    							 4. Slide the chassis back into the cabinet. Reinstall the cabinet
    to the chassis by using screws.
    11.8. Noise Consideration
     • Select an installation location that can support the weight of
    the air conditioner and one that will not cause increased
    operating noise and vibration.
     • Ensure that airflow and noise from the rear side of the unit
    (outdoor) when installed do not disturb neighboring
    residents. • Obstacles placed in front of the air outlet on the rear side of
    the unit (outdoor), or coversplaced over it will cause
    excessive noise and deterioration in performance.11.9. Transferring
     • Repositioning or transfer of the air conditioner due to
    renovation or moving requires an additional service charge.
    Please consult your dealer before moving.
    12 Care and Maintenance
    Caution:
    Always turn off the air conditioner and the main power supply before unplugging the power cord to clean the unit.
    Switch off the power supply if the unit is not going to be used for a long period of time.
     • Clean the cabinet, front grille with a mild soap or detergent and lukewarm water.
     • The front intake grille can beeasily removed forcleaning purposes (referRemoval of Front Grilleprocedures).Gently wash
    it with water and a sponge.
     • The filter can be easily cleaned using a vacuum cleaner. Vacuum the front of the filter and then wash the rear with water. If it
    is badly soiled, wash with a mild household detergent.
     • Do not clean with benzene, thinner, scouringpowder or cloth soaked in caustic chemicals.
     • If the unit is extremely dirty, heat transferis less efficient and the unit maynot cool effectively. Contact Shun Hing Electric
    Service Centre Ltd. for an annual check.(Annual check is notcovered underwarranty)
     • If the air filter becomes clogged with dust, the cooling capacity will drop, and 6% of the electricity used to operate the air
    conditioner will be wasted.
    NOTE
    Do not dry the front panel or the air filter in direct sunlight. (Exposure to direct sunlight may discolour or deform the panel.)
    21 
    						
    							 1. Remove the screws in front and both sides of the chassis
    as indicated (1), (2) and (3).
     2. Release the tabs at both sides of the front grille (push in the
    cabinet and pull out the grille).Then, pull up the grille as to
    release another two tabs at the top side of the grille.
     3. Release the temperature sensor from its holder (1) and pull
    out the wire from the bushing at the cabinet (2).
     4. Pull out the unit from cabinet by holding the hand grip at the
    base pan. Remove two screws in front of the control board
    (1) & (2). Then, remove screw at the side of control board
    (3) and take out the control board side plate.
     5. Hold the horizontal vane and pull it out from the top side
    and get it out from its position.
     6. Then, remove the shaft at the bottom of the compartment.
    13 Servicing Information
    13.1. Control Board Removal Procedure
    22 
    						
    							 7. Pull out the control board as shown in figure. Then remove
    the screw as indicated (1).
     8. Release a hook as shown in figure (1) to open up the
    control board.
     • Control Board part location.
    23 
    						
    							14.1. Thermostat Characteristics
     • Mechanical Thermostat (Cooling).
    14.2. Operation Characteristics
     • Cooling Characteristics Vs. Outdoor Temperature.
    14 Technical Data
    24 
    						
    							15 Electronic Circuit / Main
    16 Electronic Circuit / Indicator Complete
    25 
    						
    							17 Electronic Circuit Diagram
    17.1. Electronic Circuit Diagram (Main Unit)
    26 
    						
    							27 
    						
    							Before using the circuit diagram, read the following carefully.
    Intake air
    temperatureTemperature
    settingDischarge air
    temperaturePipe
    temperature
    Cooling27°C16°C17°C15°C
     • Indications for resistance
     − a. K...KΩ
    b. W...WATT
    c. M...MΩ
    d. Not indicated...1/4W
     − Type
    Not indicatedCarbon resistor
    Tolerance (+-) 5%
    Metal oxide resistor
    Tolerance (+-) 1%
     • Indications for capacitor
    Unit − µ...µF
     − P...pF
    Type − Not indicated...ceramic capacitor
     − (S)...S series aluminium electrolytic capacitor
     − (Z)...Z series aluminiumelectrolytic capacitor
     − (SU)...SU series aluminium electrolytic capacitor
     − (K)...K series aluminium electrolytic capacitor
     − (P)...P seriespolyester system
     − (SXE)...SXE series aluminium electrolytic capacitor
     − (SRA)...SRA series aluminium electrolytic capacitor
     − (KME)...KME series aluminium electrolytic capacitor
     • Diode without indication...MA165
     • Circuit Diagram is subject to change without notice for
    further development.
    17.2. Electronic Circuit Diagram (Remote Control)
    17.3. How to use electronic circuit diagram
     • Voltage measurement
    Voltage has been measured with a digital tester when the fan is set at high fan speed under the following conditions without
    setting the timer.
    Use them for servicing.
    Voltage indication is in red.
    17.4. Timer Table
    NameTimeTest Mode (Shortened CN-TEST pin)Remarks
    Hour Timer1 hr.
    10 min.
    1 min.1 min.
    10 sec.
    1 sec.
    Time delay SafetyControl2 min. 58 sec.0 sec.
    Forced Operation60 sec.0 sec.
    Time Save Control7 min.42 sec.
    Freeze Prevention Control3 min.0 sec.
    Compressor Reverse Rotation Detection2 min.0 sec.
    Starting Current Control1.6 sec.0 sec.
    Powerful Operation15 min.15 sec.
    Random Auto Restart Control0 ~ 62 sec.0 ~ 6.2 sec.Add value to TimeDelay Safety Control.
    28 
    						
    							18 Exploded View
    (Note)
     • The above exploded view is for the purpose of parts disassembly and replacement.
     • The non-numbered parts are not kept as standard service parts.
    29 
    						
    							19 Replacement Part List
    Ref. No.Part Name & DescriptionQty.CW-XC90JHRemarks100Base Pan Assembly1CWD52K1058AL101Bulkhead Assembly1CWD531012L102Air Guide - Propeller Fan1CWD311018L103Bracket - Fan Motor1CWD541042L104Particular Piece - Stopper1CWD932251L105Self Tapping Screw1XTT4+8JL113Ventilation Lever1CWH221006L117Vane - Air Swing1CWE241117L121Propeller Fan1CWH001013L122Nut - Propeller Fan1CWH56032L124Holder - Capacitor (Compressor)1CWH301009L125Control Board complete1CWH14C3374L125-AControl Board (Main)1CWH102177L126Control Board (Front)1
    1CWH102178L
    CWH102177L
    127Plain Washer1CWXWE6L128Holder - Sensor1CWH321008L129Drain Plug - Base Pan1CWH4611062L135Air Guider - Blower Wheel1CWD32C1021L140Turbo Fan1CWH031004L141Nut - Turbo Fan1CWH56053142Plain Washer1CWXWH6F16L200Compressor1CWB092141
    KG3AF100-1000
    201Bushing - Compressor Mount3CWH50072202Nut - Compressor Mount3CWH4582065L203Packing - Terminal Cover1CWB811008204Holder - Overload Protector1CWH7041200L205Terminal Cover - Compressor1CWH7070221U207Nut - Terminal Cover1CWH7080300208Packing1CWB811009210Fin & Tube Condenser complete1CWB32C1245L211Strainer1CWB11101212Capillary Tube1CWB152203220Fin & Tube Evaporator complete1CWB30C1247L
    300Fan Motor1
    1
    1CWA921156
    CWA921157
    CWA921176
    301Auto Circuit Breaker1
    1CWA121064+M
    CWA121067+M
    303Capacitor - Compressor1
    1CWA312075
    DS371256CPNA0
    308Sensor Complete1CWA50C2113
    CWA50C2096
    309Control Board Cover1CWH31125L311Power Supply Cord1CWA20C2268312Air Swing Motor1CWA981079328Electronic Controller (Main)1CWA742886-WN329Electronic Controller (Indicator)1CWA742060-WN330Remote Control Complete1CWA75C2230500Front Grille Complete1CWE11C2076L501Air Filter1
    1CWD001081L
    CWE312290L
    502Particular Piece-Front Cover1
    1CWE141058L
    CWD932236L
    503Intake Grille1CWE221074L505Vane1CWE241118L510Front Grille1CWE101020L600Cabinet Complete1CWE00C1079L601Bushing2CWH51071D610Drain Pan1CWH401012L-E612Particular Plate1CWD911289L613Self Tapping Screw4XTT4-12CL702Screw - Bracket Fan Motor4XTT4+8JL707Screw - Front Grille Mount (Center)1CWH551069A710Screw - Drain Pan1XTT4D8CL715Operating Instructions1CWF563675L
     • The above parts are kept for sevenyears in accordancewith MEIservice policy.
     • However, longer lead time will be taken in supplying the non-numbered parts.
     • All parts are supplied from MEPCO, Philippines (Vendor Code: 067).
     • “O” marked parts are recommended to be kept in stock.
    30 
    						