-21- CONNECTION WITH MULTIPLE CAMERAS (COLOR LOCK MODE) •An example of connection for VBS/BB input (Color lock mode). •One of the multiple cameras is used as the source of ref- erence signals. •Supply a synchronizing signal (BB) to the G/L Input Connectors of each cameras.•Do not switch off the camera used for supplying the reference signals. •Adjust the SC-phase and H-phase at the Video Output Connector. 30 10 m 5 3 21.5 0 II 15 10 7 5 1 5.5 10 20 40 77 30 10 m 5 3 21.5 0 II 15 10 7 5 1 5.5 10 20 40 77 30 10 m 5 3 21.5 0 II 15 10 7 5 1 5.5 10 20 40 77 VIDEO OUT CAMERA Camera for External Sync (or Special Effect Generator)G/L IN VIDEO OUT OUTPUT INPUT Video Output To Special Effect Generator or Monitoring SystemVideo Distributor WJ-300C External Sync Signal (BB)
-22- CONNECTION OF COMPUTER The AW-CA50T9 PC control cable is required to control the camera using a computer. Consult your dealer for details. The user is responsible for providing the software used to control the camera. O IFUSEFUSE DC Power Cable AW-CA4T1 Computer VIDEO OUT Connector AC ADAPTOR AW-PS50575 ΩCoaxial Cable Composite Video Input Connector (VIDEO IN)Video Monitor RS-232C PC Control Cable AW-CA50T9 (10m) CONNECTION OF DEVICES WITH CAMERA PAN/TILT CONTROL SYSTEM • Refer to the operating instructions of the pan/tilt head to connect camera to it.
-23- AUTOMATIC WHITE BALANCE CONTROL (AWC) There are two white balance memories, “AWC A” or “AWC B” for two different light sources color tempera- tures, with the automatic white balance setting. Then, when the two different light sources are encountered, you may operate the camera properly by simply change the white balance mode to either AWC A or AWC B. There is no need to readjust the camera to the ambient conditions. * The preset conditions will be renewed whenever you input new conditions. 1. Turn the white balance selection switch to either “AWC A” or “AWC B” of RCU or select the white balance mode either AWC A or AWC B by menu. 2. Aim the camera at a white object (a white wall or a white handkerchief) and zoom in to enlarge the image as much as possible. [ADJUSTMENT by CAMERA] 3. In normal shooting mode: Press the ITEM/AWC switch for over 2 second. [ADJUSTMENT with the RCU (RCB, Hybrid control panel)] 4. When the AUTO set switch is turned to AWC, the white balance will be automatically set. While the system is being set, auto warning indicator (LED) blinks and it goes out when the white balance set- ting is completed. If the lamp remains lit, the setting must be tried again. RCU (RCB)CAMERA ADJUSTMENT ITEM/AWC Switch AUTO LED AUTO set Switch
-24- Notes: •For white balance setting aim the camera at a white object and try to position it in the center of the monitor screen. The object must appear in over 10 % of the total monitor screen area. Try to avoid overly bright objects in the scene. •White balance may not be correctly set if the lighting of the object is too weak. •Since the camera has a built-in memory, the set white balance will remain in the memory even if power is turned off. Therefore, it is not neces- sary to reset the white balance if the color tem- perature of those objects remains unchanged. However, it must be reset if the color tempera- ture changes, such as when you move from indoors to outside, or vice versa. •When the camera is used without a RCU or RCB red/blue gain adjustment of painting set- ting will be automatically reset to ±0 after set- ting the white balance. (painting setting in only USER MODE.) The white object must occupy over 10 % of the monitor screen area. AUTOMATIC TRACKING WHITE BALANCE SETTING (ATW) White balance will be automatically set to continuously match changes of light source and color temperature while the white balance setting is set to ATW. Notes:•ATW might not function properly when high bright- ness light (ex. fluorescent lamp) beams into a screen. •White balance may not be accurately set if there is no white object in the scene being shot . MANUAL WHITE BALANCE SETTING [ADJUSTMENT by CAMERA] Manual setting is possible in USER MODE only. 1. Select the white balance mode either AWC A or AWC B by menu. 2. Aim the camera at a large white object. Press the ITEM/AWC switch for over 2 second. 3. Adjust the red gain/blue gain control in the PAINT- ING item of Color Set sub menu of USER MODE until the carrier wave of the white portion of the video signal is at the minimum width or the white object in the monitor screen appears pure white. (Use an oscilloscope or a waveform monitor for pre- cise adjustment.) [ADJUSTMENT with the RCU (RCB)] After AWC setting, adjust the R/B GAIN controller in the same way as described in Step 3 above.
-25- RESET TO 3 200K OR 5 600K WHITE BALANCE When the white balance setting is set to either “P SET 3 200K” or “P SET 5 600K” the white balance will be automatically set to the color temperature 3 200K or 5 600K, respectively. BLACK BALANCE ADJUSTMENT •Close the lens. If the motor drive lens is controlled from the cam- era, the lens is automatically closed when the black balance is adjusted. •When the camera is used without a RCU or RCB, R/B pedestal adjustment of painting setting will be automatically reset to ±0 after setting the black bal- ance. (painting setting in only USER MODE.) [ADJUSTMENT by CAMERA] Press the YES/ABC switch for over 2 seconds and the black balance will be set automatically in 10 seconds. Minimize the carrier wave using the red & blue gain controls Waveform for white balance set chart In user mode, black balance fine adjustment can be performed with the red pedestal/blue pedestal setting after setting the black balance. [ADJUSTMENT with the RCU (RCB, Hybrid control panel)] Set the AUTO set switch to ABC and the black balance will be automatically set. While the system is being set, the auto warning indicator (LED) blinks and it goes out when the black balance setting is completed. If the lamp remains lit, ABC should be tried again. YES/ABC Switch AUTO LED AUTO Set Switch ABC
-26- TOTAL PEDESTAL LEVEL ADJUST- MENT (Use an oscilloscope or a waveform monitor for this adjustment.) This step is to adjust the black levels (pedestal levels) of two or more cameras to be the same. [ADJUSTMENT by CAMERA] 1. Close the lens. 2. Select Pedestal item in the brightness setting Sub Menu (Select [Pedestal] in the [Iris, Shutter, Gain Set] sub menu in USER MODE.) 3. Set the pedestal level to 5 IRE (0.035 V) with the YES/ABC switch or the NO/BAR switch. [ADJUSTMENT with RCU (RCB, Hybrid control panel)] Adjust the pedestal level to 5 IRE with the total pedestal adjustment.NO/BAR Switch YES/ABC Switch5 IRE (0.035 V) TOTAL PEDESTAL **Brightness Set** Picture Level ±0 Light PEAK/AVG 0 Light Area Top Cut Auto ND(ELC) (OFF) Auto Gain Up (OFF) AGC Max Gain (---) Manual Gain Up (0dB) Digital Gain Up 0dB Charge Time OFF Pedestal (±0) Return
-27- [ADJUSTMENT by CAMERA] 1. Press the NO/BAR switch for over 5 seconds to dis- play the color bar. 2. Select [G/L Adjustment] on the main menu, then select [H PHASE] on the submenu. 3. Adjust the horizontal phase with the YES/ABC and NO/BAR switch. External gen-lock input signal (black burst output of special effect generator) Video signal [ADJUSTMENT with RCU (RCB, Hybrid control panel)] Use the horizontal phase control. GEN-LOCK ADJUSTMENT Phase adjustments must be performed with the camera or the RCU (RCB) when external synchronizing signals are supplied to the system in cases where multiple cameras are used or peripheral devices are connected. HORIZONTAL PHASE CONTROL Observe the waveform of the external synchronizing input signal (black burst signal) and video output signal on a two-channel oscilloscope. Then match the horizon- tal phase of both signals by adjusting them with the cameras or RCUs horizontal phase control. Adjust the horizontal phase NO/BAR Switch YES/ABC Switch **G/L Adjustment Set** H Phase (±0) SC Coarse ( 1) SC Fine (±0) Color Bar Set 7.5IRE Return Horizontal phase control Subcarrier phase coarse control Subcarrier phase fine control
-28- COLOR PHASE ADJUSTMENT Supply the output signal (split color bar) from the color special effect generator to a color monitor or vec- torscope. Adjust the color phase of the camera. [ADJUSTMENT with RCU (RCB, Hybrid control panel)] Use the subcarrier phase coarse adjustment control and subcarrier phase fine control. * It is recommended that a vectorscope be used for maximum accuracy in color phase adjustment. [ADJUSTMENT by CAMERA] 1. Press the NO/BAR switch for over 5 seconds for the color bar mode. 2. Select [G/L Adjustment] on the main menu, then select [SC Coarse] on the sub menu. 3. Make coarse adjustment with the YES/ABC switch and the NO/BAR switch. CAUTION: When horizontal phase adjustment is required using RCU (RCB) or Hybrid Control Panel, BAR/CAM switch should be set to BAR. Horizontal phase cannot be adjusted if the switch is in the CAM position. After adjustment set BAR/CAM switch back to CAM. CAUTION: When color phase adjustment is required using RCU (RCB) or Hybrid Control Panel, BAR/CAM switch should be set to BAR. Color phase cannot be adjusted if the switch is in the CAM position. After adjustment set BAR/CAM switch back to CAM.4. Select [SC Fine] on the sub menu. Perform fine adjustment with the YES/ABC switch and the NO/BAR switch. **G/L Adjustment Set** H Phase (±0) SC Coarse ( 1) SC Fine (±0) Color Bar Set 7.5IRE Return Color bar of camera Color bar of special effects generator Sprit line
-29- Use Mode Setting The camera has four use modes, and various functions for four use modes have been preset. Functions can be set as best suited to each use mode. •Halogen mode Suited to indoor shooting, such as at weddings, parties, lecture meetings, events, etc. Settings can be changed using a simple menu. •Fluorescent mode Suited to indoor shooting under fluorescent lighting. Settings can be changed using a simple menu. •Outdoor mode Suited to outdoor shooting. Settings can be changed using a simple menu. •User mode Settings can be changed using a detail menu. SETTING BY CAMERA 1. Turn the camera on while keeping the MENU switch depressed. The use mode setting menu shown at right appears on the monitor screen and one of the use mode blinks.2. Press the MENU switch, ITEM/AWC switch, or NO/BAR switch to let the desired use mode blink. MENU switch ( A): The blinking item moves up by one. ITEM/AWC switch ( S), NO/BAR switch (–): The blinking item moves down by one. 3. Press the YES/ABC Switch. The blinking use mode comes into effect. After the use mode setting menu is shown for about 5 sec- onds, the camera returns to be ready for operation. Then, the camera operates in the selected use mode. USE MODE SETTING **Use Mode Set** Halogen Fluorescent Outdoor User
Operation mode -30- SETTING BY RCU (RCB) OR HYBRID CONTROL PANEL An operation mode is selected depending on the posi- tion of the scene file switch. Halogen Mode Fluorescent Mode Outdoor Mode Users Mode Scene File Switch Position of RCU (RCB) 1 2 3 USER SETScene File Switch Position of Hybrid control panel 1 2 3 4 CAMERA RCU (RCB) Hybrid Control Panel ITEM/AWC YES/ABC NO/BAR MENU SCENE FILE SwitchSCENE FILE Switch