Panasonic Cs Me5 7rkua Operating Instructions Manual
Here you can view all the pages of manual Panasonic Cs Me5 7rkua Operating Instructions Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 1
Français English F569978 Operating Instructions Air Conditioner Model No. Indoor Unit CS-ME5RKUA CS-ME7RKUA CS-E9RKUAW CS-E12RKUAW Outdoor Unit Single Split Multi Split CU-E9RKUA CU-E12RKUACU-2E18NBU CU-5E36QBU CU-3E19RBU CU-4E24RBU Operating Instructions Air Conditioner2-12 Thank you for purchasing Panasonic Air Conditioner. Installation instructions attached. Before operating the unit, read these operating instructions thoroughly and keep them for future reference. Instructions d’utilisation...
Page 2
2 Operation conditions Use this air conditioner under the following temperature range. DBT : Dry bulb temperature WBT : Wet bulb temperature Temperature (°F/°C)CS-ME5RKUA CS-ME7RKUA CS-E9RKUAW CS-E12RKUAWCU-E9RKUA CU-E12RKUACU-2E18NBU CU-5E36QBU CU-3E19RBU CU-4E24RBU DBT WBT DBT WBT DBT WBT COOL Max. 89.6 / 32 73.4 / 23 114.8 / 46 78.8 / 26 114.8 / 46 78.8 / 26 Min. 60.8 / 16 51.8 / 11 0 / -17.8 - / - 14.0 / -10 - / - HEAT Max. 86.0 / 30 - / - 75.2 / 24 64.4 / 18 75.2 / 24 64.4 / 18 Min. 60.8 / 16 - /...
Page 3
3 English Quick guide 123 Inserting the batteries 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries (can be used ~ 1 year) 3 Close the cover TIMER SET CANCEL ON OFF1 23 SETAC RC TIMER CANCEL ON OFF 13 SETCHECKRESETACRC 23 1 Clock setting 1 Press CLOCK 2 Set the time 3 Confi rm AUTO COMFORT MODE POWERFUL/ QUIET TEMP OFF/ON TIMER SET CANCEL ON OFF1 23 AIR SWING FAN SPEED SETAC RC ECONAVI FAN SPEED AIR SWINGAUTO HEAT COOL DRY FAN AUTOCOMFORT POWERFUL/QUIET TIMERSET...
Page 4
4 Safety precautions To prevent personal injury, injury to others or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classifi ed as below: WARNINGThis sign warns of death or serious injury. CAUTIONThis sign warns of injury or damage to property. The instructions to be followed are classifi ed by the following symbols: This symbol denotes an action that is PROHIBITED. These...
Page 5
5 English To prevent overheating, fi re or electric shock:• Do not share the same power outlet with other equipment. • Do not operate with wet hands. • Do not over bend the power supply cord. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualifi ed persons in order to avoid a hazard. It is strongly recommended to install this unit using an Earth Leakage Circuit Breaker (ELCB) or Ground Fault Interrupt (GFCI) or Appliance Leakage Current Interrupt...
Page 6
6 AUTO COMFORT MODE POWERFUL/ QUIET TEMP OFF/ON TIMER SET CANCEL ON OFF1 23 AIR SWING FAN SPEED SETAC RC ECONAVI FAN SPEED AIR SWINGAUTO HEAT COOL DRY FAN / TEMP OFF/ON TIMERSET CANCEL ON OFF 123 CHECK Remote control display Human activity sensor Remote control receiver and Indicator Auto OFF/ON button Use when remote control is misplaced or a malfunction occurs. Raise the front panel: • To use in AUTO mode, press the button once. • To use in COOL mode, press and hold the button until 1 beep is...
Page 7
7 English Note ECONAVI , POWERFUL/ QUIET , AUTO COMFORT • Can be activated in all modes and can be cancelled by pressing the respective button again. • Cannot be selected at the same time. To set the timer 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset times. TIMERSET CANCEL ON OFF1 23 AC CCANCEL 3 ACC 213 1Select ON or OFF timerExample: OFF at 11:50PM • Each time pressed: OFFAMCancel 2Set the time2PM 3Confi rmSET PM TIMER • To cancel ON or OFF timer,...
Page 8
8 Operation mode AUTO : During operation mode selection the POWER indicator blinks.Single• Unit selects operation mode every 10 minutes according to setting temperature and room temperature. Multi• Unit selects operation mode every 3 hours according to setting temperature, outdoor temperature and room temperature. HEAT : Unit takes a while to warm up. The POWER indicator blinks during this operation. COOL : Provides effi cient comfort cooling to suit your needs. DRY : Unit operates at low fan speed to...
Page 9
9 EnglishTo learn more... / Cleaning instructions Cleaning instructions To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. Dirty unit may cause malfunction and you may see error code “H99”. Please consult authorised dealer. • Switch off the power at the circuit breaker before cleaning. • Do not touch the aluminium fi n, sharp parts may cause injury. • Do not use benzene, thinner or scouring powder. • Use only soap ( pH 7) or neutral household...
Page 10
10 The following symptoms do not indicate malfunction. SymptomCause Mist emerges from indoor unit. • Condensation effect due to cooling process. Water fl owing sound during operation. • Refrigerant fl ow inside the unit. The room has a peculiar odour. • This may be due to damp smell emitted by the wall, carpet, furniture or clothing. Indoor fan stops occasionally during automatic fan speed setting.• This helps to remove the surrounding odour. Airfl ow continues even after operation has stopped.•...