    							11
    Connections
    Menuj1 Function
    Tx Rx Direct
    Menuj5 Outputj1
    RSj232C RSj422
    When the settings are completed, press the 
    key (i) once again to exit the menu
    settings.
    START2
    MENU+
    Receiving system connection procedure
    1.
    Connect the AW-PS301 AC adapter to the DC 12V IN
    connector on this adapter.
    3.Connect the telephone line to the line input jack on the
    modem.
    5.Set the power switch on the AW-DU600 to ON.
    7.Set the power switch on the modem and the pan-tilt
    head to ON.
    8.“OK” appears on the LCD panel.
    6.Dial Up Adapter settings
    1Set this adapter to receive mode.
    Press the  key (i) to open
    the menu settings.
    When “Menu-1 Function” appears on the LCD panel,
    use the ! #keys and select
    Rx (receive mode).
    STOPSTART
    START2MENU+
    2Select the pan-tilt head system control.
    Press the  key (i) to change
    the menu setting item.
    When “Menu-5 Output-1” appears on the LCD panel,
    use the ! #keys and select
    RS-2332C or RS-422 according to operating
    conditions.
    STOPSTART
    START2MENU+
    4.Connect the pan-tilt head to this adapter.
    OIf the connection distance between this adapter and
    the AW-PH300A pan-tilt-head is 10 m or less, use
    the AW-CA28T9 (10 m) cable to connect the RS-
    232C CONTROL OUT connector on this adapter to
    the P/T CONTROL IN connector on the AW-PH300A.
    OIf the connection distance between this adapter and
    the AW-PH300A pan-tilt-head is more than 10 m, use
    an RS-232C/RS-422 converter between the RS-422
    CONTROL OUT connector on this adapter to the P/T
    CONTROL IN connector on the AW-PH300A when
    performing the connection.
    OWhen the AW-PH350 pan-tilt-head is used, use a 10
    BASE-T cable to connect the RS-422 CONTROL
    OUT connector on this adapter to the CONTROL IN
    IP/RP connector on the AW-PH350.
    When an AW-RP301 or AW-RP501 is used as the
    controller, connect the pan-tilt head to the P1
    CONTROL OUT connector on this adapter.
    2.Connect the TO MODEM connector to the RS-232C
    connector on the modem using the RS-232C cable
    provided with the modem.
    Mode : Receiver
    OK
    Mode : Receiver
    j jj
    jj
    j
    If the modem is not connected correctly, [---] will appear
    on the LCD panel. 
    						
    							12
    Connections
    0123456789
    1: Press Start Making a call
    Make a call from the AW-DU600 of the transmitting
    system.
    2.Use the number keys on this adapter to enter the
    desired number.
    The telephone number entered appears on the top
    section of the LCD panel.
    
    While the telephone line is being connected, none of the
    operating keys on the adapters will function except for
    the STOP key on the transmitting side.
    1.Turn on the power to all units.
    3.After entering the telephone number, press the
    START key.
    When the connection is initiated, “Calling” appears on
    the LCD panel.
    When the connection is established, “Connect” appears
    on the LCD panel and control of the pan-tilt head
    system from the control panel is possible.
    
    The message appearing on the LCD panel may differ,
    depending on the modem used.
    4.Control the pan-tilt head system from the control
    panel.  
    When an AW-RP605 is being used as the control panel,
    set the OPERATE switch to ON to control the pan-tilt
    head system.
    
    OWhen an AW-RP505 or AW-RP605 is being used as
    the control panel, it is possible to switch the receiving
    pan-tilt head system using the CONTROL button on
    the control panel.
    OIf the OPERATE switch on the AJ-RP605 is set to ON
    before the telephone line is connected, “NO
    CONNECT” is displayed on the LCD panel.
    5.After control of the pan-tilt head is completed, press the
    STOP key.
    “Hang Up” appears on the LCD display and the
    telephone line is cut.
    Once the line is cut, “Press Start” appears on the LCD
    panel.
    When ON has been selected for the “Menu-7 Pw-Off”
    setting, the power to the pan-tilt head will turn off at the
    same time as the telephone line is cut.  When OFF has
    been selected for the “Menu-7 Pw-Off” setting, the
    power to the pan-tilt head will remain on when the
    telephone line is cut.
    
    If the POWER switch or OPERATE switch on the
    control panel is set to OFF before the telephone line is
    cut, the power to the pan-tilt head will turn off regardless
    of the “Menu-7 Pw-Off” setting. If the wrong number is entered by mistake, press the
    DELETE key (i) to delete 1 digit at a time,
    starting from the number entered last. Press the CLEAR
    key (i) to delete the whole number at
    once.
    START#
    0#
    !Telephone number entered 
    						
    							13
    Connections
    $Direct mode
    Control the pan-tilt head system directly using this adapter:1.
    AW-DU600
    AW-PS301
    AW-CA50T29 (composite)
    AW-CA50C29 (component)
    AW-PH350
    AW-PS300 10 Base-T cableConvertible camera 
    						
    							14
    Connections
    Connection procedure
    2(:): Up
    8(;): Down
    4(!): Left
    6(#): Right
    1 (TELE): Zoom in
    7 (WIDE): Zoom out
    3 (FAR): Focus (long-distance)
    9 (NEAR): Focus (close-up)
    5 (BAR): Color bar output
    0 (CAM): Camera thru output
    3Select the pan-tilt head system to be controlled.
    Press the  key (i) to change
    the menu setting item.
    When “Menu-6 Output-2” appears on the LCD panel,
    use the ! #keys and select
    P1, P2, P3, P4 or P5.
    STOPSTART
    START2MENU+
    When the settings are completed, press the  
    key (i) once again to exit the menu
    settings.
    START2
    MENU+
    START
    1M12M2
    0DEL
    CAM
    5M5
    TELE3M3
    FA R
    78WIDE9NEAR
    4M4MENU
    CLEARSTOP
    MENURECALL
    6
    BAR
    4.When the settings are completed, turn the power of the
    AW-DU600 off and then back on again.
    The power of the pan-tilt-head system turns on and
    operation is possible.
    5.The pan-tilt head system can be controlled in the
    following ways using the operating keys on this adapter.
    Menuj6 Output-2
    P1 P2 P3 P4 P5
    2Set the CONTROL OUT connector according to the
    type of pan-tilt connected and the connection
    distance.
    Press the  key (i) to change
    the menu setting item.
    When “Menu-5 Output-1” appears on the LCD panel,
    use the ! #keys and select
    RS-2332C or RS-422 according to the pan-tilt head
    system to be connected.
    STOPSTART
    START2MENU+
    1.Connect the pan-tilt head system to the CONTROL
    OUT connector on this adapter.
    2.Turn on the power to this adapter and the pan-tilt head
    system.
    3.Dial Up Adapter settings
    1Set this adapter to direct mode.
    Press the  key (i) to open
    the menu settings.
    When “Menu-1 Function” appears on the LCD panel,
    use the ! #keys and select
    Direct (direct mode).
    STOPSTART
    START2MENU+
    Menuj1 Function
    Tx Rx Direct
    Menuj5 Output-1
    RSj232C RSj422 
    						
    							15
    Connections
    AW-DU600
    Control
    panelAW-PS301
    AW-PS301AW-CA50T29
    AW-PH350
    AW-PS300 10 Base-T cableConvertible camera
    AW-DU600AW-PS301 PC
    AW-CA50T29 AW-CA50T9
    AW-PH350
    AW-PS300 10 Base-T cableConvertible camera
    Control the pan-tilt head system using a control panel or PC:2.
    Coaxial cable (5C-2V)
    10Base-T cable
    
    AW-RP605 cannot be used as the control panel with direct mode. 
    						
    							16
    Connections
    2Select the connector for input of control signals from
    the controller.
    Press the  key (i) to change
    the menu setting item.
    “Menu-4 Input” appears on the LCD panel.
    Select the CONTROL OUT connector to be used
    using the ! #keys.
    When control is to be performed from a control panel,
    select RS-422 and select RS-232C when it is to be
    performed from a PC.
    STOPSTART
    START2MENU+
    When the settings are completed, press the 
    key (i) once again to exit the menu
    settings.
    START2
    MENU+
    Menuj4 Input
    RSj232C RSj422
    3Set the CONTROL OUT connector according to the
    type of pan-tilt connected and the connection
    distance.
    Press the  key (i) to change
    the menu setting item.
    When “Menu-5 Output-1” appears on the LCD panel,
    use the ! #keys and select
    RS-232C or RS-422 according to the pan-tilt head
    system to be connected.
    STOPSTART
    START2MENU+
    7. 6.Set the power switch on the pan-tilt head to ON.
    8.Set the POWER switch on the control panel to ON to
    control the pan-tilt head system. When an AW-RP505 is
    being used as the control panel, select the pan-tilt head
    system using the CONTROL button on the control
    panel.
    9.When the POWER switch on the control panel is set to
    OFF after control of the pan-tilt head is completed, the
    power of pan-tilt head system will turn off.
    Connection procedure
    1.
    Connect the AW-PS301 AC adapter to the DC 12V IN
    connector on this adapter.
    2.Set the control panel selector switch on this adapter to
    B.
    5.Dial Up Adapter settings
    1Set this adapter to direct mode.
    Press the  key (i) to open
    the menu settings.
    When “Menu-1 Function” appears on the LCD panel,
    use the ! #keys and select
    Direct (direct mode).
    STOPSTART
    START2MENU+
    Menuj1 Function
    Tx Rx Direct
    Menuj5 Output-1
    RSj232C RSj422 3.
    1Connect the PAN/TILT CONTROL OUT connector
    on the control panel to the PAN/TILT CONTROL IN
    connector on this adapter using a 10 BASE-T
    (equivalent to UTP category 5) straight cable.
    The connection distance can be extended up to 500
    meters.
    2Connect the CAMERA CONTROL OUT connector on
    the control panel to the CAMERA CONTROL IN
    connector on this adapter using a coaxial cable
    (equivalent to 5C-2V).
    The connection distance can be extended up to 500
    meters.
    
    This connection is not possible with the AW-RP301
    control panel as it is not equipped with a CAMERA
    CONTROL OUT connector.
    3When a PC is used as the control panel, connect it to
    the TO RCB/PC connector on this adapter.
    4.Set the power switch on this adapter to ON. 
    						
    							17
    START
    1
    M12
    M2
    0
    DEL
    CAM 5
    M5
    TELE
    3
    M3
    FA R
    78
    WIDE9
    NEAR
    4
    M4
    MENUCLEAR
    STOP
    MENU
    RECALL
    6
    BAR
    Menu settings
    OPress the  key (i) and the first
    menu item will appear on the LCD.
    OPress the  key (i) while a menu
    item is displayed on the LCD and the display will move to
    the next item.
    OPress the  key (i) again and the
    last menu item will appear on the LCD.
    OPress the  key (i) while a menu
    item is displayed on the LCD and the display will move to
    the previous item.
    OUse the ! #keys to select the
    setting for each menu item.
    STOPSTART
    STOP2MENUj
    START2MENU+
    START2MENU+
    START2MENU+
    $How to perform menu settings
    $Menu items
    Menu-1 Function
    (Initial setting: Tx)Dial up adapter mode settings
    Telephone line settings
    This is when the telephone line to be used is a tone line. Tone
    Pulse
    External line transmission number settings
    None
    0 and
    9 andThis is when the telephone line to be used is a pulse line.
    This is for when an external line transmission number is not required.
    This is for when 0 is to be transmitted via a PBX.
    This is for when 9 is to be transmitted via a PBX. This is for when this adapter is to be used as the transmitting system. Tx
    Rx
    DirectThis is for when this adapter is to be used as the receiving system.
    This is for when this adapter is to be used in direct mode (i.e. when a
    telephone line is not to be used).
    Menu-2 Modulate
    (Initial setting: Tone)
    Menu-3 PBX
    (Initial setting: None)
    The following items are only displayed when this adapter is in Tx mode.
    Yes
    No Power control setting for the pan-tilt head system when the telephone line is cut
    The power of the pan-tilt head system turns off when the line is cut.
    The power of the pan-tilt head system does not turn off when the line is cut. Menu-7 Pw-off
    (Initial setting: Yes) 
    						
    							18
    Menu settings
    $Dial memory
    Menu-6 Output-2
    (Initial setting: P1)This setting selects which pan-tilt head system is to be controlled by this adapter when this
    adapter is in Direct mode.
    The pan-tilt head system connected to the RS-232C or RS-422 P1 connector is
    controlled. P1
    P2
    P3
    P4
    P5The pan-tilt head system connected to the RS-232C or RS-422 P2 connector is
    controlled.
    The pan-tilt head system connected to the RS-232C or RS-422 P3 connector is
    controlled.
    The pan-tilt head system connected to the RS-232C or RS-422 P4 connector is
    controlled.
    The pan-tilt head system connected to the RS-232C or RS-422 P5 connector is
    controlled.
    This adapter’s dial memory function enables up to 5 specific
    telephone numbers to be stored.
    ORegistering a telephone number
    1. Enter the number using the operating keys on this
    adapter.
    2. While pressing the  key, press one of the dial memory
    registration keys from  (M1) through  (M5) into
    which the number is to be entered.
    3. “Writing Memory 2” (2is the dial memory number)
    appears on the LCD panel and the telephone number is
    stored.
    51
    #
    OUsing a dial memory to make a call
    1. Press the  key (i).
    2. The dial memory number (M1 to M5) entered appears on
    the LCD panel.
    If a telephone numbers has not been registered for the
    dial memory number, the LCD panel display will be blank.
    3. Each time the  key (i) is
    pressed, the dial memory number is switched.
    4. Press the  key to initiate the connection.
    START
    STOP#RECALL
    STOP#RECALL
    This setting selects which connector is to be used for the controller when this adapter is in Direct mode.
    TO RCB/PC connector (PC used for control)
    PAN/TILT CONTROL IN connector (control panel used for control) RS-232C
    RS-422
    This setting selects which connectors are to be used for the pan-tilt head systems.
    The RS-232C CONTROL OUT connectors are used.
    The RS-422 connectors cannot be used in conjunction with these
    connectors.
    The RS-422 CONTROL OUT connectors are used.
    The RS-232C connectors cannot be used in conjunction with these
    connectors. RS-232C
    RS-422 Menu-4 Input
    (Initial setting:RS-232C)
    Menu-5 Output-1
    (Initial setting: RS-422)
    The following items are only displayed when this adapter is in Direct mode
    The following item is only displayed when this adapter is in Rx mode or Direct mode
    OErasing a dial memory
    1. Press the  key (i) to erase the
    number displayed on the LCD panel.
    2. While pressing the  key, press one of the dial memory
    registration keys from  (M1) through  (M5) which is
    to be erased.
    3. “Writing Memory 2” (2is the dial memory number)
    appears on the LCD panel and the telephone number is
    erased.
    51
    #
    START#CLEAR 
    						
    							19
    Attaching the rack mounting adapters
    Changing the position of the rear panel
    To install the adapter in a rack, use the rack mounting adapters and four of the mounting screws (M4) supplied.
    1. Remove the three screws from the bottom panel and
    remove the blank panel.
    2. Remove the three screws from the rear panel and
    remove the rear panel.3. Use the three screws to firmly secure the rear panel
    where the blank panel was removed from the bottom
    panel.
    Take care not to catch the internal wiring when reattaching the panels.
    RS-232C CONTROL OUT
    P5 P4 P3 P2 P1
    P5 P4 P3 P2 PAN/TILT
    CONTROL INCAMERA
    CONTROL INGND DC 12V IN TO RCB/PC
    A
    B
    P1TO CAMERA & PAN/TILT HEAD TO MODEM
    RS-422 CONTROL OUTTO CAMERA & PAN/TILT HEADTO CONTROL PANEL
    OUT PUT
    IN PUT
    4. Use the three screws to firmly secure the blank panel
    where the rear panel was removed.
    RS-232C CONTROL OUT
    P5 P4 P3 P2 P1
    P5 P4 P3 P2 PAN/TILT
    CONTROL INCAMERA
    CONTROL INGND DC 12V IN TO RCB/PC
    A
    B
    P1TO CAMERA & PAN/TILT HEAD TO MODEM
    RS-422 CONTROL OUTTO CAMERA & PAN/TILT HEADTO CONTROL PANEL
    OUT PUT
    IN PUT
    Screws
    ScrewsScrews
    Screws Blank panel
    Blank panel Rack mounting adapterScrew 
    						
    							20
    Attaching the joint angle adapter
    To attach the adapter to the controller, use the joint angle adapter, rack mounting adapter and mounting screws (M4 x 8)
    supplied.
    Rack mounting adapterScrew
    Joint angle adapters 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Dial Up Adapter Aw Du600p Operating Instructions