Panasonic BLC1A_20A Owners Manual
Have a look at the manual Panasonic BLC1A_20A Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Operating Instructions [For assistance, please call: 1-800-272-7033] 51 3.Click [Save] when finished. The new settings are saved. When finished, Success! is displayed. 4.Click [Go to Camera page]. The Camera page is displayed. White BalanceSelect from the following options. Auto (default)—Automatic adjustment Fixed Indoor—Electric bulb (2800 K) Fixed Fluorescent (White)—White (3600 K) Fixed Fluorescent (Daylight)—Daylight (4000 K) Fixed Outdoor—Solar light (6000 K) Note The kelvin (symbol: K) is the standard unit for color temperature. AC Power Source Frequency This setting may correct flickering caused by power line frequency. – 60 Hz (default) –50 Hz Select 60 Hz in the United States. Color Night View In the color night view mode, the camera image becomes brighter in a low illuminance. The camera image returns to normal operation in a bright location. If you enable the color night view mode, refresh interval may increase. Subjects that are moving in low illumination may be blurred, not distinguished, or not displayed. Note When the camera transmits a dark scene, the camera image may become white, or horizontal lines may be displayed on the screen. This is one of the characteristics of a CMOS sensor. This is not a malfunction. Setting Description
Operating Instructions 52 3 Registering Users 3.1 Changing the Authentication Setting and Administrator User Name and Password The Security: Administrator page allows you to change authentication, and the administrators user name and password. An authentication window allows registered users to access the camera. Note If you access the camera for the first time, the window for setting the administrators user name and password is displayed. Make a note of the user name and password so that you will not forget them. The user name and password should be secured at your own responsibility. Pay attention to the following points. – Set a user name and password with as many characters as possible. – Change the password regularly. Setting [Permit access from guest users] (permitting access without a User Name or Password) or [Permit access from guest users (mobile only)] (permitting access without a User Name or Password) at General Authentication risks the images being viewed by third parties. Control the contents of the images accordingly. IMPORTANT It is important to limit access to the camera by use of a unique User Name and a secret Password. Because the camera is accessed through the Internet it is possible that the camera could be accessed by unknown individuals, including those who are commonly known as crackers to whom you do not want to allow access. The use of a unique User Name and a Password known only to you will help insure that only authorized individuals are given access to the camera. You have the option of proceeding without a User Name and Password, but it is strongly recommended that you utilize these protections. 1.Click [Administrator] on the Setup page.
Operating Instructions [For assistance, please call: 1-800-272-7033] 53 2.Set each parameter. Clicking [Cancel] cancels your settings without saving changes. SettingDescription General AuthenticationAuthentication has 3 phases. If you set [Permit access from guest users], the camera does not display the authentication window in camera access. All guest users can view images without a user name and password. Note If you set [Permit access from guest users], [Login] tab is displayed at the top of the page. After you log in as an administrator (see page 56), the Setup page and the Maintenance page can be accessed. If you set [Permit access from guest users (mobile only)], an authentication window is not displayed even if you access the cell phone page. All guest users can view images without a user name and password. If you set [Do not permit access from guest users], an authentication window is displayed to access the camera. Users must enter the user name and password.
Operating Instructions 54 Note When setting authentication, set the user name and password, and save them. When users other than an administrator are accessing the camera, the [Setup] and [Maintenance] tabs will not be displayed. The user name and password are case sensitive. For information on [CGI interface], see page 97. 3.Click [Save] when finished. The new settings are saved. When finished, Success! is displayed. 4.Click [Go to Security: Administrator page]. The Security: Administrator page is displayed. Note When the user name and password have been changed, the camera displays an authentication window. Enter the user name and password, and click [OK]. User Name/ Password User Name (6 to 15 characters): Enter the user name. Password (6 to 15 characters): Enter the password. Note The password must be different from the user name. Retype Password: Reenter the password. Enter ASCII characters (see page 132). Note that [Space], [], [], [&], [] and [:] are not available. Setting Description
Operating Instructions [For assistance, please call: 1-800-272-7033] 55 Administrator/General Users/Guest Users The camera has 3 user levels (administrator, general users and guest users). Note Guest users mean unregistered users. Set [Permit access from guest users] or [Permit access from guest users (mobile only)] on the Security: Administrator page (see page 52) to allow access from guest users. ItemsAdministratorGeneral UsersGuest Users User Name and PasswordRequiredRequiredNot Required Number of Users150— Accessible PagesAll PagesPages Except For Setup and Maintenance pagePages Except For Setup and Maintenance page Access LevelAll OperationsAccess level can be set for each general user (see page 57). Access level can be set for guest users (see page 57).
Operating Instructions 56 3.2 Logging in to the Camera If you set [Permit access from guest users] on the Security: Administrator page, [Login] tab is displayed at the top of the page. After you log in as an administrator, the Setup page and the Maintenance page can be accessed. 1.Click [Login] tab at the top of the page. 2.Check a login mode, and click [Login]. Note The authentication window is displayed. Enter the user name and password set for General Users or Administrator. 3.Enter a valid user name and password according to the Login mode selected in step 2, and click [OK].
Operating Instructions [For assistance, please call: 1-800-272-7033] 57 3.3 Creating, Modifying or Deleting General Users The General User page allows you to create, modify or delete general users. Up to 50 general users can be registered. The access level is set for each general user. If you set [Permit access from guest users] or [Permit access from guest users (mobile only)] on the Security: Administrator page, the access level can be set for guest users. Note For general users, the Setup and Maintenance tabs are not displayed. 1.Click [General User] on the Setup page. 2.To create a general user, click [Create]. When setting [Do not permit access from guest users] When setting [Permit access from guest users] or [Permit access from guest users (mobile only)] To change the settings of general users or guest users, select their name and click [Modify]. The modification page is displayed. To delete a general user, select the name and click [Delete]. The confirmation page is displayed.
Operating Instructions 58 3.Set each parameter. 4.Click [Save] when finished. The new settings are saved. When finished, Success! is displayed. 5.Click [Go to General User page]. The General User page is displayed. Settings for general users Settings for guest users Clicking [Cancel] takes you back to the previous page without saving changes. SettingDescription User ID List Up to 50 general users can be registered. The list is used to modify or delete general user settings. User Name/ Password User Name (6 to 15 characters): Enter the user name. Password (6 to 15 characters): Enter the password. Note The password must be different from the user name. Retype Password: Reenter the password. Enter ASCII characters (see page 132). Note that [Space], [], [], [&], [] and [:] are not available. Access LevelAn access level is set for each general user. Level 1 : Only the camera images can be viewed. Level 2 : The camera images can be viewed and the brightness can be adjusted.
Operating Instructions [For assistance, please call: 1-800-272-7033] 59 4 Buffering or Transferring Images 4.1 Procedures of Buffering or Transferring Images The procedures from this page to page 70 are described about settings of the image buffer or transfer. See the procedures below to understand the general outline of the settings. Transfer Method (Select one from the lists.) No Transfer, No Memory Overwrite No Transfer, Memory Overwrite FTP E-mailTransfer Method (Select one from the lists.) No Transfer, No Memory Overwrite No Transfer, Memory Overwrite FTP E-mail Time Setting Image Setting Image Buffer Frequency SettingTime Setting Image Setting Image Buffer Frequency Setting Save the settings to complete. Buffer/Transfer by Timer (Page 60) Save the settings to complete.Buffer/Transfer by Motion Detection Signal (Page 70) E-mail Notification When Triggered Setting Changing Motion Detection Sensitivity (Page 83) Notifying the Sensor Log (Page 86)
Operating Instructions 60 4.2 Buffering or Transferring Images by Timer The Trigger page allows you to enable image buffer/transfer by E-mail or FTP. 1.Click [Trigger] on the Setup page. 2.Click a No. to enable buffer/transfer. 3.Check [Enable Image Buffer/Transfer], and select [Timer] for the trigger, and click [Next>]. Note Click [Delete Buffered Images] to delete images already buffered. Click [Save] to save the settings. The buffered images will be deleted. Clicking [Cancel] takes you back to the Trigger page without saving changes. SettingDescription Enable Image Buffer/Transfer Check the box to enable the Trigger setting. Uncheck the box to disable it.