Page 11
Outdoor UnitCU-4KE24NBU Indoor Unit Duct Less Type RatedCS-MKE7NKU × 2 + CS-MKE9NKU Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE7NKU 2units / CS-MKE9NKU 1units Outdoor Unit : CU-4KE24NBU 1unit The combination indoor unit is AHRI 210/240. 2. Rating conditions are:...
Page 12
Outdoor UnitCU-4KE24NBU Indoor UnitCS-MKE9NKU × 3 Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE9NKU 3units Outdoor Unit : CU-4KE24NBU 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80 °F DB / 67 °F WB Heating : Indoor air temp. 70 °F DB Outdoor...
Page 13
Outdoor UnitCU-4KE24NBU Indoor UnitCS-MKE9NKU × 3 Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE9NKU 3units Outdoor Unit : CU-4KE24NBU 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80 °F DB / 67 °F WB Heating : Indoor air temp. 70 °F DB Outdoor...
Page 14
Outdoor UnitCU-4KE31NBU Indoor UnitCS-MKE7NKU × 3 + CS-MKE9NKU Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE7NKU 3units / CS-MKE9NKU 1units Outdoor Unit : CU-4KE31NBU 1unit The combination indoor unit is AHRI 210/240. 2. Rating conditions are: Cooling : Indoor air...
Page 15
Outdoor UnitCU-4KE31NBU Indoor UnitCS-MKE9NKU × 4 Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE9NKU 4units Outdoor Unit : CU-4KE31NBU 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80 °F DB / 67 °F WB Heating : Indoor air temp. 70 °F DB Outdoor...
Page 16
Outdoor UnitCU-4KE31NBU Indoor UnitCS-MKE9NKU × 4 Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKE9NKU 4units Outdoor Unit : CU-4KE31NBU 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80 °F DB / 67 °F WB Heating : Indoor air temp. 70 °F DB Outdoor...
Page 17
Outdoor UnitCU-3KE19NBU 2-2-1. Outdoor Unit Control PCB Control Circuit Fuse ControlsPart No. Microprocessor 250V 25A CB-CU-3KE19NBU DATA SUBJECT TO CHANGE WITHOUT NOTICE. Pints (cc) - Micro F VAC External FinishAcrylic baked-on enamel finishFV50S ... 1.91 (900) - - Internal Controller Yes Yes Aluminum Plate Fin / Copper Tube 2 18.1 Face Area ft 2 (m2)6.40 (0.595) Coil Rows Fins per inch Heat Exchanger Coil SIC-71FW-D490-1 ... 1 Compressor Oil ... Amount 8 90 750 / 750 OhmDC Motor...
Page 18
Outdoor UnitCU-4KE24NBU Control PCB Control Circuit Fuse ControlsPart No. Microprocessor 250V 25A CB-CU-4KE24NBU DATA SUBJECT TO CHANGE WITHOUT NOTICE. Pints (cc) - Micro F VAC External FinishAcrylic baked-on enamel finishFV50S ... 1.91 (900) - - Internal Controller Yes Yes Aluminum Plate Fin / Copper Tube 2 18.1 Face Area ft 2 (m2)6.40 (0.595) Coil Rows Fins per inch Heat Exchanger Coil SIC-71FW-D490-1 ... 1 Compressor Oil ... Amount 8 90 750 / 750 OhmDC Motor Type Compressor Model /...
Page 19
Outdoor UnitCU-4KE31NBU Control PCB Control Circuit Fuse ControlsPart No. Microprocessor 250V 25A CB-CU-4KE31NBU DATA SUBJECT TO CHANGE WITHOUT NOTICE. Pints (cc) - Micro F VAC External FinishAcrylic baked-on enamel finishFV50S ... 2.55 (1,200) - - Internal Controller Yes Yes Aluminum Plate Fin / Copper Tube 2 18.1 Face Area ft 2 (m2)7.75 (0.72) Coil Rows Fins per inch Heat Exchanger Coil SIC-71FW-D490-1 ... 1 Compressor Oil ... Amount 8 90 800 / 800 OhmDC Motor Type Compressor Model...
Page 20
Temperature F ( C) 40 35 30 25 20 15 10 5 0 ( -20)(-15)(-10) (-5) (0) (5) (10) (15) (20)-4 5 14 23 32 41 50 59 68 Resistance (k ohm) 0 32 50 68 86 104 122 140 158 176 194 40 60 80 100 120 140 160 180 200 20 Resistance (k ohm) (0) (10) (20) (30) (40) (50) (60) (70) (80) (90) Temperature F ( C) 2-3. Other Component Specifications CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU Sensor Name Compressor temp sensor TKS293BModel No. of sensor 11Quantity of Sensor 1 Outdoor air temp sensor Outdoor heat exchanger...