Page 101

101
8
8-4-6 MODE CHECK IND 8-4-7  !LED

If both GAIN (0 dB) and GAIN (–3 dB) are set to ON, the LED
illuminates except when GAIN is adjusted to 0 dB and –3 dB. 
The ____ in the Adjustable Range column indicates the preset
mode. 
Items/
Data Saved Adjustable 
Range Remarks 
STATUS ONOFFSelect whether or not to display the status 
indication during MODE CHECK. 
–CUFE
!LED ONOFFSelect whether or not to display the cause 
indication screen when the ! LED turns on 
during MODE CHECK 
–CUFE
FUNCTION...

Page 102

102
8-5 CAM OPERATION
8-5-1 CAMERA ID

This setting is canceled when READ FACTORY DATA is
selected. 
8-5-2 SHUTTER SPEED8-5-3 SHUTTER SELECT
The ____ in the Adjustable Range column indicates the preset
mode. 
Items/
Data Saved Adjustable 
Range Remarks 
ID1Setting 1 for the CAMERA ID recorded on 
color bars. Up to 10 characters are allowed 
for this setting.
–CUF –
ID2Setting 2 for the CAMERA ID recorded on 
color bars. Up to 10 characters are allowed 
for this setting.
–CUF –
ID3Setting 3 for the CAMERA...

Page 103

103
8
8-5-4 USER SW

For each function of the USER switches, refer to [4-9-4
Assigning Functions to USER MAIN, USER1 and USER2
Buttons].
8-5-5 SW MODE
The ____ in the Adjustable Range column indicates the preset
mode. 
Items/
Data Saved Adjustable 
Range Remarks 
USER MAIN SW INH
S.GAIN
DS.GAIN
S.IRIS
I.OVR
S.BLK
B.STR
D. Z O O M
AT W
Y GET
NEWS-G.
AUD IO  CH 1
AUD IO  CH 2
REC SW
RET SW
SLOT SELAllocate the USER MAIN button. 
–CUFE
USER1 SW INH
S.GAIN
DS.GAIN
S.IRIS
I.OVR
S.BLK
B.STR
D. Z O O M
AT W
Y...

Page 104

104
8-5-6 WHITE BALANCE MODE 8-5-7 USER SW GAIN
The ____ in the Adjustable Range column indicates the preset
mode. 
Items/
Data Saved Adjustable 
Range Remarks 
FILTER INH ONOFFSelect whether or not to retain white balance 
memory (A/B) data for individual filters. 
ON:Retain data in the A/B memory (2 
memory areas) regardless of the 
filters. 
OFF:Retain data for individual filters. 
–CUFE
SHOCKLESS 
AW BOFF
FA S T
NORMAL
SLOW1
SLOW2
SLOW3
Set SHOCKLESS AWB to ON (FAST/
NORMAL/SLOW1-3) or OFF....

Page 105

105
8
8-5-8 IRIS
8-6 MAIN OPERATION
8-6-1 BATTERY/P2CARD
The ____ in the Adjustable Range column indicates the preset
mode. 
Items/
Data Saved Adjustable 
Range Remarks 
A.IRIS LEVEL 000 : 050 : 100
Set the target value for auto iris. 
–CUFE
A.IRIS PEAK/
AV E000 : 040 : 100
Determine the peak-to-standard ratio for the 
auto iris. 
A larger value sets the auto iris to respond to 
the peak in the IRIS detection window, while 
a smaller value sets it to respond to the 
average value in the window. 
–CUFE...

Page 106

106
8-6-2 BATTERY SETTING1
The ____ in the Adjustable Range column indicates the preset
mode. 
Items/
Data Saved Adjustable 
Range Remarks 
CARD NEAR 
END ALARMON
OFFSelect whether or not to set the alarm to 
beep for P2 CARD NEAR END ALARM. 
–CUF –
CARD NEAR 
END TIME 3min
2minSet the remaining time to indicate the P2 
CARD NEAR END TIME alarm. 
–CUF –
CARD END 
ALARMONOFFSelect whether or not to set the alarm to 
beep for P2 CARD END ALARM. 
–CUF –
CARD REMAIN/„5min/„3min/„Set the length of time for...

Page 107

107
8

The remaining battery capacity for digital batteries is displayed
as % inside the viewfinder (PRO14/TRIM14/HYTRON50/
HYTRON100/HYTRON120/DIONIC90/DIONIC160/NP-L50). 
The BATT NEAR END alarm, however, is triggered according to
the setting on the  screen, regardless of
the % indication. 
The ____ in the Adjustable Range column indicates the preset
mode.
Items/
Data Saved Adjustable 
Range Remarks 
DIONIC90_•Enable selection under BATTERY SELECT. 
_:Enable selection. 
 • : Disable selection....

Page 108

108
8-6-3 BATTERY SETTING2
The ____ in the Adjustable Range column indicates the preset
mode.
Items/
Data Saved Adjustable 
Range Remarks 
NiCd14_•Enable selection under BATTERY SELECT. 
_:Enable selection. 
 • : Disable selection. 
NEAR END 11.0 : 13.6 : 15.0
Set the NEAR END voltage in 0.1 V steps. 
END
11.0 : 13.2 : 15.0
When MANUAL is selected in the menu 
above, set the END voltage in 0.1 V steps. 
–CUF –
NiCd13_•Enable selection under BATTERY SELECT. 
_:Enable selection. 
 • : Disable selection....

Page 109

109
8
8-6-4 MIC/AUDIO1
8-6-5 MIC/AUDIO2
The ____ in the Adjustable Range column indicates the preset
mode.
Items/
Data Saved Adjustable 
Range Remarks 
FRONT VR CH1 FRONT
W. L .
REAR
ALL
OFFSelect whether or not to enable the FRONT 
AUDIO LEVEL control for the signal selected 
as the input signal to AUDIO CH1.
FRONT:Only enabled when FRONT is 
selected. 
W. L . :Only enabled when WIRELESS is 
selected. 
REAR:Only enabled when REAR is 
selected. 
ALL:Enabled for any input selected. 
OFF:Disabled for any...

Page 110

110
8-6-6 TC/UB
8-6-7 UMID SET/INFO

Please refer to [4-5-6 Setting the UMID Information] for the
UMID information setting. 
The ____ in the Adjustable Range column indicates the preset
mode. 
Items/
Data Saved Adjustable 
Range Remarks 
TC MODE DFNDFSet the time code mode. 
DF: Drop frame. 
NDF: Non drop frame. 
–CUF –
UB MODE USERTIME
DAT E
EXT
TCG
FRM RATE
REGENSelect the user bits mode. 
USER:Select UB value set in the LCD 
section. 
TIME:Select local time (hours, minutes, 
seconds). 
DAT E:Select...