Home > Panasonic > Air Conditioner > Panasonic Cs W34bd2p Cs W43bd2p Series Repair Manual

Panasonic Cs W34bd2p Cs W43bd2p Series Repair Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Cs W34bd2p Cs W43bd2p Series Repair Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							APPLICABLE FOR ALL MODELS
    41 
    						
    							7 OPERATING INSTRUCTION
    7.1. Wired Remote Control
    Name and function of each part
    42 
    						
    							43 
    						
    							8 REFRIGERATION CYCLE
    8.1. Heating Model
    CS-W24BD2P / CU-W24BBP5
    CS-W28BD2P / CU-W28BBP5 , 8
    44 
    						
    							CS-W34BD2P / CU-W34BBP8
    CS-W43BD2P / CU-W43BBP8
    8.2. Cooling Only Model
    CS-W24BD2P /CU-V24BBP5 , 8
    45 
    						
    							CS-W28BD2P /CU-V28BBP5 , 8
    CS-W34BD2P / CU-V34BB P8
    CS-W43BD2P / CU-V43BB P8
    46 
    						
    							9 OPERATION RANGE
    The applicable voltage range for each unit is given in “thefollowing table”. The workingvoltage among the three phases
    must be balanced within 3% deviation from each voltage at the compressor terminals. The starting voltage must be higher
    than 85% of the rated voltage.
    Power Supply
    Model
    CU-Unit Main PowerApplicable VoltageModel
    CU-Unit Main PowerApplicable Voltage
    Phase, VoltsHzMaximumMinimumPhase, VoltsHzMaximumMinimum
    W24BBP5
    W28BBP5
    V24BBP5
    V28BBP51~22050242198W28BBP8
    W34BBP8
    W43BBP8
    V24BBP8
    V28BBP8
    V34BBP8
    V43BBP83N~38050418342
    1~230502532073N~40050440360
    1~240502642163N~41550457374
    Indoor and Outdoor Temperature
    
     
    Coolingonly type
    Model 50Hz ... V24BB P5 (8), V28BB P5 (8), V34BB P8, V43BB P8
    OperatingHzIndoor Temp. (D.B./W.B.) (°C)Outdoor Temp. (D.B./W.B.) (°C)
    MaximumMinimumMaximumMinimum
    Cooling5032/2321/1543/--5/-
    
     
    Heat pumptype
    Model 50Hz ...W24BBP5,W28BBP5 (8), W34BBP8,W43BBP8
    OperatingHzIndoor Temp. (D.B./W.B.) (°C)Outdoor Temp. (D.B./W.B.) (°C)
    MaximumMinimumMaximumMinimum
    Cooling5032/2321/1543/--5/-
    Heating5027/-16/-24/18-10/-
    47 
    						
    							Correction of cooling and heating capacities according to
    the connecting pipe length.
    The data of cooling capacities (marked on the name plate)
    are based on 7.5 metres connecting pipe and horizontal
    installation.
    (Cooling)
    Equivalent Length = actual pipe length +
    number of elbow x ELE + number of oil
    trap x ELO
    ELE: equiva lent length ofelbow.
    ELO: equivalent length of oil trap.
    10.2. REFRIGERANT ADDITIONAL
    CHARGE
     
        • 
    • •  • 
    The piping length exceeds 30 metres.
    APPLICABLE FOR ALLMODELS
    Before shipment, this air conditioner is filled with the rated
    amoun t of refrigerant subject to 30m piping length. (The
    rated amoun t of refrigerant is indicated on the name plate.)
    But when the piping length exceed s 30m, additio nal charge
    is required according to the following table.For other pipe length of other installation multiply
    by the following correction factor to determine the
    revised cooling capacity.
    (Heating)
    Outer diameter of gas
    side pipe mm (inch)
    9.520.18
    12.7 (1/2)0.20
    15.88 (5/8)0.25
    19.05 (3/4)0.35
    ModelRef. Charge
    2.5HP20g per 1m
    3~5HP50g per 1m
    Example:
    CS-W24BD2P
    In case of 30 m long pipe (one-way), the
    amoun t of refrigerant to be replenished is:
    (30 - 30) x 20 = 0g
    CS-W43BD2P
    In case of 50m long pipe (one-way), the
    amoun t of refrigerant to be replenished is:
    (50 - 30) x 50 = 1,000g
    10 PIPE LENGTH
    10.1. CORRECTION OF COOLING AND HEATING CAPACITIES
    48 
    						
    							10.3. Piping installation by existing piping
    
    Coolingonly type(50Hz)
    Model NameStandard piping specification
    Liquid piping (dia.mm)Gas piping (dia.mm)Gas charge-less length
    (m)Additional gas volume (g/m)
    CU-V24BBP56.3515.883020
    CU-V24BBP86.3515.883020
    CU-V28BBP59.5215.883050
    CU-V28BBP89.5215.883050
    CU-V34BBP89.5219.053050
    CU-V43BBP89.5219.053050
    
    Heat pumptype(50Hz)
    Model NameStandard piping specification
    Liquid piping (dia.mm)Gas piping (dia.mm)Gas charge-less length (m)Additional gas volume
    (g/m)
    CU-W24BBP56.3515.883020
    CU-W28BBP59.5215.883050
    CU-W28BBP89.5215.883050
    CU-W34BBP89.5219.053050
    CU-W43BBP89.5219.053050
    Attention
     
        • 
    • •  • 
    Please never decrease the gas piping size. (It causes the breakdown of the compressor)
     
        • 
    • •  • 
    The equivalent piping length and the cooling and heating capacity change rate are same as the standard piping
    specification.
    49 
    						
    							11 OPERATING CHARACTERISTIC
    HEAT PUMPMODEL
    ModelMain PowerCompressor MotorIndoor UnitOutdoor UnitElectrical Data (50Hz)
    SourceFan MotorFan MotorR.CIPT
    VoltageFrequencyS.C.R.C.(A)IPT(kW)R.C.IPTR.C.IPT(A)(kW)
    (V)(Hz)(A)COOL / HEATCOOL / HEAT(A)(kW)(A)(kW)COOL / HEATCOOL / HEAT
    CS-W24BD2P220506410.5 / 10.72.31 / 2.350.790.150.460.1011.7 / 11.92.56 / 2.60
    CU-W24BBP523050669.9 / 10.12.29 / 2.330.840.160.470.1111.2 / 11.42.56 / 2.60
    24050689.5 / 9.62.28 / 2.320.870.170.480.1110.8 / 10.92.56 / 2.60
    CS-W28BD2P220506811.9 / 12.62.60 / 2.760.770.160.460.1013.1 / 13.82.86 / 3.02
    CU-W28BBP5230507011.2 / 11.92.58 / 2.740.800.170.470.1112.5 / 13.22.86 / 3.02
    240507211.2 / 11.42.57 / 2.730.820.180.480.1112.5 / 12.72.86 / 3.02
    CS-W28BD2P38050284.19 / 4.092.46 / 2.600.770.160.460.104.60 / 4.502.72 / 2.86
    CU-W28BBP840050294.18 / 4.082.44 / 2.580.800.170.470.114.60 / 4.502.72 / 2.86
    41550304.17 / 4.072.43 / 2.570.820.180.480.114.60 / 4.502.72 / 2.86
    CS-W34BD2P38050393.94 / 4.243.39 / 3.581.350.290.910.206.20 / 6.503.88 / 4.07
    CU-W34BBP840050413.90 / 4.203.36 / 3.551.360.310.940.216.20 / 6.503.88 / 4.07
    41550423.86 / 4.163.33 / 3.521.370.320.970.236.20 / 6.503.88 / 4.07
    CS-W43BD2P38050586.91 / 7.113.91 / 4.081.670.360.990.227.80 / 8.004.49 / 4.66
    CU-W43BBP840050586.90 / 7.103.88 / 4.051.670.381.020.237.80 / 8.004.49 / 4.66
    41550586.90 / 7.103.85 / 4.021.660.391.040.257.80 / 8.004.49 / 4.66
    COOLING ONLY MODEL
    CS-W24BD2P220506410.52.310.790.150.460.1011.72.56
    CU-V24BBP523050669.92.290.840.160.470.1111.22.56
    24050689.52.280.870.170.480.1110.82.56
    CS-W24BD2P38050272.852.170.790.150.460.104.102.42
    CU-V24BBP840050282.792.150.840.160.470.114.102.42
    41550292.752.140.870.170.480.114.102.42
    CS-W28BD2P220506812.72.600.770.160.460.1013.12.86
    CU-V28BBP5230507012.12.580.800.170.470.1112.52.86
    240507212.12.570.820.180.480.1112.52.86
    CS-W28BD2P38050283.372.460.770.160.460.104.602.72
    CU-V28BBP840050293.332.440.800.170.470.114.602.72
    41550303.302.430.820.180.480.114.602.72
    CS-W34BD2P38050395.453.391.350.290.910.206.203.88
    CU-V34BBP840050415.433.361.360.310.940.216.203.88
    41550425.423.331.370.320.970.236.203.88
    CS-W43BD2P38050586.913.911.670.360.990.227.804.49
    CU-V43BBP840050586.903.881.670.381.020.237.804.49
    41550586.903.851.660.391.040.257.804.49
    Legend:
    S.C.: Starting Current
    R.C.: Runnin g Current
    IPT: Power Consumption
    50 
    						