Home > Panasonic > Air Conditioner > Panasonic Cs C9dkzw Cu 2c18dkh Cu 3c20dkh Repair Manual

Panasonic Cs C9dkzw Cu 2c18dkh Cu 3c20dkh Repair Manual

Here you can view all the pages of manual Panasonic Cs C9dkzw Cu 2c18dkh Cu 3c20dkh Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.

Page 1

 1 Features 2
 2 Functions 
3
 3 Product Specifications 
6
 3.1. CS-C9DKZWCU-2C18DKH 
6
 3.2. CS-C9DKZWCU-3C20DKH 
8
 4 Dimensions 
10
 4.1. Indoor Unit & Remote Control 
10
 4.2. Outdoor Unit 
11
 5 Refrigeration Cycle Diagram 
12
 6 Block Diagram 
13
 7 Wiring Diagram 
15
 8 Operation Details 
17
© 2004 Panasonic HA Air-Conditioning (M) Sdn Bhd
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
CS-C9DKZW CU-2C18DKH
CS-C9DKZW CU-3C20DKH
 8.1. Cooling Operation...

Page 2

 8.12. Timer Control 29
 8.13. Random Auto Restart Control 
29
 8.14. Remote Control Signal Receiving Sound  
29
 9 Operating Instructions 
30
 10  Installation Instructions 
36
 10.1. Safety Precautions 
36
 10.2. Attached accessories 
38
 10.3. Select the best location 
38
 10.4. Indoor/Outdoor Unit Installation Diagram 
38
 10.5. Indoor unit 
39
 10.6. Outdoor unit 
43
 11  3-way Valve 
47
 11.1. Air purging 
48
 11.2. Pumping down 
49
 11.3. Evacuation 
52
 11.4. Gas charging 
53
 12...

Page 3

2 Functions
   
 
3
CS-C9DKZW CU-2C18DKH / CS-C9DKZW CU-3C20DKH 

Page 4

 
 
 
  
 
 
 
 
 
4
CS-C9DKZW CU-2C18DKH / CS-C9DKZW CU-3C20DKH 

Page 5

Outdoor Unit
• To protect compressor from reverse
rotation when there is a instantaneous
power failure.
60 Sec. Forced Operation Control
• Once the compressor is activated, it
does not stop within the first 60 sec.
However, it stops immediately when
received stop signal from remote control.
Overload Protector
• 2-stage OLP to protect the compressor.
Overload Protector will trip when
– Temperature of compressor increases
to 120°C.
– High temperature or high current flows
to compressor.
(Refer circuit...

Page 6

3 Product Specifications
3.1. CS-C9DKZW CU-2C18DKH
UnitIndoor unitOutdoor unit
Power Source (Phase, Voltage, Cycle)
ø, V, Hz
Single
240 - 220
50
Cooling CapacitykW
(BTU/h)(1 unit)2.44 - 2.40
(8,320 - 8,180)(2 units)4.88 - 4.80
(16,600 - 16,400)
kJ/h(1 unit)8,640(2 units)8,780
Moisture Removall/h
(Pint/h)(1 unit)1.5
(3.2)(2 units)2.6
(5.5)
Airflow MethodOUTLET
INTAKE
SIDE VIEWTOP VIEW
Air VolumeLom3/min (cfm)5.6 (200) - 5.6 (200)—
Mem3/min (cfm)6.8 (240) - 6.8 (240)—
Him3/min (cfm)8.6 (300) - 8.6...

Page 7

UnitIndoor unitOutdoor unit
Fan MotorDescriptionCross-flow FanPropeller Fan
MaterialAS + Glass Fiber 20%AS + Glass Fiber 20%
TypeInduction (4-poles)Induction (6-poles)
InputW29.3 - 26.3134.6 - 118.8
Rated OutputW1550
Fan SpeedLowrpm750 - 750—
Mediumrpm920 - 920—
Highrpm1,160 - 1,160760 - 720
SuperHighrpm1,250 - 1,250—
Heat ExchangerDescriptionEvaporatorCondenser
Tube materialCopperCopper
Fin materialAluminiumAluminium (Blue Coat)
Fin TypeSlit FinLouver Fin
Row / Stage(Plate fin configuration, forced...

Page 8

3.2. CS-C9DKZW CU-3C20DKH
Indoor unitOutdoor unit
UnitSingle Operation
(A, B1, B2)Single OperationDouble OperationTriple Operation
(A)(B1 or B2)(B1 + B2)(A + B1 or B2)(A + B1 + B2)
Power Source
(Phase, Voltage, Cycle)
ø, V, Hz
Single
240 - 220
50
Cooling Capacity Per UnitkW
(BTU/h)—2.40-2.34
(8,180-7,980)2.82-2.78
(9,620-9,480)3.60-3.52
(12,300-12,000)5.22-5.12
(17,800-17,500)6.00-5.86
(20,500-20,000)
Moisture Removall/h
(Pint/h)—1.5
(3.2)1.6
(3.4)2.1
(4.4)2.8
(5.9)3.2
(6.8)
Airflow MethodOUTLET
INTAKE...

Page 9

Indoor unitOutdoor unit
Fan MotorDescriptionCross-flow FanPropeller Fan
MaterialAS + Glass Fiber
20%AS + Glass Fiber 20%
TypeInduction (4-poles)Induction (6-poles)
InputW29.3 - 26.3134.0 - 118.7
RatedOutputW1550
Fan
SpeedLowrpm750 - 750—
Mediumrpm920 - 920—
Highrpm1,160 - 1,160765 - 725
SuperHighrpm1,250 - 1,250—
Heat
ExchangerDescriptionEvaporatorCondenser
Tube materialCopperCopper
Fin materialAluminiumAluminium (Blue Coat)
Fin TypeSlit FinLouver Fin
Row / Stage(Plate fin configuration, forced draft)...

Page 10

4 Dimensions
4.1. Indoor Unit & Remote Control
10
CS-C9DKZW CU-2C18DKH / CS-C9DKZW CU-3C20DKH 
Start reading Panasonic Cs C9dkzw Cu 2c18dkh Cu 3c20dkh Repair Manual

Related Manuals for Panasonic Cs C9dkzw Cu 2c18dkh Cu 3c20dkh Repair Manual

All Panasonic manuals