Panasonic Cs C9gkzw Cs C12gkzw Cu C9gkzw Cu C12gkzw Repair Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Cs C9gkzw Cs C12gkzw Cu C9gkzw Cu C12gkzw Repair Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							11
    5 Dimensions
    5.1. Indoor Unit & Remote Control
    5.1.1. CS-C9GK CS-C12GK 
    						
    							12
    5.2. Outdoor Unit
    5.2.1. CU-C9GK
    5.2.2. CU-C12GK 
    						
    							13
    6 Refrigeration Cycle Diagram 
    						
    							15
    8 Wiring Connection Diagram
    8.1. CS-C9GK CU-C9GK / CS-C12GK CU-C12GK
    Resistance of Indoor Fan Motor Windings
    Note: Resistance at 25°C of ambient temperature.
    Resistance of Outdoor Fan Motor Windings
    Note: Resistance at 25°C of ambient temperature.Resistance of Compressor Windings
    Note: Resistance at 20°C of ambient temperature.
    Note: Resistance at 20°C of ambient temperature.
    MODEL CS-C9GK CS-C12GK
    CONNECTION CWA921181J CWA921324
    BLUE-YELLOW 390.0 Ω371.0 Ω
    YELLOW-RED 394.0 Ω385.6 Ω
    MODEL CU-C9GK CU-C12GK
    CONNECTION CWA951391J CWA951120J
    BLUE-YELLOW 365 Ω200.4 Ω
    YELLOW-RED 559 Ω252.5 ΩMODEL CU-C9GK
    CONNECTION 2PS146D3BA04
    C - R 4.232 Ω
    C - S 3.790 Ω
    MODEL CU-C12GK
    CONNECTION 2KS206D5AF04
    C - R 2.234 Ω
    C - S 2.630 Ω 
    						
    							16
    9 Electronic Circuit Diagram 
    						
    							17
    10 Printed Circuit Board
    10.1. Indoor Unit
    TOP VIEW 
    						
    							19
    10.2. Indicator
    TOP VIEW
    BOTTOM VIEW 
    						
    							20
    11 Installation Instruction
    11.1. Select The Best Location
    • There should not be any heat source or steam near the unit.
    • There should not be any obstacles blocking the air
    circulation.
    • A place where air circulation in the room is good.
    • A place where drainage can be easily done.
    • A place where noise prevention is taken into consideration.
    • Do not install the unit near the door way.
    • Ensure the spaces indicated by arrows from the wall, ceiling,
    fence or other obstacles.
    • Recommended installation height for indoor unit shall be at
    least 2.5 m.
    • If an awning is built over the unit to prevent direct sunlight or
    rain, be careful that heat radiation from the condenser is not
    obstructed.
    • There should not be any animal or plant which could be
    affected by hot air discharged.
    • Keep the spaces indicated by arrows from wall, ceiling,
    fence or other obstacles.
    • Do not place any obstacles which may cause a short circuit
    of the discharged air.
    • If piping length is over the rated length, additional refrigerant
    should be added as shown in the table.
    • This illustration is for explanation purposes only.
    The indoor unit will actually face a different way.
    Indoor Unit
    Outdoor Unit
    Piping size Rated
    Length
    (m)Max
    Elevation
    (m)Max.
    Piping
    Length
    (m)Additional
    Refrigerant
    (g/m) Model Gas Liquid
    CU-C9GKZ 3/8” 1/4” 7.5 5 10 10
    CU-C12GKZ 1/2” 1/4” 7.5 5 15 10Indoor/Outdoor Unit Installation Diagram 
    						
    All Panasonic manuals Comments (0)