Page 81
7 Chapter 7 Menu description tables 81 Item/ Data storageVariable rangeRemarks P.OFF GPS DATA HOLDCLEARFor selecting whether or not to hold the UMID GPS position information while the power is off and record the information as the data still held as the previous value until another measurement can be taken after the power is next turned on. HOLD:The data is held and recorded. CLEAR:The data is cleared at the same time as the power is turned off, and all zeros (no information) are recorded from the time...
Page 82
Chapter 7 Menu description tables 82 SDC61500h00m02s00f : 00h04m59s29f : 23h59m59s29f The shortest time is two seconds. CU F INTERVAL REC MODEON ONE SHOT OFF For setting the INTERVAL REC function. ON (MEMORY): Interval recording is possible in single- frame units using memory. ONE SHOT: Recording is performed only once for the time set in the REC TIME item, after which it stops. OFF:Interval recording is not performed. F REC TIME SDC905 00s01f : 59s29fFor setting the recording time (one cut). The...
Page 83
7 Chapter 7 Menu description tables 83 Item/ Data storageVariable rangeRemarks 7-2-4 OUTPUT SEL SC PHASE FINE–75: +00: +75 For finely adjusting the SD phase during genlock.When making GENLOCK adjustments to the unit, adjust H PHASE first, followed by SC PHASE. Item/ Data storageVariable rangeRemarks GENLOCKINT EXT 26P EXTFor selecting the sync signal among the camera signals. INT: For synchronizing with the internal reference signal regardless of the reference signal which has been supplied to the...
Page 84
Chapter 7 Menu description tables 84 7-3-2 MATRIX R GAIN–200: +000: +200 For setting the R channel gain. Item/ Data storageVariable rangeRemarks MASTER PED–200: +000: +200 For setting the master pedestal level. MASTER DTL–31: +00: +31 For setting the H detail/V detail level. MASTER GAMMA 0.35: 0.45: 0.75 For setting the master gamma in 0.01 steps. KNEE POINT 70.0%: 85.0%: 107.0% For setting the master knee position in 0.5% steps. KNEE SLOPE 0: 50: 99 For setting the knee slope. G GAIN–200: +000: +200...
Page 85
7 Chapter 7 Menu description tables 85 Mg (SAT/PHASE)–63: +00: +63 For performing the magenta color correction (saturation and hue). R (SAT/PHASE)–63: +00: +63 For performing the red color correction (saturation and hue). R-Mg (SAT/PHASE)–63: +00: +63 For performing the color correction (saturation and hue) between red and magenta. Mg-B (SAT/PHASE)–63: +00: +63 For performing the color correction (saturation and hue) between magenta and blue. 7-3-3 COLOR CORRECTION Item/ Data storageVariable...
Page 86
Chapter 7 Menu description tables 86 7-3-5 MID SETTING $MATRIX TABLEOFFA BFor selecting the color correction table. $COLOR CORRECTONOFFFor selecting ON or OFF for the color correction. Item/ Data storageVariable rangeRemarks $MASTER GAIN–3dB: 9dB: 30dB For setting the master gain to –3, 0, 3, 6, 9, 12, 15, 18, 21, 24, 27 or 30 dB. H.DTL LEVEL 00: 14: 63 For performing the H.DTL LEVEL setting. V.DTL LEVEL 00: 20: 31 For performing the V.DTL LEVEL setting. DTL CORING 00: 03: 15 For performing the DTL...
Page 87
7 Chapter 7 Menu description tables 87 7-3-7 ADDITIONAL DTL Item/ Data storageVariable rangeRemarks KNEE APE LVL OFF 1 2: 5 For performing the KNEE APE LEVEL setting. CHROMA DTL OFF1: 5 For performing the CHROMA DTL setting. The chroma edge is detected and placed on the Y signal to bolster H.DTL. The higher the number, the greater the correction. DTL GAIN(+)–31: +00: +31 For changing the DTL “+” direction level. DTL GAIN(–)–31: +00: +31 For changing the DTL “–” (down) direction level. DTL CLIP00: 63...
Page 88
Chapter 7 Menu description tables 88 7-3-9 KNEE/LEVEL Item/ Data storageVariable rangeRemarks MASTER PED–200: +000: +200 For performing the MASTER PEDESTAL setting. $MANUAL KNEEON OFFFor setting the mode which is to be established when the AUTO KNEE switch is at OFF. The KNEE POINT/SLOPE setting value is active when ON is selected. KNEE POINT 70.0%: 85.0%: 107.0% For setting the KNEE POINT position in 0.5% steps. KNEE SLOPE 00: 50: 99 (98) For performing the KNEE width setting. Same as KNEE OFF when...
Page 89
7 Chapter 7 Menu description tables 89 Item/ Data storageVariable rangeRemarks DETAILON OFFFor selecting ON or OFF for DTL (H, V). 2D LPF ONOFFFor selecting ON or OFF for the 2- dimensional LPF that reduces cross color. HIGH COLOR ONOFFFor selecting ON or OFF for the mode in which the dynamic range of the colors is expanded. TEST SAW ONOFFFor selecting ON or OFF for the test signals. FLAREON OFFFor selecting ON or OFF for the flare compensation. H-F COMPE.ON OFFFor selecting ON or OFF for the mode in...
Page 90
Chapter 7 Menu description tables 90 7-4-2 VF MARKER Item/ Data storageVariable rangeRemarks TABLEA BFor selecting the VF MARKER setting table. This item is used to set the current values of table A or B which have been selected using the menu items listed below. CENTER MARK OFF1 2 3 4For selecting the center marker. OFF:The center marker is not displayed. 1:+ (large) 2:Center blank (large) 3:+ (small) 4:Center blank (small) SAFETY ZONE OFF 1 2 For selecting the type of safety zone frame. OFF:The safety...