Home
>
Panasonic
>
Camera Accessories
>
Panasonic Camera Control Unit Ak Hcu931p Operating Instructions
Panasonic Camera Control Unit Ak Hcu931p Operating Instructions
Have a look at the manual Panasonic Camera Control Unit Ak Hcu931p Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 Connections RCP CCUPREVIEW AUX LINKCSU15 14 13 12 11 10 9 8 7 6 5 4 3 2 1POWER DC IN G N D PUSH HDRET1 SDI INPUT SDI OUTPUT RET2 RET3 RET4 OUT1 OUT2 OUT3OUT4/PM Y / G Pb / B Pr / R PMHDOUTPUT SDRET1 SDI INPUT SDI OUTPUT RET2RET1 RET2PROMPTRET3 RET4 OUT1 OUT2 OUT3 OUT4 SD COMMUNICATION WFM1 IN RTS OUT CH–1CH–2DIGITAL AUDIOTRUNK WFM CONTROL AUXROPCSU / MSUALARM GNDMIC OUT WFM2 PM1 PM2 VBS1 VBS2 HD HD REFSD SD OUTPUT INPUT 1 2 SYNC OUTPUT SD REFAC IN PHANT OFFA BPHANT OFFA B( dB)–20–30–40M I C 1–5 0 –60(dB) –20– 30– 40 –5 0 –60M I C 2 R NAM Y /CFILTER LOCAL MONI SELG B 1A CAM/VTRGAINON STBY SAVE HIGHLOW MID BAR ACAM B TEST PRST ONPTTOUTPUTW. BA LUSER SELSD CARD PROMPT signal input (VBSk2) Main line SD outputs (D1 k4) SYNC output for monitor systemSD sync signal input (black burst: BB) MSU connector panel MSU cable ROP connector panel ROP cable Main line SD outputs (VBS k2)SD analog (VBS) RET video input (k2) The HD output unit (AK-HHD931P) is an optional accessory. SD digital (D1) RET video inputs (k4) Video VideoControl Tally inputs (R, G) INCOM input/out- put (ENG, PROD) PGM inputs (PGM1, PGM2) SD WFMSD picture monitor Handy camera (AK-HC931P) Handy camera + build-up unit (AK-HBU931P) Connections for SD system Dedicated ROP cables (available as optional accessories) are used to connect the CCU connector on the ROP unit and the ROP connector on the rear panel of the CCU (this unit). After all the equipment has been connected, set the main power switch on the CCU to ON. Then turn on the camera’s power. OWhen the camera is not connected, the functions that can be controlled by the ROP and MSU are limited to the CCU con- trol items. OThe camera power of the CCU must be turned off without fail before disconnecting the camera or ROP.
12 Connections RCP CCUPREVIEW AUX LINKCSU15 14 13 12 11 10 9 8 7 6 5 4 3 2 1POWER DC IN G N D PUSH HDRET1 SDI INPUT SDI OUTPUT RET2 RET3 RET4 OUT1 OUT2 OUT3OUT4/PM Y / G Pb / B Pr / R PMHDOUTPUT SDRET1 SDI INPUT SDI OUTPUT RET2RET1 RET2PROMPTRET3 RET4 OUT1 OUT2 OUT3 OUT4 SD COMMUNICATION WFM1 IN RTS OUT CH–1CH–2DIGITAL AUDIOTRUNK WFM CONTROL AUXROPCSU / MSUALARM GNDMIC OUT WFM2 PM1 PM2 VBS1 VBS2 HD HD REFSD SD OUTPUT INPUT 1 2 SYNC OUTPUT SD REFAC IN PHANT OFFA BPHANT OFFA B(dB)–20–30– 40M IC 1–50 –60(dB) –20–30–40 –50 –60M IC 2 R NAM Y /CFILTER LOCAL MONI SELG B 1A CAM/VTRGAINON STBY SAVE HIGHLOW MID BAR ACAM B TEST PRST ONPTTOUTPUTW. BA LUSER SELSD CARD PROMPT signal input (VBSk2) HD digital RET video inputs (k4)Main line HD digital outputs (k4) (1 output (OUT4) can be switched to PM output)Main line HD analog output (k1: Y, Pb, Pr/G, B, R) Main line SD outputs (D1k4) SYNC output for SD monitor system HD sync signal input (tri-level sync) Decide on a valid REF input signal using the internal switch. SD sync signal input (black burst: BB) Decide on a valid REF input signal using the internal switch. MSU connector panel MSU cable ROP connector panel ROP cable SYNC output for HD monitor systemMain line SD outputs (VBSk2)SD analog (VBS) RET video inputs (k2) Install the HD output unit (AK-HHD931P) which is an optional accessory. SD digital (D1) RET video inputs (k4) Video VideoControlTally inputs (R, G) INCOM input/out- put (ENG, PROD) PGM inputs (PGM1, PGM2) SD WFMSD picture monitor Handy camera (AK-HC931P) Handy camera + build-up unit (AK-HBU931P) Connections for HD/SD system Dedicated ROP cables (available as optional accessories) are used to connect the CCU connector on the ROP unit and the ROP connector on the rear panel of the CCU (this unit). After all the equipment has been connected, set the main power switch on the CCU to ON. Then turn on the camera’s power. OWhen the camera is not connected, the functions that can be controlled by the ROP and MSU are limited to the CCU con- trol items. OThe camera power of the CCU must be turned off without fail before disconnecting the camera or ROP. OTo configure the HD system, the HD output unit (AK-HHD931P), available as an optional accessory, must be installed.
13 External dimension drawing 132 424 459 CABLE TALLY/CALL OPEN FUSEMAIN HEAD POWER125V 5A FUSE LEVEL PGM PGM 1 SYSTEM PRIVATE MICON PTTOFF OFF PGM 2 250V 5A SHORT ALARM Camera Control Unit PUSH PUSHHD RET1 SDI INPUT SDI OUTPUTRET2 RET3 RET4 OUT1 OUT2 OUT3 OUT4/PM Y / G Pb / B Pr / R PM HD OUTPUT SD RET1 SDI INPUT SDI OUTPUTRET2RET1 RET2 PROMPT RET3 RET4 OUT1 OUT2 OUT3 OUT4 SD COMMUNICATION WFM1 IN RTS OUT CH–1CH–2 DIGITAL AUDIO TRUNK WFM CONTROL AUXROPCSU / MSUALARM GND MIC OUT WFM2 PM1 PM2 VBS1 VBS2 HD HD REFSD SD OUTPUT INPUT 1 2 SYNC OUTPUT SD REF AC IN
14 Specifications Video input/output signals SD digital signal (D1) SD analog signal (VBS) HD digital signal (optional) HD analog signal (Y, Pb, Pr/GBR): Output only (optional) PROMPT signal (VBS): Input only Sync input signals HD reference signal (tri-level sync) SD reference signal (BB) (Select one of these signals using the internal switch.) Audio output signals Analog audio output (MIC 1, 2) Digital audio output (MIC 1, 2) Switch functions Refer to “Parts and their functions” (page 4). Operating temperature range 0 to i40 ˚C (i32 to 104 ˚F) Storage temperature range j20 to i60 ˚C (j4 to 140 ˚F) Operating ambient humidity Less than 85% Weight Approx. 20.0 kg (44 lbs) Dimensions (WkHkD) 420k132k459 mm (excluding protrusions) (16-9/16k5-1/4k16-9/16 inches) Power supply: AC 120 V Power consumption: 80 W (when unit is operated on its own) indicates safety information. Rack mounting Attach the rack mounting adapter firmly by using a crosshead screwdriver as follows: Mounting screws (k6) Rack mounting adapter
PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY UNIT COMPANY OF PANASONIC CORPORATION OF NORTH AMERICA Executive Office: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7000 EASTERN ZONE: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7621 Southeast Region: 1225 Northbrook Parkway, Ste 1-160, Suwanee, GA 30024 (770) 338-6835 Central Region: 1707 N Randall Road E1-C-1, Elgin, IL 60123 (847) 468-5200 WESTERN ZONE: 3330 Cahuenga Blvd W., Los Angeles, CA 90068 (323) 436-3500 Government Marketing Department: 52 West Gude Drive, Rockville, MD 20850 (301) 738-3840 Broadcast PARTS INFORMATION & ORDERING: 9:00 a.m. – 5:00 p.m. (PST) (800) 334-4881/24 Hr. Fax (800) 334-4880 Emergency after hour parts orders (800) 334-4881 TECHNICAL SUPPORT: Emergency 24 Hour Service (800) 222-0741 Panasonic Canada Inc. 5770 Ambler Drive, Mississauga, Ontario L4W 2T3 (905) 624-5010 Panasonic de Mexico S.A. de C.V. Av angel Urraza Num. 1209 Col. de Valle 03100 Mexico, D.F. (52) 1 951 2127 Panasonic Puerto Rico Inc. San Gabriel Industrial Park, 65th Infantry Ave., Km. 9.5, Carolina, Puerto Rico 00630 (787) 750-4300 © 2006 Matsushita Electric Industrial Co., Ltd. All rights reserved. Printed in Japan VQT0A37-4F0802Y4056 DP