Page 11
11 Major operating controls Power Cable Video Output Connector Decorative Cover Dome Fix Ring Safety Wire Lens The lens cannot be replaced. The dome cover is easily damaged, And should be handled with care. Data Port (RS485) Alarm Output Connector Alarm Input Connector Camera Mounting Base Dome Cover Camera WARNING IMPORTANT
Page 12
12 DIP switch settings Communication Parameters (DIP Switch 2) The factory default settings are all OFF. Switch 1: Terminator (Internal Termination Resistance) Set to ON in the following situations. When 1 camera is connected to this unit When 2 or more cameras are connected to this unit that works as a termination Switches 2 to 4: Communication Parameters This setting toggles between 2-line and 4-line communication. Use these switches to select the communication protocol being used. 1234...
Page 13
13 Unit Number (DIP Switch 1) The factory default settings of these DIP switches are all OFF. (Coaxial Multiplex System) Configuration for using Panasonic Protocol 1234 ON 5678 DIP Switch 1 Unit Number 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234...
Page 14
14 1234 ON 5678 DIP Switch 1 Unit Number 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 DIP Switch 1 Unit Number DIP Switch 1 Unit Number 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234 ON 5678 1234...
Page 15
15 Important: When using Pelco protocol, make sure that the system works properly before use. Some functions using Pelco protocol may be restricted when this camera and the apparatuses (commercially available) compatible with Pelco protocol operate together. Note: When using the Unit Number 1 to 96 of Panasonic Protocol and using the Unit Number 32 to 96 of Pelco-D protocol, the unit number setting needs to be configured using the RS485 SET UP menu. For details about configuring this setting,...
Page 16
16 Camera Installation When installing the camera on a wall or a ceiling, please read the important notice below. Important: Procure 4 screws (M4) to secure the camera to a wall or a ceiling according to the material of the installation area. In this case, wood screws and nails should not be used. For mounting a camera on a concrete wall, use an anchor bolt (for M4) or an AY plug bolt (M4) for securing. (Recommended tightening torque: 1.6 N·m) reinforced or the Ceiling Mount Bracket for the camera,...
Page 17
17 Preparing the Camera andDecorative Cover for Side Cable Exit The camera and decorative cover should be prepared as shown below when mounting the camera on a ceiling or wall with its cables (power, video output, RS485, alarm in, alarm out) exiting from the side. Perform this task when using Ceiling Mount Bracket WV-Q126, or Wall Mount Bracket WV-Q118. The camera mounting base needs to be removed in order to prepare the camera. See steps 1 and 2 below for information about how to remove the...
Page 18
18 5. Connect the cables. Please refer to page 20 for the details of connections. 6. Attach the safety wire for securing the camera to the camera mounting base. Pull on the safety wire to make sure its ring is securely connected to the camera mounting base hook. If the dust protect sheet that comes with the camera is affixed to the camera mounting base, remove it before performing the above step. Safety wire ring Note: to hang from it. Do not apply force greater than the weight of the...
Page 19
19 Uninstalling the Camera Caution: and exactly when uninstalling the camera and decorative cover. Failure to do so creates the risk of damage to the camera. Removing the Decorative Cover Note that you need to separate the two parts of the decorative cover in order to remove it. 1. Unhook the two parts of the decorative cover. Press upwards on the decorative cover at the points marked (indicated by the arrows, in the illustration below) to unhook the two parts from each...
Page 20
20 Connections Precautions The following connections should be made by qualified service personnel or system installers in accordance with all local codes. See the reverse side of the cover page for main lead connection. Turn off the power at the fuse box before starting the installation work, or it so could result in fire, electric shock, personal injury, and material damage. RS485 Data PortAlarm Input ConnectorAlarm Output Connector T(B)T(A)R(B)R(A) Red Orange Yellow Green Data Data...