    8
    8-4-6 MODE CHECK IND 8-4-7  !LED
    
    If both GAIN (0 dB) and GAIN (–3 dB) are set to ON, the LED
    illuminates except when GAIN is adjusted to 0 dB and –3 dB. 
    The ____ in the Adjustable Range column indicates the preset
    mode. 
    Items/
    Data Saved Adjustable 
    Range Remarks 
    STATUS ONOFFSelect whether or not to display the status 
    indication during MODE CHECK. 
    –CUFE
    !LED ONOFFSelect whether or not to display the cause 
    indication screen when the ! LED turns on 
    during MODE CHECK 
    –CUFE
    FUNCTION ONOFFSelect whether or not to display the 
    FUNCTION indication screen during MODE 
    CHECK. 
    –CUFE
    AU D I O O NOFFSelect whether or not to display the AUDIO 
    indication screen during MODE CHECK. 
    –CUFE
    P.ON IND ONOFFSelect whether or not to display the status 
    indication screen after the power is turned 
    ON. 
    –CUFE
    Items/
    Data Saved Adjustable 
    Range Remarks
    GAIN(0dB) ONOFFSelect whether or not to illuminate when 
    GAIN is set to other than 0 dB.
    –CUFE
    GAIN (-3dB) ON
    OFFSelect whether or not to illuminate when 
    GAIN is set to other than -3 dB.
    –CUFE
    DS.GAIN ON
    OFFSelect whether or not to illuminate when 
    DS.GAIN (storage gain) is ON. 
    –CUFE
    SHUTTER ONOFFSelect whether or not to illuminate when the 
    shutter is set to ON. 
    –CUFE
    WHITE 
    PRESETON
    OFFSelect whether or not to illuminate when the 
    WHITE BAL switch is set to PRST. 
    –CUFE
    EXTENDER ONOFFSelect whether or not to illuminate when the 
    lens is in EXTENDER mode. 
    –CUFE
    BLACK STR ON
    OFFSelect whether or not to illuminate when 
    BLACK STRETCH is used. 
    –CUFE
    MATRIX ON
    OFFSelect whether or not to illuminate when 
    MATRIX is set to ON. 
    –CUFE
    COLOR 
    CORRECTIONON
    OFFSelect whether or not to illuminate when 
    COLOR CORRECTION is set to ON. 
    –CUFE
    FILTER ON
    OFFSelect whether or not to illuminate the lamp 
    when filter1 (3200K) is not 3200K.
    –CUFE
    SUPER V ON
    OFFSelect whether or not to illuminate when 
    SUPER V is set to ON. 
    –CUFE
    50M/25M/DV OFFW/O 50M
    W/O 25M
    W/O DVSelect whether or not to illuminate according 
    to the recording mode. 
    OFF:Does not illuminate in any recording 
    mode. 
    W/O 50M:
    Illuminate except in DVCPRO50 
    mode. 
    W/O 25M:
    llluminate except in DVCPRO mode. 
    W/O DV:
    Illuminate except in DV mode. 
    –CUFE
    AT W
    ON
    OFFSelect whether or not to illuminate when 
    auto-tracking white balance is allocated to 
    the WHITE BAL switch B. 
    –CUFE
    D.ZOOM ON
    OFFSelect whether or not to illuminate during 
    digital zoom operation. 
    –CUFE 
    						
    							102
    8-5 CAM OPERATION
    8-5-1 CAMERA ID
    
    This setting is canceled when READ FACTORY DATA is
    selected. 
    8-5-2 SHUTTER SPEED8-5-3 SHUTTER SELECT
    The ____ in the Adjustable Range column indicates the preset
    mode. 
    Items/
    Data Saved Adjustable 
    Range Remarks 
    ID1Setting 1 for the CAMERA ID recorded on 
    color bars. Up to 10 characters are allowed 
    for this setting.
    –CUF –
    ID2Setting 2 for the CAMERA ID recorded on 
    color bars. Up to 10 characters are allowed 
    for this setting.
    –CUF –
    ID3Setting 3 for the CAMERA ID recorded on 
    color bars. Up to 10 characters are allowed 
    for this setting.
    –CUF –
    Items/
    Data Saved Adjustable 
    Range Remarks 
    SYNCHRO 
    SCANONOFFAllocate SYNCHRO SCAN as a shutter 
    speed selectable by the shutter switch. 
    –CUFE
    SUPER V ON
    OFFAllocate SUPER V as a shutter speed 
    selectable by the shutter switch. 
    –CUFE
    POSITION1 ONOFFAllocate the shutter speed set by POSITION 
    SELECT in the  
    screen as the shutter speed selectable by 
    the shutter switch. 
    –CUFE
    POSITION2 ONOFFAllocate the shutter speed set by 
    POSITION2 SELECT in the  screen as the shutter speed 
    selectable by the shutter switch. 
    –CUFE
    POSITION3 ONOFFAllocate the shutter speed set by 
    POSITION3 SELECT in the  screen as the shutter speed 
    selectable by the shutter switch. 
    –CUFE
    POSITION4 ONOFFAllocate the shutter speed set by 
    POSITION4 SELECT in the  screen as the shutter speed 
    selectable by the shutter switch. 
    –CUFE
    POSITION5 ONOFFAllocate the shutter speed set by 
    POSITION5 SELECT in the  screen as the shutter speed 
    selectable by the shutter switch. 
    –CUFE
    POSITION6 ONOFFAllocate the shutter speed set by 
    POSITION6 SELECT in the  screen as the shutter speed 
    selectable by the shutter switch. 
    –CUFE
    Items/
    Data Saved Adjustable 
    Range Remarks
    SUPER V 
    MODEFRM1FRM2Select the SUPER V switching mode. 
    FRM1: Normal mode. 
    FRM2: After-image reduction mode. 
    
    The SUPER V mode increases vertical 
    resolution by directly outputting the photo-
    diode vertical signal from the CCD. FRM1 
    sets the accumulation level to 1/30th 
    second. FRM sets the level to 1/60th 
    second, reducing sensitivity by half. 
    –CUFE
    POSITION1 
    SEL1/1001/120
    1/250
    1/500
    1/1000
    1/2000Select the shutter speed to be allocated to 
    POSITION1. 
    –CUFE
    POSITION2 
    SEL1/100
    1/120
    1/250
    1/500
    1/1000
    1/2000
    Select the shutter speed to be allocated to 
    POSITION2. 
    –CUFE
    POSITION3 
    SEL1/100
    1/120
    1/250
    1/500
    1/1000
    1/2000
    Select the shutter speed to be allocated to 
    POSITION3. 
    –CUFE
    POSITION4 
    SEL1/100
    1/120
    1/250
    1/500
    1/1000
    1/2000
    Select the shutter speed to be allocated to 
    POSITION4. 
    –CUFE
    POSITION5 
    SEL1/100
    1/120
    1/250
    1/500
    1/1000
    1/2000
    Select the shutter speed to be allocated to 
    POSITION5. 
    –CUFE
    POSITION6 
    SEL1/100
    1/120
    1/250
    1/500
    1/1000
    1/2000Select the shutter speed to be allocated to 
    POSITION6. 
    –CUFE 
    						
    							103
    8
    8-5-4 USER SW
    
    For each function of the USER switches, refer to [4-9-4
    Assigning Functions to USER MAIN, USER1 and USER2
    Buttons].
    8-5-5 SW MODE
    The ____ in the Adjustable Range column indicates the preset
    mode. 
    Items/
    Data Saved Adjustable 
    Range Remarks 
    USER MAIN SW INH
    S.GAIN
    DS.GAIN
    S.IRIS
    I.OVR
    S.BLK
    B.STR
    D. Z O O M
    AT W
    Y GET
    NEWS-G.
    AUD IO  CH 1
    AUD IO  CH 2
    REC SW
    RET SW
    SLOT SELAllocate the USER MAIN button. 
    –CUFE
    USER1 SW INH
    S.GAIN
    DS.GAIN
    S.IRIS
    I.OVR
    S.BLK
    B.STR
    D. Z O O M
    AT W
    Y GET
    NEWS-G.
    AUD IO  CH 1
    AUD IO  CH 2
    REC SW
    RET SW
    SLOT SEL
    Allocate the USER1 button. 
    –CUFE
    USER2 SW INH
    S.GAIN
    DS.GAIN
    S.IRIS
    I.OVR
    S.BLK
    B.STR
    D. Z O O M
    AT W
    Y GET
    NEWS-G.
    AUD IO  CH 1
    AUD IO  CH 2
    REC SW
    RET SW
    SLOT SEL
    Allocate the USER2 button. 
    –CUFE
    Items/
    Data Saved Adjustable 
    Range Remarks
    RET SW RECCHECKCAM RET
    Select the RET switch function. 
    REC CHECK:
     Perform REC REVIEW. 
    CAM RET:
     Perform return signal output. 
    –CUFE
    S.BLK LVL OFF
    –10
    –20
    –30
    Set the super black level. 
    –CUFE
    AUTO KNEE 
    SWONOFFSelect whether or not to use the AUTO 
    KNEE switch. 
    SCUF E
    SHD,ABB SW 
    CTLONOFFSelect whether or not to enable the 
    automatic black shading adjustment if the 
    ABB switch has been pressed for 5 seconds 
    or more. 
    –CUFE
    COLOR BARS SMPTEFULL
    BARS
    SPLIT
    ARIBSelect the color bars to use. 
    SMPTE:Use the SMPTE color bars. 
    FULL BARS:Use full color bars. 
    SPLIT:Use SPLIT color bars. 
    ARIB:Use ARIB multi-format color 
    bars. 
    –CUFE
    S.GAIN OFF L/M/HS.GAINSelect when the SUPER GAIN mode is 
    disabled. 
    L/M/H:Disabled when the gain selector 
    switch is operated. 
    S.GAIN:Disabled only with the S.GAIN switch 
    (USER button). 
    –CUFE
    DS.GAIN OFF L/M/H
    DS.GAINSelect when the DIGITAL SUPER GAIN 
    mode (stored gain) is disabled. 
    L/M/H:Disabled when the gain selector 
    switch is operated. 
    S.GAIN:Disabled only with the S.GAIN switch 
    (USER button). 
    –CUFE
    ECU DATA 
    SAVEON
    OFFON:Store the values set and adjusted 
    with the ECU when the ECU is 
    disconnected from the camera-
    recorder. 
    OFF:Does not store camera-related set 
    values. 
    –CUF –
    ECU REC CHK 
    SWR.REVIEWPLAYSelect the camera-recorder operation to be 
    performed when the ECU REC CHECK 
    button is pressed.
    R.REVIEW:Perform REC REVIEW. 
    PLAY:Play back the most-recently 
    recorded clip from the beginning. 
    –CUFE 
    						
    							104
    8-5-6 WHITE BALANCE MODE 8-5-7 USER SW GAIN
    The ____ in the Adjustable Range column indicates the preset
    mode. 
    Items/
    Data Saved Adjustable 
    Range Remarks 
    FILTER INH ONOFFSelect whether or not to retain white balance 
    memory (A/B) data for individual filters. 
    ON:Retain data in the A/B memory (2 
    memory areas) regardless of the 
    filters. 
    OFF:Retain data for individual filters. 
    –CUFE
    SHOCKLESS 
    AW BOFF
    FA S T
    NORMAL
    SLOW1
    SLOW2
    SLOW3
    Set SHOCKLESS AWB to ON (FAST/
    NORMAL/SLOW1-3) or OFF. 
    SHOCKLESS AWB eliminates the shock 
    caused by switching the WHITE BAL 
    switch’s PRST/A/B setting. The switching 
    time can also be selected. 
    –CUFE
    AWB AREA 25%50%
    90%Switch the AWB detection area. 
    25%:Detect 25% of area around the 
    screen center. 
    50%:Detect 50% of area around the 
    screen center. 
    90%:Detect 90% of area in the full screen. 
    –CUFE
    AWB & ABB 
    OFFSETON
    OFFSelect whether or not to reset the GAIN and 
    PED values in the ROP menu when AWB 
    and ABB are executed. 
    ON:Do not reset. 
    OFF:Reset values. 
    –CUFE
    COLOR TEMP 
    PRE3200K : 5600K
    Set the AWB PRE color temperature. 
    –CUFE
    AW B A ME MVA RSelect the function to be allocated to WHITE 
    BAL switch A. 
    MEM:Function to store values set by 
    executing the auto white balance. 
    VAR:Function to apply color temperature 
    set by COLOR TEMP A. 
    –CUFE
    COLOR TEMP 
    A3200K : 5600K
    Set the color temperature when VAR is 
    selected under AWB A. 
    –CUFE
    AW B B ME MAT W
    VA RSelect the function to be allocated to WHITE 
    BAL switch B. 
    MEM:Function to store values set by 
    executing auto white balance. 
    AT W :Function to execute auto-tracking 
    white balance. 
    VAR:Function to apply color temperature 
    set by COLOR TEMP B. 
    –CUFE
    COLOR TEMP 
    B3200K : 5600K
    Set the color temperature when VAR is 
    selected under AWB B. 
    –CUFE
    ATW SPEED NORMALSLOW
    FA S TSelect the control speed for the auto-
    tracking white balance. 
    –CUFE
    Items/
    Data Saved Adjustable 
    Range Remarks
    S.GAIN
    30 dB_•Select whether or not to enable 30dB for 
    SUPER GAIN. 
    _: Enable. 
     • :  Disable. 
    –CUFE
    36 dB_•Select whether or not to enable 36dB for 
    SUPER GAIN. 
    _: Enable. 
     • :  Disable. 
    –CUFE
    42 dB_•Select whether or not to enable 42dB for 
    SUPER GAIN. 
    _: Enable. 
     • :  Disable. 
    –CUFE
    48 dB_•Select whether or not to enable 48dB for 
    SUPER GAIN. 
    _: Enable. 
     • :  Disable. 
    –CUFE
    DS.GAIN
    6 dB(1/30)
    _•Select whether or not to enable 6 dB (1/30) 
    for DS.GAIN. 
    _: Enable. 
     • :  Disable. 
    –CUFE
    12 dB(1/15)_•Select whether or not to enable 12 dB (1/15) 
    for DS.GAIN. 
    _: Enable. 
     • :  Disable. 
    –CUFE
    20 dB(1/6)_•Select whether or not to enable 20 dB (1/6) 
    for DS.GAIN. 
    _: Enable. 
     • :  Disable. 
    –CUFE 
    						
    							105
    8
    8-5-8 IRIS
    8-6 MAIN OPERATION
    8-6-1 BATTERY/P2CARD
    The ____ in the Adjustable Range column indicates the preset
    mode. 
    Items/
    Data Saved Adjustable 
    Range Remarks 
    A.IRIS LEVEL 000 : 050 : 100
    Set the target value for auto iris. 
    –CUFE
    A.IRIS PEAK/
    AV E000 : 040 : 100
    Determine the peak-to-standard ratio for the 
    auto iris. 
    A larger value sets the auto iris to respond to 
    the peak in the IRIS detection window, while 
    a smaller value sets it to respond to the 
    average value in the window. 
    –CUFE
    A.IRIS MODE NORM1
    NORM2
    CENTR
    Select the auto iris detection window. NORM1:The window closer to the center of 
    the screen. 
    NORM2:The window closer to bottom of the 
    screen. 
    CENTR:The spot window in the center of the 
    screen.  –CUFE
    S.IRIS LEVEL 000 : 080 : 100
    Set the target value for the super iris. 
    –CUFE
    IRIS GAIN CAM
    LENSSelect which unit controls IRIS GAIN. 
    
    Lenses with an extender, such asC2, C0.8 
    sold before FUJINON DIGI POWER, 
    perform IRIS compensation while enabling 
    the extender. Therefore, if this setting is 
    switched to CAM, the camera’s iris control 
    will not operate properly. 
    –CUFE
    IRIS GAIN 
    VA L U E01 : 08 : 20
    Set the adjustable value for IRIS GAIN. This 
    setting is effective when CAM is selected for 
    IRIS GAIN. 
    –CUFE
    Items/
    Data Saved Adjustable 
    Range Remarks
    BATTERY 
    SELECTPRO14TRIM14
    HYTRN50
    HYTRN100
    HYTRN120
    DIONIC90
    DIONIC160
    HP-90L
    BP-H120
    NP-L50
    ENDURA50
    ENDURA80
    BP-L60/90
    NiCd14
    NiCd13
    NiCd12
    TYPE A
    TYPE BSelect the battery to use. Remaining 
    capacity detection is also performed 
    according to the selected battery. 
    The selectable battery types change 
    depending on the settings under [8-6-2 
    BATTERY SETTING1] and [8-6-3 BATTERY 
    SETTING2]. 
    –CUF –
    EXT DC IN 
    SELECTAC _ AD PTPRO14
    TRIM14
    HYTRN50
    HYTRN100
    HYTRN120
    DIONIC90
    DIONIC160
    HP-90L
    BP-H120
    NP-L50
    ENDURA50
    ENDURA80
    BP-L60/90
    NiCd14
    NiCd13
    NiCd12
    TYPE A
    TYPE BSet the remaining capacity detection type 
    when a battery is connected to the DC IN 
    connector. Remaining capacity detection is 
    also performed according to the selected 
    battery type. 
    The selectable battery types change 
    depending on the settings under [8-6-2 
    BATTERY SETTING1] and [8-6-3 BATTERY 
    SETTING2]. 
    
    The % display is disabled even when a 
    digital battery is connected to the DC IN 
    connector. 
    –CUF –
    BATT NEAR 
    END ALARMON
    OFFSelect whether or not to set the alarm to 
    beep for BATT NEAR END ALARM. 
    –CUF –
    BATT NEAR 
    END CANCELONOFFIf set to ON, the warning tone and indication 
    can be canceled by pressing the MODE 
    CHECK button when BATT NEAR END 
    ALARM is triggered. 
    –CUF –
    BATT END 
    ALARMONOFFSelect whether or not to set the alarm to 
    beep for BATT END ALARM. 
    –CUF –
    BATT REMAIN 
    FULL100%
    70%Set the display content of the remaining 
    battery capacity indicator bars in the display 
    window when using a digital battery. 
    100%: Indicate FULL at 100% capacity. 
    70%: Indicate FULL at 70% capacity. 
    –CUF – 
    						
    							106
    8-6-2 BATTERY SETTING1
    The ____ in the Adjustable Range column indicates the preset
    mode. 
    Items/
    Data Saved Adjustable 
    Range Remarks 
    CARD NEAR 
    END ALARMON
    OFFSelect whether or not to set the alarm to 
    beep for P2 CARD NEAR END ALARM. 
    –CUF –
    CARD NEAR 
    END TIME 3min
    2minSet the remaining time to indicate the P2 
    CARD NEAR END TIME alarm. 
    –CUF –
    CARD END 
    ALARMONOFFSelect whether or not to set the alarm to 
    beep for P2 CARD END ALARM. 
    –CUF –
    CARD REMAIN/„5min/„3min/„Set the length of time for one segment („) of 
    the P2 card’s remaining capacity indicator 
    bars. 
    5min:One segment represents 5 minutes. 
    3min:One segment represents 3 minutes. 
    –CUF –
    Items/
    Data Saved Adjustable 
    Range Remarks
    PRO14_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AU TOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO :Set voltage automatically. 
    MANUAL:Set voltage manually. 11.0 : 13.7 : 15.0
    When MANUAL is selected in the above 
    menu, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF –
    TRIM14_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AU TOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO :Set voltage automatically. 
    MANUAL:Set voltage manually. 11.0 : 13.6 : 15.0
    When MANUAL is selected in the menu 
    above, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF –
    HYTRON50_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AU TOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO :Set voltage automatically. 
    MANUAL:Set voltage manually. 11.0 : 13.1 : 15.0
    When MANUAL is selected in the menu 
    above, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF –
    HYTRON100_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AU TOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO :Set voltage automatically. 
    MANUAL:Set voltage manually. 11.0 : 13.2 : 15.0
    When MANUAL is selected in the menu 
    above, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF –
    HYTRON120_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AU TOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO :Set voltage automatically. 
    MANUAL:Set voltage manually. 11.0 : 13.1 : 15.0
    When MANUAL is selected in the menu 
    above, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF – 
    						
    							107
    8
    
    The remaining battery capacity for digital batteries is displayed
    as % inside the viewfinder (PRO14/TRIM14/HYTRON50/
    HYTRON100/HYTRON120/DIONIC90/DIONIC160/NP-L50). 
    The BATT NEAR END alarm, however, is triggered according to
    the setting on the  screen, regardless of
    the % indication. 
    The ____ in the Adjustable Range column indicates the preset
    mode.
    Items/
    Data Saved Adjustable 
    Range Remarks 
    DIONIC90_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AUTOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO:Set voltage automatically. 
    MANUAL:Set voltage manually. 
    11.0 : 13.6 : 15.0
    When MANUAL is selected in the menu 
    above, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF –
     DIONIC160_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AUTOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO:Set voltage automatically. 
    MANUAL:Set voltage manually. 11.0 : 13.3 : 15.0
    When MANUAL is selected in the menu 
    above, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF –
    HP-90L_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AUTOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO:Set voltage automatically. 
    MANUAL:Set voltage manually. 
    11.0 : 12.4 : 15.0
    When MANUAL is selected in the menu 
    above, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF –
    BP-H120_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AUTOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO:Set voltage automatically. 
    MANUAL:Set voltage manually. 11.0 : 11.5 : 15.0
    When MANUAL is selected in the menu 
    above, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF –
    NP-L50_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AUTOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO:Set voltage automatically. 
    MANUAL:Set voltage manually. 
    11.0 : 13.0 : 15.0
    When MANUAL is selected in the menu 
    above, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF –
    Items/
    Data Saved Adjustable 
    Range Remarks
    ENDURA50_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AU TOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO :Set voltage automatically. 
    MANUAL:Set voltage manually. 
    11.0 : 13.1 : 15.0
    When MANUAL is selected in the menu 
    above, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF –
    ENDURA80_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AU TOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO :Set voltage automatically. 
    MANUAL:Set voltage manually. 11.0 : 13.1 : 15.0
    When MANUAL is selected in the menu 
    above, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF –
    BP-L60/90_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    AU TOMANUALSelect auto or manual to set the NEAR END 
    voltage. 
    AU TO :Set voltage automatically. 
    MANUAL:Set voltage manually. 
    11.0 : 11.2 : 15.0
    When MANUAL is selected in the menu 
    above, set the NEAR END voltage in 0.1 V 
    steps. 
    –CUF – 
    						
    							108
    8-6-3 BATTERY SETTING2
    The ____ in the Adjustable Range column indicates the preset
    mode.
    Items/
    Data Saved Adjustable 
    Range Remarks 
    NiCd14_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    NEAR END 11.0 : 13.6 : 15.0
    Set the NEAR END voltage in 0.1 V steps. 
    END
    11.0 : 13.2 : 15.0
    When MANUAL is selected in the menu 
    above, set the END voltage in 0.1 V steps. 
    –CUF –
    NiCd13_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    NEAR END 11.0 : 12.7 : 15.0
    Set the NEAR END voltage in 0.1 V steps. 
    END
    11.0 : 12.2 : 15.0
    When MANUAL is selected in the menu 
    above, set the END voltage in 0.1 V steps. 
    –CUF –
    NiCd12_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    NEAR END 11.0 : 11.5 : 15.0
    Set the NEAR END voltage in 0.1 V steps. 
    END
    11.0 : 11.2 : 15.0
    When MANUAL is selected in the menu 
    above, set the END voltage in 0.1 V steps. 
    –CUF –
    TYPE A_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    FULL 12.0 : 15.0 : 17.0
    Set the voltage to display the FULL 
    indication in 0.1 V steps. 
    NEAR END 11.0 : 13.6 : 15.0
    Set the NEAR END voltage in 0.1 V steps. 
    END
    11.0 : 13.2 : 15.0
    When MANUAL is selected in the menu 
    above, set the END voltage in 0.1 V steps. 
    –CUF –
    Items/
    Data Saved Adjustable 
    Range Remarks 
    TYPE B_•Enable selection under BATTERY SELECT. 
    _:Enable selection. 
     • : Disable selection. 
    FULL 12.0 : 13.5 : 17.0
    Set the voltage to display the FULL 
    indication in 0.1 V steps. 
    NEAR END 11.0 : 11.8 : 15.0
    Set the NEAR END voltage in 0.1 V steps. 
    END
    11.0 : 11.1 : 15.0
    When MANUAL is selected in the menu 
    above, set the END voltage in 0.1 V steps. 
    –CUF – 
    						
    							109
    8
    8-6-4 MIC/AUDIO1
    8-6-5 MIC/AUDIO2
    The ____ in the Adjustable Range column indicates the preset
    mode.
    Items/
    Data Saved Adjustable 
    Range Remarks 
    FRONT VR CH1 FRONT
    W. L .
    REAR
    ALL
    OFFSelect whether or not to enable the FRONT 
    AUDIO LEVEL control for the signal selected 
    as the input signal to AUDIO CH1.
    FRONT:Only enabled when FRONT is 
    selected. 
    W. L . :Only enabled when WIRELESS is 
    selected. 
    REAR:Only enabled when REAR is 
    selected. 
    ALL:Enabled for any input selected. 
    OFF:Disabled for any input selected. 
    Recording level does not change by 
    turning the volume control.  –CUF –
    FRONT VR CH2 FRONT
    W. L .
    REAR
    ALL
    OFFSelect whether or not to enable the FRONT 
    AUDIO LEVEL control for the signal selected 
    as an input signal to AUDIO CH2. 
    FRONT:Only enabled when FRONT is 
    selected. 
    W. L . :Only enabled when WIRELESS is 
    selected. 
    REAR:Only enabled when REAR is 
    selected. 
    ALL:Enabled for any input selected. 
    OFF:Disabled for any input selected. 
    Recording level does not change by 
    turning the volume control.  –CUF –
    MIC LOWCUT 
    CH1FRONT
    REAR
    W. L .
    OFFSelect the microphone low-cut filter. 
    –CUF –
    MIC LOWCUT 
    CH2FRONT
    REAR
    W. L .
    OFFSelect the microphone low-cut filter. 
    –CUF –
    MIC LOWCUT 
    CH3FRONT
    REAR
    W. L .
    OFFSelect the microphone low-cut filter. 
    vCUF –
    MIC LOWCUT 
    CH4FRONT
    REAR
    W. L .
    OFFSelect the microphone low-cut filter. 
    –CUF –
    LIMITER CH1 ON
    OFFSelect the limiter. 
    –CUF –
    LIMITER CH2 ON
    OFFSelect the limiter. 
    –CUF –
    AU TO  L E VE L 
    CH3ONOFFSelect the level setting method. 
    –CUF –
    AU TO  L E VE L 
    CH4ONOFFSelect the level setting method. 
    –CUF –
    REC
    CH3/CH4SWCH1/2Select the signals to be recorded in CH3 
    and CH4. 
    SW:According to camera’s CH3 and CH4 
    selector switches. 
    CH1/2:Record same signals as CH1 and 
    CH2. 
    –CUF –
    25M REC CH 
    SEL2CH4CHSelect the audio channels to be recorded in 
    the DVCPRO and DV formats. 
    2CH:Only recorded in CH1 and CH2. 
    4CH:Recorded in all channels from CH1 
    to CH4. 
    –CUF –
    Items/
    Data Saved Adjustable 
    Range Remarks
    TEST TONE NORMALALWAYS
    OFF
    CHSELSelect the test signal. NORMAL:Output test tones to CH1/2 when 
    the OUTPUT/AUTO KNEE 
    selector switch is set to BARS and 
    the AUDIO IN switch CH1 is set to 
    FRONT. 
    ALWAYS:Output test tones to CH1/2 when 
    OUTPU/AUTO KNEE selector 
    switch is set to BARS. 
    OFF:Disable test tone output. 
    CHSEL:Output test tone to the channels 
    where the AUDIO IN switch CH1 
    or CH2 is set to FRONT when 
    OUTPUT/AUTO KNEE selector 
    switch is set to BARS. The test 
    tone is not output to CH3 and 
    CH4.
    –CUF –
    Items/
    Data Saved Adjustable 
    Range Remarks
    FRONT MIC 
    POWERONOFFSelect the phantom power supply for the 
    front microphone. 
    –CUF –
    REAR MIC 
    POWERONOFFSelect the phantom power supply for the 
    rear microphone. 
    –CUF –
    AUDIO OUT ONOFFSet the audio output circuit. 
    OFF:Power-down output circuit to disable 
    output. 
    ON:Enable output. 
    –CUF –
    MONITOR 
    SELECTSTEREOMIXSelect the signal format for the monitor 
    output. 
    –CUF –
    FRONT MIC 
    LEVEL–40dB–50dBSelect the front microphone input level. 
    –CUF –
    REAR MIC CH1 
    LV L–50dB
    –60dBSelect the rear microphone input level. 
    –CUF –
    REAR MIC CH2 
    LV L–50dB
    –60dBSelect the rear microphone input level. 
    –CUF –
    REAR LINE IN 
    LV L0dB
    +4dBSelect the rear line input level. 
    –CUF –
    AUDIO OUT LVL 0dB
    +4dBSelect the audio output level. 
    –CUF –
    HEADROOM 18dB
    20dBSet the headroom (standard level). 
    –CUF –
    WIRELESS 
    WARNON
    OFFSelect whether or not to enable the alarm to 
    trigger for poor wireless receiver reception. 
    –CUF – 
    						
    							110
    8-6-6 TC/UB
    8-6-7 UMID SET/INFO
    
    Please refer to [4-5-6 Setting the UMID Information] for the
    UMID information setting. 
    The ____ in the Adjustable Range column indicates the preset
    mode. 
    Items/
    Data Saved Adjustable 
    Range Remarks 
    TC MODE DFNDFSet the time code mode. 
    DF: Drop frame. 
    NDF: Non drop frame. 
    –CUF –
    UB MODE USERTIME
    DAT E
    EXT
    TCG
    FRM RATE
    REGENSelect the user bits mode. 
    USER:Select UB value set in the LCD 
    section. 
    TIME:Select local time (hours, minutes, 
    seconds). 
    DAT E:Select local date and time (2 last 
    digits of year, month, date, time). 
    EXT:Slaved to UB from TC-IN. If reading 
    fails, USER value is retained. 
    TCG:TCG value enters UB. 
    FRM RATE:
    Select same camera shoting 
    information (frame rate, etc.) with the 
    VAUX UB (VITC UB). 
    REGEN:Read out value stored in the card 
    and record value continuously. 
    –CUF –
    VITC UB MODE USER/EXT
    TIME
    DAT E
    TCG
    FRM RATE
    REGEN
    Select the user bits mode for VAUX TC 
    (VITC). 
    USER/EXT:
    If UB MODE is set to EXT, the EXT 
    value is recorded. If not, USER value 
    set by UB is recorded. 
    TIME:Select local time (hours, minutes, 
    seconds). 
    DAT E:Select local date and time (2 last 
    digits of year, month, date, time). 
    TCG:TCG value enters UB. 
    FRM RATE:
    Select same camera shoting 
    information (frame rate, etc.) with the 
    VAUX UB (VITC UB). 
    REGEN:Read out value stored in card and 
    record value continuously. 
    –CUF –
    TCG SET HOLD ON
    OFFON/OFF switching for the feature that 
    always starts recording (when the power is 
    turned ON again) the TCG value that was 
    set before the power is turned OFF. 
    –CUF –
    FIRST REC TC REGENPRESETFor the first recording after the power is 
    turned on, a P2 card is inserted and then 
    switching from this P2 card to another 
    recording-target P2 card is performed, 
    select whether or not to regenerate the time 
    code as the value on the new P2 card.
    REGEN:For clips recorded on the recording-
    target P2 card, regenerate the time 
    code as the time code of the clip that 
    has the most recent date and time. 
    PRESET:
    Use the camera-recorder’s internal 
    time code. 
    
    Set the date and time accurately. For 
    guidance on setting, see [4-5-2 Setting the 
    Internal Clock’s Date and Time].
    –CUF –
    P. O F F  L C D  
    DISPLAYONOFFSelect whether or not to display the time 
    code setting and counter indication on the 
    LCD monitor when the power is turned OFF. 
    ON:Display setting and indication while 
    the power is turned OFF. 
    OFF:Power-down LCD monitor while 
    camera power is turned OFF. Setting 
    and indication disabled. 
    –CUF –
    Items/
    Data Saved Adjustable 
    Range Remarks
    TC OUT TCGTCG/TCRSelect the time code to be output to the time 
    code output connector. 
    TCG:Always output time code generator 
    value. 
    TCG/TCR:
    Display time code generator value in 
    E-E mode, and time code reader 
    value in V-V mode. 
    –CUF –
    TC DISP SEL 30F24FSelect the display format for the time code 
    frame digits. 
    30F:Display time code frame digits in 30 
    frames. 
    24F:Convert time code frame digits into 
    24 frames for display. 
    –CUF –
    Items/
    Data Saved Adjustable 
    Range Remarks
    COUNTRY NO-INFOInput the user’s country. NO-INFO is 
    displayed until the input completes. 
    –CUF –
    ORGANIZATIONNO-INFOInput the user’s organisation or company 
    name. NO-INFO is displayed until the input 
    completes. 
    –CUF –
    USER NO-INFOInput the user name. NO-INFO is displayed 
    until the input completes. 
    –CUF –
    DEVICE NODEIndicate the product ID number. 
    ––––– 
    						