Panasonic Cwxc80hu Operating Instructions Manual
Here you can view all the pages of manual Panasonic Cwxc80hu Operating Instructions Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 1
Please read these operating instructions thoroughly before using your air conditioner and keep for future reference. For U.S customers : For assistance, please call : 1-800-211-PANA(7262) or Register your product at : http://www.panasonic.com/register INSTALLATION AND OPERATING INSTRUCTIONS Room Air Conditioner Model:CW-XC80HU CW382820391J R ECONOMYFA NCOOL DRYhrF OPERA TION TEMP TEMPTIMER MODEOFF/ONFA N SPEED FA N SPEED
Page 2
2 Safety Precautions About the Controls on the Air Conditioner Features and Installation Before you call for service... FOR YOUR RECORDS Staple your receipt to this page in case you need it later. Write down the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealers Name Date Purchased Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal...
Page 3
WARNING 3 Safety PrecautionsSafety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING: This symbol indicates the possibility of death or serious injury. CAUTION:This symbol indicates the possibility of injury or damage to property only. Meanings of symbols used in this manual are as...
Page 4
4 Safety Precautions When the air filter is to be removed, do not touch the metal parts of the unit. • It may cause an injury. Do not clean the air conditioner with water. • Water may enter the unit and degrade the insulation. It may cause an electric shock. Ventilate well when used together with a stove, etc. • An oxygen shortage may occur. When the unit is to be cleaned, switch off, and turn off the breaker. • Since the fan rotates at high speed during operation, it may cause an injury. Do not put a...
Page 5
5 About the Controls on the Air Conditioner ECONOMYFA NCOOL DRY hrF OPERATION TEMP TEMP TIMERMODEOFF/ON FA N SPEEDFA N SPEED4 1 6 325 Model : CW-XC80HU About the Controls on the Air Conditioner Controls OPERATION • To turn the air conditioner ON, push the OFF/ON button. To turn the air conditioner OFF, push the button again. • This button takes priority over any other buttons. • When you first turn it on, the air conditioner is on the High cool mode and the temp. at 72°F (22°C) MODE • Evey time you push...
Page 6
OPERATION TEMP TIMER MODE FAN SPEED1 3 24 5 Model: CW-XC80HU 6 About the Controls on the Air Conditioner Remote controller OPERATION • To turn the air conditioner ON, push the button. To turn the air conditioner OFF, push the button again. • This button takes priority over any other buttons. • When you first turn it on, the air conditioner is on the High cool mode and the temp. at 72°F (22˚C). MODE • Every time you push this button, it will toggle between COOL, FAN and DRY. ON/OFF TIMER - STOPPING...
Page 7
VENT CLOSE OPEN Par tA Par tB Drain pipe Drain cap Fig. 3Fig. 2 Fig. 1 Controlled manuallyControlled manually O F F / O NO P ER A TI O NTEMP/TIMERC O O L F A N H I G H M E D L O WM O D E F A N S P E E DSETT I MERS E T / C A N C E LA I R S W I N GECONOMYh r FW i re l e s sR e m o t e C o n t ro l Remove therubber plug O F F/ O NO P E R A T I O NT E P /T IC O O L F A N H I G H M E D L O WM O E F A N S P E E DS ETTIMERS E T / C N EA I R ECONOMYFW ir e l e s sR em o t e C o n t r o l DRAIN PA NDRAIN...
Page 8
Air Filter Cleaning The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary. TO REMOVE: 1. Open the inlet grille upward by pulling out the bottom of the inlet grille or downward by pulling out the top of the inlet grille. 2. Using the tab, pull up slightly on the filter to release it and pull it down or up. 3. Clean the filter with warm, soapy water under 40°C (104°F). 4. Rinse and gently shake the water from the filter and let it dry...
Page 9
9 Features and Installation CABINET FRONT GRILLE AIR FILTER AIR INTAKE (INLET GRILLE) AIR DISCHARGE HORIZONTAL AIR DEFLECTOR (VERTICAL LOUVER) VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER) EVAPORATOR POWER CORD BASE PAN CONDENSER COMPRESSOR BRACE CONTROL BOARD REMOTE CONTROLLER E C O N O M YF ANC O O L D RYhr FO P E R AT I O N T E M P T E M PT I M E RM O D EO F F /O NF AN S P E E D F AN S P E E D ECONOMYFA NCOOL DR YhrF OPERA TION TEMP TEMPTIMER MODEO F F / O N FA N SPEED FA N SPEED Learning parts name...
Page 10
10 Features and Installation INSTALLATION 1. To prevent vibration and noise, make sure the unit is installed securely and firmly 2. Install the unit where the sunlight does not shine directly on the unit. 3. The outside of the cabinet must extend outward for at least 28cm (11) and there should be no obstacles, such as a fence or wall, within 50.8cm (20) from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling...