Page 21
21 t Mount the supplied base cover on the camera mount bracket. Important: • To prevent the cables from being caught when the base cover is attached, keep the cables inside the cable guide. y Use the bit for tamperproof screw (acces- sory) to tighten the fixing screws provided on both sides of the base cover. (Recommended tightening torque: 0.78 N·m) Base cover Base cover fixing screw
Page 22
22 x Remove the enclosure and inner dome from the main body by loos- ening the three fixing screws. Loosen the three fixing screws by using the provided bit for tamperproof screw. Detach the inner dome while pushing the parts with the "PUSH" indication. Important: • Do not hold the inner dome when carrying the camera. Otherwise, the camera part may fall and it may damage the camera. Note: • Perform the same procedure when replac- ing with the...
Page 23
23 Adjust the camera z Be sure to view the monitor for adjustment when the camera angle is adjusted. \ Connect the monitor for adjustment (e.g. a small LCD) to the monitor output connector, and adjust the camera angle. When determining the camera angle, repeat fine follow the adjusting procedure of q, w, and e shown below. q Loosen the panning lock screw and rotate the camera head horizontally to adjust panning, and tighten the panning lock screw. w Loosen...
Page 24
24 x Adjusts the focus. Focus adjustment shall be performed when camera angle adjustment are performed. Adjust the focus by following the adjusting proce- dure of q, w, and e shown below. q Loosen the zoom lock knob and move the knob between TELE and WIDE to obtain the appropriate angle of view, and then tighten the zoom lock knob. w Loosen the focus lock knob, make coarse adjustment of the focus, and then tighten the focus lock knob. e...
Page 25
25 v To perform fine adjustment of the back focus after the ABF operation indi\ cator goes off and automatic back focus is adjusted, use the right or left button. Note: • No operation for 10 seconds or more automatically clears the focus position indicator. • To change the angle of view by moving the zoom adjustment ring, also move the focus lock knob to adjust the focus. • The originally adjusted focus may be slightly off depending on the iris state resulting from the...
Page 26
26 b Mount the enclosure and inner dome. Tighten the screws that have been loos- ened in Step 2 in page 22 using the sup- plied driver bit. (Recommended tightening torque: 0.78 N·m) Important: • Attach the inner dome in accordance with the lens direction to not to change the lens direction. • Check if the tabs of the inner dome are firmly fit. • Remove the cushioning (pink sheet) from the inside of the dome and the protection sheet from...
Page 27
27 Waterproof treatment for the cable joint sections Adequate waterproof treatment is required for the cables when the camera with exposed cables is installed by means of the camera mount bracket or it is installed under the eaves. The camera body is waterproof, but the cable ends are not waterproof. Be sure to use the supplied butyl tape at the connection parts of the power cord and video output cable to apply waterproof treatment in the following procedure. Failure to observe this may...
Page 28
28 Important: • If open wiring is conducted, be sure to use conduits and run the cables inside the tubes to pro- tect the cables from direct sunlight. • When the conduit is connected at the lateral or bottom position, either of the arrow marks on the bracket shall be the top position. • When the conduit is connected from the top, the arrow mark on the attachment shall be either of the right or left position. • For installation on the wall, do not...
Page 29
29 Make a connection Cautions: • ONLY CONNECT WV-CW504 TO 24 V AC OR 12 V DC CLASS 2 POWER SUPPLY. (WV-CW504) • Be sure to connect the grounding lead to the GND terminal. * When using 12 V DC power supply, the optional heater unit is unavailable. To 220 V to 240 V AC power supply (WV-CW500) To 24 V AC/12 V DC* power supply (WV-CW504) Video output cable (approx. 16 cm) Brown (Live) Blue (Neutral) Green/Y ellow (GND) To GND** BNC connector BNC connector BNC connectorTo VIDEO IN Power...
Page 30
30 • Shrinking the cable-entry seal is a onetime procedure. Do not shrink the cable-entry seal until it has been ascertained that unit is functioning. ONLY CONNECT THIS TO 24 V AC or 12 V DC CLASS 2 POWER SUPPLY. • Cord length and wire gauge 24 V AC The recommended cord length and copper wire size are shown in the table for reference. The voltage supplied to the camera should be between 19.5 V AC and 28 V AC. Recommended wire gauge for 24 V AC line....