Page 1
1 Functions 2 2 Product Specifications 4 3 Dimensions 5 4 Refrigeration Cycle Diagram 6 5 Block Diagram 6 6 Wiring Diagram 7 7 Air Conditioner Performance Evaluation 7 8 Troubleshooting Guide 8 9 Operation Details 10 10 Operating Instructions 13 © 2002 Matsushita Industrial Corp. Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. CW-XC90JH 11 Installation Instructions 18 12 Care and Maintenance 21 13 Servicing Information 22...
Page 4
2 Product Specifications UnitCW-XC90JH PhaseØSingle VoltageV220 ~ 240 FrequencyHz50 Cooling CapacitykW Btu/h2.64 ~ 2.67 9000 ~ 9100 Running CurrentA4.4 ~ 4.3 Input PowerW935 ~ 975 EERBtu/hW9.6 ~ 9.3 Starting CurrentA16.9 Compressor OutputW750 Fan Motor OutputW58 Noise LevelIndoor (High / Low)db(A)47 / 43 ~ 49 / 45 Outdoor (High / Low)db(A)57 / 53 ~ 58 / 54 Moisture RemovalL/h Pt/h1.6 3.4 Air CirculationIndoorm3/min (ft3/min)7.2 (254) Outdoorm3/min (ft3/min)11.1 (392) DimensionsHeightmm inches346...
Page 5
3 Dimensions 3.1. Top View, Front View and Side View 3.2. Unit ItemUnit: Inch (mm) A - Width17-23/32” (450) B - Height13-10/16” (346) C - Depth22-27/32” (580) D11-9/16” (293) E1-15/32” (37) F10-14/16” (276) G11-9/16” (293) 5
Page 6
4 Refrigeration Cycle Diagram ItemPressure (MPa)Temperature (°C) A2.04 ~ 2.2468 ~ 82 B1.87 ~ 2.0735 ~ 45 C0.54 ~ 0.607~13 D0.51 ~ 0.578~16 Note: Indoor temperature at 27°C (DB), 19°C(WB) and Outdoor at 35°C (DB),24°C (WB)forCooling. 5 Block Diagram 6
Page 7
6 Wiring Diagram 6.1. Resistance of Fan Motor windings and the rated Capacitor ModelCW-XC90JH ConnectionCWA921156 Blue - Yellow93.8Ω Yellow - Orange58.7Ω Brown - Yellow13.0Ω Red - Yellow143.0Ω 6.2. Resistance of Compressor windings and the rated Capacitor ModelCW-XC90JH ConnectionCWB092141 C-R3.597Ω C-S4.868Ω CapacitorCWA312075 (25µF, 370VAC) Note: Resistance at 20°C of Ambient Temperature. 7 Air Conditioner Performance Evaluation Suction & Discharge Air Temperature DifferenceCurrentDeterminationRemedy...
Page 8
8 Troubleshooting Guide Warning: Disconnect unit from electrical power supply before making any electrical checks. TroubleCheckResultCausesRemedy Fan Motor and Compressor won’t run. • Supply Voltage • Fuse Box or Circuit Breaker. • Power cord or Wiring Harness. • Temperature Setting. • Less than 10% by Rated. • Open Contacts. • Pulled loose or Shorted. • Higher than room temperature • Temporary or Permanent? • Customer Restarted unit immediately without waiting 3 minutes. • Consult ELECTRICIAN, if...
Page 9
TroubleCheckResultCausesRemedy Insufficient cooling. • Temperature Setting. • Ventilation door open. • Air filter dirty. • Location of installation. • Evaporator/Conden ser Coil obstructed. • Unit capacity for the room too small. • Temperature difference and running current. • Higher than room temperature. • Open. • Clogged or dirty. • Sunlight hitting outdoor side. • Obstacles. • Clogged or dirty. • Not satisfied. • REFER TO PERFORMANCE EVALUATION. • Reduces capacity. • Restricted air...
Page 10
9 Operation Details 9.1. Fan Mode Operation • Fan operation only. Fan inoperation according to Remote Control or Main Unit (Touch Control Panel) setting. 9.1.1. Manual Setting of Fan Speed • Basic Fan Speed can be manually adjusted (Lo or Hi) byusing the Fan Speed Selection Button/Pad at Remote Control or Main Unit (Touch Control Panel). 9.2. Cooling Mode Operation • Cooling in operation according to Remote Control or Main Unit (Touch Control Panel) setting. 9.2.1. Time Delay Safety Control (3...