEAR key (i) to delete the whole number at once. START# 0# !Telephone number entered
13 Connections $Direct mode Control the pan-tilt head system directly using this adapter:1. AW-DU600 AW-PS301 AW-CA50T29 (composite) AW-CA50C29 (component) AW-PH350 AW-PS300 10 Base-T cableConvertible camera
14 Connections Connection procedure 2(:): Up 8(;): Down 4(!): Left 6(#): Right 1 (TELE): Zoom in 7 (WIDE): Zoom out 3 (FAR): Focus (long-distance) 9 (NEAR): Focus (close-up) 5 (BAR): Color bar output 0 (CAM): Camera thru output 3Select the pan-tilt head system to be controlled. Press the key (i) to change the menu setting item. When “Menu-6 Output-2” appears on the LCD panel, use the ! #keys and select P1, P2, P3, P4 or P5. STOPSTART START2MENU+ When the settings are completed, press the key (i) once again to exit the menu settings. START2 MENU+ START 1M12M2 0DEL CAM 5M5 TELE3M3 FA R 78WIDE9NEAR 4M4MENU CLEARSTOP MENURECALL 6 BAR 4.When the settings are completed, turn the power of the AW-DU600 off and then back on again. The power of the pan-tilt-head system turns on and operation is possible. 5.The pan-tilt head system can be controlled in the following ways using the operating keys on this adapter. Menuj6 Output-2 P1 P2 P3 P4 P5 2Set the CONTROL OUT connector according to the type of pan-tilt connected and the connection distance. Press the key (i) to change the menu setting item. When “Menu-5 Output-1” appears on the LCD panel, use the ! #keys and select RS-2332C or RS-422 according to the pan-tilt head system to be connected. STOPSTART START2MENU+ 1.Connect the pan-tilt head system to the CONTROL OUT connector on this adapter. 2.Turn on the power to this adapter and the pan-tilt head system. 3.Dial Up Adapter settings 1Set this adapter to direct mode. Press the key (i) to open the menu settings. When “Menu-1 Function” appears on the LCD panel, use the ! #keys and select Direct (direct mode). STOPSTART START2MENU+ Menuj1 Function Tx Rx Direct Menuj5 Output-1 RSj232C RSj422
15 Connections AW-DU600 Control panelAW-PS301 AW-PS301AW-CA50T29 AW-PH350 AW-PS300 10 Base-T cableConvertible camera AW-DU600AW-PS301 PC AW-CA50T29 AW-CA50T9 AW-PH350 AW-PS300 10 Base-T cableConvertible camera Control the pan-tilt head system using a control panel or PC:2. Coaxial cable (5C-2V) 10Base-T cable AW-RP605 cannot be used as the control panel with direct mode.
16 Connections 2Select the connector for input of control signals from the controller. Press the key (i) to change the menu setting item. “Menu-4 Input” appears on the LCD panel. Select the CONTROL OUT connector to be used using the ! #keys. When control is to be performed from a control panel, select RS-422 and select RS-232C when it is to be performed from a PC. STOPSTART START2MENU+ When the settings are completed, press the key (i) once again to exit the menu settings. START2 MENU+ Menuj4 Input RSj232C RSj422 3Set the CONTROL OUT connector according to the type of pan-tilt connected and the connection distance. Press the key (i) to change the menu setting item. When “Menu-5 Output-1” appears on the LCD panel, use the ! #keys and select RS-232C or RS-422 according to the pan-tilt head system to be connected. STOPSTART START2MENU+ 7. 6.Set the power switch on the pan-tilt head to ON. 8.Set the POWER switch on the control panel to ON to control the pan-tilt head system. When an AW-RP505 is being used as the control panel, select the pan-tilt head system using the CONTROL button on the control panel. 9.When the POWER switch on the control panel is set to OFF after control of the pan-tilt head is completed, the power of pan-tilt head system will turn off. Connection procedure 1. Connect the AW-PS301 AC adapter to the DC 12V IN connector on this adapter. 2.Set the control panel selector switch on this adapter to B. 5.Dial Up Adapter settings 1Set this adapter to direct mode. Press the key (i) to open the menu settings. When “Menu-1 Function” appears on the LCD panel, use the ! #keys and select Direct (direct mode). STOPSTART START2MENU+ Menuj1 Function Tx Rx Direct Menuj5 Output-1 RSj232C RSj422 3. 1Connect the PAN/TILT CONTROL OUT connector on the control panel to the PAN/TILT CONTROL IN connector on this adapter using a 10 BASE-T (equivalent to UTP category 5) straight cable. The connection distance can be extended up to 500 meters. 2Connect the CAMERA CONTROL OUT connector on the control panel to the CAMERA CONTROL IN connector on this adapter using a coaxial cable (equivalent to 5C-2V). The connection distance can be extended up to 500 meters. This connection is not possible with the AW-RP301 control panel as it is not equipped with a CAMERA CONTROL OUT connector. 3When a PC is used as the control panel, connect it to the TO RCB/PC connector on this adapter. 4.Set the power switch on this adapter to ON.
17 START 1 M12 M2 0 DEL CAM 5 M5 TELE 3 M3 FA R 78 WIDE9 NEAR 4 M4 MENUCLEAR STOP MENU RECALL 6 BAR Menu settings OPress the key (i) and the first menu item will appear on the LCD. OPress the key (i) while a menu item is displayed on the LCD and the display will move to the next item. OPress the key (i) again and the last menu item will appear on the LCD. OPress the key (i) while a menu item is displayed on the LCD and the display will move to the previous item. OUse the ! #keys to select the setting for each menu item. STOPSTART STOP2MENUj START2MENU+ START2MENU+ START2MENU+ $How to perform menu settings $Menu items Menu-1 Function (Initial setting: Tx)Dial up adapter mode settings Telephone line settings This is when the telephone line to be used is a tone line. Tone Pulse External line transmission number settings None 0 and 9 andThis is when the telephone line to be used is a pulse line. This is for when an external line transmission number is not required. This is for when 0 is to be transmitted via a PBX. This is for when 9 is to be transmitted via a PBX. This is for when this adapter is to be used as the transmitting system. Tx Rx DirectThis is for when this adapter is to be used as the receiving system. This is for when this adapter is to be used in direct mode (i.e. when a telephone line is not to be used). Menu-2 Modulate (Initial setting: Tone) Menu-3 PBX (Initial setting: None) The following items are only displayed when this adapter is in Tx mode. Yes No Power control setting for the pan-tilt head system when the telephone line is cut The power of the pan-tilt head system turns off when the line is cut. The power of the pan-tilt head system does not turn off when the line is cut. Menu-7 Pw-off (Initial setting: Yes)
18 Menu settings $Dial memory Menu-6 Output-2 (Initial setting: P1)This setting selects which pan-tilt head system is to be controlled by this adapter when this adapter is in Direct mode. The pan-tilt head system connected to the RS-232C or RS-422 P1 connector is controlled. P1 P2 P3 P4 P5The pan-tilt head system connected to the RS-232C or RS-422 P2 connector is controlled. The pan-tilt head system connected to the RS-232C or RS-422 P3 connector is controlled. The pan-tilt head system connected to the RS-232C or RS-422 P4 connector is controlled. The pan-tilt head system connected to the RS-232C or RS-422 P5 connector is controlled. This adapter’s dial memory function enables up to 5 specific telephone numbers to be stored. ORegistering a telephone number 1. Enter the number using the operating keys on this adapter. 2. While pressing the key, press one of the dial memory registration keys from (M1) through (M5) into which the number is to be entered. 3. “Writing Memory 2” (2is the dial memory number) appears on the LCD panel and the telephone number is stored. 51 # OUsing a dial memory to make a call 1. Press the key (i). 2. The dial memory number (M1 to M5) entered appears on the LCD panel. If a telephone numbers has not been registered for the dial memory number, the LCD panel display will be blank. 3. Each time the key (i) is pressed, the dial memory number is switched. 4. Press the key to initiate the connection. START STOP#RECALL STOP#RECALL This setting selects which connector is to be used for the controller when this adapter is in Direct mode. TO RCB/PC connector (PC used for control) PAN/TILT CONTROL IN connector (control panel used for control) RS-232C RS-422 This setting selects which connectors are to be used for the pan-tilt head systems. The RS-232C CONTROL OUT connectors are used. The RS-422 connectors cannot be used in conjunction with these connectors. The RS-422 CONTROL OUT connectors are used. The RS-232C connectors cannot be used in conjunction with these connectors. RS-232C RS-422 Menu-4 Input (Initial setting:RS-232C) Menu-5 Output-1 (Initial setting: RS-422) The following items are only displayed when this adapter is in Direct mode The following item is only displayed when this adapter is in Rx mode or Direct mode OErasing a dial memory 1. Press the key (i) to erase the number displayed on the LCD panel. 2. While pressing the key, press one of the dial memory registration keys from (M1) through (M5) which is to be erased. 3. “Writing Memory 2” (2is the dial memory number) appears on the LCD panel and the telephone number is erased. 51 # START#CLEAR
19 Attaching the rack mounting adapters Changing the position of the rear panel To install the adapter in a rack, use the rack mounting adapters and four of the mounting screws (M4) supplied. 1. Remove the three screws from the bottom panel and remove the blank panel. 2. Remove the three screws from the rear panel and remove the rear panel.3. Use the three screws to firmly secure the rear panel where the blank panel was removed from the bottom panel. Take care not to catch the internal wiring when reattaching the panels. RS-232C CONTROL OUT P5 P4 P3 P2 P1 P5 P4 P3 P2 PAN/TILT CONTROL INCAMERA CONTROL INGND DC 12V IN TO RCB/PC A B P1TO CAMERA & PAN/TILT HEAD TO MODEM RS-422 CONTROL OUTTO CAMERA & PAN/TILT HEADTO CONTROL PANEL OUT PUT IN PUT 4. Use the three screws to firmly secure the blank panel where the rear panel was removed. RS-232C CONTROL OUT P5 P4 P3 P2 P1 P5 P4 P3 P2 PAN/TILT CONTROL INCAMERA CONTROL INGND DC 12V IN TO RCB/PC A B P1TO CAMERA & PAN/TILT HEAD TO MODEM RS-422 CONTROL OUTTO CAMERA & PAN/TILT HEADTO CONTROL PANEL OUT PUT IN PUT Screws ScrewsScrews Screws Blank panel Blank panel Rack mounting adapterScrew
20 Attaching the joint angle adapter To attach the adapter to the controller, use the joint angle adapter, rack mounting adapter and mounting screws (M4 x 8) supplied. Rack mounting adapterScrew Joint angle adapters