Page 81

7
Chapter 7  Menu description tables
81
Item/
Data storageVariable
rangeRemarks
P.OFF GPS DATA HOLDCLEARFor selecting whether or not to hold the UMID
GPS position information while the power is
off and record the information as the data still
held as the previous value until another
measurement can be taken after the power is
next turned on.
HOLD:The data is held and recorded.
CLEAR:The data is cleared at the same time
as the power is turned off, and all
zeros (no information) are recorded
from the time...

Page 82

Chapter 7  Menu description tables
82
SDC61500h00m02s00f
: 
00h04m59s29f
: 
23h59m59s29f
The shortest time is two seconds.
CU F
INTERVAL REC
MODEON
ONE SHOT
OFF
For setting the INTERVAL REC function.
ON (MEMORY):
Interval recording is possible in single-
frame units using memory.
ONE SHOT:
Recording is performed only once for the
time set in the REC TIME item, after which
it stops.
OFF:Interval recording is not performed.
F
REC TIME
SDC905
00s01f
: 
59s29fFor setting the recording time (one cut).
The...

Page 83

7
Chapter 7  Menu description tables
83
Item/
Data storageVariable
rangeRemarks
7-2-4 OUTPUT SEL
SC PHASE FINE–75: +00: +75
For finely adjusting the SD phase during genlock.When making GENLOCK adjustments to the unit,
adjust H PHASE first, followed by SC PHASE.
Item/
Data storageVariable
rangeRemarks
GENLOCKINT
EXT
26P EXTFor selecting the sync signal among the
camera signals.
INT:
For synchronizing with the internal
reference signal regardless of the
reference signal which has been
supplied to the...

Page 84

Chapter 7  Menu description tables
84
7-3-2 MATRIX
R GAIN–200: +000: +200
For setting the R channel gain. Item/
Data storageVariable
rangeRemarks
MASTER PED–200: +000: +200
For setting the master pedestal level.
MASTER DTL–31: +00: +31
For setting the H detail/V detail level.
MASTER GAMMA 0.35: 0.45: 0.75
For setting the master gamma in 0.01 steps.
KNEE POINT 70.0%: 85.0%: 107.0%
For setting the master knee position in 0.5%
steps.
KNEE SLOPE 0: 50: 99
For setting the knee slope.
G GAIN–200: +000: +200...

Page 85

7
Chapter 7  Menu description tables
85
Mg (SAT/PHASE)–63: +00: +63
For performing the magenta color correction
(saturation and hue).
R (SAT/PHASE)–63: +00: +63
For performing the red color correction
(saturation and hue).
R-Mg (SAT/PHASE)–63: +00: +63
For performing the color correction (saturation
and hue) between red and magenta.
Mg-B (SAT/PHASE)–63: +00: +63
For performing the color correction (saturation
and hue) between magenta and blue.
7-3-3 COLOR CORRECTION
Item/
Data storageVariable...

Page 86

Chapter 7  Menu description tables
86
7-3-5 MID SETTING
$MATRIX TABLEOFFA
BFor selecting the color correction table.
$COLOR
CORRECTONOFFFor selecting ON or OFF for the color
correction. Item/
Data storageVariable
rangeRemarks
$MASTER GAIN–3dB: 9dB: 30dB
For setting the master gain to –3, 0, 3, 6, 9,
12, 15, 18, 21, 24, 27 or 30 dB.
H.DTL LEVEL 00: 14: 63
For performing the H.DTL LEVEL setting.
V.DTL LEVEL 00: 20: 31
For performing the V.DTL LEVEL setting.
DTL CORING 00: 03: 15
For performing the DTL...

Page 87

7
Chapter 7  Menu description tables
87
7-3-7 ADDITIONAL DTL
Item/
Data storageVariable
rangeRemarks
KNEE APE LVL OFF
1
2: 5
For performing the KNEE APE LEVEL setting.
CHROMA DTL OFF1: 5
For performing the CHROMA DTL setting.
The chroma edge is detected and placed on
the Y signal to bolster H.DTL.  The higher the
number, the greater the correction.
DTL GAIN(+)–31: +00: +31
For changing the DTL “+” direction level.
DTL GAIN(–)–31: +00: +31
For changing the DTL “–” (down) direction
level.
DTL CLIP00: 63...

Page 88

Chapter 7  Menu description tables
88
7-3-9 KNEE/LEVEL
Item/
Data storageVariable
rangeRemarks
MASTER PED–200: +000: +200
For performing the MASTER PEDESTAL
setting.
$MANUAL KNEEON
OFFFor setting the mode which is to be established
when the AUTO KNEE switch is at OFF.  The
KNEE POINT/SLOPE setting value is active
when ON is selected.
KNEE POINT 70.0%: 85.0%: 107.0%
For setting the KNEE POINT position in 0.5%
steps.
KNEE SLOPE 00: 50: 99 (98)
For performing the KNEE width setting.
Same as KNEE OFF when...

Page 89

7
Chapter 7  Menu description tables
89
Item/
Data storageVariable
rangeRemarks
DETAILON
OFFFor selecting ON or OFF for DTL (H, V).
2D LPF ONOFFFor selecting ON or OFF for the 2-
dimensional LPF that reduces cross color.
HIGH COLOR ONOFFFor selecting ON or OFF for the mode in
which the dynamic range of the colors is
expanded.
TEST SAW ONOFFFor selecting ON or OFF for the test signals.
FLAREON
OFFFor selecting ON or OFF for the flare
compensation.
H-F COMPE.ON
OFFFor selecting ON or OFF for the mode in...

Page 90

Chapter 7  Menu description tables
90
7-4-2 VF MARKER
Item/
Data storageVariable
rangeRemarks
TABLEA
BFor selecting the VF MARKER setting table.
This item is used to set the current values of
table A or B which have been selected using
the menu items listed below.
CENTER MARK OFF1
2
3
4For selecting the center marker.
OFF:The center marker is not displayed.
1:+ (large)
2:Center blank (large)
3:+ (small)
4:Center blank (small)
SAFETY ZONE OFF
1
2
For selecting the type of safety zone frame.
OFF:The safety...