Home > Panasonic > Air Conditioner > Panasonic Cw Xc181ea Cw Xc241ea Repair Manual

Panasonic Cw Xc181ea Cw Xc241ea Repair Manual

Here you can view all the pages of manual Panasonic Cw Xc181ea Cw Xc241ea Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.

Page 1

 1 Functions  2
 2 Product Specifications 
4
 3 Dimensions 
5
 4 Refrigeration Cycle Diagram 
6
 5 Block Diagram 
6
 6 Wiring Diagram  
7
 7 Air Conditioner Performance Evaluation  
8
 8 Troubleshooting Guide 
9
 9 Operation Details 
11
 10  Operating Instructions 
14
© 2002 Matsushita Industrial Corp. Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
CW-XC181EA
CW-XC241EA
 11  Installation Instructions 19
 12  Care and Maintenance 
22
 13  Servicing...

Page 2

1 Functions
1.1. Remote Control
2
CW-XC18 1EA / CW-XC24 1EA 

Page 3

1.2. Main Unit
3
CW-XC18 1EA / CW-XC2 

Page 4

2 Product Specifications
UnitCW-XC181EACW-XC241EA
PhaseØSingleSingle
VoltageV220220
FrequencyHz5050
Cooling CapacitykW
Btu/h5.28
18,0006.95
23,700
Running CurrentA9.713.7
Input PowerkW2.022.81
EERW/W2.612.47
Starting CurrentA4568
Compressor OutputkW1.72.20
Fan Motor OutputW110190
Noise LevelIndoor
(High / Low)db(A)51 / 4757 / 54
Outdoor
(High / Low)db(A)58 / 5463 / 60
Moisture RemovalL/h
Pt/h2.9
6.14.0
8.5
Air CirculationIndoorm3/min (ft3/min)13.3 (470)16.4 (580)
Outdoorm3/min (ft3/min)--...

Page 5

3 Dimensions
3.1. Top View, Front View & Side View.
3.2. Unit.
ItemUnit: Inch (mm)
A - Width26” (660)
B - Height16-7/8” (428)
C - Depth27-9/16” (700)
D1-31/32” (50)
E8-21/32” (220)
F12-19/32” (320)
G4-11/32” (110)
H13-5/32” (334)
I5-3/16” (132)
J9-7/32” (234)
K3-5/32” (80)
L12-17/32” (318)
M10-5/16” (262)
N1-21/32” (42)
O12-17/32” (318)
P2-11/16” (68)
Q9-7/16” (240)
R7-15/32” (190)
5
CW-XC18 1EA / CW-XC2 

Page 6

4 Refrigeration Cycle Diagram
CW-XC181EACW-XC241EA
ItemPressure (MPa)Temperatu re (°C)Pressure (MPa)Temperatu re (°C)
A2.0577.02.16 ~ 2.2670 ~ 86
B1.9544.72.06 ~ 2.1140 ~ 50
C0.519.50.53 ~ 0.617.5 ~ 11.5
D0.478.40.49 ~ 0.556~14
Note: Indoor temperature at 27°C (DB), 19°C (WB) and Outdoor at 35°C (DB), 24°C(WB) forCooling.
5 Block Diagram
6
CW-XC18 1EA / CW-XC24 1EA 

Page 7

6 Wiring Diagram
6.1.1. Resistance of Fan Motor windings
and the rated Capacitor.
CW-XC181EA
ConnectionCWA951127
Blue - Yellow56.0Ω
Yellow - Brown7.39Ω
Brown - Orange15.4Ω
Red - Yellow62.4Ω
CapacitorCWA312095
(5µF, 440VAC)
6.1.2. Resistance of Compressor
windings and the rated Capacitor.
CW-XC181EA
Connection2JS330D3AA02
C-R1.289Ω
C-S2.848Ω
CapacitorCWA312079
(45µF, 370VAC)
Note: Resistance at 20°C of Ambient Temperature.
6.1. CW-XC181EA
7
CW-XC18 1EA / CW-XC2 

Page 8

6.2.1. Resistance of Fan Motor windings
and the rated Capacitor
CW-XC241EA
ConnectionCWA921070
Blue - Yellow15.04Ω
Yellow - Brown2.22Ω
Brown - Orange5.69Ω
Red - Yellow20.79Ω
CapacitorCWA312096
(8µF, 400VAC)
6.2.2. Resistance of Compressor
windings and the rated Capacitor
CW-XC241EA
Connection2JS438D4CA02
C-R0.820Ω
C-S2.247Ω
CapacitorCWA312079
(45µF, 370VAC)
Note: Resistance at 20°C of Ambient Temperature.
6.2. CW-XC241EA
7 Air Conditioner Performance Evaluation
Intake & Discharge Air
Temperatu re...

Page 9

8 Troubleshooting Guide
Warning: Disconnect unit from electrical powersupply before making any electrical checks.
TroubleCheckResultCausesRemedy
Fan Motor and Compressor
won’t run. 
    • 
• •  • Supply Voltage
 
    • 
• •  • Fuse Box or Circuit
Breaker.
 
    • 
• •  • Power cord or Wiring
Harness.
 
    • 
• •  • Temperature Setting. 
    • 
• •  • Less than 10% by
Rated.
 
    • 
• •  • Open Contacts.
 
    • 
• •  • Pulled loose or Shorted.
 
    • 
• •  • Higher than room
temperature 
    • 
• •  •...

Page 10

TroubleCheckResultCausesRemedy
Insufficient cooling. 
    • 
• •  • Temperature Setting.
 
    • 
• •  • Ventilation door open.
 
    • 
• •  • Air filter dirty.
 
    • 
• •  • Location of installation.
 
    • 
• •  • Evaporator/Condenser
Coil obstructed.
 
    • 
• •  • Unit capacity for the
room too small.
 
    • 
• •  • Temperature difference
and running current. 
    • 
• •  • Higher than room
temperature.
 
    • 
• •  • Open.
 
    • 
• •  • Clogged or dirty.
 
    • 
• •  • Sunlight hitting...