Page 11

10
4.  Night Setback Mode
Night Setback Mode is used for saving energy.
Press the NIGHT SETBACK button while unit is operating. (except 
FAN mode)
The   mark appears in the display.
To release the night setback function, press the NIGHT SETBACK 
button again.
Pressing the MODE selector button cancels Night Setback mode.
In Cooling and DRY Mode: ( and  )
5.  QUIET Mode
QUIET Mode is used to reduce the fan sound of the indoor unit. 
Press the QUIET button.
The   mark appears in the display.
To cancel,...

Page 12

11
7.  UNOCCUPIED Mode
Unoccupied mode is used to prevent the room temperature from  
increasing too much when no one is in the room, and operate 
automatically to save energy.
Press the UNOCCUPIED button.
The   mark appears in the display. 
To release the unoccupied function, press the UNOCCUPIED button 
again.
Unoccupied Indication
Even if Unoccupied Mode is ON, it will be disabled if the air 
conditioner is in operation.
• Unoccupied Function can be set and released through all 
operational modes,...

Page 13

12
SPECIAL REMARKS
How it works?
• Once the room temperature reaches the level that was set, the 
unit’s operation frequency is changed automatically.
• During DRY operation, the fan speed automatically runs at lower 
speed for providing a comfortable breeze.
• ‘‘DRY’’ operation is not possible if the indoor temperature is 59 °F 
or less.
• Sometimes the indoor unit may not get to the set fan speed such as 
LOW under cool operation at very low outdoor temperatures due to 
the indoor unit being protected...

Page 14

13
2.  How to set the OFF time
(Example) To stop the air conditioner at 11:00 am.
3. How to set the ON time
(Example) To start operation at 7:10 am.
4. How to set daily ON/OFF repeat timer
(Example) To start operation at 7:10 am. and stop the air conditioner 
at 11:00 am.
• The ON/OFF combination timer uses the current time as the 
reference, and it is activated starting from whichever set time 
comes first.
• With the ON/OFF combination timer, the settings are repeated 
ever y day.
• You can check the...

Page 15

14
USING THE 1-HOUR OFF 
TIMER
1. 1-Hour OFF Timer
This function causes the unit to operate for one hour and then 
stop, regardless of whether the unit is on or off when this 
button is pressed.
The   indicator in the display indicates that this function is 
operating.
Setting procedure:
Regardless of whether the unit is operating or stopped, press the 1 
HR. TIMER button.
 appears in the display.
Cancellation procedure:
Press the ON/OFF operation button to turn the unit off, wait for the 
unit to stop...

Page 16

15
• Use the FLAP button on the remote controller to adjust the 
position of the flap. If you move the flap by hand, the flap 
position according to the remote controller and the actual 
flap position may no longer match. If this should happen, 
shut off the unit, wait for the flap to close, and then turn on 
the unit again; the flap position will now be normal again.
• Do not have the flap pointed down during cooling operation. 
Condensation may begin to form around the air vent and drip 
down....

Page 17

16
Cleaning the main unit and Remote Controller
• Wipe clean using a soft, dry cloth.
• To remove stubborn dirt, moisten a cloth in warm water no hotter 
than 104 °F, wring thoroughly, and then wipe.
• The front panel can be removed in order to wash it with water.
Removing and remounting the front panel
Removing
Open the front panel until it is nearly horizontal, grasp the sections 
near the front panel arms on both sides, and then remove the panel 
by pushing the arms towards the outside while pulling...

Page 18

17
OPERATING RANGE
The air conditioner is operable within the temperature ranges as 
listed below:
WIRED REMOTE CONTROLLER
A separately sold wired remote controller (CZ-RD515U) 
used with this air conditioner is also available. If you wish 
to use the wired remote control function, you will need to 
purchase both the optional wired remote controller and its 
connection kit (CZ-RC515UA).
Temperature Indoor air 
temperature Outdoor air 
temperature
COOLING Max.  95 °F DB / 
71 °F WB 115 °F DB
Min.  67 °F...

Page 19

18
SPECIFICATIONS
Model No.Outdoor Unit  Indoor Unit
CS-KS30NKU CU-KS30NKUA 
30,600 [ 10,900 ~ 30,600 ]
55Single-phase, 208-230 V, 60 Hz
9.00 [ 3.20 ~ 9.00 ]
-
-
-
-
-
35-13/16×37-1/32×13-3/8
(910×940×340)
-
49/44/39
-
-
Heating Capacity
Operation
Sound
Unit Dimensions (H×W×D)
(Indoor unit : Include panel)
Net Weight Power Source
Cooling CapacitykW
BTU/h
kW
BTU/h
inch(mm)
lbs.(kg)
Cooling
OperationOutdoor (Hi)
Indoor(H/M/L)
Outdoor (Hi)
Indoor(H/M/L)
Heating
Operation
dB(A)
dB(A)...