Page 31
Indoor Unit : CS-KS18NB4UW & CZ-18BT1U Outdoor Unit : CU-KS18NKU or CU-KS18NKUA Power Supply : 230V Single Phase 60Hz < Cooling Capacity > 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB : Outdoor Ambient Temp. 95 °F (35 °C) DB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary...
Page 32
5-3. Cooling Capacity (Low Ambient) Indoor Unit : CS-KS12NB41 & CZ-18BT1U Outdoor Unit : CU-KS12NK1A Power Supply : 115V Single Phase 60Hz < Cooling Capacity (Low Ambient) > TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) 1. 2. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling...
Page 33
Indoor Unit : CS-KS18NB4UW & CZ-18BT1U Outdoor Unit : CU-KS18NKUA Power Supply : 230V Single Phase 60Hz < Cooling Capacity (Low Ambient) > RATING CAPACITY: 17,500 BTU/h AIR FLOW RATE: 341 CFM INDOOR OUTDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) WB DB 0 5 15 25 35 45 55 (-17.8) (-15.0) (-9.4) (-3.9) (1.7) (7.2) (12.8) TC 13,400 13,430 13,440 13,470 13,500 13,520 13,510 CI 0.690.730.760.66 0.660.660.70 72 (22.2) SHC 9,740 9,740 9,740 11,860 9,740 9,800 9,800 59 76 (24.4) SHC...
Page 34
6. ELECTRICAL DATA 6-1. Electrical Characteristics Indoor Unit CS-KS12NB41 & CZ-18BT1U Outdoor Unit CU-KS12NK1A Indoor Unit Outdoor Unit Complete Unit Fan Motor Fan Motor + Compressor Performance at 115V Single-phase 60Hz Rating conditions Running amp. 0.21 Power input 1812.39 1,242 Cooling 12.6 1,260 Rating conditions: Indoor air temperature: 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB Outdoor air temperature: 95 °F (35 °C) DBA W 34
Page 35
Indoor Unit CS-KS18NB4UW & CZ-18BT1U Outdoor Unit CU-KS18NKU Indoor Unit Outdoor Unit Fan Motor Fan Motor + Compressor Performance at 230V Single-phase 60Hz Rating conditions Running amp. A 0.15 Power input W A W A W A W228.15 1,838 Rating conditions: Indoor air temperature: 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB Outdoor air temperature: 95 °F (35 °C) DB Cooling 8.3 1,860 Indoor Unit Outdoor Unit Fan Motor Fan Motor + Compressor Performance at 208V Single-phase 60Hz Rating conditions Running...
Page 36
6-2. Electric Wiring Diagrams Indoor Unit CS-KS12NB41 & CZ-18BT1U CS-KS18NB4UW & CZ-18BT1U 8FA2-5250-46900-2 123456 123456 FMDP FAN MOTORDRAIN PUMP DCM 6P (BLU) 6P (WHT)DP 3P (BLU) 3P (RED)PWM/POW 7P (RED) PWM/POW 7P (RED) RC 4P (WHT)IND 7P (WHT)FS 3P (RED) FLAP 5P (WHT)ROOM 2P (YEL)COIL-1 2P (RED) IND LAMP ASSYFLAP (W) FLOAT SWITCH BOX BOX SERIAL 2P (WHT)SERIAL 2P (WHT) TERMINAL BASE CONTROLLER CONTROLLER TO OUTDOOR UNIT GNDFERRITE COREAC1 AC2 SI1 RED YELBLU 11YEL/(RED)33 112 1122 1122 23344556677...
Page 38
Outdoor Unit CU-KS18NKU CU-KS18NKUA 8FA2-5251-12000-2 25A CONTROLLER DCFM MV0 FAN MOTOR 1 234567 BLKWHTREDBLUYEL BLKWHTREDBLUYEL w w w w w w ww 12345512431212 12345671245673 12 1234 3455 12 1233 12 12 1234124312341243 21 2 1 FERRITE CORE COMPRESSOR THERMISTOR OUT DOOR THERMISTOR COIL THERMISTOR MV0 MAGNETIC COIL w w *ELEC SYSTEM ASSY 1 2 3 4 5 6 REACTANCE WHT2P-CONNECTOR (WHT) WHTWHT WHT REDRED(PINK) RED(PINK) WHT WHT WHT WHTWHT WHT BLU BLU U V W BLKBLKBLKBLKYELYELORGYELGRYBLKRED COMP...
Page 39
ACL (Reset) button 1HR. TIMER button ON/OFF operation button HIGH POWER button Test run mode Self-diagnostic mode Address setting mode Fig. 1 Fig. 2 Fig. 3 Ta b ACL button 7. MAINTENANCE 7-1. Address Setting of the Remote Controller The address can be set in order to prevent interference between remote controllers when two indoor units are installed near each other. The address is normally set to "A." To set a different address, it is necessary to change the address on the second remote...
Page 40
One of the two types of connectors illustrated at left is used. Their basic structure is the same for each. How to Disconnect Hold the resin connector cover, and pull the connector off. You cannot disconnect the connector by pulling the wire since it is locked inside. Always hold the cover to disconnect. (See illustration at left.) For the connector without the resin cover, push the lock in the direction of "2" while pulling it off. How to Connect In order to connect, hold the resin cover of...