    Have a look at the manual Panasonic Camera Control Unit Ak Hcu931p Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							11
    Connections
    RCP CCUPREVIEW
    AUX
    LINKCSU15 14 13 12 11 10 9 8 7 6 5 4 3 2 1POWER
    DC  IN
    G N D
    PUSH
    HDRET1
    SDI   INPUT SDI   OUTPUT
    RET2 RET3 RET4 OUT1 OUT2 OUT3OUT4/PM Y / G Pb / B Pr / R PMHDOUTPUT
    SDRET1
    SDI   INPUT SDI   OUTPUT
    RET2RET1 RET2PROMPTRET3 RET4 OUT1 OUT2 OUT3 OUT4
    SD
    COMMUNICATION
    WFM1
    IN RTS
    OUT CH–1CH–2DIGITAL  AUDIOTRUNK WFM  CONTROL
    AUXROPCSU / MSUALARM
    GNDMIC  OUT
    WFM2 PM1 PM2 VBS1 VBS2 HD HD REFSD
    SD
    OUTPUT
    INPUT 1 2
    SYNC  OUTPUT
    SD REFAC    IN
    PHANT
    OFFA
    BPHANT
    OFFA
    B(
    dB)–20–30–40M
    I
    C
    1–5
    0
    –60(dB) –20–
    30–
    40
    –5
    0
    –60M
    I
    C
    2
    R
    NAM
    Y /CFILTER  LOCAL   MONI  SELG
    B
    1A
    CAM/VTRGAINON
    STBY SAVE HIGHLOW
    MID BAR ACAM B
    TEST PRST ONPTTOUTPUTW. BA LUSER  SELSD  CARD
    PROMPT signal
    input (VBSk2) Main line SD
    outputs (D1 k4)
    SYNC output for
    monitor systemSD sync signal input
    (black burst: BB)
    MSU connector panel
    MSU cable
    ROP connector panel
    ROP cable
    Main line SD
    outputs 
    (VBS k2)SD analog (VBS) RET video input (k2)
    The HD output unit (AK-HHD931P) is
    an optional accessory. SD digital (D1)
    RET video inputs
    (k4)
    Video VideoControl
    Tally inputs (R, G)
    INCOM input/out-
    put (ENG, PROD)
    PGM inputs
    (PGM1, PGM2)
    SD WFMSD picture monitor Handy camera
    (AK-HC931P)
    Handy camera + build-up unit
    (AK-HBU931P)
    Connections for SD system
    Dedicated ROP cables (available as optional accessories) are used to connect the CCU connector on the ROP unit and the
    ROP connector on the rear panel of the CCU (this unit).
    After all the equipment has been connected, set the main power switch on the CCU to ON.  Then turn on the camera’s
    power.
    
    OWhen the camera is not connected, the functions that can be controlled by the ROP and MSU are limited to the CCU con-
    trol items.
    OThe camera power of the CCU must be turned off without fail before disconnecting the camera or ROP. 
    						
    							12
    Connections
    RCP CCUPREVIEW
    AUX
    LINKCSU15 14 13 12 11 10 9 8 7 6 5 4 3 2 1POWER
    DC  IN
    G N D
    PUSH
    HDRET1
    SDI   INPUT SDI   OUTPUT
    RET2 RET3 RET4 OUT1 OUT2 OUT3OUT4/PM Y / G Pb / B Pr / R PMHDOUTPUT
    SDRET1
    SDI   INPUT SDI   OUTPUT
    RET2RET1 RET2PROMPTRET3 RET4 OUT1 OUT2 OUT3 OUT4
    SD
    COMMUNICATION
    WFM1
    IN RTS
    OUT CH–1CH–2DIGITAL  AUDIOTRUNK WFM  CONTROL
    AUXROPCSU / MSUALARM
    GNDMIC  OUT
    WFM2 PM1 PM2 VBS1 VBS2 HD HD REFSD
    SD
    OUTPUT
    INPUT 1 2
    SYNC  OUTPUT
    SD REFAC    IN
    PHANT
    OFFA
    BPHANT
    OFFA
    B(dB)–20–30–
    40M
    IC
    1–50
    –60(dB) –20–30–40
    –50
    –60M
    IC
    2
    R
    NAM
    Y /CFILTER  LOCAL   MONI  SELG
    B
    1A
    CAM/VTRGAINON
    STBY SAVE HIGHLOW
    MID BAR ACAM B
    TEST PRST ONPTTOUTPUTW. BA LUSER  SELSD  CARD
    PROMPT signal input
    (VBSk2) HD digital RET
    video inputs (k4)Main line HD digital outputs
    (k4)  (1 output (OUT4) can be
    switched to PM output)Main line HD analog output
    (k1: Y, Pb, Pr/G, B, R)
    Main line SD
    outputs (D1k4)
    SYNC output for
    SD monitor system
    HD sync signal input 
    (tri-level sync)
    Decide on a valid REF
    input signal using the
    internal switch.
    SD sync signal input 
    (black burst: BB)
    Decide on a valid REF input signal
    using the internal switch.
    MSU connector panel
    MSU cable
    ROP connector panel
    ROP cable
    SYNC output for
    HD monitor systemMain line SD
    outputs
    (VBSk2)SD analog (VBS) RET video
    inputs (k2)
    Install the HD output unit (AK-HHD931P)
    which is an optional accessory. SD digital (D1)
    RET video inputs
    (k4)
    Video VideoControlTally inputs (R, G)
    INCOM input/out-
    put (ENG, PROD)
    PGM inputs
    (PGM1, PGM2)
    SD WFMSD picture monitor Handy camera
    (AK-HC931P)
    Handy camera +
    build-up unit
    (AK-HBU931P)
    Connections for HD/SD system
    Dedicated ROP cables (available as optional accessories) are used to connect the CCU connector on the ROP unit and the
    ROP connector on the rear panel of the CCU (this unit).
    After all the equipment has been connected, set the main power switch on the CCU to ON.  Then turn on the camera’s
    power.
    
    OWhen the camera is not connected, the functions that can be controlled by the ROP and MSU are limited to the CCU con-
    trol items.
    OThe camera power of the CCU must be turned off without fail before disconnecting the camera or ROP.
    OTo configure the HD system, the HD output unit (AK-HHD931P), available as an optional accessory, must be installed. 
    						
    							13
    External dimension drawing
    132
    424
    459
    CABLE
    TALLY/CALL
    OPEN
    FUSEMAIN HEAD POWER125V   5A
    FUSE
    LEVEL PGM
    PGM 1
    SYSTEM
    PRIVATE
    MICON
    PTTOFF
    OFF
    PGM 2
    250V   5A
    SHORT ALARM
    Camera  Control  Unit
    PUSH
    PUSHHD
    RET1
    SDI   INPUT SDI   OUTPUTRET2 RET3 RET4 OUT1 OUT2 OUT3
    OUT4/PM Y / G Pb / B Pr / R PM
    HD
    OUTPUT
    SD
    RET1
    SDI   INPUT SDI   OUTPUTRET2RET1 RET2
    PROMPT
    RET3 RET4 OUT1 OUT2 OUT3 OUT4
    SD
    COMMUNICATION
    WFM1
    IN RTS
    OUT CH–1CH–2
    DIGITAL  AUDIO
    TRUNK WFM  CONTROL
    AUXROPCSU / MSUALARM
    GND
    MIC  OUT
    WFM2 PM1 PM2 VBS1 VBS2 HD HD REFSD
    SD
    OUTPUT
    INPUT 1 2
    SYNC  OUTPUT
    SD REF
    AC    IN 
    						
    							14
    Specifications
    Video input/output signals
    SD digital signal (D1)
    SD analog signal (VBS)
    HD digital signal (optional)
    HD analog signal (Y, Pb, Pr/GBR): Output only (optional)
    PROMPT signal (VBS): Input only
    Sync input signals
    HD reference signal (tri-level sync)
    SD reference signal (BB) (Select one of these signals using the internal switch.)
    Audio output signals
    Analog audio output (MIC 1, 2)
    Digital audio output (MIC 1, 2)
    Switch functions
    Refer to “Parts and their functions” (page 4).
    Operating temperature range
    0 to i40 ˚C (i32 to 104 ˚F)
    Storage temperature range
    j20 to i60 ˚C (j4 to 140 ˚F)
    Operating ambient humidity
    Less than 85%
    Weight
    Approx. 20.0 kg (44 lbs)
    Dimensions (WkHkD)
    420k132k459 mm (excluding protrusions)
    (16-9/16k5-1/4k16-9/16 inches) Power supply: AC 120 V
    Power consumption: 80 W (when unit is operated on its own)
    indicates safety information.
    Rack mounting
    Attach the rack mounting adapter firmly by using a crosshead screwdriver as follows:
    Mounting screws (k6)
    Rack mounting adapter 
    						
    							15 
    						
    							PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY
    UNIT COMPANY OF PANASONIC CORPORATION OF NORTH AMERICA
    Executive Office:
    One Panasonic Way 4E-7, Secaucus, NJ 07094   (201) 348-7000
    EASTERN ZONE: 
    One Panasonic Way 4E-7, Secaucus, NJ 07094   (201) 348-7621
    Southeast Region:
    1225 Northbrook Parkway, Ste 1-160, Suwanee, GA 30024   (770) 338-6835
    Central Region:
    1707 N Randall Road E1-C-1, Elgin, IL 60123   (847) 468-5200
    WESTERN ZONE: 
    3330 Cahuenga Blvd W., Los Angeles, CA 90068   (323) 436-3500
    Government Marketing Department:
    52 West Gude Drive, Rockville, MD 20850   (301) 738-3840
    Broadcast PARTS INFORMATION & ORDERING:
    9:00 a.m. – 5:00 p.m. (PST) (800) 334-4881/24 Hr. Fax (800) 334-4880
    Emergency after hour parts orders (800) 334-4881
    TECHNICAL SUPPORT:
    Emergency 24 Hour Service (800) 222-0741
    Panasonic Canada Inc.
    5770 Ambler Drive, Mississauga, Ontario L4W 2T3   (905) 624-5010
    Panasonic de Mexico S.A. de C.V.
    Av angel Urraza Num. 1209 Col. de Valle 03100 Mexico, D.F. (52) 1 951 2127
    Panasonic Puerto Rico Inc.
    San Gabriel Industrial Park, 65th Infantry Ave., Km. 9.5, Carolina, Puerto Rico 00630   (787) 750-4300
    © 2006 Matsushita Electric Industrial Co., Ltd.  All rights reserved.
    Printed in Japan
    VQT0A37-4F0802Y4056 DP 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Camera Control Unit Ak Hcu931p Operating Instructions