Home > Panasonic > Air Conditioner > Panasonic Csc18dku Operating Instructions Manual

Panasonic Csc18dku Operating Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Csc18dku Operating Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
    F564699
    Operating Instructions
    Air Conditioner
    CS-C18DKU  CU-C18DKU
    CS-C24DKU  CU-
    C24DKU
    Please register your product at : www.panasonic.com/registerFor assistance, please call : (866)-292-7292, for Hawaii residents call (808)-488-7779.
    Manufactured by:
    Panasonic HA Air-Conditioning (M) Sdn. Bhd.Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site, 40300 Shah Alam, Selangor, Malaysia.
    ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. 2 ~ 7
    ESPA
    ÑOL Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento  
      de consulta. 8 ~ 13  
    						
    							
    2
    
    Safety Regulation
    Use this air conditioner under the following temperature range.
    DBT: Dry Bulb Temperature
    WBT: Wet Bulb TemperatureIndoorOutdoor
    DBTWBTDBTWBT
    Maximum Temperature89.673.4109.478.8
    Minimum Temperature
    60.851.860.851.8
    Operation Condition (°F)
    The appliance is not intended for use by young children or infirm 
    people without supervision. Young children should be supervised to 
    ensure that they do not play with the appliance.
    Power Supply
    Time Delay Fuse  Rated Volts 
    15 Amps
    CS-C18DKU/CU-C18DKU208/230V
    25 Amps
    CS-C24DKU/CU-C24DKU
    To prevent personal injury, injury 
    to others and property damage, the following instructions must be followed.
    Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is 
    classified as below:
    ■ Important notice
    This symbol denotes an action that is PROHIBITED.
    These symbols denote actions that are 
    COMPULSORY.
    This sign warns of death or  serious injury.
    Warning
    This sign warns of injury or damage to property.
    Caution
    The instructions to be followed 
    are classified by the following 
    symbols:
    Thank you for purchasing a Panasonic Air Conditioner
    SAFETY PRECAUTIONS
    Installation Pr ecautions
    •  Use specified supply cord.
    • If the supply cord is damaged or needs replacement, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
    • Remove the batteries if the unit is not going to be used for a long period of time.
    • New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.
    • In case of emergency or if an abnormal condition (burnt smell, etc) occurs, turn 
    off the power supply.
    •  Do not share power outlet.
    •  Do not modi
    fy power cord.
    •  Do not use an extension co
    rd.
    •  Do not operate with wet hands.
    •   Do not insert fingers or other objects into 
    the indoor or outdoor unit.
    •  Do not attempt to repair the unit by 
    yourself.
    • Do not use rechargeable (Ni-Cd) batteries.
    • Keep the remote control away from infants and small children to prevent them from accidentally swallowing the batteries.
    •  Do not wash the unit with water, benzene,  thinner or scouring powder.
    •   Do not use for other purposes such as 
    preservation of food.
    •  Do not store or use any combustible  equipment in the airflow direction.
    •  Do not sit on or place anything on the 
    indoor or outdoor unit.
    • Do not expose directly to cold air for a long period. •  Ventilate the room regularly.
    •  Pay attention as to whether the 
    installation rack is damaged after a long period of usage.
    •  Switch off the power supply before 
    cleaning or servicing.
    • T urn off the power supply if the unit is not going to be used for a long period of time.
    Oper ation Pr ecautions
    Do not install, remove or reinstall the unit by yourself.
    •  Improper install ation will cause leakage, electric shock or fire. Please consult an authorized dealer or specialist for the installation work.
    •  This air conditioner must be grounded.
     Improper grounding will cause electric shock.
    •  Ensure that the drainage piping is connected properly.
     Otherwise, water will leak.
    • Current leakage protection equipment must be installed. Otherwise, electric shock or fire may 
    occur.
    •  Do not install the unit in a 
    potentially explosive environment.
    Warning
    Caution
    Warning
    Caution          
    						
    							
    ENGLISH
    
    3
    
    �������������������������
    �����
    
    TEMP
    MODEPOWERFULAIR SWINGFAN SPEED
    QUIET
    123
    TIMER
    ON
    OFFCANCELSET
    COOLAUTO
    AU
    TO
    AU
    TOFAN
    RESET CLOCK
    OFF/ON
    
    • Timer operation will be based on current time set.
    • The batteries can be used for 
    approximately 1 year.
    • The batteries must be recycled or 
    disposed of properly.
    Note:  The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subject to change without notice for future improvement.
    PRODUCT OVERVIEW
    Air intake
    Airflow direction 
    louver
    Air filter
    Front panel
    Indoor Unit
    Outdoor Unit
    Air inlet (rear)
    Air outlet
    LCD display
    Temperature setting
    Powerful operation
    Memory resetClock setting
    Economy operationOperation mode
    Quiet operation
    Airflow direction 
    adjustment Timer settingOff/OnFan speed selection
    Remote Contr ol
    Indicator
    Air  
    Purifying  
     
    filter
    Auto OFF/ON 
    button
    Receiver
    Transmitter
    Air inlet (side)
    Discharged 
    air
    •  Make sure it is not obstructed.
    •  Maximum distances : 10m.
    • Certain fluorescent lights may interfere with signal transmission. Consult your dealer.
    Remote Control Preparation
    ■ About
    Remote Control Signal
    Auto OFF/ON Button
    1. Pull out 2. Insert ba
    tteries 
    (AAA or R03)
    3. Press CLOCK button
    4. Set 
    current time
    5. Press again to confirm
    Troubleshooting
    ● Operation delayed for a few minutes after restart.➤ This is a normal self protection function.
    ●  Sound like water flowing during operation.➤ Caused by refrigerant flow inside.
    ● Mist emerges from indoor unit.➤ Condensation effect due to cooling process.
    ● Noisy during operations.➤  Installation work could be slanted or front panel isn’t closed properly .
    ● Remote control/display does not work.➤ Check whether batteries are correctly inserted or need replacement.
    ● The unit cannot operate.➤ Check whether circuit breaker is tripped or timer is being used correctly .
    ● Outdoor unit emits water/steam.➤ Condensation or evaporation has occurred at piping surface.
    • To operate the unit if the remote  control is misplaced or malfunctioning.
    ActionOperation mode
    Press onceAutomatic Operation
    Press until “beep”  sound
    Cooling Operation
    • To turn OFF, press the Auto OFF/ON button again.
    • To switch the remote control signal 
    receiving sound off or on.
     1. Press until you hear a “beep” sound and release.
     2. Press again until you hear a “beep-beep” sound and release.
     3. Press to switch the sound off or on. 
       (Long “beep” - OFF; short “beep” - ON)           
    TEMP
    MODEPOWERFULAIR SWING
    FAN SPEED
    ECONOM<
    123
    TIMER
    ON
    OFF
    CANCELSET
    COOLAUTO
    AU
    TO
    AU
    TOFAN
    RESET CLOCK
    OFF/ONQUIET                          
    						
    							
    4
    
    TEMP
    POWERFUL
    AIR SWINGFAN SPEED
    ECONOMY
    123
    TIMER
    ON
    OFF
    CANCEL
    SET
    COOLAUTO
    AU
    TO
    AU
    TOFAN
    RESET CLOCK
    QUIET
    OFF/ON
    
    MODE
    
    Troubleshooting
    HOW TO OPERATE
    ●  The room has a peculiar odour.➤ This may be a damp smell emitted by the wall, carpet, furniture or clothing in the room.
    ● Air conditioner does not cool efficiently.➤  Ensure the temperature has been set correctly.➤ Ensure windows and doors have been closed properly.➤ Ensure filters are cleaned or replaced when necessary.➤ Ensure inlet and outlet vents of the unit have not been obstructed.
    ● To save electricity, close the curtains when using air conditioner to prevent sunlight and heat from coming in.
    Hint
    ■ Operation Details
    • The unit will automatically select the operation mode according to the room temperature.
    • Once the operation mode is selected, the unit will operate at the standard setting temperature as shown:
    Room
    temperature
    Operation
    mode
    Standard setting temperature
    73.4°F & aboveCool77°F
    Below 73.4°FDry72°F
    •  You may press  or  button to change the standard setting temperature to “HI” or “LO” as shown:
    Operation modeHILO
    Cool81°F73°F
    Dry75°F68°F
    • Enables you to enjoy the cooling effect at your preferred setting temperature.
    • The range of temperature can be selected from 60°F ~ 86°F.
    • Allows you to set the desired temperature at low fan speed which  enables you to dehumidify your surroundings.
    • The range of temperature can be selected from 60°F ~ 86°F.
    AUTO - Automatic Operation
    COOL - Cooling Operation
    DRY - Soft Dr y Operation
    2
    Select the 
    desired 
    operation.
    3
    Set the 
    temperature.
    Start the 
    operation.
    1
    ● Powerful, Quiet and Economy operations can be activated in 
    all operation modes.
    ● Press OFF/ONbutton again to stop the operation.
    Auto, Cool, Dr y                                 
    						
    							
    5
    ENGLISH
    
    TEMP
    MODE
    AIR SWING
    123
    TIMER
    ON
    OFF
    CANCEL
    SET
    COOLAUTO
    AU
    TO
    AU
    TOFAN
    RESET CLOCK
    OFF/ON
    
    ����
    ���
    
    AUTO
    
    ECONOMY
    POWERFUL
    
    F AN SPEED
    
    QUIET
    
    AUTO
    
    Powerful, Quiet, Economy, Fan Speed, 
    Air Swing
    Hints
    HOW TO OPERATE
    ●  If you wish to have the cool air blowing directly on you, set the airflow direction downward but not for an excessive length of time, as it may harm your health.
    ●  Electricity use can be reduced by approximately 10% if you set the temperature 1°F higher than the desired temperature during cooling operation.
    Troubleshooting
    ● Indoor fan stops occasionally  during Automatic Fan Speed setting.➤ This is an advanced feature that helps to remove smell from the surrounding area during operation.
    Enables 
    powerful 
    operation.
    Enables 
    quiet 
    operation.
    QUIET
    POWERFUL
    Select fan speed.
    FAN SPEED
    Adjust the 
    vertical or 
    horizontal airflow 
    direction louver.
    AIR SWING
    Enables 
    economy 
    operation.
    ECONOMY
    ● Powerful, Quiet or Economy operations cannot be activated 
    at the same time.
    ● Powerful, Quiet or Economy operations can be cancelled by 
    pressing the respective button again.
    ■ Operation Details
    • To save ele ctrical power consumption.
    • Use when desired room temperature is reached.
    •  To achieve setting temperature quickly. It will operate for 15 minutes and return to the previous setting.
    ECONOMY
    POWERFUL
    • To provide you with various fan speed selections.
    • There are 3 levels of fan speed in addition to automatic fan speed.
    • Automatic fan speed:
      The speed of the indoor fan is 
    automatically adjusted according to the operation.
    FAN SPEED
    •  To provide a quiet environment.
    QUIET
    AIR SWING
    • To ventilate air in the room.
    • There are 5 settings in addition to 
    automatic vertical airflow direction.
    •  If automatic vertical airflow direction has 
    been set, the louver swings up and down 
    automatically.
    •  To ventilate air in the room.
    • There are 5 settings in addition to 
    automatic horizontal airflow direction.
    •  If automatic 
    horizontal  airflow direction has been set, the louver swings left and 
    right automatically.
    • Please do not adjust the vertical and horizontal  airflow direction louver 
    manually.                                       
    						
    							
    6
    
    TEMP
    POWERFUL
    AIR SWINGFAN SPEED
    123
    TIMER
    COOLAUTO
    AU
    TO
    AU
    TOFAN
    RESET CLOCK
    OFF/ON
    MODE
    ECONOMY
    QUIET
    
    ON
    OFF
    
    CANCEL
    SET
    
    HOW TO OPERATE
    Timer
    ●  Press CLOCK button for more than 10 seconds to change the time format - from  AM/PM format to 24 hour format.
    ● For your convenience, you can set the air conditioner to operate automatically by using both ON and OFF timer.
    Hints
    Troubleshooting
    ● TIMER indicator always on.➤ Timer is activated and the setting will repeat itself daily.
    ● POWER indicator is blinking 15 minutes before ON timer is activated.➤ The unit is determining the operation mode by sensing the room temperature. This happens when it has  been set to AUTO operation mode.
    ■ Operation Details
    • Use the ON timer to turn on the air 
    conditioner at the desired time. This 
    will give you a cooled environment, e.g. when you return from work or wake up.
    • When the ON timer is set, operation will start 15 minutes before the actual set time.
    • Use the OFF timer to stop air conditioner 
    operation at the desired time. This can 
    save electricity while you are going out or sleeping.
    • The set timer will repeat daily once it is set.
    • If there is a power failure, you can press 
    the SET button to restore the previous setting once the power resumes.
    • If the timer is cancelled, you can restore 
    the previous setting by pressing SET 
    button.
    TIMER
    1
    Select ON or 
    OFF timer.
    2
    Set the 
    desired time.
    3
    Confirm the 
    setting.
    CANCEL
    Cancel the 
    selected timer.
    ● Ensure the clock on the remote control has been set 
    correctly.
    ●  You can set both the ON and OFF timers at the same time.
    ● To cancel either the ON or OFF timer, press ON or OFF, 
    then press CANCEL.                                  
    						
    							
    7
    ENGLISH
    
    CARE & CLEANING
    Switch of f  the power suppl y 
    befor e cleaning
    Vacuum, wash and dry.
    AIR FILTER
    INDOOR 
    UNIT
    Wipe gently.
    Remove
    Remove
    Raise and pull to remove. 
    Wash and dry.
    FRONT PANEL
    AIR PURIFYING FILTER
    Vacuum the Air 
    Purifying filter.
    • Wipe the unit gently with a soft, dry cloth.
    • It is recommended that you clean the air 
    filter once every 2 weeks.
    •  Purchase the replacement filter if it is damaged. Part no.: CWD001160 (Left)   CWD001161 (Right)
    INDOOR UNIT
    AIR FILTER
    • It is recommended to clean the filter every 6 months.
    • Replace the filter every 3 years or purchase the replacement filter if it is damaged.  Part no.: CZ-SA20P
    AIR PURIFYING FILTER
    •  This inspection is recommended before operating the air conditioner in every season.
    •  Check if the remote control batteries 
    need to be replaced.
    • Ensure there is no obstruction at all air intake and outlet vents.
    • After the unit has been operating for 15  minutes, it is normal if the temperature 
    difference between air intake and outlet 
    vents at indoor unit is:
    Operation Temperature
    Cooling 14°F
    ■ Washing Instructions
    • Do not use benzene, thinner or scouring powder.
    • Use soaps or neutral household detergent ( pH7) only.
    • Do not use water warmer than 104°F.
    ■ Pre-season Inspection
    ●  Clean the filter regularly as dirty filters will cause unpurified air, low cooling  capacity, unpleasant smells and higher energy consumption.
    ●  The unit will become dirty and the performance of the unit will decrease after being used for several seasons. Please consult an authorized dealer to perform seasonal inspections in addition to regular cleaning.
    ●  This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from being damaged by abnorm ally strong lightning activity, you may switch off the power supply.
    Hints                               
    						
    							
    8
    
    Normas de seguridad
    Este dispositivo no debe ser utilizado por niños ni personas discapacitadas sin supervisión. Se debe vigilar que los niños no jueguen con este aparato.
    Suministro De Poder
    Fusible de retardo Voltaje asignado
    15 Amps
    CS-C18DKU/CU-C18DKU208/230V
    25 Amps
    CS-C24DKU/CU-C24DKU
    Muchas gracias por elegir la climatizador de aire Panasonic
    MEDIDAS DE SEGURIDAD
    Cuidado
    Pr ecauciones al instalar
    •  Utilice el cable de alimentación 
    especificado.
    • Si el cable de alimentación está dañado o es necesario cambiarlo, el cambio debe hacerlo el fabricante o su servicio técnico asociado o una persona de 
    cualificación equivalente para evitar 
    riesgos.
    • Retire las pilas si no piensa utilizar la unidad durante un largo tiempo.
    • Nuevas baterías del mismo tipo tienen que ser insertas de acuerdo con la polaridad mencionada para que el control remoto funcione bien.
    • En caso de emergencia o de funcionamiento extraño (olor a quemado, etc.), desconecte la fuente de alimentación.
    •  No conecte otros aparatos a la misma 
    salida de corriente.
    • 
    No modifique el cable eléctrico.
    • No utilice un cable de extensión.
    •  No opere la unidad con las manos 
    mojadas.
    •   No inserte los dedos ni ningún tipo de 
    objetos en las unidades interna o externa.
    • No repare la unidad usted mismo.
    • No use pilas recargables (Ni-Cd).
    • No deje el control remoto a mano de niños y bebes para que no absorben las baterías.
    •  No lave la unidad con agua, benceno, 
    disolvente o limpiador en polvo.
    •   No utilice el aparato para otros fines como 
    la conservación de alimentos.
    •  No utilice ningún equipo combustible en la  dirección del flujo de aire.
    •  No se siente o coloque objetos sobre la  unidad interior o exterior.
    • No se exponga directamente al aire frío por mucho tiempo. •  Ventile la habitación regularmente.
    • Compruebe si el bastidor de instalación está dañado después de haber usado el aparato durante un largo período.
    • Desconecte la alimentación antes de proceder a la limpieza o al mantenimiento.
    • Desconecte la alimentación si no va a utilizar la unidad durante un periodo largo de tiempo.
    Pr ecauciones al Oper ar
    No instale ni desinstale ni reinstale la unidad usted mismo.
    • Una instalación incorrecta puede causar fugas de agua, descargas eléctricas o incendios. Por favor consulte al distribuidor autorizado o a un especialista para el trabajo de instalación.
    • Este climatizador de aire debe ser conectado a tierra. Causará una sacudida eléctrica si el contacto a tierra no es perfecto.
    • Compruebe que las tuberías de drenaje están conectadas adecuadamente. Si no, habrá pérdidas de agua.
    • Debe instalar un equipo de protección contra fugas de agua. Si no, puede producirse una sacudida eléctrica o un incendio.
    • No instale la unidad en una atmósfera potencialmente explosiva.
    Advertencia
    Cuidado
    Advertencia
    Utilice este climatizador de aire dentro del siguiente intervalo de temperaturas.
    DBT: Temperatura de bulbo seco
    WBT: Temperatura de bulbo húmedoInteriorExterior
    DBTWBTDBTWBT
    Temperatura máxima89,673,4109,478,8
    Temperatura mínima
    60,851,860,851,8
    Condiciones de funcionamiento (°F)
    Para prevenir heridas personales, heridas a otras personas y daños de la propiedad, se deben seguir las siguientes instrucciones.
    El uso incorrecto por no seguir las instrucciones puede causar daños o averías; su gravedad 
    se clasifica con las indicaciones 
    siguientes:
    ■ Definición
    Cuidado
    Las instrucciones a seguir 
    están clasificadas mediante los 
    símbolos siguientes:
    Esta indicación muestra la posibilidad de causar muerte o daños serios.
    Este símbolo denota una acción que está  PROHIBIDA.
    Estos símbolos denotan una acción que es 
    OBLIGATORIA de hacer.
    Advertencia
    Esta indicación advierte sobre la posibilidad de daños a la propiedad.          
    						
    							
    ESPA
    ÑOL
    
    9
    
    Mando a distancia
    �������������������������
    �����
    TEMP
    MODEPOWERFULAIR SWINGFAN SPEED
    QUIET
    123
    TIMER
    ON
    OFFCANCELSET
    COOLAUTO
    AU
    TO
    AU
    TOFAN
    RESET CLOCK
    OFF/ON
    5. Presione para confirmar
    Nota:  Las ilustraciones de este manual se incluyen únicamente con fines explicativos y pueden ser diferentes de la unidad real. Están sujetas a cambios sin previo aviso para futuras mejoras.
    DESCRIPCIÓN FUNCIONAL DEL PRODUCTO
    Entrada de aire
    Persiana de 
    dirección del 
    flujo de aire
    Filtro de 
    aire
    Panel frontal
    Unidad interior
    Unidad exterior
    Entrada de aire (posterior)
    Salida de aire Indicador
    Filtro de 
    Purifica-
    dor de 
    aire
    Botón de apagado/ 
    encendido  
    automático
    Receptor
    Entrada de aire 
    (lateral)
    Corriente 
    de aire
    Pantalla LCD
    Borrado de memoria
    Modo de funcionamiento
    Funcionamiento 
    silencioso
    Ajuste de la dirección del 
    flujo de aire Botón “Off/On” 
     (Desconexión/conexión)
    Selección de la velocidad 
    del ventilador
    Ajuste del reloj
    Ajuste de temperatura
    Funcionamiento potente
    Funcionamiento en modo económico
    Ajuste del temporizadorTransmisor
    Localización de averías
    ● El funcionamiento se retarda unos minutos tras reiniciar.➤ Es un control de autoprotección normal.
    ● Se escucha un sonido como de agua corriendo durante el funcionamiento.➤ Es el paso del refrigerante en el interior de la unidad.
    ● Sale neblina de la unidad interior. ➤ Efecto de condensación producido durante el proceso de enfriamiento.
    ● Funcionamiento ruidoso.➤ La unidad puede haberse instalado inclinada o el panel frontal no se cerró bien.
    ● El mando a distancia/pantalla no funciona.➤ Compruebe si las baterias están instaladas correctamente o es necesario cambiarlas.
    ● La unidad no funciona.➤ Verifique que los interruptores están desconectados y que el temporizador se utiliza correctamente.
    ● Sale agua o vapor de la unidad exterior.➤ Se produce condensación o evaporación en la superficie de las tuberías.
    • Asegúrese de que el paso de la señal no está obstruido.
    •  Distancia máxima: 10 m.
    • Algunos tipos de lámparas fluorescentes pueden afectar a la transmisión de la señal. Consulte al distribuidor.
    Preparación del mando a distancia
    ■ Acerca de
    Señal del mando a distancia
    • Para hacer funcionar la unidad si el mando a distancia está mal colocado o no funciona correctamente.
    Acción
    Modo de 
    funcionamiento
    Presione una vez. Funcionamiento 
    autom
    ático
    Pulsar hasta que  suene el pitido. Función de 
    enfriamiento
    •  Para apagar, presione de nuevo el botón de apagado/encendido automático.
    • Para activar o desactivar el sonido de recepción de señal del mando a distancia.
     1. Pulse hasta que suene el pit ido y, después, suelte.
     2. Pulse hasta que suene el doble 
    pitido y, después, suelte.
     3. Pulse para activar o desactivar el sonido.
        (Pitido largo - OFF; pitido corto - ON
    )
    • El temporizador funcionará según la hora ajustada actual.
    • Las pilas se pueden utilizar durante aproximadamente 1 año.
    • Las pilas se deben reciclar o desechar correctamente.
    Botón de apagado/encendido automático
    1. Quite la tapa 2. Inserte las 
    pilas (AAA o R03)
    3. Presione el botón “CLOCK”
    4. Ajuste 
    la hora actual    
    TEMP
    MODEPOWE5F8LAI5 SWIN*
    FAN SPEED
    ECONOM<
    123
    TIME5
    ON
    OFF
    CANCELSET
    COOLA8TO
    A8
    TO
    AU
    TOFAN
    RESET CLOCK
    OFF/ONQUIET                                 
    						
    							
    10
    
    TEMP
    POWERFUL
    AIR SWINGFAN SPEED
    ECONOMY
    123
    TIMER
    ON
    OFF
    CANCEL
    SET
    COOLAUTO
    AU
    TO
    AU
    TOFAN
    RESET CLOCK
    QUIET
    
    ■ Detalles de  
    funcionamiento
    •  La unidad seleccionará automáticamente el modo de funcionamiento de acuerdo con la temperatura ambiente.
    •  Una vez seleccionado el modo de 
    funcionamiento, la unidad funcionará a la temperatura estándar como se indica:
    Temperatura ambienteModo de funcionamiento Temperatura estándar
    73,4°F o másEnfriamiento77°F
    Menos de 73,4°FSecado72°F
    •  Puede presionar el botón  o  para cambiar la temperatura estándar a “HI” o “LO” tal como se indica:
    Modo de funcionamientoHILO
    Enfriamiento81°F73°F
    Secado75°F68°F
    •  Permite disfrutar del efecto de enfriamiento a la temperatura deseada.
    •  Puede seleccionar una temperatura en  el intervalo de 60°F ~ 86°F.
    •  Deshumidifica el ambiente fijando la 
    temperatura deseada con una velocidad 
    lenta del ventilador.
    •  Puede seleccionar una temperatura en  el intervalo de 60°F ~ 86°F.
    AUTO - Funcionamiento automático
    COOL - Función de enfriamiento
    DRY -  Función de secado suave
    2
    3
    1
    Automático, Enfriamiento, Secado
    Seleccione el 
    funcionamiento 
    deseado.
    Ajuste la 
    temperatura.
    Inicie el 
    funcionamiento.
    CÓMO HACERLO FUNCIONAR
    ● Los funcionamientos Potente, Silencioso y de Económico 
    pueden activarse en todos los modos de funcionamiento.
    ● Presione el botón OFF/ON otra vez para detener el funcionamiento.
    OFF/ON
    MODE
    ●  Cuando utilice el climatizador de aire, cierre las cortinas para evitar que entre la luz y el calor del sol y así ahorrar electricidad.
    Sugerencia
    Localización de averías
    ●  Hay un olor extraño en la habitación.➤  Puede tratarse del olor a humedad producido por las paredes, las alfombras, los muebles o las telas de la habitación.
    ●  El climatizador de aire no enfría eficazmente.➤  Compruebe que la temperatura se ha ajustado correctamente.➤  Compruebe que las ventanas y las puertas están bien cerradas.➤  Compruebe que los filtros se han limpiado o cambiado en caso de ser necesario.➤ Asegúrese de que las tomas de entrada y salida de aire de las unidades no están obstruidas.                                 
    						
    All Panasonic manuals Comments (0)