    							3.2. CS-W24BD3P / CU-W24BBP5
    ITEM / MODELIndoor UnitOutdoor unit
    Main BodyCS-W24BD3PCU-W24BBP5
    Cooling CapacitykW6.30
    (BTU/h)(21,500)
    Heating CapacitykW7.10
    (BTU/h)(24,200)
    Refrigerant Charge-lessm30
    Standard Air Volume for High Speedm3/minHi 20
    cfmHi 706
    External Static PressuremmAqHi 5-
    PaHi 49
    Air InletBackward SuctionBack sided Suction
    Air OutletFront blow-outFront blow-out
    Outside Dimension (H x W x D)mm270 x (1000 + 100) x 650900 x 900 x 320
    Net Weightkg (lbs)40 (88)81 (179)
    Piping
    ConnectionRefrigerantGasmm (inch)O.D Ø 15.88 (5/8) Flared Type
    Liquidmm (inch)O.D Ø 6.35 (1/4) Flared Type
    DrainmmFemale screw RC1 (PT1)I.DØ 20 x 1
    CompressorType, Number of Set-Hermetic-1 (Rotary), 1
    Starting Method-Direct on-line starting
    MotorType-2-pole single phase induction motor
    Rated OutputkW-1.9
    FanType, Number of SetSirocco fanProp. fan
    Air Volume ControlThree-Step and Auto mode-
    (Remote Control)
    MotorType4-pole single phase induction motor6-pole single phase induction motor
    Rated OutputkW0.0850.05
    Air-heat ExchangerX-Louvre-fintypeX-Louvre-fintype
    Refrigerant ControlCapillary tubeCapillary tube
    Refrigerant Oil (Charged)L-MEL56 (1.3)
    Refrigerant (Charged)kg (oz)-R407C 2.8 (99)
    Running
    AdjustmentControl SwitchWired RemoteControl-
    Room Temperatu reThermosta t (Main Body)-
    Safety DevicesInternal protector for compressor, Internal thermostat for F.M, Crankcase
    heater, High pressure switch, Current Transformer
    Noise LeveldB (A)Hi 39 Lo 33Cooling 52, Heating 53
    Power level dBHi 54 Lo 48Cooling 65, Heating 66
     1. Coolin g capacities are based on indoor temp. 27°C D.B. (80.6°F D.B.), 19.0°CW.B.(66.2°F W.B.) and outdoor air temp. 35°C
    D.B. (95°F D.B.), 24°CW.B.(75.2°F W.B.)
     2. Heating capacities are based on indoor temp. 20°C D.B. (68.0°F D.B.) and outdoor air temp. 7°C D.B. (44.6°F D.B.), 6°CW.B.
    (42.8°F D.B.)
    ELECTRICAL DATA (50Hz)
    MODEL / ITEMCS-W24BD3P/CU-W24BBP5
    Condition by JIS B 8615
    VoltsV220230240
    PhaseSingleSingleSingle
    Input PowerkWCool2.562.562.56
    Heat2.602.602.60
    Running CurrentACool11.7011.2010.80
    Heat11.9011.4010.90
    Starting CurrentA646668
    Power Factor%Cool999999
    Heat999999
    *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
    PanasonicPower sourceAC, 1~220V, 230V, 240V 50Hz
    11 
    						
    							3.3. CS-W28BD3P / CU-W28BBP5
    ITEM / MODELIndoor UnitOutdoor unit
    Main BodyCS-W28BD3PCU-W28BBP5
    Cooling CapacitykW7.10
    (BTU/h)(24,200)
    Heating CapacitykW8.00
    (BTU/h)(27,300)
    Refrigerant Charge-lessm30
    Standard Air Volume for High Speedm3/minHi 25
    cfmHi 883
    External Static PressuremmAqHi 5-
    PaHi 49
    Air InletBackward SuctionBack sided Suction
    Air OutletFront blow-outFront blow-out
    Outside Dimension (H x W x D)mm270 x (1000 + 100) x 650900 x 900 x 320
    Net Weightkg (lbs)40 (88)82 (181)
    Piping
    ConnectionRefrigerantGasmm (inch)O.D Ø 15.88 (5/8) Flared Type
    Liquidmm (inch)O.D Ø 9.52 (3/8) Flared Type
    DrainmmFemale screw RC1 (PT1)I.DØ 20 x 1
    CompressorType, Number of Set-Hermetic-1 (Rotary), 1
    Starting Method-Direct on-line starting
    MotorType-2-pole single phase induction motor
    Rated OutputkW-2.0
    FanType, Number of SetSirocco fanProp. fan
    Air Volume ControlThree-Step and Auto mode-
    (Remote Control)
    MotorType4-pole single phase induction motor6-pole single phase induction motor
    Rated OutputkW0.1150.05
    Air-heat ExchangerX-Louvre-fintypeX-Louvre-fintype
    Refrigerant ControlCapillary tubeCapillary tube
    Refrigerant Oil (Charged)L-MEL56 (1.3)
    Refrigerant (Charged)kg (oz)-R407C 3.3 (116)
    Running
    AdjustmentControl SwitchWired RemoteControl-
    Room Temperatu reThermosta t (Main Body)-
    Safety DevicesHead thermostat for compressor, Internal thermostat for F.M, Crankcase
    heater, High pressure switch, Current Transformer
    Noise LeveldB (A)Hi 40 Lo 34Cooling 53, Heating 54
    Power level dBHi 55 Lo 49Cooling 66, Heating 67
     1. Coolin g capacities are based on indoor temp. 27°C D.B. (80.6°F D.B.), 19.0°CW.B.(66.2°F W.B.) and outdoor air temp. 35°C
    D.B. (95°F D.B.), 24°CW.B.(75.2°F W.B.)
     2. Heating capacities are based on indoor temp. 20°C D.B. (68.0°F D.B.) and outdoor air temp. 7°C D.B. (44.6°F D.B.), 6°C W.B.
    (42.8°F D.B.)
    ELECTRICAL DATA (50Hz)
    MODEL / ITEMCS-W28BD3P/CU-W28BBP5
    Condition by JIS B 8615
    VoltsV220230240
    PhaseSingleSingleSingle
    Input PowerkWCool2.862.862.86
    Heat3.023.023.02
    Running CurrentACool13.112.512.5
    Heat13.813.212.7
    Starting CurrentA687072
    Power Factor%Cool999995
    Heat999999
    *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
    PanasonicPower sourceAC, 1~220V, 230V, 240V 50Hz
    12 
    						
    							3.4. CS-W28BD3P / CU-W28BBP8
    ITEM / MODELIndoor UnitOutdoor unit
    Main BodyCS-W28BD3PCU-W28BBP8
    Cooling CapacitykW7.10
    (BTU/h)(24,200)
    Heating CapacitykW8.00
    (BTU/h)(27,300)
    Refrigerant Charge-lessm30
    Standard Air Volume for High Speedm3/minHi 35
    cfmHi 1236
    External Static PressuremmAqHi 5-
    PaHi 49
    Air InletBackward SuctionBack sided Suction
    Air OutletFront blow-outFront blow-out
    Outside Dimension (H x W x D)mm270 x (1000 + 100) x 6501220 x 900 x 320
    Net Weightkg (lbs)40 (88)82 (181)
    Piping
    ConnectionRefrigerantGasmm (inch)O.D Ø 19.05 (3/4) Flared Type
    Liquidmm (inch)O.D Ø 9.52 (3/8) Flared Type
    DrainmmFemale screw RC1 (PT1)I.DØ 20 x 1
    CompressorType, Number of Set-Hermetic-1 (Rotary), 1
    Starting Method-Direct on-line starting
    MotorType-2-pole 3-phase induction motor
    Rated OutputkW-2.0
    FanType, Number of SetSirocco fanProp. fan
    Air Volume ControlThree-Step and Auto mode-
    (Remote Control)
    MotorType4-pole single phase induction motor6-pole single phase induction motor
    Rated OutputkW0.1150.05
    Air-heat ExchangerX-Louvre-fintypeX-Louvre-fintype
    Refrigerant ControlCapillary tubeCapillary tube
    Refrigerant Oil (Charged)L-MEL56 (1.3)
    Refrigerant (Charged)kg (oz)-R407C 3.3 (116)
    Running
    AdjustmentControl SwitchWired RemoteControl-
    Room Temperatu reThermosta t (Main Body)-
    Safety DevicesInternal protector for compressor, Internal thermostat for F.M, Crankcase
    heater, High pressure switch, Current Transformer
    Noise LeveldB (A)Hi 40 Lo 34Cooling 53, Heating 54
    Power level dBHi 55 Lo 49Cooling 66, Heating 67
     1. Coolin g capacities are based on indoor temp. 27°C D.B. (80.6°F D.B.), 19.0°CW.B.(66.2°F W.B.) and outdoor air temp. 35°C
    D.B. (95°F D.B.), 24°CW.B.(75.2°F W.B.)
     2. Heating capacities are based on indoor temp. 20°C D.B. (68.0°F D.B.) and outdoor air temp. 7°C D.B. (44.6°F D.B.), 6°CW.B.
    (42.8°F D.B.)
    ELECTRICAL DATA (50Hz)
    MODEL / ITEMCS-W28BD3P/CU-W28BBP8
    Condition by JIS B 8615
    VoltsV380400415
    Phase3N3N3N
    Input PowerkWCool2.722.722.72
    Heat2.862.862.86
    Running CurrentACool4.604.604.60
    Heat4.504.504.50
    Starting CurrentA282930
    Power Factor%Cool908582
    Heat979288
    *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
    PanasonicPower sourceAC, 3N~380V, 400V, 415V 50Hz
    13 
    						
    							3.5. CS-W34BD3P / CU-W34BBP8
    ITEM / MODELIndoor UnitOutdoor unit
    Main BodyCS-W34BD3PCU-W34BBP8
    Cooling CapacitykW10.00
    (BTU/h)(34,100)
    Heating CapacitykW11.20
    (BTU/h)(38,200)
    Refrigerant Charge-lessm30
    Standard Air Volume for High Speedm3/minHi 35
    cfmHi 953
    External Static PressuremmAqHi 5-
    PaHi 49
    Air InletBackward SuctionBack sided Suction
    Air OutletFront blow-outFront blow-out
    Outside Dimension (H x W x D)mm270 x (1500 + 100) x 6501220 x 900 x 320
    Net Weightkg (lbs)54 (119)97 (214)
    Piping
    ConnectionRefrigerantGasmm (inch)O.D Ø 19.05 (3/4) Flared Type
    Liquidmm (inch)O.D Ø 9.52 (3/8) Flared Type
    DrainmmFemale screw RC1 (PT1)I.DØ 20 x 1
    CompressorType, Number of Set-Hermetic-1 (Scroll), 1
    Starting Method-Direct on-line starting
    MotorType-2-pole 3 phase induction motor
    Rated OutputkW-3.0
    FanType, Number of SetSirocco fanProp. fan
    Air Volume ControlThree-Step and Auto mode-
    (Remote Control)
    MotorType4-pole single phase induction motor6-pole single phase induction motor
    Rated OutputkW0.150.05 x 2
    Air-heat ExchangerX-Louvre-fintypeX-Louvre-fintype
    Refrigerant ControlCapillary tubeCapillary tube
    Refrigerant Oil (Charged)L-MMMAPOE (1.3)
    Refrigerant (Charged)kg (oz)-R407C 3.3 (116)
    Running
    AdjustmentControl SwitchWired RemoteControl-
    Room Temperatu reThermosta t (Main Body)-
    Safety DevicesInternal protector for compressor, Internal thermostat for F.M, Crankcase
    heater, High pressure switch, Current Transformer
    Noise LeveldB (A)Hi 42 Lo 37Cooling 56, Heating 58
    Power level dBHi 57 Lo 52Cooling 69, Heating 71
     1. Coolin g capacities are based on indoor temp. 27°C D.B. (80.6°F D.B.), 19.0°CW.B.(66.2°F W.B.) and outdoor air temp. 35°C
    D.B. (95°F D.B.), 24°CW.B.(75.2°F W.B.)
     2. Heating capacities are based on indoor temp. 20°C D.B. (68.0°F D.B.) and outdoor air temp. 7°C D.B. (44.6°F D.B.), 6°C W.B.
    (42.8°F D.B.)
    ELECTRICAL DATA (50Hz)
    MODEL / ITEMCS-W34BD3P/CU-W34BBP8
    Condition by JIS B 8615
    VoltsV380400415
    Phase3N3N3N
    Input PowerkWCool3.883.883.88
    Heat4.074.074.07
    Running CurrentACool6.26.26.2
    Heat6.56.56.5
    Starting CurrentA394142
    Power Factor%Cool959087
    Heat959087
    *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
    PanasonicPower sourceAC, 3N~380V, 400V, 415V 50Hz
    14 
    						
    							3.6. CS-W43BD3P / CU-W43BBP8
    ITEM / MODELIndoor UnitOutdoor unit
    Main BodyCS-W43BD3PCU-W43BBP8
    Cooling CapacitykW12.50
    (BTU/h)(42,600)
    Heating CapacitykW14.0
    (BTU/h)(47,700)
    Refrigerant Charge-lessm30
    Standard Air Volume for High Speedm3/minHi 40
    cfmHi 1413
    External Static PressuremmAqHi 5-
    PaHi 49
    Air InletBackward SuctionBack sided Suction
    Air OutletFront blow-outFront blow-out
    Outside Dimension (H x W x D)mm270 x (1500 + 100) x 6501220 x 1100 x 320
    Net Weightkg (lbs)55 (121)114 (251)
    Piping ConnectionRefrigerantGasmm (inch)O.D Ø 19.05 (3/4) Flared Type
    Liquidmm (inch)O.D Ø 9.52 (3/8) Flared Type
    DrainmmFemale screw RC1 (PT1)I.DØ 20 x 1
    CompressorType, Number of Set-Hermetic-1 (Scroll), 1
    Starting Method-Direct on-line starting
    MotorType-2-pole 3 phase induction motor
    Rated OutputkW-3.75
    FanType, Number of SetSirocco fanProp. fan
    Air Volume ControlThree-Step and Auto mode-
    (Remote Control)
    MotorType4-pole single phase induction motor6-pole single phase induction motor
    Rated OutputkW0.20.055 x 2
    Air-heat ExchangerX-Louvre-fintypeX-Louvre-fintype
    Refrigerant ControlCapillary tubeCapillary tube
    Refrigerant Oil (Charged)L-MMMAPOE (2.0)
    Refrigerant (Charged)kg (oz)-R407C 3.6 (127)
    Running
    AdjustmentControl SwitchWired RemoteControl-
    Room Temperatu reThermosta t (Main Body)-
    Safety DevicesInternal protector for compressor, Internal thermostat for F.M, Crankcase
    heater, High pressure switch, Current Transformer
    Noise LeveldB (A)Hi 43 Lo 39Cooling 56, Heating 58
    Power level dBHi 58 Lo 54Cooling 69, Heating 71
     1. Coolin g capacities are based on indoor temp. 27°C D.B. (80.6°F D.B.), 19.0°CW.B.(66.2°F W.B.) and outdoor air temp. 35°C
    D.B. (95°F D.B.), 24°CW.B.(75.2°F W.B.)
     2. Heating capacities are based on indoor temp. 20°C D.B. (68.0°F D.B.) and outdoor air temp. 7°C D.B. (44.6°F D.B.), 6°CW.B.
    (42.8°F D.B.)
    ELECTRICAL DATA (50Hz)
    MODEL / ITEMCS-W43BD3P/CU-W43BBP8
    Condition by JIS B 8615
    VoltsV380400415
    Phase3N3N3N
    Input PowerkWCool4.494.494.49
    Heat4.664.664.66
    Running CurrentACool7.87.87.8
    Heat8.08.08.0
    Starting CurrentA585858
    Power Factor%Cool878380
    Heat898481
    *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
    PanasonicPower sourceAC, 3N~380V, 400V, 415V 50Hz
    15 
    						
    							4 SPECIFICATION (COOLING ONLY TYPE)
    4.1. CS-W18BD3P / CU-V18BBP5
    ITEM / MODELIndoor UnitOutdoor unit
    Main BodyCS-W18BD3PCU-V18BBP5
    Cooling CapacitykW5.00
    (BTU/h)(17,100)
    Refrigerant Charge-lessm30
    Standard Air Volume for High Speedm3/minHi 17-
    cfmHi 600
    External Static PressuremmAqHi 5-
    PaHi 49
    Air InletBackward SuctionBack sided Suction
    Air OutletFront blow-outFront blow-out
    Outside Dimension (H x W x D)mm270 x (780 + 100) x 650900 x 900 x 320
    Net Weightkg (lbs)34 (75)72 (159)
    Piping ConnectionRefrigerantGasmm (inch)O.D Ø 12.7 (1/2) Flared Type
    Liquidmm (inch)O.D Ø 6.35 (1/4) Flared Type
    DrainmmFemale screw RC1 (PT1)I.DØ 20 x 1
    CompressorType, Number of Set-Hermetic-1 (Rotary), 1
    Starting Method-Direct on-line starting
    MotorType-2-pole single phase induction motor
    Rated OutputkW-1.3
    FanType, Number of SetSirocco fanProp. fan
    Air Volume ControlThree-Step and Auto mode-
    (Remote Control)
    MotorType4-pole single phase induction motor6-pole single phase induction motor
    Rated OutputkW0.0850.05
    Air-heat ExchangerX-Louvre-fintypeX-Louvre-fintype
    Refrigerant ControlCapillary tubeCapillary tube
    Refrigerant Oil (Charged)L-MEL56 (0.7)
    Refrigerant (Charged)kg (oz)-R407C 2.8 (99)
    Running
    AdjustmentControl SwitchWired RemoteControl-
    Room Temperatu reThermosta t (Main Body)-
    Safety DevicesInternal protector for compressor, Internal thermostat for F.M, Crankcase
    heater, High pressure switch, Current Transformer
    Noise LeveldB (A)Hi 37 Lo 3350
    Power level dBHi 52 Lo 4863
     1. Coolin g capacities are based on indoor temp. 27°C D.B (80.6°F D.B.), 19.0°CW.B.(66.2°F W.B.) and outdoor air temp. 35°C
    D.B. (95°F D.B.), 24°CW.B.(75.2°F W.B.)
    ELECTRICAL DATA (50Hz)
    MODEL / ITEMCS-W18BD3P/CU-V18BBP5
    Condition by JIS B 8615
    VoltsV220230240
    PhaseSingleSingleSingle
    Input PowerkWCool1.851.851.85
    Running CurrentACool8.508.207.90
    Starting CurrentA384042
    Power Factor%Cool999898
    *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
    PanasonicPower sourceAC, 1~220V, 230V, 240V 50Hz
    16 
    						
    							4.2. CS-W24BD3P / CU-V24BBP5
    ITEM / MODELIndoor UnitOutdoor unit
    Main BodyCS-W24BD3PCU-V24BBP5
    Cooling CapacitykW6.30
    (BTU/h)(21,500)
    Refrigerant Charge-lessm30
    Standard Air Volume for High Speedm3/minHi 20-
    cfmHi 706
    External Static PressuremmAqHi 5-
    PaHi 49
    Air InletBackward SuctionBack sided Suction
    Air OutletFront blow-outFront blow-out
    Outside Dimension (H x W x D)mm270 x (1000 + 100) x 650900 x 900 x 320
    Net Weightkg (lbs)40 (88)80 (176)
    Piping ConnectionRefrigerantGasmm (inch)O.D Ø 15.88 (5/8) Flared Type
    Liquidmm (inch)O.D Ø 6.35 (1/4) Flared Type
    DrainmmFemale screw RC1 (PT1)I.DØ 20 x 1
    CompressorType, Number of Set-Hermetic-1 (Rotary), 1
    Starting Method-Direct on-line starting
    MotorType-2-pole single phase induction motor
    Rated OutputkW-1.9
    FanType, Number of SetSirocco fanProp. fan
    Air Volume ControlThree-Step and Auto mode-
    (Remote Control)
    MotorType4-pole single phase induction motor6-pole single phase induction motor
    Rated OutputkW0.0850.05
    Air-heat ExchangerX-Louvre-fintypeX-Louvre-fintype
    Refrigerant ControlCapillary tubeCapillary tube
    Refrigerant Oil (Charged)L-MEL56 (1.3)
    Refrigerant (Charged)kg (oz)-R407C 2.8 (99)
    Running
    AdjustmentControl SwitchWired RemoteControl-
    Room Temperatu reThermosta t (Main Body)-
    Safety DevicesInternal protector for compressor, Internal thermostat for F.M, Crankcase
    heater, High pressure switch, Current Transformer
    Noise LeveldB (A)Hi 39 Lo 3352
    Power level dBHi 54 Lo 4865
     1. Coolin g capacities are based on indoor temp. 27°C D.B. (80.6°F D.B.), 19.0°CW.B.(66.2°F W.B.) and outdoor air temp. 35°C
    D.B. (95°F D.B.), 24°CW.B.(75.2°F W.B.)
    ELECTRICAL DATA (50Hz)
    MODEL / ITEMCS-W24BD2P/CU-V24BBP8
    Condition by JIS B 8615
    VoltsV220230240
    PhaseSingleSingleSingle
    Input PowerkWCool2.562.562.56
    Running CurrentACool11.7011.2010.80
    Starting CurrentA646668
    Power Factor%Cool999999
    *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
    PanasonicPower sourceAC, 1~220V, 230V, 240V 50Hz
    17 
    						
    							4.3. CS-W24BD3P / CU-V24BBP8
    ITEM / MODELIndoor UnitOutdoor unit
    Main BodyCS-W24BD3PCU-V24BBP8
    Cooling CapacitykW6.30
    (BTU/h)(21,500)
    Refrigerant Charge-lessm30
    Standard Air Volume for High Speedm3/minHi 20-
    cfmHi 706
    External Static PressuremmAqHi 5-
    PaHi 49
    Air InletBackward SuctionBack sided Suction
    Air OutletFront blow-outFront blow-out
    Outside Dimension (H x W x D)mm270 x (1000 + 100) x 650900 x 900 x 320
    Net Weightkg (lbs)40 (88)80 (176)
    Piping ConnectionRefrigerantGasmm (inch)O.D Ø 15.88 (5/8) Flared Type
    Liquidmm (inch)O.D Ø 6.35 (1/4) Flared Type
    DrainmmFemale screw RC1 (PT1)I.DØ 20 x 1
    CompressorType, Number of Set-Hermetic-1 (Rotary), 1
    Starting Method-Direct on-line starting
    MotorType-2-pole 3-phase induction motor
    Rated OutputkW-1.9
    FanType, Number of SetSirocco fanProp. fan
    Air Volume ControlThree-Step and Auto mode-
    (Remote Control)
    MotorType4-pole single phase induction motor6-pole single phase induction motor
    Rated OutputkW0.0850.05
    Air-heat ExchangerX-Louvre-fintypeX-Louvre-fintype
    Refrigerant ControlCapillary tubeCapillary tube
    Refrigerant Oil (Charged)L-MEL56 (1.3)
    Refrigerant (Charged)kg (oz)-R407C 2.8 (99)
    Running
    AdjustmentControl SwitchWired RemoteControl-
    Room Temperatu reThermosta t (Main Body)-
    Safety DevicesInternal protector for compressor, Internal thermostat for F.M, Crankcase
    heater, High pressure switch, Current Transformer
    Noise LeveldB (A)Hi 39 Lo 3352
    Power level dBHi 54 Lo 4865
     1. Coolin g capacities are based on indoor temp. 27°C D.B. (80.6°F D.B.), 19.0°CW.B.(66.2°F W.B.) and outdoor air temp. 35°C
    D.B. (95°F D.B.), 24°CW.B.(75.2°F W.B.)
    ELECTRICAL DATA (50Hz)
    MODEL / ITEMCS-W24BD3P/CU-V24BBP8
    Condition by JIS B 8615
    VoltsV380400415
    Phase3N3N3N
    Input PowerkWCool2.422.422.42
    Running CurrentACool4.104.104.10
    Starting CurrentA272829
    Power Factor%Cool858481
    *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
    PanasonicPower sourceAC, 3N~380V, 400V, 415V 50Hz
    18 
    						
    							4.4. CS-W28BD3P / CU-V28BBP5
    ITEM / MODELIndoor UnitOutdoor unit
    Main BodyCS-W28BD3PCU-V28BBP5
    Cooling CapacitykW7.10
    (BTU/h)(24,200)
    Refrigerant Charge-lessm30
    Standard Air Volume for High Speedm3/minHi 25-
    cfmHi 883
    External Static PressuremmAqHi 5-
    PaHi 49
    Air InletBackward SuctionBack sided Suction
    Air OutletFront blow-outFront blow-out
    Outside Dimension (H x W x D)mm270 x (1000 + 100) x 650900 x 900 x 320
    Net Weightkg (lbs)40 (88)81 (179)
    Piping ConnectionRefrigerantGasmm (inch)O.D Ø 15.88 (5/8) Flared Type
    Liquidmm (inch)O.D Ø 9.52 (3/8) Flared Type
    DrainmmFemale screw RC1 (PT1)I.DØ 20 x 1
    CompressorType, Number of Set-Hermetic-1 (Rotary), 1
    Starting Method-Direct on-line starting
    MotorType-2-pole single phase induction motor
    Rated OutputkW-2.0
    FanType, Number of SetSirocco fanProp. fan
    Air Volume ControlThree-Step and Auto mode-
    (Remote Control)
    MotorType4-pole single phase induction motor6-pole single phase induction motor
    Rated OutputkW0.1150.05
    Air-heat ExchangerX-Louvre-fintypeX-Louvre-fintype
    Refrigerant ControlCapillary tubeCapillary tube
    Refrigerant Oil (Charged)L-MEL56 (1.3)
    Refrigerant (Charged)kg (oz)-R407C 3.3 (116)
    Running AdjustmentControl SwitchWired RemoteControl-
    Room Temperatu reThermosta t (Main Body)-
    Safety DevicesInternal protector for compressor, Internal thermostat for F.M, Crankcase
    heater, High pressure switch, Current Transformer
    Noise LeveldB (A)Hi 40 Lo 3453
    Power level dBHi 55 Lo 4966
     1. Coolin g capacities are based on indoor temp. 27°C D.B. (80.6°F D.B.), 19.0°CW.B.(66.2°F W.B.) and outdoor air temp. 35°C
    D.B. (95°F D.B.), 24°CW.B.(75.2°F W.B.)
    ELECTRICAL DATA (50Hz)
    MODEL / ITEMCS-W28BD3P/CU-V28BBP5
    Condition by JIS B 8615
    VoltsV220230240
    PhaseSingleSingleSingle
    Input PowerkWCool2.862.862.86
    Running CurrentACool13.112.512.5
    Starting CurrentA687072
    Power Factor%Cool999995
    *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
    PanasonicPower sourceAC, 1~220V, 230V, 240V 50Hz
    19 
    						
    							4.5. CS-W28BD3P / CU-V28BBP8
    ITEM / MODELIndoor UnitOutdoor unit
    Main BodyCS-W28BD3PCU-V28BBP8
    Cooling CapacitykW7.10
    (BTU/h)(24,200)
    Refrigerant Charge-lessm30
    Standard Air Volume for High Speedm3/minHi 25-
    cfmHi 883
    External Static PressuremmAqHi 5-
    PaHi 49
    Air InletBackward SuctionBack sided Suction
    Air OutletFront blow-outFront blow-out
    Outside Dimension (H x W x D)mm270 x (1000 + 100) x 650900 x 900 x 320
    Net Weightkg (lbs)40 (88)81 (179)
    Piping ConnectionRefrigerantGasmm (inch)O.D Ø 15.88 (5/8) Flared Type
    Liquidmm (inch)O.D Ø 9.52 (3/8) Flared Type
    DrainmmFemale screw RC1 (PT1)I.DØ 20 x 1
    CompressorType, Number of Set-Hermetic-1 (Rotary), 1
    Starting Method-Direct on-line starting
    MotorType-2-pole 3-phase induction motor
    Rated OutputkW-2.0
    FanType, Number of SetSirocco fanProp. fan
    Air Volume ControlThree-Step and Auto mode-
    (Remote Control)
    MotorType4-pole single phase induction
    motor6-pole single phase induction motor
    Rated OutputkW0.1150.05
    Air-heat ExchangerX-Louvre-fintypeX-Louvre-fintype
    Refrigerant ControlCapillary tubeCapillary tube
    Refrigerant Oil (Charged)L-MEL56 (1.3)
    Refrigerant (Charged)kg (oz)-R407C 3.3 (116)
    Running AdjustmentControl SwitchWired RemoteControl-
    Room Temperatu reThermosta t (Main Body)-
    Safety DevicesInternal protector for compressor, Internal thermostat for F.M, Crankcase
    heater, High pressure switch, Current Transformer
    Noise LeveldB (A)Hi 40 Lo 3453
    Power level dBHi 55 Lo 4966
     1. Coolin g capacities are based on indoor temp. 27°C D.B. (80.6°F D.B.), 19.0°CW.B.(66.2°F W.B.) and outdoor air temp. 35°C
    D.B. (95°F D.B.), 24°CW.B.(75.2°F W.B.)
    ELECTRICAL DATA (50Hz)
    MODEL / ITEMCS-W28BD3P/CU-V28BBP8
    Condition by JIS B 8615
    VoltsV380400415
    Phase3N3N3N
    Input PowerkWCool2.722.722.72
    Running CurrentACool4.604.604.60
    Starting CurrentA282930
    Power Factor%Cool908582
    *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
    PanasonicPower sourceAC, 3N~380V, 400V, 415V 50Hz
    20 
    						