Panasonic Aj Spc700p Operating Instructions Manual
Have a look at the manual Panasonic Aj Spc700p Operating Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
111 8 Chapter 8 Menu Description Tables (continued) 8-5-3 SHUTTER SELECT 8-5-4 USER SW For each function of the USER switches, refer to [4-9-4 Assigning Functions to USER MAIN, USER1 and USER2 Buttons]. The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks SUPER V MODEFRM1FRM2Select the SUPER V switching mode. FRM1: Normal mode. FRM2: After-image reduction mode. The SUPER V mode increases vertical resolution by directly outputting the photo-diode vertical signal from the CCD. FRM1 sets the accumulation level to 1/30th second. FRM sets the level to 1/60th second, reducing sensitivity by half. –CUFE POSITION1 SEL 1/1001/120 1/250 1/500 1/1000 1/2000Select the shutter speed to be allocated to POSITION1. –CUFE POSITION2 SEL 1/100 1/120 1/250 1/500 1/1000 1/2000 Select the shutter speed to be allocated to POSITION2. –CUFE POSITION3 SEL 1/100 1/120 1/250 1/500 1/1000 1/2000 Select the shutter speed to be allocated to POSITION3. –CUFE POSITION4 SEL 1/100 1/120 1/250 1/500 1/1000 1/2000 Select the shutter speed to be allocated to POSITION4. –CUFE POSITION5 SEL 1/100 1/120 1/250 1/500 1/1000 1/2000 Select the shutter speed to be allocated to POSITION5. –CUFE POSITION6 SEL 1/100 1/120 1/250 1/500 1/1000 1/2000Select the shutter speed to be allocated to POSITION6. –CUFE Items/ Data Saved Adjustable Range Remarks USER MAIN SW INH S.GAIN S.IRIS I.OVR S.BLK B.STR AT W Y GET NEWS-G. AUDIO CH1 AUDIO CH2 REC SW RET SW SLOT SEL PRE REC USB Allocate the USER MAIN button. –CUFE USER1 SW INH S.GAIN S.IRIS I.OVR S.BLK B.STR AT W Y GET NEWS-G. AUDIO CH1 AUDIO CH2 REC SW RET SW SLOT SEL PRE REC USB Allocate the USER1 button. –CUFE USER2 SW INHS.GAIN S.IRIS I.OVR S.BLK B.STR AT W Y GET NEWS-G. AUDIO CH1 AUDIO CH2 REC SW RET SW SLOT SEL PRE REC USBAllocate the USER2 button. –CUFE #,52%2 PINKUJDQQMMo+9
112 Chapter 8 Menu Description Tables (continued) 8-5-5 SW MODE 8-5-6 WHITE BALANCE MODE The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks RET SW RECCHECKCAM RET Select the RET switch function. REC CHECK: Perform REC REVIEW. CAM RET: Perform return signal output. –CUFE S.BLK LVL OFF –10 –20 –30 Set the super black level. –CUFE AUTO KNEE SW ONOFFSelect whether or not to use the AUTO KNEE switch. SCUF E SHD,ABB SW CTL ONOFFSelect whether or not to enable the automatic black shading adjustment if the ABB switch has been pressed for 5 seconds or more. –CUFE COLOR BARS SMPTEFULL BARS SPLIT ARIBSelect the color bars to use. SMPTE: Use the SMPTE color bars. FULL BARS:Use full color bars. SPLIT: Use SPLIT color bars. ARIB: Use ARIB multi-format color bars. –CUFE S.GAIN OFF L/M/HS.GAINSelect when the SUPER GAIN mode is disabled. L/M/H: Disabled when the gain selector switch is operated. S.GAIN:Disabled only with the S.GAIN switch (USER button). –CUFE ECU DATA SAVE ON OFFON: Store the values set and adjusted with the ECU when the ECU is disconnected from the camera- recorder. OFF: Does not store camera-related set values. –CUF – ECU REC CHK SW R.REVIEWPLAYSelect the camera-recorder operation to be performed when the ECU REC CHECK button is pressed. R.REVIEW: Perform REC REVIEW. PLAY: Play back the most-recently recorded clip from the beginning. –CUFE Items/ Data Saved Adjustable Range Remarks FILTER INH ONOFFSelect whether or not to retain white balance memory (A/B) data for individual filters. ON: Retain data in the A/B memory (2 memory areas) regardless of the filters. OFF: Retain data for individual filters. –CUFE SHOCKLESS AWB OFF FA S T NORMAL SLOW1 SLOW2 SLOW3 Set SHOCKLESS AWB to ON (FAST/ NORMAL/SLOW1-3) or OFF. SHOCKLESS AWB eliminates the shock caused by switching the WHITE BAL switch’s PRST/A/B setting. The switching time can also be selected. –CUFE AWB AREA 25%50% 90%Switch the AWB detection area. 25%: Detect 25% of area around the screen center. 50%: Detect 50% of area around the screen center. 90%: Detect 90% of area in the full screen. –CUFE AWB & ABB OFFSET ON OFFSelect whether or not to reset the GAIN and PED values in the ROP menu when AWB and ABB are executed. ON: Do not reset. OFF: Reset values. –CUFE COLOR TEMP PRE 3200K : 5600K Set the AWB PRE color temperature. –CUFE AWB A MEMVA RSelect the function to be allocated to WHITE BAL switch A. MEM: Function to store values set by executing the auto white balance. VAR: Function to apply color temperature set by COLOR TEMP A. –CUFE COLOR TEMP A 3200K : 5600K Set the color temperature when VAR is selected under AWB A. –CUFE AWB B MEMVA R AT WSelect the function to be allocated to WHITE BAL switch B. MEM: Function to store values set by executing auto white balance. VAR: Function to apply color temperature set by COLOR TEMP B. AT W : Function to execute auto- tracking white balance. –CUFE COLOR TEMP B 3200K : 5600K Set the color temperature when VAR is selected under AWB B. –CUFE ATW SPEED NORMALSLOW FA S TSelect the control speed for the auto- tracking white balance. –CUFE #,52%2 PINKUJDQQMMo+9
113 8 Chapter 8 Menu Description Tables (continued) 8-5-7 USER SW GAIN 8-5-8 IRIS 8-6 MAIN OPERATION 8-6-1 BATTERY/P2CARD The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks S.GAIN 30 dB_•Select whether or not to enable 30dB for SUPER GAIN. _: Enable. • : Disable. –CUFE 36 dB_•Select whether or not to enable 36dB for SUPER GAIN. _ : Enable. • : Disable. –CUFE Items/ Data Saved Adjustable Range Remarks A.IRIS LEVEL 000 : 050 : 100 Set the target value for auto iris. –CUFE A.IRIS PEAK/ AV E 000 : 040 : 100 Determine the peak-to-standard ratio for the auto iris. A larger value sets the auto iris to respond to the peak in the IRIS detection window, while a smaller value sets it to respond to the average value in the window. –CUFE A.IRIS MODE NORM1 NORM2 CENTR Select the auto iris detection window. NORM1:The window closer to the center of the screen. NORM2: The window closer to bottom of the screen. CENTR: The spot window in the center of the screen. –CUFE S.IRIS LEVEL 000 : 080 : 100 Set the target value for the super iris. –CUFE IRIS GAIN CAM LENSSelect which unit controls IRIS GAIN. Lenses with an extender, such as C2, C 0.8 sold before FUJINON DIGI POWER, perform IRIS compensation while enabling the extender. Therefore, if this setting is switched to CAM, the camera’s iris control will not operate properly. –CUFE IRIS GAIN VA L U E 01 : 08 : 20 Set the adjustable value for IRIS GAIN. This setting is effective when CAM is selected for IRIS GAIN. –CUFE Items/ Data Saved Adjustable Range Remarks BATTERY SELECTPRO14TRIM14 HYTRON50 HYTRON100 HYTRON120 DIONIC90 DIONIC160 HP-90L BP-H120 NP-L50 ENDURA50 ENDURA80 BP-L60/90 NiCd14 NiCd13 NiCd12 TYPE A TYPE BSelect the battery to use. Remaining capacity detection is also performed according to the selected battery. The selectable battery types change depending on the settings under [8-6-2 BATTERY SETTING1] and [8-6-3 BATTERY SETTING2]. –CUF – EXT DC IN SELECT AC_ADPTPRO14 TRIM14 HYTRON50 HYTRON100 HYTRON120 DIONIC90 DIONIC160 HP-90L BP-H120 NP-L50 ENDURA50 ENDURA80 BP-L60/90 NiCd14 NiCd13 NiCd12 TYPE A TYPE BSet the remaining capacity detection type when a battery is connected to the DC IN connector. Remaining capacity detection is also performed according to the selected battery type. The selectable battery types change depending on the settings under [8-6-2 BATTERY SETTING1] and [8-6-3 BATTERY SETTING2]. The % display is disabled even when a digital battery is connected to the DC IN connector. –CUF – BATT NEAR END ALARM ON OFFSelect whether or not to set the alarm to beep for BATT NEAR END ALARM. –CUF – BATT NEAR END CANCEL ONOFFIf set to ON, the warning tone and indication can be canceled by pressing the MODE CHECK button when BATT NEAR END ALARM is triggered. –CUF – BATT END ALARM ONOFFSelect whether or not to set the alarm to beep for BATT END ALARM. –CUF – BATT REMAIN FULL 70%100%Set the display content of the remaining battery capacity indicator bars in the display window when using a digital battery. 70%: Indicate FULL at 70% capacity. 100%: Indicate FULL at 100% capacity. –CUF – #,52%2 PINKUJDQQMMo+9
114 Chapter 8 Menu Description Tables (continued) 8-6-2 BATTERY SETTING1 The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks CARD NEAR END ALARMON OFFSelect whether or not to set the alarm to beep for P2 CARD NEAR END ALARM. –CUF – CARD NEAR END TIME 2min3minSet the remaining time to indicate the P2 CARD NEAR END TIME alarm. –CUF – CARD END ALARM ONOFFSelect whether or not to set the alarm to beep for P2 CARD END ALARM. –CUF – CARD REMAIN/„3min/„5min/„ Set the length of time for one segment ( „ ) of the P2 card’s remaining capacity indicator bars. 3min/ „:One segment represents 3 minutes. 5min/ „:One segment represents 5 minutes. –CUF – Items/ Data Saved Adjustable Range Remarks PRO14_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AU TOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AUTO: Set voltage automatically. 11.0 : 13.9 : 15.0 When MANUAL is selected in the above menu, set the NEAR END voltage in 0.1 V steps. –CUF – TRIM14_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AU TOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AUTO: Set voltage automatically. 11.0 : 13.6 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – HYTRON50_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AU TOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AUTO: Set voltage automatically. 11.0 : 13.1 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – HYTRON100_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AU TOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AUTO: Set voltage automatically. 11.0 : 13.2 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – HYTRON120_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AU TOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AUTO: Set voltage automatically. 11.0 : 13.1 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – #,52%2 PINKUJDQQMMo+9
115 8 Chapter 8 Menu Description Tables (continued) The remaining battery capacity for digital batteries is displayed as % inside the viewfinder (PRO14/TRIM14/ HYTRON50/HYTRON100/HYTRON120/DIONIC90/ DIONIC160/NP-L50/ENDURA50/ENDURA80). The BATT NEAR END alarm, however, is triggered according to the setting on the screen, regardless of the % indication. The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks DIONIC90_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AUTOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AUTO: Set voltage automatically. 11.0 : 13.6 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – DIONIC160_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AUTOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AUTO: Set voltage automatically. 11.0 : 13.3 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – HP-90L_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AUTOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AUTO: Set voltage automatically. 11.0 : 12.8 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – BP-H120_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AUTOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AUTO: Set voltage automatically. 11.0 : 11.5 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – NP-L50_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AUTOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AUTO: Set voltage automatically. 11.0 : 13.3 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – Items/ Data Saved Adjustable Range Remarks ENDURA50_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AUTOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AU TO: Set voltage automatically. 11.0 : 13.1 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – ENDURA80_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AUTOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AU TO: Set voltage automatically. 11.0 : 13.5 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – BP-L60/90_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. MANUAL AUTOSelect auto or manual to set the NEAR END voltage. MANUAL: Set voltage manually. AU TO: Set voltage automatically. 11.0 : 11.2 : 15.0 When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. –CUF – #,52%2 PINKUJDQQMMo+9
116 Chapter 8 Menu Description Tables (continued) 8-6-3 BATTERY SETTING2 8-6-4 MIC/AUDIO1 The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks NiCd14_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. NEAR END 11.0 : 13.6 : 15.0 Set the NEAR END voltage in 0.1 V steps. END 11.0 : 13.2 : 15.0 When MANUAL is selected in the menu above, set the END voltage in 0.1 V steps. –CUF – NiCd13_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. NEAR END 11.0 : 12.7 : 15.0 Set the NEAR END voltage in 0.1 V steps. END 11.0 : 12.2 : 15.0 When MANUAL is selected in the menu above, set the END voltage in 0.1 V steps. –CUF – NiCd12_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. NEAR END 11.0 : 11.5 : 15.0 Set the NEAR END voltage in 0.1 V steps. END 11.0 : 11.2 : 15.0 When MANUAL is selected in the menu above, set the END voltage in 0.1 V steps. –CUF – TYPE A_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. FULL 12.0 : 15.0 : 17.0 Set the voltage to display the FULL indication in 0.1 V steps. NEAR END 11.0 : 13.6 : 15.0 Set the NEAR END voltage in 0.1 V steps. END 11.0 : 13.2 : 15.0 When MANUAL is selected in the menu above, set the END voltage in 0.1 V steps. –CUF – TYPE B_•Enable selection under BATTERY SELECT. _ :Enable selection. • :Disable selection. FULL 12.0 : 13.5 : 17.0 Set the voltage to display the FULL indication in 0.1 V steps. NEAR END 11.0 : 11.8 : 15.0 Set the NEAR END voltage in 0.1 V steps. END 11.0 : 11.1 : 15.0 When MANUAL is selected in the menu above, set the END voltage in 0.1 V steps. –CUF – Items/ Data Saved Adjustable Range Remarks FRONT VR CH1 OFFFRONT W. L . REAR ALLSelect whether or not to enable the FRONT AUDIO LEVEL control for the signal selected as the input signal to AUDIO CH1. OFF: Disabled for any input selected. Recording level does not change by turning the volume control. FRONT:Only enabled when FRONT is selected. W. L . : Only enabled when WIRELESS is selected. REAR: Only enabled when REAR is selected. ALL: Enabled for any input selected. –CUF – FRONT VR CH2 OFFFRONT W. L . REAR ALLSelect whether or not to enable the FRONT AUDIO LEVEL control for the signal selected as an input signal to AUDIO CH2. OFF: Disabled for any input selected. Recording level does not change by turning the volume control. FRONT:Only enabled when FRONT is selected. W. L . : Only enabled when WIRELESS is selected. REAR: Only enabled when REAR is selected. ALL: Enabled for any input selected. –CUF – MIC LOWCUT CH1 OFFFRONT W. L . REARSelect the microphone low-cut filter. –CUF – MIC LOWCUT CH2 OFFFRONT W. L . REARSelect the microphone low-cut filter. –CUF – LIMITER CH1 ON OFFSelect the limiter. –CUF – LIMITER CH2 ON OFFSelect the limiter. –CUF – 25M REC CH SEL 2CH4CHSelect the audio channels to be recorded in the DVCPRO and DV for mats. 2CH: Only recorded in CH1 and CH2. 4CH: Recorded in all channels from CH1 to CH4. –CUF – TEST TONE OFF NORMAL ALWAYS CHSEL Select the test signal. OFF:Disable test tone output. NORMAL:Output test tones to CH1/2 when the OUTPUT/AUTO KNEE selector switch is set to BARS and the AUDIO IN switch CH1 is set to FRONT. ALWAYS:Output test tones to CH1/2 when OUTPUT/AUTO KNEE selector switch is set to BARS. CHSEL: Output test tone to the channels where the AUDIO IN switch CH1 or CH2 is set to FRONT when OUTPUT/ AUTO KNEE selector switch is set to BARS. The test tone is not output to CH3 and CH4. –CUF – #,52%2 PINKUJDQQMMo+9
117 8 Chapter 8 Menu Description Tables (continued) 8-6-5 MIC/AUDIO2 8-6-6 TC/UB The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks FRONT MIC POWERONOFFSelect the phantom power supply for the front microphone. –CUF – REAR MIC POWER ONOFFSelect the phantom power supply for the rear microphone. –CUF – AU DIO O UT ONOFFSet the audio output circuit. OFF: Power-down output circuit to disable output. ON: Enable output. –CUF – MONITOR SELECT STEREOMIXSelect the signal format for output to the PHONE (earphones) jack. –CUF – FRONT MIC LEVEL –40dB–50dBSelect the front microphone input level. –CUF – REAR MIC CH1 LV L –50dB –60dBSelect the rear microphone input level. –CUF – REAR MIC CH2 LV L –50dB –60dBSelect the rear microphone input level. –CUF – REAR LINE IN LV L –3dB 0dB +4dBSelect the rear line input level. –CUF – AU DIO O UT LVL – 3d B 0dB +4dBSelect the audio output level. –CUF – HEADROOM 18dB 20dBSet the headroom (standard level). –CUF – WIRELESS WARN ON OFFSelect whether or not to enable the alarm to trigger for poor wireless receiver reception. –CUF – Items/ Data Saved Adjustable Range Remarks TC MODE DFNDFSet the time code mode. DF: Drop frame. NDF: Non drop frame. –CUF – UB MODE USERTIME DAT E EXT TCG FRM RATE REGENSelect the user bits mode. USER: Select UB value set in the LCD section. TIME: Select local time (hours, minutes, seconds). DATE: Select local date and time (2 last digits of year, month, date, time). EXT: When “CAM” or “VIDEO” is selected in the menu option REC SIGNAL in the SYSTEM MODE screen, user’s bit input to the TC IN connector is the reference. When “1394” is selected, user’s bit input to the DVCPRO/DV connector is the reference. If reading fails, USER value is retained. TCG: TCG value enters UB. FRM RATE: Select same camera shoting information (frame rate, etc.) with the VAUX UB (VITC UB). REGEN:Read out value stored in the card and record value continuously. –CUF – VITC UB MODE USER/EXT TIME DAT E TCG FRM RATE REGEN Select the user bits mode for VAUX TC (VITC). USER/EXT:If UB MODE is set to EXT, the EXT value is recorded. If not, USER value set by UB is recorded. TIME: Select local time (hours, minutes, seconds). DATE: Select local date and time (2 last digits of year, month, date, time). TCG: TCG value enters UB. FRM RATE: Select same camera shoting information (frame rate, etc.) with the VAUX UB (VITC UB). REGEN:Read out value stored in card and record value continuously. –CUF – TCG SET HOLD ON OFFON/OFF switching for the feature that always starts recording (when the power is turned ON again) the TCG value that was set before the power is turned OFF. –CUF – #,52%2 PINKUJDQQMMo+9
118 Chapter 8 Menu Description Tables (continued) 8-6-7 UMID SET/INFO Please refer to [4-5-6 Setting UMID Information] for the UMID information setting. 8-7 FILE 8-7-1 SD CARD READ/WRITE The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks FIRST REC TC PRESET REGENFor the first recording after the power is turned on, a P2 card is inserted and then switching from this P2 card to another recording-target P2 card is performed, select whether or not to regenerate the time code as the value on the new P2 card. PRESET:Use the camera-recorder’s internal time code. REGEN:For clips recorded on the recording-target P2 card, regenerate the time code as the time code of the clip that has the most recent date and time. Set the date and time accurately. For guidance on setting, see [4-5-2 Setting the Internal Clock’s Date and Time]. –CUF – P.OFF LCD DISPLAY ONOFFSelect whether or not to display the time code setting and counter indication on the LCD monitor when the power is turned OFF. ON: Display setting and indication while the power is turned OFF. OFF: Power-down LCD monitor while camera power is turned OFF. Setting and indication disabled. –CUF – TC OUT TCGTCG/TCRSelect the time code to be output to the time code output connector. TCG: Always output time code generator value. TCG/TCR: Display time code generator value in E-E mode, and time code reader value in V-V mode. –CUF – Items/ Data Saved Adjustable Range Remarks COUNTRY NO-INFOInput the user’s country. NO-INFO is displayed until the input completes. –CUF – ORGANIZATIONNO-INFOInput the user’s organisation or company name. NO-INFO is displayed until the input completes. –CUF – USER NO-INFOInput the user name. NO-INFO is displayed until the input completes. –CUF – DEVICE NODEIndicate the product ID number. ––––– Items/ Data Saved Adjustable Range Remarks R.SELECT 1 : 8Select the file number to read out. –––F– READRead out the data from the SD memory card. ––––– W. S E L E C T 1 : 8Select the file number to write in. –––F– WRITEWrite the camera-recorder’s menu data to the SD memory card. ––––– CARD CONFIGFormat the SD memory card. ––––– TITLE READRead out the title of the data recorded on the SD memory card. ––––– TITLE1-8:Up to 8 letters can be set for the title name. ––––– #,52%2 PINKUJDQQMMo+9
119 8 Chapter 8 Menu Description Tables (continued) 8-7-2 SD CARD R/W SELECT 8-7-3 LENS FILE 8-7-4 SCENE 8-7-5 INITIALIZE The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks ID READ/ WRITEON OFFSelect whether or not to include the CAMERA ID when reading out or writing to the SD memory card. –––F– USER MENU SELECT R/W ONOFFSelect whether or not to include the FILE MENU settings when reading out or writing to the SD memory card. –––F– SYSTEM MENU R/W ONOFFSelect whether or not to include the set values on the SYSTEM SETTING page when reading out or writing to the SD memory card. –––F– PA I N T M E N U LEVEL R/W ONOFFSelect whether or not to include the adjusted values on the PAINT page when reading out or writing to the SD memory card. –––F– PA I N T M E N U SW(„) R/W ONOFFSelect whether or not to include the set values on the PAINT MENU page when reading out or writing to the SD memory card. –––F– PA I N T ( F L A R E ) R/W ON OFFSelect whether or not to include the set values on the FLARE page when reading out or writing to the SD memory card. –––F– VF MENU R/W ONOFFSelect whether or not to include the set values on the VF page when reading out or writing to the SD memory card. –––F– CAM OPE MENU R/W ONOFFSelect whether or not to include the set values on the CAM OPERATION page when reading out or writing to the SD memory card. –––F– MAIN OPE MENU R/W ONOFFSelect whether or not to include the set values on the MAIN OPERATION page when reading out or writing to the SD memory card. –––F– MAINTE MENU R/W ONOFFSelect whether or not to include the set values on the MAINTENANCE page when reading out or writing to the SD memory card. –––F– Items/ Data Saved Adjustable Range Remarks FILE NO. 1 : 8Select the lens file number. ––––– READRead the lens file data. ––––– WRITEWrite the lens file data. ––––– TITLE1-8Up to 12 letters can be set for the title name. ––––– Items/ Data Saved Adjustable Range Remarks READ USER DATARead out the data from the user area in the memory. ––––– SCENE SEL 1 : 4Select the scene file. ––––– READRead the scene file. ––––– WRITEWrite the scene file. ––––– RESETReset the scene file values to the initial values. ––––– TITLE 1-4Create the scene file title. ––––– Items/ Data Saved Adjustable Range Remarks READ FAC TO RY DATAThe menu (USER MENU, MAIN MENU, OPTION MENU) values are all reset to factory settings. ––––– WRITE USER DATASave the user preference menu data in the camera’s internal memory. ––––– RESET LENS FILESReset the lens file data to the factory settings. ––––– #,52%2 PINKUJDQQMMo+9
120 Chapter 8 Menu Description Tables (continued) 8-8 MAINTENANCE 8-8-1 SYSTEM CHECK 8-8-2 LENS ADJ 8-8-3 BLACK SHADING 8-8-4 WHITE SHADING8-8-5 DIAGNOSTIC1 The ____ in the Adjustable Range column indicates the preset mode. Items/ Data Saved Adjustable Range Remarks COLOR CHECK ON OFFON/OFF switching for checking proper operation of the camera-recorder. Displays the center Y and RGB levels on the viewfinder to indicate whether the signals have been properly processed and transmitted from the optical system to the digital system. ––––– Items/ Data Saved Adjustable Range Remarks F2.8 ADJ ON OFFThe iris is only set to F2.8 when this item set to ON. ––––– F16 ADJ ON OFFThe iris is only set to F16 when this item set to ON. ––––– Items/ Data Saved Adjustable Range Remarks CORRECT ONOFFON/OFF switching for digital black shading compensation. –CUFE DETECTION (DIG) –Execute digital black shading compensation. ––––– Items/ Data Saved Adjustable Range Remarks CORRECT ONOFFON/OFF switching for white shading compensation. –CUFE DETECTION (V SAW) –Execute white shading compensation. ––––– Items/ Data Saved Adjustable Range Remarks CAMSOFT(IN)Display the software version for the microprocessor-controlled flash. ––––– CAMSOFT (OUT)Display the software version for the external flash. ––––– CAM TABLEDisplay the table version. ––––– FONT ROMDisplay the character font version. ––––– CAM DSP CPLDDisplay the program version for the CPLD (Complex Programmable Logic Device) that processes camera block signals. ––––– CAM SYS FPGADisplay the program version for the FPGA (Field Programmable Gate Array) that processes camera block signals. ––––– PULSE FPGADisplay the program version for the FPGA that processes the CCD scanning. ––––– #,52%2 PINKUJDQQMMo+9