OPERATING INSTRUCTIONS Room Air Conditioner Before using your air-conditioner, please read this operating instructions carefully and keep it for future reference. COOLING M ODEL :- Indoor Outdoor CS-C18BKP CU-C18BKP6 CS-C24BKP CU-C24BKP6 ENGLISH ...................... P. 1 – P. 11 ESPAÑOL ..................... P. 12 – P. 21 Before using your air-conditioner, please read this operating instructions carefully and keep it for future reference. F563385® For assistance, please call; 1-800-211-PANA(7262) or send e-mail to: [email protected] or refer to www.panasonic.com
1 Thank you for purchasing our Panasonic Room Air Conditioner.CONTENTS:Features ..................................................... 1 :Safety Precautions .................................... 2 Installation Precautions Operation Precautions :Name of Each Part ................................ 3~4 Indoor Unit Outdoor Unit Accessories Remote Control :Preparation Before Operation .................. 5 Indoor Unit Remote Control :How to Operate ...................................... 5~6 :Setting the Timer ....................................... 7 :Convenience Operation ............................ 7 Sleep Mode Operation Economy Mode Operation Powerful Mode Operation :Care and Maintenance .............................. 8 Cleaning the Indoor Unit and Remote Control Cleaning the Air Filter Cleaning the Front Panel Air Purifying Filters Pre-season Inspection When the Air Conditioner is Not Used for an Extended Period of Time Recommended Inspection :Helpful Information ................................... 9 :Energy Saving and Operation Hints ........ 9 :Troubleshooting ...................................... 10 Normal Operation Abnormal Operation Call the Dealer Immediately Note: Before using your air conditioner, please read this operating instructions carefully and keep it for future reference. FEATURESSelf-illuminating Button For your convenience to operate in the dark. (Refer page 4) Automatic Operation Sense indoor temperature to select the optimum mode. (Refer page 5) Sleep Mode Prevent the room from getting too hot or too cold while you are sleeping. (Refer page 7) Economy Mode To reduce electrical power consumption. (Refer page 7) Powerful Mode Reaches the desired room temperature quickly. (Refer page 7) Removable Front Panel For quick and easy cleaning. (washable) (Refer page 8) Catechin Air Purifying Filter Filter that can trap dust, tobacco smoke and tiny particles in the room. It can also prevent growth of bacteria and viruses trapped in this filter. (Refer page 8) Solar Refreshing Deodorizing Filter Used to remove unpleasant odour and deodorize the air in the room. (Refer page 8) Auto Restart Control Restart the unit automatically after power failure. (Refer page 9) Blue Coated Condenser At Outdoor Unit This is the most advanced anti-rust coating. ! Warning 1) Operate your air conditioner from a stable 208/230 volts AC supply. 2) Plug into a separate 15 amps (CS-C18BKP/CU-C18BKP6) or 20 amps (CS-C24BKP/CU-C24BKP6) grounded outlet only. 3) Use of extension cords. Avoid using extension cords. If there are no alternatives, ensure that the cord is a UL listed 3-wire grounding type, rated 250 volt with a minimum current-carrying rating of 15 amps (CS-C18BKP/CU-C18BKP6) or 20 amps (CS-C24BKP/CU-C24BKP6), number 14 (CS-C18BKP/ CU-C18BKP6), number 12 (CS-C24BKP/CU-C24BKP6) or a heavier wire. 4) Use a 15 amps (CS-C18BKP/CU-C18BKP6) or 20 amps (CS-C24BKP/CU-C24BKP6) time delay fuse or a circuit breaker. 5) Do not switch off by unplugging the power plug while it is operating. Turn off the air conditioner by using remote control, before unplugging. 6) Remove power plug or disconnect from the main before servicing this appliance. 7) Do not repair by yourself. In case of malfunction of this appliance, do not repair by yourself. Contact the sales dealer or service dealer for a repair. 8) Turn off the power (Isolation from main power supply). Pull off the power plug from the receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the equipment from the main power supply in case of an emergency. ! Caution DISCONNECT THE MAIN PLUG FROM THE SUPPLY SOCKET WHEN NOT IN USE, WHERE SUPPLY CONNECTION IS VIA MAIN PLUG. POWER SUPPLY Time Delay Fuse: Line Cord Plug: 15 Amps (CS-C18BKP/ CU-C18BKP6) 20 Amps (CS-C24BKP/ CU-C24BKP6) Rated Volts: Socket Type: 208/230 V (CS-C24BKP/ CU-C24BKP6) (CS-C18BKP/ CU-C18BKP6)
ENGLISH2 SAFETY PRECAUTIONSBefore operating, please read the following “Safety Precautions” carefully. To prevent personal injury, injury to others and property damage, the following instructions must be followed. Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as follow: ! Warning This sign warns of death or serious injury. ! Caution This sign warns of damage to property. The instructions to be followed are classified by the following symbols: This symbol (with a white background) denotes an action that is PROHIBITED. These symbols (with a black background) denote actions that are COMPULSORY. OFF Installation Precautions ! Warning This room air conditioner must be earthed. Improper grounding could cause electric shock. Ensure that the drainage piping is connected properly. Otherwise, water will leak out. Do not install the unit in a potentially explosive atmosphere. Gas leak near the unit could cause fire. Do not install, remove and reinstall the unit by yourself. Improper installation will cause leakage, electric shock or fire. Please engage an authorized dealer or specialist for the installation work. ! Caution Operation Precautions ! Warning This sign warns of death or serious injury. Do not share outlet. Do not insert plug to operate the unit. Do not pull out plug to stop the unit. Do not operate with wet hands. Do not damage or modify the power cord. Do not insert finger or other objects into the indoor or outdoor units. Do not expose directly to cold air for a long period. Plug in properly. Use specified power cord. If abnormal condition (burnt smell, etc.) occurs, switch off and unplug the power supply. ! Caution This sign warns of injury. Do not pull the cord to disconnect the plug. Do not wash the unit with water. Do not use for other purposes such as preservation. Do not use any combustible equipment at airflow direction. Do not sit or place anything on the outdoor unit. Switch off the power supply before cleaning. Ventilate the room regularly. Pay attention as to whether the installation rack is damaged after long period of usage. Switch off the power supply if the unit is not used for a long period. OFFOFF
3 Accessories Remote Control Remote Control Holder Two RO3 (AAA) dry-cell batteries or equivalent Air Purifying Filter (Catechin Air Purifying Filter) (Solar Refreshing Deodorizing Filter) NAME OF EACH PARTIndoor Unit1Front Panel 2Air Intake Vent 3Power Supply Cord 4Air Outlet Vent 5Vertical Airflow Direction Louver 6Horizontal Airflow Direction Louver 7Indicator Panel 1Auto Operation Button (when the front panel is opened) 2Economy Mode Indicator – GREEN 3Powerful Mode Indicator – ORANGE 4Power Indicator – GREEN 5Sleep Mode Indicator – ORANGE 6Timer Mode Indicator – ORANGE Indoor Unit (when the front panel is opened) 1Front Panel 2Air Filters 3Air Purifying Filter Outdoor Unit1Air Intake Vents 2Ground Terminal (Inside cover) 3Piping 4Connecting Cable 5Drain Hose 6Air Outlet Vents 1 2 3 4 5 76 2131 62 5 34 POWERFUL POWERFUL ECONOMY ECONOMYPOWER POWER TIMER TIMER SLEEP SLEEPPOWERFUL POWERFUL ECONOMY ECONOMY POWERPOWER TIMER TIMER SLEEP SLEEP 123 65 4 C H E C K TEMPAUTUTO ONOFF AUTUTODRDRYFANANCOOLCOOL FAN AUT UTOAUTUTO R E S E T B A T T E R Y C L O C KMODESLEEPECONOMYFAN SPEED A IR S W IN G OFF CANCELON SET Step12 3TIMER+ POWERFUL OFF/ON
ENGLISH4 NAME OF EACH PARTRemote ControlRemote Control Signal. •Make sure it is not obstructed. •Maximum distance : 10 m (32.8 ft.). •Signal received sound. One short beep or one long beep. Notes for Remote Control. •Do not throw or drop. •Do not get it wet. •Certain type of fluorescent lamps may affect signal reception. Consult your dealer. CHECK TEMP AUTO ONOFFAUTODRYFAN COOLFAN AUTOAUTO RESET CLOCK MODESLEEP ECONOMY FAN SPEED AIR SWINGOFF CANCEL ON SET 12 3 TIMER OFF/ON POWERFUL # !$%^$* & 3587906 4 ( 21 How to Insert the Batteries1 Slide down the remote control cover completely 2 Insert the batteries –Be sure the direction is correct –12.00 at display - flashing •Set the current time (CLOCK) immediately to prevent battery exhaustion. About the batteries •Can be used for approximately one year. Observe the following when replacing the batteries •Replace with new batteries of the same type. •Do not use rechargeable batteries (Ni-Cd). •Remove the batteries if the unit is not going to be used for a long period. 1Signal Transmitter 2Operation Display 3Powerful Mode Operation Button 4Room Temperature Setting Button (self-illuminating button) 5Operation Mode Selection Button 6Economy Mode Operation Button 7Vertical Airflow Direction Button 8ON-Timer Button 9OFF-Timer Button 0Reset Point (Press with fine-tipped object to clear the memory) !OFF/ON Button (self-illuminating button) @Sleep Mode Operation Button #Fan Speed Selection Button $Horizontal Airflow Direction Button %Timer Set Button ^Timer Cancellation Button &Time-Setting Button *Clock Button (Remote Control Cover CHECK AUTO OF AUTO HEATDRY FA N COOLFA NAUTO AUTO RESETCLOCK AIR SWING OFF CANCEL 12 3TIMER POWERFUL AUTO MANUAL ECONOMY SLE ON SETFAN SPEED MODE 2 1 1.5V1.5V
5 PREPARATION BEFORE OPERATIONIndoor Unit1 Connect the power supply cord to an independent power supply 2 Open the front panel 3 Remove the air filters 4 Fit the air purifying filters in place 5 Insert the air filters 6 Close the front panel Remote Control –To set the current time 1 Press 1. 2 Then press 2 to increase or decrease the time. 3 Press 1 again. Set time at display will light up. CHECK AUTO AUTO HEAT DRY FANCOOL FA NAUTO RESET CLOCK FAN SPEED AIR SWINGOFF CANCEL ON SET 12 3 TIMER 1 2 621 4 5 3 HOW TO OPERATETo start the operation •Press 1. •POWER indicator (green) on the indoor unit will light up. •To stop, press once more. Setting Mode •Press 2 to select:- AUTO–Automatic Operation COOL–Cooling Operation DRY–Soft Dry Operation FAN–Air Circulation Operation OFFON HEATDRY FAN COOL CHECK TEMP AUTOAU T UTO FA N AN AU T UTOAUT UTO RESETCLOCK AIR SWING OFF CANCEL 12 3TIMER OFF/ON POWERFULECONOMY SLEEP ON SETFAN SPEED MODE2 3 5 1 6 4 Setting Temperature •Press 3 to increase or decrease the temperature. •The temperature can be set between 60°F ~ 86°F. •Recommended temperature: •During AUTO Operation, press 3 to select:- •Operation with 4°F higher than the standard temperature. •Operation with the standard temperature. •Operation with 4°F lower than the standard temperature. Standard Temperature •Once the Automatic Operation is selected, the indoor temperature sensor operates automatically to select the desired operation mode with Cooling or Soft Dry. •After the operation mode has been selected, the mode does not change. Operation Cooling Soft DryStandard temperature 77°F 72°F Indoor temperature 73°F COOL DRY 75°F ~ 78°F 2°F ~ 4°F Lower than the room temperature
ENGLISH6 Setting the Fan Speed •Press 4 to select:- FAN–Low Fan Speed FAN–Medium Fan Speed FAN–High Fan Speed AUTO FAN–Automatic Fan Speed The speed of the indoor fan is adjusted automatically according to the operation. The indoor fan stops occasionally during cooling operation. Setting the Vertical Airflow Direction •Press 5 to select:- •Swing up/down automatically.Setting the Horizontal Airflow Direction •Press 6 to select:- Notes •If the unit is not going to be used for an extended period of time, turn off the main power supply. If it is left at the ON position, approximately 2.5 W of electricity will be used even if the indoor unit has been turned off with the remote control. •If operation is stopped, then restart immediately, the unit will resume operation only after 3 minutes.Operation Details COOL – Cooling Operation •To set the room temperature at your preference cooling comfort. AUTO – Automatic Operation •Sense indoor temperature to select the optimum mode. •Temperature is not displayed on the remote control during AUTO operation. DRY – Soft Dry Operation •A very gentle Cooling Operation, prior to dehumidification. It does not lower the room temperature. •During Soft Dry operation, the indoor fan operates at Low fan speed. FAN – Air Circulation Operation •When the room temperature reaches the set temperature, operation commences at Low airflow volume. It stops when the room temperature drops to 4°F below the set temperature. (It is useful when using a heater). AUTO •Swing left/right automatically. AU TO AUTO AUTOHorizontal Airflow Direction Indoor Unit Remote Control
7 SETTING THE TIMEREnsure that the current time is correct before setting the timer. The timer cannot be set if the time display is flashing. ON-TIMER Operation To start the air conditioner operation automatically. •Press 1 to set the operation. •Press 2 to increase or decrease the time. •Then press 3. •To cancel this operation, press 4. OFF-TIMER Operation To stop the air conditioner operation automatically. •Press 5 to set the operation. •Press 2 to increase or decrease the time. •Then press 3. •To cancel this operation, press 4. Timer Mode Operation Details •When the ON-Timer is set, operation will start before the actual set time. This is to enable the room temperature reaches the set temperature at the set time. •Once the ON-Timer is set, operation will start at the set time everyday. •The current time is not displayed when the timers are set. •When both timers are used together, the TIMER mode indicator on the indoor unit remains lit even when the operation is stopped by the OFF-TIMER. CONVENIENCE OPERATIONSleep Mode Operation To obtain a comfortable room temperature while sleeping:- •Press 6. •Sleep mode indicator on the indoor unit will light up. •To cancel this operation, press once more. Sleep Mode Operation Details •When the room temperature reaches the set temperature, the airflow volume will change to low automatically. •Sleep Mode Operation time is 8 hours. •When used together with the timer, the timer has a priority. Economy Mode Operation To save electrical power consumption. Please use this mode when the room has reached your desired temperature. •Press 7. *Economy mode indicator (green) on the indoor unit will light up. •Press once more to cancel this operation. Powerful Mode Operation To obtain the set temperature quickly. •Press 8. *Powerful mode indicator (orange) on the indoor unit will light up. *Powerful mode will operate for 15 minutes only. •To cancel this operation, press once more. Economy / Powerful Mode Operation Details•Economy and Powerful operation cannot be selected simultaneously. •The changes of the temperature and airflow volume are automatic. •The remote control display remains unchanged. •If sleep button or operation mode button is pressed, economy or powerful operation will be cancelled. •During FAN – Air circulation operation, the powerful and economy operation are not available. CHECK AUTO AUTO HEAT DRY FANCOOL FA NAUTO RESET CLOCK MODESLEEP ECONOMY FAN SPEED AIR SWINGOFF CANCEL ON SET 12 3 TIMER OFF/ON POWERFUL 364 175 28 Airflow volume Super Low Super High Economy Mode Operation Powerful Mode OperationTemperature 1°F higher than set temp. 5°F lower than set temp. COOL, DRY, 15 minutes AUTO in advance Time Approx. 1°F increase. Temperature Sleep Operation button is pressed.Sleep shift operation starts. 0~1 hour after approx. 8 hours of sleep shift operation, it will stop automatically. Approx. 1°F increase. •Cooling or Soft Dry Operation for sleep shift operation will start to avoid overcooling. S e t t i n gT e m p e r a t u r e← 1 hour →
ENGLISH8 Pre-season InspectionIs the discharged air cold? Operation is normal if 15 minutes after the start of operation, the difference between the air intake and outlet vents temperature is:- Are the air intake or outlet vents of the indoor or outdoor units obstructed? Are the remote control batteries weak? If the remote control display appears weak, replace the batteries.When the Air Conditioner is Not Used for an Extended Period of Time 1 To dry the internal parts of the indoor unit, operate the unit for 2 - 3 hours using:- 2 Turn off the power supply and unplug. Note: If the unit is not switched off by the remote control, it will start operating when you plug in (because the unit is equipped with Auto Restart Control). 3 Remove the remote control batteries. Recommended Inspection •After used over several seasons, the unit will become dirty and thus decreases the unit’s performance. Depending on the operation conditions, a dirty unit may produce odour and dust may pollute dehumidification system. Therefore, a seasonal inspection is recommended in addition to regular cleaning. (Consult an authorized dealer). CARE AND MAINTENANCECleaning the Indoor Unit and Remote Control •Wipe gently with a soft, dry cloth. •Do not use water hotter than 104˚F or polishing fluid to clean the unit. Cleaning the Air Filter (Recommendation:- If the unit is operated in a dusty environment, clean the filters every two weeks, continuous use of this dirty filters will reduce cooling efficiency) 1 Remove dirt using a vacuum cleaner. 2 Wash back of the air filter with water. 3 If badly soiled, wash it with soap or a mild household detergent. 4 Let it dry and reinstall it. Be sure the “FRONT” mark is facing you. *Damaged air filter. Consult the nearest authorized dealer. Part No.: CWD001049. •Do not use benzene, thinner, scouring powder or clothes soaked in caustic chemical to clean the unit. Cleaning the Front Panel(Must be removed before washing)1 Raise the front panel higher than the horizontal and pull to remove it. 2 Gently wash with water and a sponge. •Do not press the front panel too hard when washing. •When use kitchen cleaning fluid (neutral detergent), rinse throughly. •Do not dry the front panel under direct sunlight. 3 To fix the front panel, raise the front panel horizontally, match the protruding portion on the indoor unit to the fulcrum and push into place. Air Purifying FiltersSolar Refreshing Deodorizing Filter •Used to remove unpleasant odour and deodorize the air in the room. •Reusable. •Vacuum, place under direct sunlight for 6 hours and fit it back in place. (Recommended : every 6 months) Catechin Air Purifying Filter •The filter is coated with catechin to prevent growth of bacteria and viruses. •Reusable. •Vacuum and fit it back in place (Recommended : every 6 months) •Recommended to change these filters every 3 years. Do not reuse damaged filters. Consult the nearest authorized dealer to purchase a new filter. Catechin Air Purifying Filter No.: CZ-SF70P Solar Refreshing Deodorizing Filter No.: CZ-SFD70P •If you operate the air conditioner with dirty filters:- –Air is not purified –Cooling capacity decreases –Foul odour is emitted COOL – 14°F or above FAN operation Fulcrum Protruding portion on indoor unit 2 Remove the air filters1 Raise the front panel Catechin Air Purifying FilterSolar Refreshing Deodorizing Filter
9 HELPFUL INFORMATIONAuto Operation Button Automatic Operation •If the remote control fails to function or has been misplaced, press the Auto Operation button to start the Automatic operation. •The Automatic operation will be activated immediately once the Auto operation button is pressed. However, temperature cannot be adjusted in this operation. •The power indicator on the indoor unit will blink until the operation mode is selected automatically. •To cancel this operation, press once more. Remote Control Signal Receiving Sound •To switch off the beep (Signal Receiving Sound), press the Auto Operation button for 10 seconds continuously or longer. “Beep”, “beep” sound will be heard at the tenth seconds. Note:“Beep” sound will be heard at the fifth seconds; However please press continuously until you heard “beep”, “beep” sound. •Repeat the above steps if you want to switch on the Signal Receiving Sound. (This is for Servicing purposes only.) Note: If you press this button continuously for 5 to 10 seconds, Test Run operation will be performed. A “beep” sound will be heard at the fifth seconds indicating the Test Run starts to operate. POWERFUL POWERFUL ECONOMY ECONOMYPOWER POWER TIMER TIMER SLEEP SLEEPPOWERFUL POWERFUL ECONOMY ECONOMY POWERPOWER TIMER TIMER SLEEP SLEEP Auto Restart Control •If power is resumed after a power failure, the operation will restart automatically after 3 - 5 1/2 minutes. •Operation will be restarted automatically under the previous operation mode and airflow direction when power is resumed as the operation is not stopped by the remote control. Timer Setting •When power failure occurs, the timer setting will be cancelled. Once power is resumed, reset the timer. Thunder and Lightning •This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from being damaged by abnormally strong lightning activity, you may switch off the main power supply and unplug from power socket. ENERGY SAVING AND OPERATION HINTSSetting the Temperature •Approximately 10% of electricity can be saved. •Set the temperature 2°F higher than the desired temperature. Air Filters and Air Purifying Filters •Clean the air filters every 2 weeks and the Air Purifying Filters every 6 months. •Dirty filters may reduces cooling efficiency. Keep All Doors and Windows Closed •Otherwise, cooling performance will be reduced and electricity cost is wasted. Outdoor Unit •Do not block the air outlet vents. Otherwise, it will lower the cooling performance. Timer and Sleep Mode •To prevent wastage of electricity, use sleep mode when sleeping or Timer when going out. Avoid Direct Sunlight •Keep curtains or drapes closed to avoid direct sunlight during cooling operation. • Raise the front panel and press.