Have a look at the manual Panasonic Camera Control Unit Ak Hcu931p Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CABLETALLY/CALLOPEN FUSE M A I NH E A D P O W E R 125V 5AFUSE LEVEL PGM PGM 1 SYSTEM PRIVATE MICON PTTOFF OFF PGM 2 250V 5ASHORT ALARM Camera Control Unit P U S H Model AK-HCU931P Before attempting to connect, operate or adjust this product, please read these instructions completely. Camera Control Unit
Safety precautions 2 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to per- sons. The exclamation point within an equilateral tri- angle is intended to alert the user to the pres- ence of important operating and maintenance (service) instructions in the literature accom- panying the appliance. WARNING: TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS EQUIP- MENT TO RAIN OR MOISTURE. This class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. CAUTION: TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING INTERFERENCE, USE THE RECOMMENDED ACCESSORIES ONLY. FCC Note: This device complies with Part 15 of the FCC Rules. To assure continued compliance follow the attached installation instructions and do not make any unautho- rized modifications. This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inter- ference when the equipment is operated in a commer- cial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio com- munications. Operation of this equipment in a residen- tial area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. indicates safety information. For CANADA CAUTION: This product uses a semiconductor laser system and is a laser class 1 product complies with Radiation Performance Standards, 21CFR SUB- CHAPTER J. Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Don’t make any modifications. Don’t repair by yourself. Refer servicing to qualified personnel. CAUTION: Invisible Laser radiation is emitted from the Optical fiber connector when this product is turned on. Don’t look into directly into the Optical fiber connector of this product. This product contains a CR Coin Cell Lithium Battery which contains Perchlorate Material — special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate.
3 Contents Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Operating precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Parts and their functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 External dimension drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Overview By connecting this unit to the multi-format camera (model AK-HC931P), multi-format images can be input and output. (Some of the functions are available as options.) The unit is connected to the multi-format camera, and it is connected to the remote operation panel (ROP) and master setup unit (MSU) using dedicated multi-purpose cables (available as optional accessories). When the designated multi-purpose cables are used, the distance between from the CCU to the ROP and MSU can be extended up to 50 meters. Accessories Rack-mounting adapters (k2) Mounting screws (M4k8 mm) (k6) BNC termination resistor (k1) Communication connector (k1) Power cord (k1) Operating precautions OHandle the unit carefully. Dropping the unit or subjecting it to strong impact may cause malfunctioning and/or accidents. OOperate the unit within a temperature range of 32oF to 104oF (0oC to i40oC). Operation in locations below 32oF or above 104oF may adversely affect the internal parts. OBe absolutely sure to turn off the power before connecting or disconnecting the cables. ODo not use the unit outdoors. OInstall the unit at a distance of at least 3.3 ft (1 meter) from the monitor. OMaintenance Disconnect the power plug, and wipe the unit with a dry cloth. To remove stubborn dirt, soak a cloth in diluted kitchen detergent and wring it out well, and then wipe the unit gently. OAvoid using benzine, paint thinners or other volatile substances. OIf a chemically treated cloth is to be used, read the precautions for its use carefully. Caution
4 Parts and their functions 1CCU power switch [MAIN] This is the power switch of the camera control unit (CCU). The CCU, ROP and other units will not operate unless this switch is set to ON. Up: ON Down: OFF 2Camera power switch [HEAD POWER] This switch supplies power to the camera. However, if the ROP has been connected, power is supplied to the camera only when this switch and the camera power switch on the TOP are both set to ON. Up: ON Down: OFF 3CCU power ON LED Lighted: The CCU power is ON. Off: The CCU power is OFF. 4Camera power ON LED Lighted: This indicates that power is being supplied from the CCU to the camera. Off: This indicates that power is not being supplied from the CCU to the camera. Even if the camera power switch is ON, this LED remains off if no power is supplied to the camera. This is due to one of the following reasons: 1the supply of power to the camera has been turned off by the ROP, 2one of the optical fiber cables has been disconnected or 3something is wrong with the camera, and the power supply was turned off. 5CCU power fuse This is the CCU main power fuse. 6Camera head power fuse This is the camera head power supply fuse. 7Alarm LED [ALARM] Lighted:This LED indicates that the CCU’s fan has stopped and that something is wrong with the power supply. Off: Normal If the LED remains lighted, turn off the main power and have the unit repaired.8Camera cable open alarm LED [CABLE / OPEN] Lighted: The cable between the CCU and camera has been disconnected. Off: Normal 9Camera cable short-circuit alarm LED [CABLE / SHORT] Lighted: The cable between the CCU and the camera has short-circuited. Off: Normal :TALLY indicator/CALL switch [TALLY/CALL] This indicator lights when the R/G tally signal is input. It is also a CALL switch for calling the camera, ROP and MSU. ;INCOM volume control [LEVEL] This is used to adjust the standby INCOM volume. INCOM selector switch This is used to select the call party of the standby INCOM. PRIVATE: For making private calls to the camera. COMM: For connecting the standby INCOM with the system INCOM. ?INCOM MIC selector switch [MIC] ON: The INCOM microphone is set to ON. OFF: The INCOM microphone is set to OFF. PTTN: The INCOM microphone is set to ON only while the INCOM MIC selector switch is held down. @Standby INCOM jack This is connected to INCOM 1 line, and it enables calls to be made to the camera’s INCOM 1 line. Even when the camera power is OFF, calls can still be made to the camera’s INCOM 1 line. $Camera control unit front panel 12 34 56 7 8 9: ; < = > ? @ CABLETALLY/CALLOPEN FUSE MAIN HEAD POWER 125V 5AFUSE LEVEL PGM PGM 1 SYSTEM PRIVATE MICON PTTOFF OFF PGM 2 250V 5A SHORT ALARM Camera Control Unit PUSH
5 Parts and their functions $Camera control unit rear panel ABC P QR STUVW X Y Z[ \ ^] L M NO 12 PUSH HD RET1 SDI INPUT SDI OUTPUT RET2 RET3 RET4 OUT1 OUT2 OUT3OUT4/PM Y / G Pb / B Pr / R PM HD OUTPUT SD RET1 SDI INPUT SDI OUTPUT RET2RET1 RET2PROMPTRET3 RET4 OUT1 OUT2 OUT3 OUT4 SD COMMUNICATION WFM1 IN RTS OUT CH–1CH–2DIGITAL AUDIOTRUNK WFM CONTROL AUXROPCSU / MSUALARM GNDMIC OUT WFM2 PM1 PM2 VBS1 VBS2 HD HD REFSD SD OUTPUT INPUT 1 2 SYNC OUTPUT SD REF AC IN FEGH IJK D ROP/MSU monitor selection SDTV WFM output R R G G B B RGB 3 waveforms SEQ Composite video ENC Pin No.Function Optical fiberPolarity Signal flow CAM#CCUCable color Yellow (01) 1 Optical fiberCCU#CAM Yellow (02) 2 Control wire, hotiCAM,.CCU Black 3 Control wire, coldjCAM,.CCU Red 4 AC 240 V liveiCCU#CAM Orange 5 AC 240 V neutraljCCU#CAM White 6 ESDTV digital return video 1, 2, 3, 4 input connectors [SDTV DIGITAL RET 1, 2, 3, 4] These connectors are for inputting the return video sig- nals of the SDTV serial digital interface. FSDTV D1 digital video output connectors [SDTV DIGITAL OUT D1 1, 2 3] These connectors are for outputting the D1 format video signals of the SDTV serial digital interface. There are 3 connectors (BNC). GAnalog return video 1, 2 input connectors [ANALOG RET 1, 2] These connectors (BNC) are for inputting the SD analog return video signals. HPROMPT-IN connectors [PROMPT1,2] These are the prompter signal input connectors (BNC). Input SDTV composite video signals as the prompter sig- nals. ISDTV waveform monitor output connectors [SDTV WFM 1, 2] These connectors (BNC) are for outputting the camera video signals which are to be displayed on the SDTV waveform monitor. BHDTV digital return video 1, 2, 3, 4 input connectors [HD DIGITAL RET 1, 2, 3, 4] (Option) These connectors (BNC) are for inputting the return video signals of the HDTV serial digital interface. CHDTV digital video 1, 2, 3, 4 output connectors [HD DIGITAL OUT 1, 2, 3, 4] (Option) These connectors (BNC) are for outputting the video sig- nals of the HDTV serial digital interface. DHDTV analog component video output connectors [HDTV ANALOG Y/G, Pb/B, Pr/R] (Option) The HDTV analog signals of the camera are output from these connectors (BNC). G/B/R or Y/Pb/Pr video signals can be selected by the master setup unit (MSU) or remote operation panel (ROP). SDTV PM output connector [PM] This is the HDTV PM output (1Vp-p) connector. AOptical fiber connector FXW.3K.93C.CLM made by LEMO
6 Parts and their functions JSDTV picture monitor video output connectors [PM 1, 2] These connectors (BNC) are for outputting the video signals which are to be displayed on the SDTV picture monitor. $Camera control unit rear panel ABC P QR STUVW X Y Z[ \ ^] L M NO 12 PUSH HD RET1 SDI INPUT SDI OUTPUT RET2 RET3 RET4 OUT1 OUT2 OUT3OUT4/PM Y / G Pb / B Pr / R PM HD OUTPUT SD RET1 SDI INPUT SDI OUTPUT RET2RET1 RET2PROMPTRET3 RET4 OUT1 OUT2 OUT3 OUT4 SD COMMUNICATION WFM1 IN RTS OUT CH–1CH–2DIGITAL AUDIOTRUNK WFM CONTROL AUXROPCSU / MSUALARM GNDMIC OUT WFM2 PM1 PM2 VBS1 VBS2 HD HD REFSD SD OUTPUT INPUT 1 2 SYNC OUTPUT SD REF AC IN FEGH IJK D ROP/MSU monitor selection SDTV PM1 output Rialarm display R Gialarm display G Bialarm display B Y and skin tone zebra pattern SEQ Composite video ENC KSDTV analog composite video output connectors [SDTV VBS] These connectors (BNC) are for outputting the SDTV ana- log composite video signals (with sync) of the camera. LHDTV analog SYNC output connector [HD SYNC] The HDTV analog sync signal of the camera is output from this connector (BNC). Its amplitude is +/-0.3 V (75h termination). MSDTV analog SYNC output connector [SDTV ANALOG SYNC] The SDTV analog sync signal of the camera is output from this connector (BNC). Its amplitude is 2 Vp-p (75h termination). NHDTV genlock input connectors [HD REF] These are the HDTV genlock input connectors (BNC). The bridging connection between the two connectors enables one to be used for input purposes and the other for output purposes. Input the HDTV tri-level sync signal as the genlock signal. OSDTV genlock input connectors [SDTV REF] These are the SDTV genlock input connectors (BNC). The bridging connection between the two connectors enables one to be used for input purposes and the other for output purposes. Input the BB video signal as the genlock signal.PINCOM/tally connector [COMMUNICATION] The external INCOM or tally system is connected here. INCOM/tally connector (JR25RK-24P made by Hirose ) Pin No. Function Polarity Signal flow 1 INCOM 1iCCU#SYSTEM 2 INCOM 1jCCU#SYSTEM 3 INCOM 1iSYSTEM#CCU 4 INCOM 1jSYSTEM#CCU 5NC 6 INCOM1 (Shield) CCU#SYSTEM 7NC 8 INCOM1 (Shield) SYSTEM#CCU 9 INCOM2 (Shield) CCU#SYSTEM 10 Red tally Contact 11 Tally common 12 Green tally Contact 13 NC 14 INCOM 2iCCU#SYSTEM 15 INCOM 2jCCU#SYSTEM 16 PGM2(H)iSYSTEM#CCU 17 PGM2(C)jSYSTEM#CCU 18 PGM1(Shield) SYSTEM#CCU 19 INCOM 2iSYSTEM#CCU 20 INCOM 2jSYSTEM#CCU 21 PGM2(Shield) SYSTEM#CCU 22 PGM1(H)iSYSTEM#CCU 23 PGM1(C)jSYSTEM#CCU 24 INCOM2 (Shield) SYSTEM#CCU PGM output level: 0 dBm/600h INCOM level: 0 dBm/600h
7 Parts and their functions S TMic 1, 2 output connectors [MIC OUT CH-1, CH-2] These are the microphone 1 analog output connectors of the camera. The microphone level is 0 dBm/600 h. Mic output connector (HA16RD-3P made by Hirose) UDigital audio output connector [DIGITAL AUDIO] This is the camera microphone 1 and 2 output connector (BNC) for AES/EBU digital audio interface specifications. QRTS input connector [RTS IN] The RTS system is connected to this connector. The microphone level is j4 dBm/200h. RTS input connector (HA16PRK-3S made by Hirose) Pin No. Function CommonPolarity Signal flow 1 Channel 1 (iDC) 2 Channel 2 3 Pin No. Function CommonPolarity Signal flow 1 Channel 1 (iDC) 2 Channel 2 3 RRTS output connector [RTS OUT] The unit is connected to the RTS system from this con- nector. The microphone level is j4 dBm/200h. RTS output connector (HA16RD-3P made by Hirose) Pin No. Function ShieldPolarity i jSignal flow CCU#SYSTEM CCU#SYSTEM 1 Hot 2 Cold 3 $Camera control unit rear panel ABC P QR STUVW X Y Z[ \ ^] L M NO 12 PUSH HD RET1 SDI INPUT SDI OUTPUT RET2 RET3 RET4 OUT1 OUT2 OUT3OUT4/PM Y / G Pb / B Pr / R PM HD OUTPUT SD RET1 SDI INPUT SDI OUTPUT RET2RET1 RET2PROMPTRET3 RET4 OUT1 OUT2 OUT3 OUT4 SD COMMUNICATION WFM1 IN RTS OUT CH–1CH–2DIGITAL AUDIOTRUNK WFM CONTROL AUXROPCSU / MSUALARM GNDMIC OUT WFM2 PM1 PM2 VBS1 VBS2 HD HD REFSD SD OUTPUT INPUT 1 2 SYNC OUTPUT SD REF AC IN FEGH IJK D VTRUNK connector [TRUNK] This connector enables two sets of RS-422 data to be transmitted. Pin No. Function TX (j)TRUNK number TRK 2Signal flow CAM#CCU 0 1 TX (i) TRK 3 2 RX (i) TRK 0 3 RX (j) TRK 1CCU#CAM 0 4 GND 5 RTS (j) RTS (i) CTS (i) CTS (j)TRK 6 TRK 7 TRK 4 TRK 5CAM#CCU 1 CCU#CAM 1 6 7 8 9
8 Parts and their functions $Camera control unit rear panel ABC P QR STUVW X Y Z[ \ ^] L M NO 12 PUSH HD RET1 SDI INPUT SDI OUTPUT RET2 RET3 RET4 OUT1 OUT2 OUT3OUT4/PM Y / G Pb / B Pr / R PM HD OUTPUT SD RET1 SDI INPUT SDI OUTPUT RET2RET1 RET2PROMPTRET3 RET4 OUT1 OUT2 OUT3 OUT4 SD COMMUNICATION WFM1 IN RTS OUT CH–1CH–2DIGITAL AUDIOTRUNK WFM CONTROL AUXROPCSU / MSUALARM GNDMIC OUT WFM2 PM1 PM2 VBS1 VBS2 HD HD REFSD SD OUTPUT INPUT 1 2 SYNC OUTPUT SD REF AC IN FEGH IJK D WWaveform monitor control connector [WFM CTL] This connector is used for controlling the waveform monitor. Since the interface is different, first check the WFM setting on the SYSTEM menu of the ROP or MSU before connect- ing the waveform monitor. Waveform monitor control connector (SDAB-9S made by Hirose) Pin No.Signal STAIRCASEFunction used by SDTV 10 V output/input channel switchingFunction used by HDTV 5 V pull-up, 110 k 1 RGB ENABLETTL level low when SEQ is selected by moni- tor selector switch on ROP or MSU, for parade display 2TTL level low THREE LINE OR FIELDOpen TTL level low when ENC.SEQ is selected by monitor selector switch on ROP or MSU 3 N.C. Not connected Not connected 4 CH1 OpenTTL level low when G or SEQ is selected by monitor selector switch on ROP or MSU 5 CH2 OpenTTL level low when B or SEQ is selected by monitor selector switch on ROP or MSU 6 CH3 OpenTTL level low when R or SEQ is selected by monitor selector switch on ROP or MSU 7 N.C. Not connected Not connected 8 GND GND GND 9 XAUX connector [AUX] This connector is for establishing the down-converter mode from the external system by remote control. Side panel, squeeze and letter-box are available as the down-converter modes. AUX connector (SDAB-9S made by Hirose) Pin No. Signal GNDFunction 1 MODE2 When shorted: 4:3 aspect ratio When open: 16:9 aspect ratio 2 MODE2 MODE1 MODE1 N.C. TALLY R TALLY G TALLY COMRefer to table below for the down converter mode. Contact Contact 3 4 5 6 7 8 9 Down-converter mode MODE1 MODE2 OPEN OPEN MAKE MAKE OPEN MAKE OPEN MAKE LOCAL Letter-box (LB) Squeeze (SQ) Side panel (SP)
9 [Fan This dissipates the heat generated inside the CCU to keep the unit cool. ZCSU/MSN connector The camera selector unit (CSU) is connected to this con- nector. CSU connector (HR10A-10R-10S made by Hirose) Parts and their functions $Camera control unit rear panel ABC P QR STUVW X Y Z[ \ ^] L M NO 12 PUSH HD RET1 SDI INPUT SDI OUTPUT RET2 RET3 RET4 OUT1 OUT2 OUT3OUT4/PM Y / G Pb / B Pr / R PM HD OUTPUT SD RET1 SDI INPUT SDI OUTPUT RET2RET1 RET2PROMPTRET3 RET4 OUT1 OUT2 OUT3 OUT4 SD COMMUNICATION WFM1 IN RTS OUT CH–1CH–2DIGITAL AUDIOTRUNK WFM CONTROL AUXROPCSU / MSUALARM GNDMIC OUT WFM2 PM1 PM2 VBS1 VBS2 HD HD REFSD SD OUTPUT INPUT 1 2 SYNC OUTPUT SD REF AC IN FEGH IJK D YROP connector The remote operation panel (ROP) is connected to this connector. ROP connector (HR10A-10R-10S) Pin No. Function ROP CONT (H)Polarity iSignal flow CCU#ROP 1 ROP CONT (C)jCCU#ROP 2 ROP DATA (H)iROP#CCU 3 ROP DATA (C)jROP#CCU 4 POW REM/CD ACCU#ROP 5 INCOMT/CD B INCOMR/CD C INCOMG/CD D i12V GNDiCCU#ROP CCU#ROP CCU#ROP CCU#ROP 6 7 8 9 10Pin No. Function CSU DATA (H)Polarity iSignal flow CCU#CSU 1 CSU DATA (C)jCCU#CSU 2CSU CONT (H) iCSU#CCU 3CSU CONT (C) jCSU#CCU 4 TALLY RCCU#CSU 5 TALLY G HEAD POWER ALARM 1 ALARM 0 GNDCCU#CSU CCU#CSU CCU#CSU CCU#CSU 6 7 8 9 10
10 Parts and their functions $Camera control unit rear panel ABC P QR STUVW X Y Z[ \ ^] L M NO 12 PUSH HD RET1 SDI INPUT SDI OUTPUT RET2 RET3 RET4 OUT1 OUT2 OUT3OUT4/PM Y / G Pb / B Pr / R PM HD OUTPUT SD RET1 SDI INPUT SDI OUTPUT RET2RET1 RET2PROMPTRET3 RET4 OUT1 OUT2 OUT3 OUT4 SD COMMUNICATION WFM1 IN RTS OUT CH–1CH–2DIGITAL AUDIOTRUNK WFM CONTROL AUXROPCSU / MSUALARM GNDMIC OUT WFM2 PM1 PM2 VBS1 VBS2 HD HD REFSD SD OUTPUT INPUT 1 2 SYNC OUTPUT SD REF AC IN FEGH IJK D ]AC inlet [AC IN] AC 120 V, 50/60 Hz ^Ground terminal [GND] \Alarm connector [ALARM] This connector is for outputting the alarm signals to the external system when any problem with the supply volt- age has occurred inside the CCU or the CCU fan has stopped. When the power supplied to the AC fan or DC fan inside the CCU has been shut down, pins 3 and 4 of this con- nector are shorted. If power is supplied to the CCU and any of the DC power supplies inside the CCU fails to output the supply voltage, it means that pins 1 and 2 of this connector are shorted. Alarm connector (RM-12BRB-4PH made by Hirose) Pin No. Function POWER ALARM (H) 1 POWER ALARM (L) 2 FAN ALARM (H) 3 FAN ALARM (L) 4 1. Turn off the power of CCU. 2. Turn the knobs and remove the front panel. 3. Switch the SW281 (MODE SW) on the Control board as follows: ≥The factory setting is “720p camera”. 4. Install the front panel, and turn on the power to complete setting. CABLETALLY/CALLOPEN FUSE MAIN HEAD POWER 125V 5AFUSE LEVEL PGM PGM 1 SYSTEM PRIVATE MICON PTTOFF OFF PGM 2 250V 5ASHORT ALARM Camera Control Unit PUSH CABLETALLY/CALLOPEN FUSE MAIN HEAD POWER 125V 5AFUSE LEVEL PGM PGM 1 SYSTEM PRIVATE MICON PTTOFF OFF PGM 2 250V 5ASHORT ALARM PUSH 1 2 3 4 5 6 7 8O N Knobs Power switch Front panel Control board SW281 (MODE SW) $How to switch between 1080i camera mode and 720p camera mode 1 2 3 4 5 6 7 8O N1 2 3 4 5 6 7 8O N 1080i camera 720p camera