Have a look at the manual Panasonic Cus9jku Operating Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2009. Unauthorized copying and distribution is a violation of law. F567334 Operating Instructions Air Conditioner Model No. Indoor Unit Single Split Outdoor Unit CS-S9JKUW CU-S9JKU CS-S12JKUW CU-S12JKU CS-S18JKU CU-S18JKU CS-S22JKU CU-S22JKU Multi Split Outdoor Unit CU-2S18JBU ENGLISH 2 ~ 9 Before operating the unit, read these operating instructions thoroughly and keep them for future reference. ESPAÑOL 10 ~ 17 Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta. QUICK GUIDEQUICK GUIDEGUÍA RÁPIDAGUÍA RÁPIDA Please register your product at : www.panasonic.com/register For assistance, please call : (866)-292-7292

2 SAFETY PRECAUTIONS To prevent personal injury, injury to others, or property damage, please comply with the following. Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below: WARNINGWARNINGThis sign warns of death or serious injury. CAUTIONCAUTION This sign warns of injury or damage to property. The instructions to be followed are classifi ed by the following symbols: This symbol denotes an action that is PROHIBITED. These symbols denote an actions that is COMPULSORY. WARNINGWARNING INDOOR UNIT AND OUTDOOR UNIT This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Please consult authorized dealer or specialist to repair, install, remove and reinstall the unit. Improper installation and handling will cause leakage, electric shock or fi re. Do not install the unit in a potentially explosive or fl ammable atmosphere. Failure to do so could result in fi re. Do not insert your fi ngers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury. Do not touch the outdoor unit during lightning, it may cause electric shock. REMOTE CONTROL Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries. Thank you for purchasing Panasonic Air Conditioner TABLE OF CONTENTSTABLE OF CONTENTS SAFETY PRECAUTIONS 2~3 MULTI AIR CONDITIONER SYSTEM 4 INDOOR UNIT 5 REMOTE CONTROL 6~7 TROUBLESHOOTING 8 INFORMATION 9 QUICK GUIDE BACK COVER NOTENOTE The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement. OPERATION CONDITIONOPERATION CONDITION Use this air conditioner under the following temperature range Temperature (˚F)Indoor *DBT *WBT COOLINGMax. 89.6 73.4 Min. 60.8 51.8 Temperature (˚F)Outdoor *DBT *WBT COOLINGMax. 109.4 78.8 Min. 60.8 51.8 * DBT: Dry bulb temperature * WBT: Wet bulb temperature

ENGLISH 3 CAUTIONCAUTION INDOOR UNIT AND OUTDOOR UNIT Do not wash the indoor unit with water, benzene, thinner or scouring powder. Do not use for other purpose such as preservation of food. Do not use any combustible equipment in front of the airfl ow outlet to avoid fi re. Do not expose yourself directly to cold air for a long period. Do not sit or step on the unit, you may fall down accidentally. Do not touch the sharp aluminium fi n, sharp parts may cause injury. Do not switch ON the indoor unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit. Do not install the unit in oily and smoky areas. Ensure drainage pipe is connected properly. Otherwise, leakage may occur. Aerate the room regularly. After long period of use, make sure the installation rack is not deteriorate to prevent the unit from falling down. REMOTE CONTROL Do not use rechargeable (Ni-Cd) batteries.It may damage the remote control. Remove the batteries if the unit is not going to be used for a long period of time. New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control. WARNINGWARNING POWER SUPPLY Do not use modifi ed cord, joint cord, extension cord or unspecifi ed cord to prevent overheating and fi re. Do not share the same power outlet with other equipment to prevent overheating and fi re. Do not operate with wet hands to prevent electric shock. If the supply cord is damage, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard. It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fi re. This equipment must be earthed to prevent electrical shock or fi re. In case of emergency or abnormal conditions (burnt smell, etc), turn off the power supply, and please consult authorized dealer. Prevent electric shock by switching off the power supply when: - Before cleaning or servicing. - Extended non-use. - Abnormally strong lightning activity. Air InletAir Inlet Air OutletAir Outlet Air OutletAir Outlet Air InletAir Inlet Air InletAir Inlet Indoor Unit Power Supply Remote Control Outdoor Unit

4 MULTI AIR CONDITIONER SYSTEM Multi Split Outdoor Unit (CU-2S18JBU) DEFINITION Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit. POWER SUPPLYPOWER SUPPLY Models Number Time Delay Fuse Rated Volts Single Split SystemCS-S9JKUW / CU-S9JKU 15 Amps 208/230V CS-S12JKUW / CS-S9JKU 15 Amps CS-S18JKU / CU-S18JKU 20 Amps CS-S22JKU / CU-S22JKU 25 Amps Multi Split SystemCS-S9JKUW, CS-S9JKUW / CU-2S18JBU 25 Amps 208/230V CS-S9JKUW, CS-S12JKUW / CU-2S18JBU CS-S12JKUW, CS-S12JKUW / CU-2S18JBU Living roomLiving room Multi Split Outdoor UnitMulti Split Outdoor Unit INDOOR UNITINDOOR UNIT • It is possible to operate the indoor units individually or simultaneously. The operation mode priority is given to the fi rst unit that turned on. • During operation, heating and cooling mode could not be activated at the same time for different indoor unit. The power indicator blinks to indicate the indoor unit is standing by for different operation mode. BedroomBedroom

ENGLISH 5 CAUTION• Switch off the power supply before cleaning. • Do not touch the aluminium fi n, sharp parts may cause injur y. 1 INDOOR UNIT • Wipe the unit gently with a soft, dry cloth. 2 FRONT PANEL Remove Front Panel • Raise and pull to remove the front panel. • Wash gently and dry. Close Front Panel • Press down both ends of the front panel to close it securely. 3 REMOTE CONTROL RECEIVER 4 ALUMINIUM FIN 5 HORIZONTAL AIRFLOW DIRECTION LOUVER S9JKUW, S12JKUW • Manually adjustable. S18JKU, S22JKU • Do not adjust by hand. 6 VERTICAL AIRFLOW DIRECTION LOUVER • Do not adjust by hand. 7 AUTO OFF/ON BUTTON • Use when remote control is misplaced or a malfunction occurs. Action Mode Press once. Auto Press and hold until 1 beep is heard, then release.Cooling Press the button to turn off. 8 AIR PURIFYING FILTER Vacuum the air purifying fi lter. • It is recommended to clean the fi lter every 6 months. • Replace the fi lter every 3 years or replace any damaged fi lter. Part no.: CZ-SA20P 9 AIR FILTERS • Air fi lter cleaning is required every two weeks. • Wash/rinse the fi lters gently with water to avoid damage to the fi lter surface. • Dry the fi lters thoroughly under the shade, away from fi re or direct sunlight. • Replace any damaged fi lters. INDOOR UNIT CLEANING INSTRUCTIONSCLEANING INSTRUCTIONSHINTHINT • Do not use benzene, thinner or scouring powder. • Use only soap ( pH7) or neutral household detergent. • Do not use water hotter than 104˚F.• To ensure optimal performance of the unit, cleaning maintenance has to be carried out at regular intervals. Dirty unit may cause malfunction and you may see error code “H99”. Please consult authorized dealer. 2 5 6 7 14 3 98

6 REMOTE CONTROL 4 TO SELECT FAN SPEED (5 OPTIONS) FAN SPEED • For AUTO, the indoor fan speed is automatically adjusted according to the operation mode. 5TO ADJUST VERTICAL AIRFLOW DIRECTION (5 OPTIONS) AIR SWING • Keeps the room ventilated. • In COOL/DRY mode, if AUTO is set, the louver swing up/down automatically. 6 TO ADJUST AIRFLOW DIRECTION (5 OPTIONS) (PAGE 7) AIR SWING • Keeps the room ventilated. • In COOL/DRY mode, if AUTO is set, the louver swing left/right and up/down automatically. Maximum distances: 33ft INDICATOR POWER(Green) TIMER(Orange) QUIET(Orange) POWERFUL(Orange) AUTO COOL DRYFAN SPEED AIR SWING FAN SPEED AIR SWI NG MOD E QUIET TEMP OFF/ON POW ERFUL TIM ER SET CANCEL ON OFF1 23 SET CHECKCLOC KRESET ACRC 3 7 4 52 8 9 10 13 11 Remote Control display 1 12 S9JKUW, S12JKUW Press the remote control’s button 1 TO TURN ON OR OFF THE UNIT • Please be aware of the OFF indication on the remote control display to prevent the unit from starting/stopping improperly. 2 TO SET TEMPERATURE • Selection range: 60°F ~ 86°F. • Operating the unit within the recommended temperature could induce energy saving. COOL mode : 78˚F ~ 82˚F. DRY mode : 2˚F ~ 4˚F lower than room temperature. 3 TO SELECT OPERATION MODE AUTO mode - For your convenience • During operation mode selection the power indicator blinks. • Unit selects operation mode every 30 minutes according to temperature setting, outdoor and room temperature (For Single Split System). • Unit selects operation mode every 3 hours according to temperature setting, outdoor and room temperature (For Multi Split System). COOL mode - To enjoy cool air • Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode. DRY mode - To dehumidify the environment • Unit operates at low fan speed to give a gentle cooling operation.

ENGLISH 7 S18JKU, S22JKU 7 TO ENJOY QUIET OPERATION • This operation reduces airfl ow noise. 8TO REACH TEMPERATURE QUICKLY • Single Split System: This operation stops automatically after 20 minutes. • Multi Split System: Press the button again or turn OFF the unit to stop this operation. 9Press and hold for 5 seconds to dim or restore the unit’s indicator brightness. 10Press and hold for approximately 10 seconds to show temperature setting in °C or °F. 11Press and hold for approximately 5 seconds to show 12-hour (am/pm) or 24-hour time indication. 12 Press to restore the remote control’s default setting. 13 Not used in normal operations. NOTESNOTES QUIET , POWERFUL • Can be activated in all modes and can be cancelled by pressing the respective button again. QUIET , POWERFUL • Cannot be selected at the same time. TO SET THE TIMERTO SET THE TIMER • To turn ON or OFF the unit at a preset time. ON OFF1 2SET Select ON or OFF timerSet the time Confi rm • To cancel ON or OFF timer, press ON or OFF then press CANCEL. • When ON Timer is set, the unit may start earlier (up to 15 minutes) before the actual set time in order to achieve the desired temperature on time. • Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control Preparation at back cover. • If timer is cancelled manually or due to power failure, you can restore the previous setting (once power is resumed) by pressing SET. FAN SPEEDMODE QUIET TEMP OFF/ON AIR SWI NG POWERFULTIM ER SET CANCEL ON OFF1 23 SET CHECKCLOC KRESE AC RC 6

8 TROUBLESHOOTING The following symptoms do not indicate malfunction.The following symptoms do not indicate malfunction. SYMPTOMSYMPTOMCAUSECAUSE Mist emerges from indoor unit.►• Condensation effect due to cooling process. Water fl owing sound during operation.►• Refrigerant fl ow inside the unit. The room has a peculiar odour.►• This may be due to damp smell emitted by the wall, carpet, furniture or clothing. Indoor fan stops occasionally during automatic fan speed setting.►• This helps to remove the surrounding odours. Operation is delayed a few minutes after restart.►• The delay is a protection to the unit’s compressor. Outdoor unit emits water/steam.►• Condensation or evaporation occurs on pipes. Timer indicator is always on.►• The timer setting repeats daily once set. Power indicator blinks before the unit is switched on.►• This is a preliminary step in preparation for the operation when the ON timer has been set. Cracking sound during operation. ►• Changes of temperature cause the expansion/contraction of the unit. Check the following before calling for servicing.Check the following before calling for ser vicing. SYMPTOMSYMPTOMCHECKCHECK Cooling operation is not working effi ciently.►• Set the temperature correctly. • Close all doors and windows. • Clean or replace the fi lters. • Clear any obstruction at the air inlet and air outlet vents. Noisy during operation.►• Check if the unit has been installed at an incline. • Close the front panel properly. Remote control does not work. (Display is dim or transmission signal is weak.)►• Insert the batteries correctly. • Replace weak batteries. The unit does not work.►• Check if the circuit breaker is tripped. • Check if timers have been set. The unit does not receive the signal from the remote control.►• Make sure the receiver not obstructed. • Certain fl uorescent lights may interfere with signal transmitter. Please consult authorized dealer. The unit stops and the timer indicator blinks. Use remote control to retrieve error code. TIMER SET CANCEL ON OFF1 23 SET CHECK CLOCK RESETAC RC 1Press for 5 seconds. 3Press for 5 seconds to quit checking. 2Press until you hear beep sound, then write down the error code.Note: • For certain errors, you may restart the unit for limited operation with 4 beeps during operation starts. 4 Turn the unit off and reveal the error code to authorized dealer.

ENGLISH 9 Information for Users on Collection and Disposal of Old Equipment and used Batteries [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.Note for the battery symbol (bottom two symbol examples): This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved. Pb FOR SEASONAL INSPECTION AFTER EXTENDED NON-USE • Checking of remote control batteries. • No obstruction at air inlet and air outlet vents. • After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents: Cooling: ≥ 14°F FOR EXTENDED NON-USE • Turn off the power supply. • Remove the remote control batteries.SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY then please consult authorized dealer under the following conditions: • Abnormal noise during operation. • Water/foreign particles have entered the remote control. • Water leaks from Indoor unit. • Circuit breaker switches off frequently. • Power cord becomes unnaturally warm. • Switches or buttons are not functioning properly. INFORMATION

10 Muchas gracias por elegir una unidad de aire acondicionado Panasonic CONTENIDOCONTENIDO PRECAUCIONES DE SEGURIDAD 10~11 SISTEMA DE AIRE ACONDICIONADO MÚLTIPLE 12 UNIDAD INTERIOR 13 MANDO A DISTANCIA 14~15 LOCALIZACIÓN DE AVERÍAS 16 INFORMACIÓN 17 GUÍA RÁPIDA CUBIERTA TRASERA NOTANOTA Las ilustraciones de este manual sirven únicamente para describir las explicaciones y pueden no coincidir exactamente con las del aparato suministrado. Están sujetas a cambios sin previo aviso con el fi n de mejorar el producto. CONDICIONES DE CONDICIONES DE FUNCIONAMIENTOFUNCIONAMIENTO Utilice este aparato de aire acondicionado dentro del siguiente intervalo de temperaturas Temperatura (˚F)Interior *DBT *WBT ENFRIAMIENTOMáx. 89.6 73.4 Mín. 60.8 51.8 Temperatura (˚F)Exterior *DBT *WBT ENFRIAMIENTOMáx. 109.4 78.8 Mín. 60.8 51.8 * DBT: Temperatura de bulbo seco * WBT: Temperatura de bulbo húmedo PRECAUCIONES DE SEGURIDAD Para evitar lesiones personales, lesiones a terceros, o daños materiales, cumpla lo siguiente. El uso incorrecto por no seguir las instrucciones puede causar daños o averías; su gravedad se clasifi ca con las indicaciones siguientes: ADVERTENCIAADVERTENCIAEsta indicación advierte del posible peligro de muerte o de daños graves. PRECAUCIÓNPRECAUCIÓN Esta indicación advierte de los posibles daños o desperfectos materiales. Las instrucciones que deben seguirse están clasifi cadas mediante los siguientes símbolos: Este símbolo denota una acciónque está PROHIBIDA. Estos símbolos denotan acciones que son OBLIGATORIAS. ADVERTENCIAADVERTENCIA UNIDAD INTERIOR Y UNIDAD EXTERIORUNIDAD INTERIOR Y UNIDAD EXTERIOR Este aparato no debe ser utilizado por personas (incluyendo niños) con discapacidades mentales, sensoriales o físicas, o falta de experiencia y conocimiento, a menos que hayan recibido formación o supervisión en relación al uso del aparato por una persona responsable por su seguridad. Los niños deberían estar supervisados para asegurar que no juegan con el aparato. Consulte a un distribuidor autorizado o especialista para reparar, instalar, retirar y reinstalar la unidad. Una instalación y uso incorrectos provocarán fugas, descargas eléctricas o incendios. No instale la unidad en ambientes potencialmente explosivos o infl amables. En caso contrario, podría provocar accidentes de incendios. No introduzca los dedos u otros objetos en la unidad exterior o interior del aire acondicionado, ya que las partes rotatorias podrían provocarle lesiones. No toque la unidad exterior durante un relámpago, ya que podría causar una descarga eléctrica. MANDO A DISTANCIA No permita que bebés y niños pequeños jueguen con el mando a distancia para evitar que ingieran accidentalmente las pilas.