Panasonic Dial Up Adapter Aw Du600p Operating Instructions
Here you can view all the pages of manual Panasonic Dial Up Adapter Aw Du600p Operating Instructions . The Panasonic manuals for Adapter are available online for free. You can easily download all the documents as PDF.
Page 1
Model AW- P Before attempting to connect, operate or adjust this product, please read these instructions completely. Dial Up Adapter
Page 2
2 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within...
Page 3
3 Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Parts and their functions . . . . . . . . . . . . . . . . . . . . . . . . . 4 Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 4
4 Parts and their functions $Control panel 21 3 4 5 1POWER indicator This lights when power is supplied to the main unit and the POWER switch is set to ON. 2POWER switch This is the unit’s power switch. 3LCD panel This displays the current statuses and menu settings. 4Operating keys These keys are used for dialing and to perform menu settings. These keys are also used to operate the pan-tilt head system in direct mode. When any key is operated with the key held down, the function indicated in red on the...
Page 5
5 6RS-232C CONTROL OUT connectors (P1 to P5) These connectors are used to connect the pan-tilt head system controlled with RS-232C. These connectors cannot be used in conjunction with the RS-422 CONTROL OUT connectors 7. 7RS-422 CONTROL OUT connectors (P1 to P5) These connectors are used to connect the pan-tilt head system controlled with RS-422. These connectors cannot be used in conjunction with the RS-232C CONTROL OUT connectors 6. 8TO MODEM connector This is used to connect the modem. Connect this...
Page 6
6 Connections Transmitting system connections Connect the control panel When an AW-RP605 is usedTurn off the power of all components before proceeding with the connections. OWhen an AW-RP301 or AW-RP501 is being used, connect the receiving pan-tilt head system to the P1 CONTROL OUT connector. OWhen an AW-RP505 or AW-RP605 is being used, it is possible to select either P1, P2, P3, P4 or P5 for the connected pan-tilt head system using the CONTROL button on the controller.OWhen an AW-RP301, AW-RP501 or...
Page 7
7 Connections Dial Up Adapter settings 1Set this adapter to transmit mode. Press the key (i) to open the menu settings. When “Menu-1 Function” appears on the LCD panel, use the ! #keys and select Tx (transmit mode). STOPSTART START2MENU+ 2Select the telephone line. Press the key (i) to change the menu setting item. When “Menu-2 Modulate” appears on the LCD panel, use the ! #keys and select Tone or Pulse according to the telephone line to be used. STOPSTART START2MENU+ 4Set whether or not to turn the...
Page 8
8 Receiving system connections Connections $Connect the pan-tilt head system to the RS-232C CONTROL OUT connector: When an AW-PH300A is used and the connection distance is 10 m or less: When an AW-PH600 is used: Telephone line Telephone line Modem Modem AW-DU600 AW-DU600AW-PS301 AW-PS301 AW-PS600 P-T CONTROLAW-CA50D15 (component) AW-CA50A15 (composite) AW-CA24U10 AW-CA16U10 CAMERA CONTROL G/L video (BNC cable) Video (BNC cable) COMPONENTAW-CA50A15 AW-PH300A AW-CH600 AW-PH600 AW-PS300 AW-CA28T9Convertible...
Page 9
9 Connections $Connect the pan-tilt head system to the RS-422 CONTROL OUT connector: Use the RS-422 connector when the AW-PH350 is to be used as the pan-tilt head or when the connection distance between this adapter and the pan-tilt head is to exceed 10 m. When an AW-PH350 is used: When an AW-PH300A is used and the connection distance is more than 10 m: Telephone line Modem AW-DU600 AW-PS301 Convertible camera Convertible camera AW-PH350 AW-PS300 10 Base-T cable 10 Base-T cableTelephone line Modem...
Page 10
10 Connections When an AW-PH600 is used and the connection distance is more than 10 m: Telephone line Modem AW-DU600 AW-PS301 AW-PS600 P-T CONTROL CAMERA CONTROL G/L video (BNC cable) Video (BNC cable) COMPONENTAW-CH600 AW-PH600 RS-232C/RS-422 converter 10 Base-T cable AC adapterAW-CA50D15 (component) AW-CA50A15 (composite) AW-CA24U10 AW-CA16U10 Refer to the Operating Instructions of the AW-PH600 for details on how to perform the connections for the AW-PH600.