Home > Panasonic > Air Conditioner > Panasonic Cs Me5 7rkua Operating Instructions Manual

Panasonic Cs Me5 7rkua Operating Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Cs Me5 7rkua Operating Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Français English
    F569978
    Operating Instructions
    Air Conditioner
    Model No.
    Indoor Unit
    CS-ME5RKUA
    CS-ME7RKUA
    CS-E9RKUAW
    CS-E12RKUAW
    Outdoor Unit
    Single Split Multi Split
    CU-E9RKUA
    CU-E12RKUACU-2E18NBU
    CU-5E36QBU
    CU-3E19RBU
    CU-4E24RBU
    Operating Instructions
    Air Conditioner2-12
    Thank you for purchasing Panasonic Air Conditioner.
    Installation instructions attached.
    Before operating the unit, read these operating 
    instructions thoroughly and keep them for future 
    reference.
    Instructions d’utilisation
    Climatiseur13-24
    Merci d’avoir acheté un climatiseur Panasonic
    Instructions d’installation en annexe.
    Avant d’utiliser le climatiseur, lire ces instructions 
    d’utilisation et les conserver pour s’y référer dans le 
    futur. 
    						
    							2
    Operation conditions
    Use this air conditioner under the following temperature range.
    DBT  : Dry bulb temperature
    WBT : Wet bulb temperature
    Temperature (°F/°C)CS-ME5RKUA
    CS-ME7RKUA
    CS-E9RKUAW
    CS-E12RKUAWCU-E9RKUA
    CU-E12RKUACU-2E18NBU
    CU-5E36QBU
    CU-3E19RBU 
    CU-4E24RBU 
    DBT WBT DBT WBT DBT WBT
    COOL Max. 89.6 / 32 73.4 / 23 114.8 / 46 78.8 / 26 114.8 / 46 78.8 / 26
    Min. 60.8 / 16 51.8 / 11 0 / -17.8 - / - 14.0 / -10 - / -
    HEAT Max. 86.0 / 30 - / - 75.2 / 24 64.4 / 18 75.2 / 24 64.4 / 18
    Min. 60.8 / 16 - / - -4 / -20 -5.8 / -21 5.0 / -15 3.2 / -16
    Power Supply
    Models NumberTime Delay 
    Circuit BreakerRated Volts
    CS-E9RKUAW / CU-E9RKUA 15 Amps
    208/230V CS-E12RKUAW / CU-E12RKUA 25 Amps
    CS-ME5RKUA / CS-ME7RKUA / CS-E9RKUAW / CS-E12RKUAW / CU-2E18NBU  25 Amps
    CS-ME5RKUA / CS-ME7RKUA / CS-E9RKUAW / CS-E12RKUAW / CU-5E36QBU  45 Amps
    CS-ME5RKUA / CS-ME7RKUA / CS-E9RKUAW / CS-E12RKUAW / CU-3E19RBU 30 Amps
    CS-ME5RKUA / CS-ME7RKUA / CS-E9RKUAW / CS-E12RKUAW / CU-4E24RBU 45 Amps
    Provide fast cooling, maximum comfort,
    clean air and optimise energy saving
    ECONAVI and AUTO COMFORT The Right Choice for Energy SavingEquipped with the human activity sensor, the air conditioner ensures to deliver cool or warm air to you, 
    and keeps the room consistently comfortable with minimum energy consumption.
    See “To learn more...” for details.
    Multi air conditioner systemMulti air conditioner systems save space by 
    letting you connect multiple indoor units to a 
    single outdoor unit.
    • For complete product features, please refer 
    catalogue.
    Indoor units
    Outdoor unit
    ( CU-2E18NBU, CU-5E36QBU, 
    CU-3E19RBU, CU-4E24RBU)  Indoor units
    • It is possible to operate the indoor units 
    individually or simultaneously. The priority 
    of operation is placed on the fi rst unit that 
    turned on.
    • During operation, HEAT and COOL modes 
    cannot activate at the same time for different 
    indoor units.
    • The power indicator blinks to indicate the 
    indoor unit is standing by for a different 
    operation mode. 
    						
    							3
    English
    Quick guide
    123
    Inserting the batteries
    1
      Pull out the back cover of 
    remote control
    2  Insert AAA or R03 batteries 
    (can be used ~ 1 year)
    3
      Close the cover
    TIMER
    SET
    CANCEL ON
    OFF1
    23
    SETAC
    RC
    TIMER
    CANCEL
    ON
    OFF
    13
    SETCHECKRESETACRC
    23
    1
    Clock setting
    1
      Press CLOCK
    2
      Set the time
    3
      Confi rm
    AUTO
    COMFORT
    MODE
    POWERFUL/
    QUIET
    TEMP
    OFF/ON
    TIMER
    SET
    CANCEL ON
    OFF1
    23
    AIR SWING
    FAN SPEED
    SETAC
    RC
    ECONAVI
    FAN
    SPEED
    AIR
    SWINGAUTO
    HEAT
    COOL
    DRY
    FAN
    AUTOCOMFORT
    POWERFUL/QUIET
    TIMERSET
    CANCEL
    ON
    OFF
    123
    AIR SWING
    FAN SPEED
    SETCHECKCLOCKRESETACRC
    ECONAVI
    FANSPEEDAIRSWING
    AUTOHEATCOOLDRYFAN
    1
    2
    3
    26ft/8m
    Basic operation
    1 Select the desired mode
    DRY AUTO HEAT
    COOLFA N
    2  Start/stop the operation
    POWER
    • Please note that the OFF 
    indication  is on to start. 
    3
      Select the desired temperature
    • Selection range (Not applicable 
    for FAN mode): 
    60°F ~ 86°F / 16°C ~ 30°C.
    • Operating the unit within the 
    recommended temperature may 
    save energy.
    HEAT : 68°F ~ 75°F / 20°C ~
      24°C. 
    COOL : 78°F ~ 82°F / 26°C ~
      28°C. 
    DRY : 2°F ~ 4°F / 1°C ~ 2°C
      lower than room
      temperature.
    • To dim or restore the unit’s indicator 
    brightness, press  and hold for
    5 seconds.
    • Use remote control within 26ft/8m 
    from the remote control receiver of 
    the indoor unit.
    The illustrations in this manual are for explanation purposes only 
    and may differ from the actual unit. They are subject to change 
    without notice for future improvement.
    Table of contents
    Safety precautions ...................4-5
    How to use...............................6-7
    To learn more...  .........................8
    Cleaning instructions ..................9
    Troubleshooting  ..................10-11
    Information................................12
    Accessories
    • Remote  control
    • AAA or R03 batteries × 2
    • Remote control holder
    • Screws for remote control 
    holder × 2 
    						
    							4
    Safety precautions
    To prevent personal injury, injury to others 
    or property damage, please comply with the 
    following: 
    Incorrect operation due to failure to follow 
    instructions below may cause harm or damage, 
    the seriousness of which is classifi ed as below:
    WARNINGThis sign warns of 
    death or serious 
    injury.
    CAUTIONThis sign warns of 
    injury or damage to 
    property.
    The instructions to be followed are classifi ed by 
    the following symbols:
    This symbol denotes an 
    action that is PROHIBITED.
    These symbols denote 
    actions COMPULSORY.
       WARNING
    Indoor unit and outdoor unit
    This appliance is not intended for use by 
    persons (including children) with reduced 
    physical, sensory or mental capabilities, or lack 
    of experience and knowledge, unless they have 
    been given supervision or instruction concerning 
    use of the appliance by a person responsible for 
    their safety. Children should be supervised to 
    ensure that they do not play with the appliance.
    Please consult authorised dealer or specialist to 
    clean the internal parts, repair, install, remove 
    and reinstall the unit. Improper installation and 
    handling will cause leakage, electric shock or fi re.
    Confi rm with authorised dealer or specialist on 
    usage of any specifi ed refrigerant type. 
    Using refrigerant type other than the specifi ed 
    may cause product damage, burst and injury etc.
    Do not install the unit in a potentially explosive 
    or fl ammable atmosphere. Failure to do so could 
    result in fi re.
    Do not insert your fi ngers or other 
    objects into the air conditioner indoor or 
    outdoor unit, rotating parts may cause 
    injury.
    Do not touch the outdoor unit during lightning, it 
    may cause electric shock.
    Do not expose yourself directly to cold air for a 
    long period to avoid excess cooling.
    Do not sit or step on the unit, you may 
    fall down accidentally.
    Remote control
    Do not allow infants and small children to play 
    with the remote control to prevent them from 
    accidentally swallowing the batteries.
    Power supply
    Do not use a modifi ed cord, 
    joint cord, extension cord or 
    unspecifi ed cord to prevent 
    overheating and fi re.
      
    Indoor unit
    Outdoor unit
    Power supply
    Remote control
    Air inletAir inlet
    Air inletAir inlet
    Air outletAir outlet
    Air outletAir outlet 
    						
    							5
    English
    To prevent overheating, fi re or electric shock:• Do not share the same power outlet with 
    other equipment.
    • Do not operate with wet hands. • Do not over bend the power supply cord.
    If the supply cord is damaged, it must be 
    replaced by the manufacturer, service agent 
    or similarly qualifi ed persons in order to avoid 
    a hazard.
    It is strongly recommended to install this 
    unit using an Earth Leakage Circuit Breaker 
    (ELCB) or Ground Fault Interrupt (GFCI) or 
    Appliance Leakage Current Interrupt (ALCI) to 
    prevent electric shock or fi re.
    Stop using the product if any abnormality/
    failure occurs or turn off the power switch and 
    breaker. (Risk of smoke/fi re/electric shock)
    Examples of abnormality/failure
    • The ELCB or GFCI or ALCI trip frequently.  • Burning smell is observed.• Abnormal noise or vibration of the unit is 
    observed.
    • Water leaks from the indoor unit. • Power cord becomes abnormally hot.• Fan speed cannot be controlled.• The unit stops running immediately even if it 
    is switched on for operation.
    • The fan does not stop even if the operation 
    is stopped.
    Contact your local dealer immediately for 
    maintenance or repair assistance.
    This equipment must be earthed to prevent 
    electrical shock or fi re.
    Prevent electric shock by switching off the 
    power supply:
    - Before cleaning or servicing,
    - When extended non-use, or
    - During abnormally strong lightning activity.
    CAUTION
    Indoor unit and outdoor unit
    Do not wash the indoor unit with water, 
    benzene, thinner or scouring powder to avoid 
    damage or corrosion at the unit.
    Do not use for preservation of precise 
    equipment, food, animals, plants, artwork 
    or other objects. This may cause quality 
    deterioration, etc.
    Do not use any combustible equipment 
    in front of the airfl ow outlet to avoid fi re 
    propagation.
    Do not expose plants or pet directly to airfl ow 
    to avoid injury, etc.
    Do not touch the sharp aluminium 
    fi n, sharp parts may cause injury.
    Do not switch ON the indoor unit when waxing 
    the fl oor. After waxing, aerate the room 
    properly before operating the unit.
    Do not install the unit in oily and smoky areas 
    to prevent damage to the unit.
    Do not dismantle the unit for cleaning purpose 
    to avoid injury.
    Do not step onto an unstable bench when 
    cleaning the unit to avoid injury.
    Do not place a vase or water container on the 
    unit. Water may enter the unit and degrade 
    the insulation. This may cause an electric 
    shock.
    Do not open window or door for long time 
    during COOL/DRY mode operation.
    Prevent water leakage by ensuring drainage 
    pipe is:
    - Connected properly,
    - Kept clear of gutters and containers, or
    - Not immersed in water
    After a long period of use or use with any 
    combustible equipment, aerate the room 
    regularly.
    After a long period of use, make sure the 
    installation rack does not deteriorate to 
    prevent the unit from falling down.
    Remote control
    Do not use rechargeable (Ni-Cd) batteries. It 
    may damage the remote control.
    To prevent malfunction or damage of the 
    remote control:
    • Remove the batteries if the unit is not going 
    to be used for a long period of time.
    • New batteries of the same type must be 
    inserted following the polarity stated.
    Safety precautions 
    						
    							6
    AUTO
    COMFORT
    MODE
    POWERFUL/
    QUIET
    TEMP
    OFF/ON
    TIMER
    SET
    CANCEL ON
    OFF1
    23
    AIR SWING
    FAN SPEED
    SETAC
    RC
    ECONAVI
    FAN
    SPEED
    AIR
    SWINGAUTO
    HEAT
    COOL
    DRY
    FAN
    /
    TEMP
    OFF/ON
    TIMERSET
    CANCEL
    ON
    OFF
    123
    CHECK
    Remote control display
    Human activity 
    sensor
    Remote control 
    receiver and 
    Indicator 
    Auto OFF/ON button
    Use when remote control is misplaced or a malfunction occurs. Raise the front panel:
    • To use in AUTO mode, press the button once.
    • To use in COOL mode, press and hold the button until 1 beep is heard, then 
    release.
    • To use in HEAT mode, press and hold the button until 1 beep is heard, then 
    release. And press again until 2 beeps, then release.
    • Press the button again to turn off.
    Press and hold for 
    approximately 
    10 seconds to show 
    temperature setting in 
    °F or °C.
    Press and hold for 
    approximately 
    5 seconds to show
    12-hour (am/pm) or
    24-hour time indication.
    Press to restore the 
    remote control to 
    default setting.
    Not used in normal 
    operations.
    ECONAVITo optimize energy saving
    ECONAVI
    MODETo select operation mode
    AUTO   - For your convenience
    HEAT  - To enjoy warm air
    COOL   - To enjoy cool air
    DRY  - To dehumidify the environment
    FAN  - To circulate air in the room
    POWERFUL/
    QUIETTo switch between 
    powerful & quiet
    QUIET POWERFUL
    POWERFUL: To reach temperature quickly
    POWERFUL
    Single• This operation stops automatically 
    after 20 minutes.
    Multi• Press the button again or turn OFF the 
    unit to stop this operation.
    QUIET: To enjoy quiet operation
    QUIET
    • This operation reduces airfl ow noise.
    FAN SPEEDTo select fan speed 
    (Remote control display)
    • For AUTO, the indoor fan speed is 
    automatically adjusted according to the 
    operation mode.
    How to use
    POWER
    TIMER
    ECONAVI
    AUTO COMFORT
    POWERFUL
    QUIET
    (Green)
    (Orange)
    (Green)
    (Green)
    (Orange)
    (Orange)
    SingleSingle split system
    MultiMulti split system 
    						
    							7
    English
    Note
    ECONAVI
     , 
    POWERFUL/
    QUIET
     , 
    AUTO
    COMFORT
    • Can be activated in all modes and can be 
    cancelled by pressing the respective button 
    again.
    • Cannot be selected at the same time.
    To set the timer
    2 sets of ON and OFF timers are available 
    to turn ON or OFF the unit at different preset 
    times.
    TIMERSET
    CANCEL ON
    OFF1
    23
    AC
    CCANCEL
    3
    ACC
    213
    1Select ON or OFF 
    timerExample: 
    OFF at 11:50PM
    • Each time pressed:
    OFFAMCancel
    2Set the time2PM
    3Confi rmSET
    PM
    TIMER
    • To cancel ON or OFF timer, press ON or OFF 
    to select respective 
     or  then press CANCEL.
    • If timer is cancelled manually or due to power 
    failure, you can restore the timer again by 
    pressing 
    ON or OFF to select respective  or 
     then press SET.
    • The nearest timer setting will be displayed and 
    will activate in sequence.
    • When ON Timer is set, the unit may start 
    earlier (up to 35 minutes) before the actual 
    set time in order to achieve the desired 
    temperature on time.
    • Timer operation is based on the clock set in 
    the remote control and repeats daily once set. 
    For clock setting, please refer to Quick guide.
    See To learn more... for details.
    AUTO
    COMFORTTo maximize comfort
    AUTO COMFORT
    AIR SWINGTo adjust vertical airfl ow 
    direction
    (Remote control display)
    • Keeps the room ventilated.
    • In COOL/DRY mode, if AUTO is set, the fl ap 
    swings up/down automatically.
    • In HEAT mode, if AUTO is set, the horizontal fl ap 
    is fi xed at the predetermined position.
    • Do not adjust the fl ap by hand.
    How to use
    To adjust horizontal airfl ow direction
    • Manually  adjustable.
    Auto Restart Control
    • If power is resumed after a power failure, the 
    operation will restart automatically after a 
    period of time with previous operation mode 
    and airfl ow direction. 
    • This control is not applicable when TIMER is 
    set. 
    						
    							8
    Operation mode
    AUTO : During operation mode selection the POWER indicator blinks.Single• Unit selects operation mode every 10 minutes according to setting temperature and room temperature.
    Multi• Unit selects operation mode every 3 hours according to setting temperature, outdoor temperature and room 
    temperature.
    HEAT
     : Unit takes a while to warm up. The POWER indicator blinks during this operation.
    COOL : Provides effi cient comfort cooling to suit your needs.
    DRY : Unit operates at low fan speed to give a gentle cooling operation.
    FA N : To circulate air in the room.
    ECONAVI and AUTO COMFORT
    ECONAVIAUTO
    COMFORTorNote
    AIR SWINGWhen manual AIR SWING is selected, 
    the ECONAVI and AUTO COMFORT 
    operations will be cancelled.
    The unit will start to initialize
    (for approximately 1 minute)The human activity sensor
    will start to detect.
    Human activity sensor operation
    Low activity Normal activity Human
    Mode
    Set 
    temperatureHigh activityAbsent ECONAVI 
    ; Detecting human presence and activity, the unit controls room temperature to save energy.
    Low activity Normal activity Human
    Mode
    Set 
    temperatureHigh activityAbsent
    Set 
    Fan Speed AUTO COMFORT ; Detecting human presence and activity, the unit controls room temperature to keep human 
    comfortable consistently.HEAT
    COOL/DRY
    HEAT
    COOL/DRY
    *  During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached.
    **  During human absence, maximum fan speed for COOL/DRY mode is medium fan.
    +1 tap”0HGLXP)DQ
    
    +1 tap*
    +2°F / +1°C
    +2°F / +1°C+0.5°F / +0.3°C
    -2°F / -1°C
    -4°F / -2°C+4°F /
    +2°C
    -4°F /
    -2°C -4°F / -2°C+4°F /
    +2°C
    -4°F /
    -2°C
    The human activity sensor will also scan for area of heat source and movement in a room.
    Detection area
    • The human activity sensor performance is infl uenced by indoor unit 
    location, movement speed, temperature range, etc.
    90º
    23ft/7m
    • The human activity sensor may: 
    -  mistakenly detect an object with heat source & movement similar to human, such as pets, etc. 
    -  mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
    • Do not place large objects near the sensor and keep away heating units or humidifi er from the sensor’s detection 
    area. They may cause sensor malfunction.
    To learn more...SingleSingle split system
    MultiMulti split system 
    						
    							9
    EnglishTo learn more... / Cleaning instructions
    Cleaning instructions
    To ensure optimal performance of the unit, 
    cleaning has to be carried out at regular 
    intervals. Dirty unit may cause malfunction 
    and you may see error code “H99”. Please 
    consult authorised dealer.
    • Switch off the power at the circuit breaker before 
    cleaning.
    • Do not touch the aluminium fi n, sharp parts may 
    cause injury.
    • Do not use benzene, thinner or scouring powder.
    • Use only soap (
     pH 7) or neutral household 
    detergent.
    • Do not use water hotter than 104°F / 40°C.
    Indoor unit
    Wipe the unit gently with a soft, 
    dry cloth.
    Human activity sensor
    Do not hit or violently press or poke it with a sharp 
    object. This can lead to damage and malfunction.
    Front panel
    Wash gently and dry.
    Remove the front panel
    RaisePull out
    1
    2
    POWER
    TIM
    ER
    EC
    O
    NAVI
    AUTO COMFORTPOWERFULQUIET
    Close it securely
    POWER
    TIM
    ER
    EC
    O
    NAV
    I
    AUTO COMFORTPOWERFULQUIET
    2Close down
    3Press both ends of the front panelInsert at both sides
    1
    Air fi lters
    Every 2 weeks
    • Wash/rinse  the fi lters gently 
    with water to avoid damage to 
    the fi lter surface.
    • Dry  the fi lters thoroughly under shade, away 
    from fi re or direct sunlight.
    • Replace any damaged fi lters.
    Remove air fi lter Attach air fi lter
    Insert into the unit
    Air purifying fi lter
    Vacuum the air purifying fi lter
    • It is recommended to clean the fi lter every 6 
    months.
    • Replace  the fi lter every 3 years or replace any 
    damaged fi lter. Part no.: CZ-SA20P
    For seasonal inspection after extended 
    non-use
    • 
    Checking of remote control batteries.• No obstruction at air inlet and air outlet vents.• Use Auto OFF/ON button to select COOL/
    HEAT operation. After 15 minutes of operation, 
    it is normal to have the following temperature 
    difference between air inlet and air outlet vents:
     
    COOL: ≥14.4°F/8°C  HEAT: ≥25.2°F/14°C
    For extended non-use
    • Activate HEAT mode for 2~3 hours to remove 
    moisture left in the internal parts thoroughly to 
    prevent mould growth.
    • Turn off the power supply.• Remove the remote control batteries.
    Indoor unit
    POWER
    TIM
    ER
    EC
    O
    NAV
    I
    AUTO COMFORTPOWERFULQUIET
    Aluminium fi n Front panel
    Air fi lters
    Human activity 
    sensor
    Air purifying fi lter 
    						
    							10
    The following symptoms do not indicate malfunction.
    SymptomCause
    Mist emerges from indoor unit. • Condensation effect due to cooling process.
    Water fl owing sound during operation. • Refrigerant fl ow inside the unit.
    The room has a peculiar odour. • This may be due to damp smell emitted by the wall, 
    carpet, furniture or clothing.
    Indoor fan stops occasionally during automatic 
    fan speed setting.• This helps to remove the surrounding odour.
    Airfl ow continues even after operation has 
    stopped.• Extraction of remaining heat from the indoor unit
    (maximum 30 seconds).
    Operation is delayed a few minutes after 
    restarting.• The delay is a protection to the unit’s compressor.
    Outdoor unit emits water/steam. • Condensation or evaporation occurs on pipes.
    TIMER indicator is always on. • The timer setting repeats daily once set.
    POWER indicator blinks during HEAT mode 
    with no warm air supply (and fl ap is closed).• The unit is in defrost mode (and AIR SWING is set to 
    AUTO).
    Indoor fan stops occasionally during heating 
    operation.• To avoid unintended cooling effect.
    POWER indicator blinks before the unit is 
    switched on.• This is a preliminary step in preparation for the 
    operation when the ON timer has been set.
    Cracking sound during operation. • Changes of temperature caused the expansion/
    contraction of the unit.
    Discoloration of some plastic parts. • Discoloration is subject to material types used in plastic 
    parts, accelerated when exposed to heat, sun light, UV 
    light, or environmental factor.
    Check the following before calling for servicing.
    SymptomCheck
    Operation in HEAT/COOL mode is not working 
    effi ciently.• Set the temperature correctly.
    • Close all doors and windows.
    • Clean or replace the fi lters.
    • 
    Clear any obstruction at the air inlet and air outlet vents.
    Noisy during operation. • Check if the unit has been installed at an incline.
    • Close the front panel properly.
    Remote control does not work.
    (Display is dim or transmission signal is weak.)• Insert the batteries correctly.
    • Replace weak batteries.
    The unit does not work. • Check if the circuit breaker is tripped.
    • Check if timers have been set.
    The unit does not receive the signal from the 
    remote control.• Make sure the receiver is not obstructed.
    • Certain fl uorescent lights may interfere with signal 
    transmitter. Please consult authorised dealer.
    Troubleshooting
    NON SERVICEABLE CRITERIASSWITCH OFF POWER AT THE CIRCUIT BREAKER then please consult an authorised dealer under 
    the following conditions:
    • Abnormal noise during operation.
    • Water/foreign particles have entered the remote 
    control.
    • Water leaks from Indoor unit.• Circuit breaker switches off frequently.
    • Switches or buttons are not functioning properly. 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Cs Me5 7rkua Operating Instructions Manual