    Have a look at the manual Panasonic Convertible Camera Aw E800 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							-29-
    MENU ITEM SETTING
    • Each of the four use modes of the camera has a
    main menu.  (Shown at right)
    • Each item of the main menu has a submenu, which
    consists of several settings.
    • These settings have been preset to the optimum
    values to suit each use mode, and can be changed
    to suit actual shooting conditions.
    • They can be set from the camera and RCU (RCB).
    They can also be set from the hybrid control panel
    using the switches, but the setting items are limited
    because the menu is not shown.
    Notes:
    • Composite signals are output from the video
    output regardless of the position ENC/VF of the
    RCU (RCB) user set switch.
    • [End] is displayed only in setting from the cam-
    era alone.
    • [Option Card Set] is shown only when an
    optional card is inserted.
    MAIN MENU SCREEN
    MENU ITEM SETTING
    **Halogen Mode Set**
     Brightness Set
     Color Set
     G/L, Color Bar Set
     Sharpness(DTL) Set
     Other Set
     Option Card Set
     Initialize Data
     EndUse Mode
    Blinking
    **User Mode Set**
     Iris, Shutter, Gain Set
     Color Set
     G/L, Color Bar Set
     Detail Set1 Detail Set2
     Color Matrix Set
     Other Set1  Other Set2
     Option Card Set
     Initialize Data
     End
    Main Menu of Halogen,
    Fluorescent, Outdoor Mode
    Main Menu of User Mode 
    						
    							-30-
    SETTING
    1. From the camera alone:
    Keep the MENU switch depressed for 5 sec-
    onds or more.
    From RCU (RCB):
    Set the user set switch in the pocket to the ON
    position.
    The main menu appears on the monitor screen.
    2. Each time the MENU switch (M), ITEM/AWC switch
    (
    						
    							-31-
    • Settings enclosed in parentheses can be set with the RCU (RCB) switch or VR in RCU (RCB) mode.
    • To return to the initial settings, refer to page 46.
    SUB MENU (Halogen Mode, Fluorescent Mode, Outdoor Mode)
    **Brightness Set**
     Picture Level          ±0
     Light PEAK/AVG          0
     Light Area        Top cut
     Auto ND(ELC)        (OFF)
     Auto Gain Up        (OFF)
     Manu Gain Up (0dB)
     Pedestal             (±0)
     Contrast(Gamma)      MID
    Return**G/L,@Color Bar Set**
     H Phase              (±0)
     SC Coarse (1)
     SC Fine (±0)
     Color Bar Set    (7.5IRE)
     
    Return**Other Set**
     Shutter Speed      (OFF)
      Synchro Scan        ---
     V Resolution Normal
     Baud Rate        9600bps
     Nega/Posi           Posi
     Aspect Ratio        16:9
     Fan                   ON
    Return
    **Color Set**
     Chroma Level          ±0
     Flesh Tone            ±0
     White Bal        (AWC A)
     Highlight Chroma     OFF
     
    Return**Sharpness (DTL) Set**
     DTL Select        Normal
      Level            (HIGH)
     Noise Suppress       OFF
     Flesh Noise Suppress OFF
    Return
    q
    w
    e
    r
    t
    y
    u
    i
    o
    !0
    !1
    !2!3
    !4
    !5
    !6
    !7
    !8
    !9
    @0@1
    @2
    @3
    @4
    @5
    @6
    @7 
    						
    							• ON is automatically selected when the electronic
    shutter @1 on the submenu [Other Set] is set to
    [Auto ND]. OFF is selected when other than [Auto
    ND] is selected.
    • ON is selected when the SHUTTER switch is set
    to [ELC] in RCU (RCB) mode, and OFF is select-
    ed when it is set to other than [ELC].
    -32-
    Setting and Changing of the
    Setting (Halogen Mode, Fluores-
    cent Mode, Outdoor Mode)
    qVideo Level Adjustment
    [Picture Level: –50 - +50]
    Convergence level of AUTO IRIS/AUTO GAIN UP/
    AUTO ND (ELC) can be adjusted.
    wDetecting Ratio Adjustment [Light PEAK/AVG:
    P50 - A50]
    The ratio of AUTO IRIS/AUTO GAIN UP/AUTO ND
    (ELC) detected peak to average can be adjusted
    within a predetermined range.
    ePhotometric Measurement Method Setting [Light
    Area: All, Center, Top cut, BTM cut, R/L cut
    A photometric measurement method can be select-
    ed for AUTO IRIS/AUTO GAIN UP/AUTO ND (ELC).
    All:All the screen area is measured.
    Center:The screen is measured mainly in the cen-
    ter area, about one-third of both the top and bot-
    tom and one-third of both the right and left por-
    tions of the screen are excluded from measure-
    ment.
    Top cut:About one-third of the top part of the
    screen is excluded from measurement.
    BTM cut:About one-third of the bottom portion of
    the screen is excluded from measurement.rAuto ND (ELC) Setting [Auto ND (ELC): ON/OFF]
    ON:The electronic shutter is controlled to automati-
    cally adjust the luminance.
    OFF:Luminance is not automatically adjusted by
    the electronic shutter.
    All Center Top cut BTM cut R/L cut
    SHUTTER Switch
    RCU (RCB) R/L cut:About one-third of both the right and left
    portions of the screen are excluded from mea-
    surement.
    Notes
    RB
    RB PED
    TOTAL
    PEDA
    BATW
    AWC
    AUTOHOLD
    ABC
    IRISMAN
    AUTO1000
    S/S
    ELC 500
    100
    OFFSHUTTER SCENE21
    3 USER
    SET
    AUTO/ATWPAINTINGGAIN 
    						
    							• Only 0 dB, 9 dB, or 18 dB can be selected in
    case of using the RCU (RCB).
    • 0 dB when the manual GAIN switch on the hybrid
    control panel is at LOW, 9 dB when it is at MID, or
    18 dB when it is at HIGH.
    • In case of settings on the camera alone or when
    the iris switch on the RCU (RCB) is at [AUTO], the
    Auto Gain Up control may not operate if the lens
    iris switch is in the manual position.
    • When the AGC switch on the hybrid control panel
    is set to AGC, the Auto Gain Up control operates
    in the HIGH position.
    POWEROPERATE
    BAR
    CAMMODEGAIN AWC
    SCENE
    FILEABC
    AT W
    A
    B
    AUTO/AIW
    ELC LOW MID
    MANUON SC H
    OFF HIGH AGC
    OFF 1 / 100SHUTTERON
    OFF
    1 .
    2 .
    3 .
    4 .
    G/L PHASE
    T.PEDCABLE COMP 90°   180°
    0°        270°
    YC
    -33- tAuto Gain Up Control Setting [Auto Gain Up:
    OFF/LOW/HIGH]
    LOW:The Auto Gain Up control with a maximum
    gain increase of about 18 dB adjust the lumi-
    nance automatically.
    HIGH:The Auto Gain Up control with a maximum
    gain increase of about 30 dB operates.  If the
    luminance is still insufficient, the Night Eye also
    operates to adjust the luminance automatically.
    OFF:No auto gain up takes place.  (Gain can be
    increased manually.)
    Hybrid Control Panel
    AGC Switch
    yManual Gain Up Control Setting [Manu Gain Up:
    0 dB - 30 dB / N/Eye]
    Manual setting is possible only when the Auto Gain
    Up control is in the OFF position.
    0 dB:0 dB should be selected in normal cases.
    1 dB - 30 dB:Use this range if sufficient video out-
    put cannot be obtained even when the lens iris
    is opened in shooting dark scenes.
    N/Eye (Night Eye) :Use this mode if sufficient video
    output cannot be obtained even if 30 dB gain up
    should be selected.
    Hybrid Control Panel
    Manual GAIN Switch
    Notes
    POWEROPERATE
    BAR
    CAMMODEGAIN AWC
    SCENE
    FILEABC
    AT W
    A
    B
    AUTO/AIW
    ELC LOW MID
    MANUON SC H
    OFF HIGH AGC
    OFF 1 / 100SHUTTERON
    OFF
    1 .
    2 .
    3 .
    4 .
    G/L PHASE
    T.PEDCABLE COMP 90°   180°
    0°        270°
    YC
    Notes 
    						
    							-34-
    uBlack Level Setting [Pedestal: –30 - +30]
    The black level (pedestal) of the luminance (Y) sig-
    nal can be set.  Used in adjusting the black levels
    of two or more cameras.
    iContrast Adjustment [Contrast (Gamma):
    LOW/MID/HIGH]
    Contrast can be adjusted to any of three levels.
    oChroma Level Adjustment
    [Chroma Level: –3 - +3]
    Chroma Level can be decreased or increased to
    any of three levels each.
    !0Skin Color Adjustment [Flesh Tone: –3 - +3]
    Skin color can be decreased or increased to any of
    three levels each.
    !1White Balance Setting [White Bal: ATW/AWC A/
    AWC B/P SET 3 200K/P SET 5 600K]
    ATW:The white balance is automatically adjusted
    to be always right.
    AWC A, AWC B:Once the white balance is adjust-
    ed with the ITEM/AWC switch on the back of the
    camera, it is no longer necessary to set the
    white balance again if you simply select AWC A
    or AWC B, provided that the camera is used
    under the same conditions.Fine color adjustment can be made after setting
    AWC by red/blue gain adjustment in user mode
    or from the RCU (RCB).
    P SET 3 200K:The  white  balance  is adjusted to
    3 200K illumination.
    P SET 5 600K:The white balance is adjusted to
    5 600K illumination.
    !2Highlight Chroma Setting [Highlight Chroma:
    OFF/LOW/HIGH]
    At LOW or HIGH, the color dynamic range widens
    to prevent highlighted white portions from suppres-
    sion.
    !3Horizontal Phase Adjustment
    [H Phase: –206 - +49]
    Horizontal phase can be adjusted when a genlock
    signal is supplied. Neither P SET 3 200K nor P SET 5 600K can be set
    from the RCU (RCB) or the hybrid control panel.
    Note 
    						
    							-35-
    IRISMAN
    AUTO1000
    S/S
    ELC 500
    120
    OFFSHUTTER SCENE21
    3 USER
    SET
    OFFON
    +18
    +9
    0(dB)+6
    OFF
    −6(dB)
    GAIN
    BAR
    CAMHIGH
    LOW
    OFFRCBDTLAGC
    RB
    RB PED
    TOTAL
    PEDA
    BATW
    AWC
    AUTO
    HOLD
    ABC
    AUTO/ATWPAINTINGGAIN
    RCU (RCB)
    DTL Switch
    !8Detail Level Setting [Level: OFF/LOW/HIGH]
    Detail level can be adjusted when Detail Select set-
    ting !7is at Normal.  Super DTL level can be adjust-
    ed when it is at Super DTL.
    In case of using the RCU (RCB), the above can be
    adjusted with the contour correction switch (DTL). !4Sub Carrier Phase Coarse Adjustment
    [SC Coarse: 1/2/3/4]
    Coarse adjustment of subcarrier phase can be
    made when a genlock signal is supplied.
    !5Subcarrier Phase Fine Adjustment [SC Fine:
    –511 - +511]
    Fine adjustment of subcarrier phase can be made
    when a genlock signal is supplied.
    !6Color Bar Setup Setting  [Color Bar Set:
    0.0 IRE/7.5 IRE]
    The setup level of color bar can be adjusted.
    !7Detail Select Setting [DTL Select: Normal/Super
    DTL]
    If contour correction is not sufficient at the Normal
    position when Detail Level setting !8is set to LOW
    or HIGH, select the Super DTL position.
    !9Noise Suppress Level Setting [Noise Suppress:
    OFF/LOW/HIGH]
    Screen noise can be reduced when Detail Level
    setting !8is at HIGH or LOW. Neither Normal nor Super DTL is valid for contour
    correction if Detail Level setting !8is in the OFF
    position.
    Note 
    						
    							-36-
    @0Flesh Noise Suppress Level Setting [Flesh Noise
    Suppress: OFF/LOW/HIGH]
    Flesh noise is suppressed in two steps when the
    DTL Level is at HIGH or LOW.
    @1Electronic Shutter Setting [Shutter Speed:
    OFF/1/100 to 1/10 000/S/Scan/Auto ND]
    OFF:Electronic shutter is turned off.
    1/100, 1/250, 1/500, 1/1 000, 1/2 000, 1/4 000, 1/10 000:
    Electronic shutter operates at one of these
    speeds as selected.
    S/Scan (Synchro Scan):Electronic shutter oper-
    ates at the speed set with the electronic shutter
    synchro-scan setting @2.
    Auto ND:Electronic shutter is controlled to auto-
    matically adjust the luminance. (ELC)
    @2Electronic Shutter Synchro Scan Setting
    [Synchro Scan: 60.58Hz - 15.75kHz]
    This setting is possible only when Electronic Shutter
    setting @1is at S/Scan.
    Horizontal bar noise can be reduced by synchro-
    scan adjustment in shooting workstation scenes, for
    example. • In case of using the RCU (RCB), none of the
    shutter speeds−1/250, 1/2 000, 1/4 000, and
    1/10 000 can be selected.
    • In case of using the hybrid control panel, only
    OFF, 1/100, or Auto ND (ELC) can be selected.
    • If the lens iris switch is at M (Manual) when oper-
    ating the camera alone or when the iris switch
    on the RCU (RCB) is at AUTO, Auto ND may not
    function.  Set the lens iris switch to A (Auto).
    • Flickering may increase at Auto ND under fluo-
    rescent lights.
    • Auto ND is automatically selected if Auto ND
    (ELC) setting ris set to ON.
    Note 
    						
    							-37-
    Shutter Speed
    OFF
    1/100
    1/250
    1/500
    1/1 000
    1/2 000
    1/4 000
    1/10 000Required luminance ratio
    1
    2
    4
    8
    16
    32
    64
    160 Synchro-scan-
    100.3 Hz
    250.0 Hz
    492.2 Hz
    984.4 Hz
    1.969 kHz
    3.938 kHz
    7.875 kHz
    *For luminance settings at each shutter speed and
    synchro-scan shutter speed, refer to the table
    below.
    @3CCD Read Out Mode Setting [V Resolution:
    Normal/Fine]
    Normal:Normal image.  (CCD storage will be by
    field storage.)
    Fine:Vertical resolution increases. (Vertical resolu-
    tion is raised without increasing residual images
    by frame storage and Electronic shutter.)
    Normal is recommended for general use be-
    cause sensitivity will decrease at the Fine set-
    ting.@4PC Control Access Speed Setting [Baud Rate:
    1 200bps/2 400bps/4 800bps/9 600bps]
    Select a communication speed in controlling the
    camera from the computer.
    @5Negative/Positive Selection
    [Nega/Posi: Posi/Nega]
    Posi:Normal image
    Nega:Image is shown reversed in darkness and
    color.
    @6Aspect Ratio Selection [Aspect Ratio: 16:9/4:3]
    @7Fan ON/OFF [Fan: ON/OFF]
    The cooling fan can be turned off if fan noise is dis-
    turbing in a studio, for example. 
    						
    							-38-
    Sub Menu (User Mode)
    **Iris, Shutter, Gain Set**
     Picture Level         ±0
     Light PEAK/AVG         0
     Light Area       Top cut
     Auto Iris Adjust     OFF
     Shutter Mode      (Step)
      Step              (OFF)
      Synchro Scan        ---
     Field/Frame        Field
     Gain               (0dB)
     Pedestal            (±0)
    Return**Detail Set1**
     Detail            (HIGH)
      H Detail Level H    +11
      V Detail Level H    +12
      H Detail Level L     +7
      V Detail Level L     +6
     Detail Band            2
     Noise Suppress         3
     Level Dependent       0%
     Dark Detail            0
    Return**Color Matrix Set**
     Matrix(R-G)           ±0
     Matrix(R-B)           ±0
     Matrix(G-R)           ±0
     Matrix(G-B)           ±0
     Matrix(B-R)           ±0
     Matrix(B-G)           ±0
    Return
    **Color Set**
     Chroma Level          ±0
     White Bal        (AWC A)
     Highlight Chroma     OFF
     Painting
      R Gain             (±0)
      B Gain             (±0)
      R Pedestal         (±0)
      B Pedestal         (±0)
     2D LPF               OFF
    Return**Detail Set2**
     Chroma Detail          0
     Flesh Noise Suppress OFF
     Corner Detail        OFF
     Precision Detail     OFF
    Return**Other Set1**
     Gamma               0.45
     Knee Point           88%
     White Clip          110%
     Flare R                0
     Flare G                0
     Flare B                0
     Black Stretch        OFF
     Baud Rate        9600bps
     Nega/Posi           Posi
     Aspect Ratio        16:9
    Return
    **Other Set2**
     Fan                   ON
    Return**G/L, Color Bar Set**
     H Phase             (±0)
     SC Coarse            (1)
     SC Fine             (±0)
     Color Bar Set     7.5IRE
     
    Return
    @8
    @9
    #0
    #1
    #2
    #3
    #4
    #5
    #6
    #7
    #8
    #9
    $0
    $3
    $4$7
    $8
    $9
    %0
    %8
    %9
    ^0
    ^1
    ^2
    ^3
    ^4
    ^5
    ^6 $1
    $2
    $5
    $6%1
    %2
    %3
    %4
    %5
    %6%7
    • Settings enclosed in parentheses can be set with the RCU (RCB) switch or VR in RCU (RCB) mode.
    • To return to the initial settings, refer to page 46. 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Convertible Camera Aw E800 Operating Instructions