101 8 8-4-6 MODE CHECK IND 8-4-7 !LED If both GAIN (0 dB) and GAIN (–3 dB) are set to ON, the LED illuminates except when GAIN is adjusted to 0 dB and –3 dB. The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks STATUS ONOFFSelect whether or not to display the status indication during MODE CHECK. –CUFE !LED ONOFFSelect whether or not to display the cause indication screen when the ! LED turns on during MODE CHECK –CUFE FUNCTION ONOFFSelect whether or not to display the FUNCTION indication screen during MODE CHECK. –CUFE AU D I O O NOFFSelect whether or not to display the AUDIO indication screen during MODE CHECK. –CUFE P.ON IND ONOFFSelect whether or not to display the status indication screen after the power is turned ON. –CUFE Items/ Data Saved Adjustable Range Remarks GAIN(0dB) ONOFFSelect whether or not to illuminate when GAIN is set to other than 0 dB. –CUFE GAIN (-3dB) ON OFFSelect whether or not to illuminate when GAIN is set to other than -3 dB. –CUFE DS.GAIN ON OFFSelect whether or not to illuminate when DS.GAIN (storage gain) is ON. –CUFE SHUTTER ONOFFSelect whether or not to illuminate when the shutter is set to ON. –CUFE WHITE PRESETON OFFSelect whether or not to illuminate when the WHITE BAL switch is set to PRST. –CUFE EXTENDER ONOFFSelect whether or not to illuminate when the lens is in EXTENDER mode. –CUFE BLACK STR ON OFFSelect whether or not to illuminate when BLACK STRETCH is used. –CUFE MATRIX ON OFFSelect whether or not to illuminate when MATRIX is set to ON. –CUFE COLOR CORRECTIONON OFFSelect whether or not to illuminate when COLOR CORRECTION is set to ON. –CUFE FILTER ON OFFSelect whether or not to illuminate the lamp when filter1 (3200K) is not 3200K. –CUFE SUPER V ON OFFSelect whether or not to illuminate when SUPER V is set to ON. –CUFE 50M/25M/DV OFFW/O 50M W/O 25M W/O DVSelect whether or not to illuminate according to the recording mode. OFF:Does not illuminate in any recording mode. W/O 50M: Illuminate except in DVCPRO50 mode. W/O 25M: llluminate except in DVCPRO mode. W/O DV: Illuminate except in DV mode. –CUFE AT W ON OFFSelect whether or not to illuminate when auto-tracking white balance is allocated to the WHITE BAL switch B. –CUFE D.ZOOM ON OFFSelect whether or not to illuminate during digital zoom operation. –CUFE
102 8-5 CAM OPERATION 8-5-1 CAMERA ID This setting is canceled when READ FACTORY DATA is selected. 8-5-2 SHUTTER SPEED8-5-3 SHUTTER SELECT The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks ID1Setting 1 for the CAMERA ID recorded on color bars. Up to 10 characters are allowed for this setting. –CUF – ID2Setting 2 for the CAMERA ID recorded on color bars. Up to 10 characters are allowed for this setting. –CUF – ID3Setting 3 for the CAMERA ID recorded on color bars. Up to 10 characters are allowed for this setting. –CUF – Items/ Data Saved Adjustable Range Remarks SYNCHRO SCANONOFFAllocate SYNCHRO SCAN as a shutter speed selectable by the shutter switch. –CUFE SUPER V ON OFFAllocate SUPER V as a shutter speed selectable by the shutter switch. –CUFE POSITION1 ONOFFAllocate the shutter speed set by POSITION SELECT in the screen as the shutter speed selectable by the shutter switch. –CUFE POSITION2 ONOFFAllocate the shutter speed set by POSITION2 SELECT in the screen as the shutter speed selectable by the shutter switch. –CUFE POSITION3 ONOFFAllocate the shutter speed set by POSITION3 SELECT in the screen as the shutter speed selectable by the shutter switch. –CUFE POSITION4 ONOFFAllocate the shutter speed set by POSITION4 SELECT in the screen as the shutter speed selectable by the shutter switch. –CUFE POSITION5 ONOFFAllocate the shutter speed set by POSITION5 SELECT in the screen as the shutter speed selectable by the shutter switch. –CUFE POSITION6 ONOFFAllocate the shutter speed set by POSITION6 SELECT in the screen as the shutter speed selectable by the shutter switch. –CUFE Items/ Data Saved Adjustable Range Remarks SUPER V MODEFRM1FRM2Select the SUPER V switching mode. FRM1: Normal mode. FRM2: After-image reduction mode. The SUPER V mode increases vertical resolution by directly outputting the photo- diode vertical signal from the CCD. FRM1 sets the accumulation level to 1/30th second. FRM sets the level to 1/60th second, reducing sensitivity by half. –CUFE POSITION1 SEL1/1001/120 1/250 1/500 1/1000 1/2000Select the shutter speed to be allocated to POSITION1. –CUFE POSITION2 SEL1/100 1/120 1/250 1/500 1/1000 1/2000 Select the shutter speed to be allocated to POSITION2. –CUFE POSITION3 SEL1/100 1/120 1/250 1/500 1/1000 1/2000 Select the shutter speed to be allocated to POSITION3. –CUFE POSITION4 SEL1/100 1/120 1/250 1/500 1/1000 1/2000 Select the shutter speed to be allocated to POSITION4. –CUFE POSITION5 SEL1/100 1/120 1/250 1/500 1/1000 1/2000 Select the shutter speed to be allocated to POSITION5. –CUFE POSITION6 SEL1/100 1/120 1/250 1/500 1/1000 1/2000Select the shutter speed to be allocated to POSITION6. –CUFE
103 8 8-5-4 USER SW For each function of the USER switches, refer to [4-9-4 Assigning Functions to USER MAIN, USER1 and USER2 Buttons]. 8-5-5 SW MODE The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks USER MAIN SW INH S.GAIN DS.GAIN S.IRIS I.OVR S.BLK B.STR D. Z O O M AT W Y GET NEWS-G. AUD IO CH 1 AUD IO CH 2 REC SW RET SW SLOT SELAllocate the USER MAIN button. –CUFE USER1 SW INH S.GAIN DS.GAIN S.IRIS I.OVR S.BLK B.STR D. Z O O M AT W Y GET NEWS-G. AUD IO CH 1 AUD IO CH 2 REC SW RET SW SLOT SEL Allocate the USER1 button. –CUFE USER2 SW INH S.GAIN DS.GAIN S.IRIS I.OVR S.BLK B.STR D. Z O O M AT W Y GET NEWS-G. AUD IO CH 1 AUD IO CH 2 REC SW RET SW SLOT SEL Allocate the USER2 button. –CUFE Items/ Data Saved Adjustable Range Remarks RET SW RECCHECKCAM RET Select the RET switch function. REC CHECK: Perform REC REVIEW. CAM RET: Perform return signal output. –CUFE S.BLK LVL OFF –10 –20 –30 Set the super black level. –CUFE AUTO KNEE SWONOFFSelect whether or not to use the AUTO KNEE switch. SCUF E SHD,ABB SW CTLONOFFSelect whether or not to enable the automatic black shading adjustment if the ABB switch has been pressed for 5 seconds or more. –CUFE COLOR BARS SMPTEFULL BARS SPLIT ARIBSelect the color bars to use. SMPTE:Use the SMPTE color bars. FULL BARS:Use full color bars. SPLIT:Use SPLIT color bars. ARIB:Use ARIB multi-format color bars. –CUFE S.GAIN OFF L/M/HS.GAINSelect when the SUPER GAIN mode is disabled. L/M/H:Disabled when the gain selector switch is operated. S.GAIN:Disabled only with the S.GAIN switch (USER button). –CUFE DS.GAIN OFF L/M/H DS.GAINSelect when the DIGITAL SUPER GAIN mode (stored gain) is disabled. L/M/H:Disabled when the gain selector switch is operated. S.GAIN:Disabled only with the S.GAIN switch (USER button). –CUFE ECU DATA SAVEON OFFON:Store the values set and adjusted with the ECU when the ECU is disconnected from the camera- recorder. OFF:Does not store camera-related set values. –CUF – ECU REC CHK SWR.REVIEWPLAYSelect the camera-recorder operation to be performed when the ECU REC CHECK button is pressed. R.REVIEW:Perform REC REVIEW. PLAY:Play back the most-recently recorded clip from the beginning. –CUFE
104 8-5-6 WHITE BALANCE MODE 8-5-7 USER SW GAIN The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks FILTER INH ONOFFSelect whether or not to retain white balance memory (A/B) data for individual filters. ON:Retain data in the A/B memory (2 memory areas) regardless of the filters. OFF:Retain data for individual filters. –CUFE SHOCKLESS AW BOFF FA S T NORMAL SLOW1 SLOW2 SLOW3 Set SHOCKLESS AWB to ON (FAST/ NORMAL/SLOW1-3) or OFF. SHOCKLESS AWB eliminates the shock caused by switching the WHITE BAL switch’s PRST/A/B setting. The switching time can also be selected. –CUFE AWB AREA 25%50% 90%Switch the AWB detection area. 25%:Detect 25% of area around the screen center. 50%:Detect 50% of area around the screen center. 90%:Detect 90% of area in the full screen. –CUFE AWB & ABB OFFSETON OFFSelect whether or not to reset the GAIN and PED values in the ROP menu when AWB and ABB are executed. ON:Do not reset. OFF:Reset values. –CUFE COLOR TEMP PRE3200K : 5600K Set the AWB PRE color temperature. –CUFE AW B A ME MVA RSelect the function to be allocated to WHITE BAL switch A. MEM:Function to store values set by executing the auto white balance. VAR:Function to apply color temperature set by COLOR TEMP A. –CUFE COLOR TEMP A3200K : 5600K Set the color temperature when VAR is selected under AWB A. –CUFE AW B B ME MAT W VA RSelect the function to be allocated to WHITE BAL switch B. MEM:Function to store values set by executing auto white balance. AT W :Function to execute auto-tracking white balance. VAR:Function to apply color temperature set by COLOR TEMP B. –CUFE COLOR TEMP B3200K : 5600K Set the color temperature when VAR is selected under AWB B. –CUFE ATW SPEED NORMALSLOW FA S TSelect the control speed for the auto- tracking white balance. –CUFE Items/ Data Saved Adjustable Range Remarks S.GAIN 30 dB_•Select whether or not to enable 30dB for SUPER GAIN. _: Enable. • : Disable. –CUFE 36 dB_•Select whether or not to enable 36dB for SUPER GAIN. _: Enable. • : Disable. –CUFE 42 dB_•Select whether or not to enable 42dB for SUPER GAIN. _: Enable. • : Disable. –CUFE 48 dB_•Select whether or not to enable 48dB for SUPER GAIN. _: Enable. • : Disable. –CUFE DS.GAIN 6 dB(1/30) _•Select whether or not to enable 6 dB (1/30) for DS.GAIN. _: Enable. • : Disable. –CUFE 12 dB(1/15)_•Select whether or not to enable 12 dB (1/15) for DS.GAIN. _: Enable. • : Disable. –CUFE 20 dB(1/6)_•Select whether or not to enable 20 dB (1/6) for DS.GAIN. _: Enable. • : Disable. –CUFE
105 8 8-5-8 IRIS 8-6 MAIN OPERATION 8-6-1 BATTERY/P2CARD The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks A.IRIS LEVEL 000 : 050 : 100 Set the target value for auto iris. –CUFE A.IRIS PEAK/ AV E000 : 040 : 100 Determine the peak-to-standard ratio for the auto iris. A larger value sets the auto iris to respond to the peak in the IRIS detection window, while a smaller value sets it to respond to the average value in the window. –CUFE A.IRIS MODE NORM1 NORM2 CENTR Select the auto iris detection window. NORM1:The window closer to the center of the screen. NORM2:The window closer to bottom of the screen. CENTR:The spot window in the center of the screen. –CUFE S.IRIS LEVEL 000 : 080 : 100 Set the target value for the super iris. –CUFE IRIS GAIN CAM LENSSelect which unit controls IRIS GAIN. Lenses with an extender, such asC2, C0.8 sold before FUJINON DIGI POWER, perform IRIS compensation while enabling the extender. Therefore, if this setting is switched to CAM, the camera’s iris control will not operate properly. –CUFE IRIS GAIN VA L U E01 : 08 : 20 Set the adjustable value for IRIS GAIN. This setting is effective when CAM is selected for IRIS GAIN. –CUFE Items/ Data Saved Adjustable Range Remarks BATTERY SELECTPRO14TRIM14 HYTRN50 HYTRN100 HYTRN120 DIONIC90 DIONIC160 HP-90L BP-H120 NP-L50 ENDURA50 ENDURA80 BP-L60/90 NiCd14 NiCd13 NiCd12 TYPE A TYPE BSelect the battery to use. Remaining capacity detection is also performed according to the selected battery. The selectable battery types change depending on the settings under [8-6-2 BATTERY SETTING1] and [8-6-3 BATTERY SETTING2]. –CUF – EXT DC IN SELECTAC _ AD PTPRO14 TRIM14 HYTRN50 HYTRN100 HYTRN120 DIONIC90 DIONIC160 HP-90L BP-H120 NP-L50 ENDURA50 ENDURA80 BP-L60/90 NiCd14 NiCd13 NiCd12 TYPE A TYPE BSet the remaining capacity detection type when a battery is connected to the DC IN connector. Remaining capacity detection is also performed according to the selected battery type. The selectable battery types change depending on the settings under [8-6-2 BATTERY SETTING1] and [8-6-3 BATTERY SETTING2]. The % display is disabled even when a digital battery is connected to the DC IN connector. –CUF – BATT NEAR END ALARMON OFFSelect whether or not to set the alarm to beep for BATT NEAR END ALARM. –CUF – BATT NEAR END CANCELONOFFIf set to ON, the warning tone and indication can be canceled by pressing the MODE CHECK button when BATT NEAR END ALARM is triggered. –CUF – BATT END ALARMONOFFSelect whether or not to set the alarm to beep for BATT END ALARM. –CUF – BATT REMAIN FULL100% 70%Set the display content of the remaining battery capacity indicator bars in the display window when using a digital battery. 100%: Indicate FULL at 100% capacity. 70%: Indicate FULL at 70% capacity. –CUF –
106 8-6-2 BATTERY SETTING1 The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks CARD NEAR END ALARMON OFFSelect whether or not to set the alarm to beep for P2 CARD NEAR END ALARM. –CUF – CARD NEAR END TIME 3min 2minSet the remaining time to indicate the P2 CARD NEAR END TIME alarm. –CUF – CARD END ALARMONOFFSelect whether or not to set the alarm to beep for P2 CARD END ALARM. –CUF – CARD REMAIN/„5min/„3min/„Set the length of time for one segment („) of the P2 card’s remaining capacity indicator bars. 5min:One segment represents 5 minutes. 3min:One segment represents 3 minutes. –CUF – Items/ Data Saved Adjustable Range Remarks PRO14_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AU TOMANUALSelect auto or manual to set the NEAR END voltage. AU TO :Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 13.7 : 15.0 When MANUAL is selected in the above menu, set the NEAR END voltage in 0.1 V steps. –CUF – TRIM14_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AU TOMANUALSelect auto or manual to set the NEAR END voltage. AU TO :Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 13.6 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – HYTRON50_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AU TOMANUALSelect auto or manual to set the NEAR END voltage. AU TO :Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 13.1 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – HYTRON100_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AU TOMANUALSelect auto or manual to set the NEAR END voltage. AU TO :Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 13.2 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – HYTRON120_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AU TOMANUALSelect auto or manual to set the NEAR END voltage. AU TO :Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 13.1 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF –
107 8 The remaining battery capacity for digital batteries is displayed as % inside the viewfinder (PRO14/TRIM14/HYTRON50/ HYTRON100/HYTRON120/DIONIC90/DIONIC160/NP-L50). The BATT NEAR END alarm, however, is triggered according to the setting on the screen, regardless of the % indication. The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks DIONIC90_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AUTOMANUALSelect auto or manual to set the NEAR END voltage. AU TO:Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 13.6 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – DIONIC160_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AUTOMANUALSelect auto or manual to set the NEAR END voltage. AU TO:Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 13.3 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – HP-90L_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AUTOMANUALSelect auto or manual to set the NEAR END voltage. AU TO:Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 12.4 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – BP-H120_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AUTOMANUALSelect auto or manual to set the NEAR END voltage. AU TO:Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 11.5 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – NP-L50_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AUTOMANUALSelect auto or manual to set the NEAR END voltage. AU TO:Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 13.0 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – Items/ Data Saved Adjustable Range Remarks ENDURA50_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AU TOMANUALSelect auto or manual to set the NEAR END voltage. AU TO :Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 13.1 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – ENDURA80_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AU TOMANUALSelect auto or manual to set the NEAR END voltage. AU TO :Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 13.1 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – BP-L60/90_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. AU TOMANUALSelect auto or manual to set the NEAR END voltage. AU TO :Set voltage automatically. MANUAL:Set voltage manually. 11.0 : 11.2 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF –
108 8-6-3 BATTERY SETTING2 The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks NiCd14_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. NEAR END 11.0 : 13.6 : 15.0 Set the NEAR END voltage in 0.1 V steps. END 11.0 : 13.2 : 15.0 When MANUAL is selected in the menu above, set the END voltage in 0.1 V steps. –CUF – NiCd13_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. NEAR END 11.0 : 12.7 : 15.0 Set the NEAR END voltage in 0.1 V steps. END 11.0 : 12.2 : 15.0 When MANUAL is selected in the menu above, set the END voltage in 0.1 V steps. –CUF – NiCd12_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. NEAR END 11.0 : 11.5 : 15.0 Set the NEAR END voltage in 0.1 V steps. END 11.0 : 11.2 : 15.0 When MANUAL is selected in the menu above, set the END voltage in 0.1 V steps. –CUF – TYPE A_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. FULL 12.0 : 15.0 : 17.0 Set the voltage to display the FULL indication in 0.1 V steps. NEAR END 11.0 : 13.6 : 15.0 Set the NEAR END voltage in 0.1 V steps. END 11.0 : 13.2 : 15.0 When MANUAL is selected in the menu above, set the END voltage in 0.1 V steps. –CUF – Items/ Data Saved Adjustable Range Remarks TYPE B_•Enable selection under BATTERY SELECT. _:Enable selection. • : Disable selection. FULL 12.0 : 13.5 : 17.0 Set the voltage to display the FULL indication in 0.1 V steps. NEAR END 11.0 : 11.8 : 15.0 Set the NEAR END voltage in 0.1 V steps. END 11.0 : 11.1 : 15.0 When MANUAL is selected in the menu above, set the END voltage in 0.1 V steps. –CUF –
109 8 8-6-4 MIC/AUDIO1 8-6-5 MIC/AUDIO2 The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks FRONT VR CH1 FRONT W. L . REAR ALL OFFSelect whether or not to enable the FRONT AUDIO LEVEL control for the signal selected as the input signal to AUDIO CH1. FRONT:Only enabled when FRONT is selected. W. L . :Only enabled when WIRELESS is selected. REAR:Only enabled when REAR is selected. ALL:Enabled for any input selected. OFF:Disabled for any input selected. Recording level does not change by turning the volume control. –CUF – FRONT VR CH2 FRONT W. L . REAR ALL OFFSelect whether or not to enable the FRONT AUDIO LEVEL control for the signal selected as an input signal to AUDIO CH2. FRONT:Only enabled when FRONT is selected. W. L . :Only enabled when WIRELESS is selected. REAR:Only enabled when REAR is selected. ALL:Enabled for any input selected. OFF:Disabled for any input selected. Recording level does not change by turning the volume control. –CUF – MIC LOWCUT CH1FRONT REAR W. L . OFFSelect the microphone low-cut filter. –CUF – MIC LOWCUT CH2FRONT REAR W. L . OFFSelect the microphone low-cut filter. –CUF – MIC LOWCUT CH3FRONT REAR W. L . OFFSelect the microphone low-cut filter. vCUF – MIC LOWCUT CH4FRONT REAR W. L . OFFSelect the microphone low-cut filter. –CUF – LIMITER CH1 ON OFFSelect the limiter. –CUF – LIMITER CH2 ON OFFSelect the limiter. –CUF – AU TO L E VE L CH3ONOFFSelect the level setting method. –CUF – AU TO L E VE L CH4ONOFFSelect the level setting method. –CUF – REC CH3/CH4SWCH1/2Select the signals to be recorded in CH3 and CH4. SW:According to camera’s CH3 and CH4 selector switches. CH1/2:Record same signals as CH1 and CH2. –CUF – 25M REC CH SEL2CH4CHSelect the audio channels to be recorded in the DVCPRO and DV formats. 2CH:Only recorded in CH1 and CH2. 4CH:Recorded in all channels from CH1 to CH4. –CUF – Items/ Data Saved Adjustable Range Remarks TEST TONE NORMALALWAYS OFF CHSELSelect the test signal. NORMAL:Output test tones to CH1/2 when the OUTPUT/AUTO KNEE selector switch is set to BARS and the AUDIO IN switch CH1 is set to FRONT. ALWAYS:Output test tones to CH1/2 when OUTPU/AUTO KNEE selector switch is set to BARS. OFF:Disable test tone output. CHSEL:Output test tone to the channels where the AUDIO IN switch CH1 or CH2 is set to FRONT when OUTPUT/AUTO KNEE selector switch is set to BARS. The test tone is not output to CH3 and CH4. –CUF – Items/ Data Saved Adjustable Range Remarks FRONT MIC POWERONOFFSelect the phantom power supply for the front microphone. –CUF – REAR MIC POWERONOFFSelect the phantom power supply for the rear microphone. –CUF – AUDIO OUT ONOFFSet the audio output circuit. OFF:Power-down output circuit to disable output. ON:Enable output. –CUF – MONITOR SELECTSTEREOMIXSelect the signal format for the monitor output. –CUF – FRONT MIC LEVEL–40dB–50dBSelect the front microphone input level. –CUF – REAR MIC CH1 LV L–50dB –60dBSelect the rear microphone input level. –CUF – REAR MIC CH2 LV L–50dB –60dBSelect the rear microphone input level. –CUF – REAR LINE IN LV L0dB +4dBSelect the rear line input level. –CUF – AUDIO OUT LVL 0dB +4dBSelect the audio output level. –CUF – HEADROOM 18dB 20dBSet the headroom (standard level). –CUF – WIRELESS WARNON OFFSelect whether or not to enable the alarm to trigger for poor wireless receiver reception. –CUF –
110 8-6-6 TC/UB 8-6-7 UMID SET/INFO Please refer to [4-5-6 Setting the UMID Information] for the UMID information setting. The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks TC MODE DFNDFSet the time code mode. DF: Drop frame. NDF: Non drop frame. –CUF – UB MODE USERTIME DAT E EXT TCG FRM RATE REGENSelect the user bits mode. USER:Select UB value set in the LCD section. TIME:Select local time (hours, minutes, seconds). DAT E:Select local date and time (2 last digits of year, month, date, time). EXT:Slaved to UB from TC-IN. If reading fails, USER value is retained. TCG:TCG value enters UB. FRM RATE: Select same camera shoting information (frame rate, etc.) with the VAUX UB (VITC UB). REGEN:Read out value stored in the card and record value continuously. –CUF – VITC UB MODE USER/EXT TIME DAT E TCG FRM RATE REGEN Select the user bits mode for VAUX TC (VITC). USER/EXT: If UB MODE is set to EXT, the EXT value is recorded. If not, USER value set by UB is recorded. TIME:Select local time (hours, minutes, seconds). DAT E:Select local date and time (2 last digits of year, month, date, time). TCG:TCG value enters UB. FRM RATE: Select same camera shoting information (frame rate, etc.) with the VAUX UB (VITC UB). REGEN:Read out value stored in card and record value continuously. –CUF – TCG SET HOLD ON OFFON/OFF switching for the feature that always starts recording (when the power is turned ON again) the TCG value that was set before the power is turned OFF. –CUF – FIRST REC TC REGENPRESETFor the first recording after the power is turned on, a P2 card is inserted and then switching from this P2 card to another recording-target P2 card is performed, select whether or not to regenerate the time code as the value on the new P2 card. REGEN:For clips recorded on the recording- target P2 card, regenerate the time code as the time code of the clip that has the most recent date and time. PRESET: Use the camera-recorder’s internal time code. Set the date and time accurately. For guidance on setting, see [4-5-2 Setting the Internal Clock’s Date and Time]. –CUF – P. O F F L C D DISPLAYONOFFSelect whether or not to display the time code setting and counter indication on the LCD monitor when the power is turned OFF. ON:Display setting and indication while the power is turned OFF. OFF:Power-down LCD monitor while camera power is turned OFF. Setting and indication disabled. –CUF – Items/ Data Saved Adjustable Range Remarks TC OUT TCGTCG/TCRSelect the time code to be output to the time code output connector. TCG:Always output time code generator value. TCG/TCR: Display time code generator value in E-E mode, and time code reader value in V-V mode. –CUF – TC DISP SEL 30F24FSelect the display format for the time code frame digits. 30F:Display time code frame digits in 30 frames. 24F:Convert time code frame digits into 24 frames for display. –CUF – Items/ Data Saved Adjustable Range Remarks COUNTRY NO-INFOInput the user’s country. NO-INFO is displayed until the input completes. –CUF – ORGANIZATIONNO-INFOInput the user’s organisation or company name. NO-INFO is displayed until the input completes. –CUF – USER NO-INFOInput the user name. NO-INFO is displayed until the input completes. –CUF – DEVICE NODEIndicate the product ID number. –––––