Convertible Camera AW-E750 AW-E655 AW-E650 AW-E350 Before attempting to connect, operate or adjust this product, please read these instructions completely. AW-E350 AW-E750AW-E650 AW-E655
Page 2
-2- CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point...
Page 3
-3- CONTENTS PREFACE ................................................................................................................................................................................ 4 FEATURES .............................................................................................................................................................................. 5 SPECIAL NOTES ON OPERATION...
Page 4
-4- • The Panasonic AW-E750, AW-E655, AW-E650 and AW-E350 are digital signal processing color video cameras that incorporates three CCDs; 2/3 3CCD (AW-E750) 1/2 3CCD (AW-E655, AW-E650) 1/3 3CCD (AW-E350) A digital video signal processing system is packed in a compact, lightweight body while assuring high picture quality, high reliability and high performance. • System setup and adjustments can be easily performed by following the setup menu. • Connection to peripheral devices, such as a RCU, a RCB and...
Page 5
-5- 1. Digital video signal processing for high quality, high reliability, high performance, lightweight and compact size. 2. Resolution: 850 lines (HIGH BAND DTL: ON) S/N ratio: 67dB (DNR ON) (AW-E750, AW-E655, AW-E650) 66dB (DNR ON) (AW-E350) 3. Minimum illumination: 0.00005 lx (AW-E750, AW-E655, AW-E650) 0.00015 lx (AW-E350) 4. The built-in CCD storage function and digital gain up function provide an even higher degree of high sensitivity. 5. RGB, Y/Pr/Pb and Y/C signal output circuits provided. 6....
Page 6
-6- • Turn power off before connecting or disconnecting cables. • Connection or disconnection of any studio cable, RCB cable or other cable to any unit of equipment must be performed while power is off. • While the camera is in automatic mode; Shooting of bright objects in ELC operation mode may result in a smeared picture unique to the CCD. The ATW function under fluorescent illumination can adversely change the white balance. SPECIAL NOTES ON OPERATION • There is a cooling fan inside. Do not cover the...
Page 7
-7- DONTS • Do not attempt to disassemble the camera, Remote Control Unit (RCU) or other units. In order to pre- vent electric shock, do not remove screws or cov- ers. There are no user-serviceable parts inside. • Do not abuse the camera. Avoid striking, shaking, etc. The camera contains sensitive components which could be damaged by improper handling or storage. • Do not let the lens remain uncapped when the cam- era is not in use. If the lens is not installed, do not leave the lens mount hole...
Page 8
-8- • Take immediate action if ever the camera or RCU should become wet. Turn the power off and have the unit checked by an authorized service facility. • Follow normal safety precautions to avoid personal injury. • Use the camera in an environment where the tem- perature is within 14°F to 113°F (−10°C to +45°C), and the relative humidity is within 30 % to 90 %. • Always turn the power off when the camera is not going to be used. Operate the camera and RCU only when there is adequate ventilation. DOS •...
Page 10
-10- 2. Lens fixing ring knob Rotate the lens fixing ring knob counterclockwise and remove the lens mount cap. Mount the lens on the camera and rotate the lens fixing ring knob clockwise in order to fix the lens securely. 3. Mic Jack (model AW-E655 only) This is a ø3.5 mm mic jack which supports PLUG IN POWER. Use the microphone which has more than 1kΩof impedance, unbalanced. 4. Mounting hole To install the camera on a wall or ceiling or to use a pan/tilt head or tripod, secure the unit using this screw...