-29- nGEN-LOCK ADJUSTMENT Phase adjustments must be performed with the camera or the RCU (RCB) when external synchronizing signals are supplied to the system in cases where multiple cameras are used or peripheral devices are connected. nHORIZONTAL PHASE CONTROL Observe the waveform of the external synchronizing input signal (black burst signal) and video output signal on a two-channel oscilloscope. Then match the horizontal phase of both signals by adjusting them with the cameras or RCUs horizontal phase control.[ADJUSTMENT by CAMERA] 1. Press the BAR (DOWN) switch for over 1 second to display the color bar. 2. Select page No.4 of INITIAL SET menu. 3. Select “H PHASE” with the item switch. 4. Adjust the horizontal phase with the Up switch and Down switch. NO.4 ** INITIAL ** H PHASE +....I....- SC COARSE 0° SC FINE +....I....- RET END PAGE ITEM UP DOWN COARSE FINE SC PHASE270 180 90 0 H.PHASE USER SET OFF ENC VF ON Horizontal phase control Subcarrier phase coarse control Subcarrier phase fine control External gen-lock input signal (black burst output of special effect generator)Video signal [ADJUSTMENT WITH RCU (RCB)] Use the horizontal phase control located in the pocket of RCU (RCB).
NO.4 ** INITIAL ** H PHASE +....I....- SC COARSE 0° SC FINE +....I....- RET END -30- nCOLOR PHASE ADJUSTMENT Supply the output signal (split color bar) from the color special effect generator to a color monitor or vectorscope. Adjust the color phase of the camera with either the cam- era controls or the RCU (RCB) control. [ADJUSTMENT WITH RCU (RCB)] Use the subcarrier phase coarse adjustment control and subcarrier phase fine control located in the pocket. * It is recommended that a vectorscope be used for maximum accuracy in color phase adjustment. [ADJUSTMENT by CAMERA] 1. Press the BAR (DOWN) switch for over 1 second for the color bar mode. 2. Select page No.4 of INITIAL SET menu. 3. Select “SC COARSE” with the item switch. Make coarse adjustment with the Up switch and the Down switch. 4. Select “SC FINE” with the item switch. Perform fine adjustment with the Up switch and the Down switch. Magenta Green Cyan Yellow White Red Blue BlackMagenta Green Cyan Yellow White Red Blue Color bar of cameraColor bar of special effects generator
-31- OPERATION MODE SETTING• Operation Mode Setting The camera has three memories, including the setup mem- ory, initial set memory and scene file memory, and various functions for four operation modes, are preset in the facto- ry. Functions can be set as best suited to each operation mode. MODE 1: For shooting mainly indoors MODE 2: For monitoring indoors and outdoors MODE 3: For microscopic shooting MODE 4: For video processing and telop shooting • Settings 1. When power is turned on the camera, the operation mode selection as shown on the right figure appears on the monitor screen. 2. One of the operation modes appears blinking and changes each time the item switch is pressed. 3. Press the page switch to select the desired mode while it is blinking. NOTE: Please refer SETUP/INITIAL SET AND THEIR INITIAL VALUE TABLE for the details. CURR:MODE1/SCENE1 MODE1 MODE2 MODE3 MODE4
-32- 4. The camera is now in scene file set mode and as shown on the right figure on the top appear on the monitor screen. 5. One of the scene files appears blinking and changes each time the item switch is pressed. 6. Press the page switch to select the desired scene file number while it is blinking. 7. Now the mode setting is completed and the new mode will be indicated on the screen for 2 seconds before the camera returns to normal shooting mode. * When the camera is controlled with the RCU (RCB) a scene file is selected by the scene switch on the RCU (RCB) and those figure will not be displayed. CURR:MODE1/SCENE1CURR:MODE1/SCENE1 SCENE1 SCENE2 SCENE3 USER A USER B
-33- MENU ITEM SETTINGSetup Item SettingnSetup Memory The AW-E560 has a setup menu memory, which stores data on the states of the individual functions of the camera preset before shipment from the factory. Camera operating conditions can be set using the setup function. The camera has a memory for each mode. nSetup State Camera alone: Press the page switch for 2 seconds or more. Camera with RCU (RCB): Set the user set switch to ON. When the camera has been placed in the setup state, the SETUP menu is displayed on the monitor. Setup operations can be performed at the camera head or RCU (RCB). * Composite signals are output from the VIDEO output terminal regardless of the position (ENC/VF) of the user set switch on the RCU (RCB).nSetup Data Screen * When the camera is used with an RCU (RCB), those items enclosed in parentheses can be adjusted with the switches and controls on the RCU (RCB). The word END is displayed only when the camera is used alone. ** SETUP ** GAIN AGC HIGH IRIS AUTO SHUTTER OFF WHITE BAL ATW DTL LEVEL LOW SCENE FILE USER A INIT USER END** SETUP ** GAIN ( AGC LOW ) IRIS ( AUTO ) SHUTTER ( OFF ) WHITE BAL ( ATW ) DTL LEVEL ( LOW ) SCENE FILE ( USER A ) INIT USER 1 2 3 4 5 6
-34- 1Gain Up Control Setting [GAIN: AGC LOW, AGC HIGH, 0DB, 9DB, 18DB] When the mode is set to AGC LOW or AGC HIGH, the AGC with a maximum gain increase of about 9 dB/18 dB operates to control gain up and automatically reg- ulate the amount of light. Normally, the mode should be set to 0DB. If a suffi- cient video output is not obtained in shooting a dark object even when the iris is fully opened, set the mode to the 9DB or 18DB position. • AGC convergence level, photometric method, and detecting ratio can be set by INITIAL SET menu. Note: In using the AGC, it may not function when the iris switch is in the manual position on the lens with auto iris ON in the SETUP menu. 2Iris Control Setting [IRIS: MANU, AUTO] When the mode is set to AUTO, lens iris is controlled automatically with lens iris is A (auto) position. • Auto iris convergence level, photometric method, and detecting ratio can be set by INITIAL SET menu. Note: When the iris control is set to AUTO in this menu, set the iris switch on the lens to the A (auto) posi- tion. If the iris is set to MANU in this menu, set the iris switch on the lens to the M (manual) position.3Electronic Shutter Speed Setting [SHUTTER: ELC, OFF, 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000, SYNCHRO] When the mode is set to ELC, the electronic shutter speed is automatically controlled to regulate the amount of light. When the mode is set to OFF, the electronic shutter is turned off. The mode is set to between 1/100 and 1/10000 represent respective shutter speeds. Set the mode to SYNCHRO (synchro scan) for fine adjustment of shutter speed. * Refer to the table below for the relative light quantity required for each setting of shutter speed and synchro scan. Shutter Speed Synchro Scan Required Light Ratio OFF -- 11/100 159/525 21/250 63/525 41/500 31/525 81/1000 15/525 161/2000 7/525 321/4000 3/525 64 1/10000 1/525 160 * ELC convergence level, photometric method, and detecting ratio can be set by INITIAL SET menu. When the mode is set to SYNCHRO, shutter speed can be set by INITIAL SET menu. Note:If the camera is used with an RCU (RCB), shut- ter speeds of 1/250, 1/2000, 1/4000, 1/10000 can- not be selected.
-35- When the mode is set to ELC, the electronic shutter may not function if the iris is set to AUTO in the SETUP menu and the lens iris switch to M (manual). Make sure that the camera and lens settings are the same. If ELC is selected, flicker may increase under fluores- cent lights. 4White Balance Setting [WHITE BAL: ATW, A CH, B CH, MANU, P SET 3.2K, P SET 5.6K] When the mode is set to ATW, white balance is auto- matically adjusted at all times. When the mode is set to A CH or B CH, with SETUP menu OFF, white balance is automatically adjusted with the AWC switch on the back of the camera. Color temperature conditions of two scenes can be stored in the A CH/B CH memories. When the painting mode is ON, fine color adjustment can be made by red/blue gain setting of INITIAL SET menu after AWC. When the mode is set to MANU, white balance can be adjusted by red/blue gain setting of INITIAL SET menu. When the mode is set to P SET 3.2K, white balance is adjusted to 3200K illumination. When the mode is set to P SET 5.6K, white balance is adjusted to 5600K illumination. Note: When the camera is used with an RCU (RCB), the switch cannot be set to MANU, P SET 3.2K, or P SET 5.6K.5Detail Level Setting [DTL LEVEL: OFF, LOW, HIGH] Use this mode to select any of three detail levels as desired: HIGH, LOW, OFF. * Low or high level ranges can be set by using a USER SET menu. 6Scene File Selection Setting [SCENE FILE: 1, 2, 3, USER A, USER B] Mode 1: USER A/B -- User set SCENE 1: SCENE 2: SCENE 3: Mode 2: USER A/B -- User set SCENE 1: SCENE 2: SCENE 3: Mode 3: USER A/B -- User set SCENE 1: SCENE 2: SCENE 3: Mode 4: USER A/B -- User set SCENE 1: SCENE 2: SCENE 3: * USER A and B have a memory for each operation mode (8 in total).
** SETUP ** GAIN AGC HIGH IRIS AUTO SHUTTER OFF WHITE BAL ATW DTL LEVEL LOW SCENE FILE USER A INIT USER END -36- nHow to Read ScreensnHow to Set (1) The cursor (blinking) moves each time the item switch is pressed. The item indicated by the cursor can be reset or its command can be executed. (2) Use the Up and Down switches to change settings. (3) When the page switch is pressed after moving the cursor to INIT, the INITIAL SET menu will displayed. (4) When the page switch is pressed after moving the cursor to USER, the camera is ready for user setting. (5) To terminate camera setup, move the cursor to END, and press the page switch. If the camera is used with an RCU (RCB), set the user set switch to OFF. The camera will then operate according to the set- tings. INITIAL SET MENU SETTINGnInitial Set Memory The AW-E560 has an initial set memory, which stores data on the states of the individual functions of the camera pre- set before shipment from the factory. Camera operating conditions can be set using the initial set function. The camera has a memory for each mode. Cursor (blinking) Set parameter To enter initial set state To enter user set state To return to normal state (camera alone)
-37- nInitial Set State (1) Display the SETUP menu by pressing the page button. (2) Move the cursor to INIT and press the page switch. The camera is initialized and the INITIAL set menu is displayed on the monitor. Setup operation can be per- formed at the camera head or RCU (RCB). nInitial Set Screen NO.1 ** INITIAL ** R GAIN (+....I....-) B GAIN (+....I....-) T PED (+....I....-) R PED (+....I....-) B PED (+....I....-) PAINTING OFF RETNO.2 ** INITIAL ** AGC AUTO IRIS ELC LEVEL +....I....- AREA ALL PEAK/AVG P....I....A AUTO IRIS ADJ OFF RET On No. 2 page, the light adjusting function that is now ON is displayed on the second line from the top. * When the camera is used with an RCU (RCB), those items enclosed in parentheses can be adjusted with the switches and controls on the RCU (RCB). The word END is displayed only when the camera is used alone. NO.1 ** INITIAL ** R GAIN +....I....- B GAIN +....I....- T PED +....I....- R PED +....I....- B PED +....I....- PAINTING OFF RET ENDNO.2 ** INITIAL ** AGC AUTO IRIS LEVEL +....I....- AREA ALL PEAK/AVG P....I....A AUTO IRIS ADJ OFF RET END 7 8 9 !0 !1 !2 !3 !4 !5 !6
NO.5 ** INITIAL ** OUTPUT SEL1 R/G/B OUTPUT SEL2 Y/C SYNC SEL 0.3V CAMERA ID OFF TIME DATE OFF RET END NO.5 ** INITIAL ** OUTPUT SEL1 R/G/B OUTPUT SEL2 Y/C SYNC SEL 0.3V CAMERA ID OFF TIME DATE OFF RET NO.3 ** INITIAL ** SYNCHRO-SCAN 253/525 FLD/FRM FIELD GAMMA ON 2D LPF OFF COLOR BAR 1 RET END NO.3 ** INITIAL ** SYNCHRO-SCAN 253/525 FLD/FRM FIELD GAMMA ON 2D LPF OFF COLOR BAR 1 RET -38- NO.4 ** INITIAL ** H PHASE (+....I....-) SC COARSE ( 0° ) SC FINE (+....I....-) RET NO.4 ** INITIAL ** H PHASE +....I....- SC COARSE 0° SC FINE +....I....- RET END !7 !8 !9 @0 @1 @5 @6 @7 @8 @9 @2 @3 @4