Home > Panasonic > Air Conditioner > Panasonic Cs A7gkd Cs A9gkd Cs A12gkd Series Repair Manual

Panasonic Cs A7gkd Cs A9gkd Cs A12gkd Series Repair Manual

Here you can view all the pages of manual Panasonic Cs A7gkd Cs A9gkd Cs A12gkd Series Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.

Page 1

© 2006 Panasonic HA Air-Conditioning (M) Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying and
distribution is a violation of law.
Order No. MAC0611059C8
Air Conditioner
CS-A7GKD CU-A7GKD
CS-A9GKD CU-A9GKD
CS-A12GKD CU-A12GKD
TABLE OF CONTENTS
PA G E PA G E
1 Safety Precautions-----------------------------------------------2
2 Specifications-----------------------------------------------------4
2.1. CS-A7GKD CU-A7GKD---------------------------------- 4
2.2. CS-A9GKD...

Page 2

2 9 Printed Circuit Board------------------------------------------20
9.1. Indoor Unit (Main Printed Circuit Board) ----------- 20
9.2. Indoor Unit (Power Printed Circuit Board) --------- 22
9.3. Indicator ---------------------------------------------------- 23
10 Installation Instruction----------------------------------------24
10.1. Select The Best Location ------------------------------ 24
10.2. Indoor Unit ------------------------------------------------- 25
10.3. Outdoor Unit...

Page 3

3
8.When conne cting the piping,  do n ot allow  air or  any s ubstances ot her than  the  specified refrigerant to  enter the  refrigeration  cyc le.
Ot he
rwise, this may lower t he cap acity, cause abnorma lly high pr essure in  the refriger ation cycle, and p ossibly result in explosion and
inju
ry.
 9
. It is desir able that the amount of  resid ual oil is less than 40 mg/10m.
10.Do not  modify  the length  of the  power supply  cord or use of the  exte nsion cor d, and  do n ot share  the single...

Page 4

4
2 Specifications
2.1. CS-A7GKD CU-A7GKD
ItemUnit Indoor unit Outdoor unit
Performance Test Condition JIS
C Capacity kW 2.00 - 2.00
O BTU/h 6820 - 6820
O kcal/h 1720 - 1720
L EER W/W 3.28 - 3.17
I BTU/hW 11.2 - 10.8
N Noise Level dB (A) High: 33 Low: 26 High: 46 - 47
G Power level dB High: 46 High: 61 - 62
H Capacity kW 2.10 - 2.10
E BTU/h 7160 - 7160
A kcal/h 1810 - 1810
T Cop W/W 4.20 - 4.00
I BTU/hW 14.3 - 13.6
N Noise Level dB (A) High: 36 Low: 28 High: 48 - 49
G Power level dB High: 49 High: 64 -...

Page 5

5 1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
Note:
• Specification are subjected to change without prior notice for further improvement.
 Item Unit
Power Source (Phase, Voltage, Cycle) ø Single Single
V 220...

Page 6

6
2.2. CS-A9GKD CU-A9GKD
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
ItemUnit Indoor unit Outdoor unit
Performance Test Condition JIS
C Capacity kW 2.65 - 2.65
O BTU/h 9040 - 9040
O kcal/h 2280 - 2280
L EER W/W...

Page 7

7 Note:
• Specification are subjected to change without prior notice for further improvement.
 Item Unit
Power Source (Phase, Voltage, Cycle) ø Single Single
V 220 230
Hz 50 50
Input power Cooling W 830 860
Heating W 700 740
Starting Current A 18 18
Running Current Cooling A 3.9 3.9
Heating A 3.3 3.3
Power Factor Cooling % 97 96
Heating % 96 97
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord Number of core 3 (1.5mm)
Length m (ft) 2 (6)
Thermostat——...

Page 8

8
2.3. CS-A12GKD CU-A12GKD
1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F
D.B.), 6°C W.B. (42.8°F W.B.)
ItemUnit Indoor unit Outdoor unit
Performance Test Condition JIS
C Capacity kW 3.52 - 3.54
O BTU/h 12000 - 12100
O kcal/h 3030 - 3040
L EER...

Page 9

9 Note:
• Specification are subjected to change without prior notice for further improvement.
 Item Unit
Power Source (Phase, Voltage, Cycle) ø Single Single
V 220 230
Hz 50 50
Input power Cooling kW 1.08 1.12
Heating kW 1.09 1.12
Starting Current A 27 27
Running Current Cooling A 5.1 5.1
Heating A 5.2 5.1
Power Factor Cooling % 96 95
Heating % 95 95
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord Number of core 3 (1.5mm)
Length m (ft) 2 (6)
Thermostat——...

Page 10

10
3Features
• High Efficiency
• Compact Design
• Wider range of horizontal discharge air
• Air Filter with function to reduce dust and smoke
• Automatic air swing and manual adjusted by Remote
Control for vertical airflow
•Long Installation Piping
-CS/CU-A7GK, CS/CU-A9GK, long piping up to 10 meter
-CS/CU-A12GK, long piping up to 15 meter
• e-ion Air Purifying System with Patrol Sensor
- Discharged Active e-ions capture dust particles and
bring it back with a boomerang-like mechanism
•Quality...