–91– Recording With an External VTR Instead of the Internal VTR Controlling the external VTR with the unit’s switches Setting the 26P CONTROL function as indicated below at the FUNCTION 3/5 page of the set- ting menu prevents the internal VTR from being operated and enables only the external VTR to be controlled by the VTR START button of the unit or the VTR button of the lens. Á26P CONTROL: ON ÁSee “Selecting Functions” (page 63) for a description of FUNCTION 3/5 page operations. Switching from the internal VTR to the external VTR If the internal VTR experiences problems (tapes becoming tangled, condensation, etc.) during operation and becomes unable to operate, the VTR START button of the unit and the VTR but- ton of the lens will not function. In these cases, setting the 26P CONTROL function as noted above at the FUNCTION 3/5 page allows the external VTR to be operated in place of the inter- nal VTR using the VTR START button of the unit or the VTR button of the lens. Starting recording Operate the external VTR to set it to recording paused status and press the VTR START button of the unit or the VTR button of the lens. The external VTR starts recording. Pressing the button again sets the VTR to the recording paused status. Output level of the 26-pin output adaptor When the unit is shipped from the factory, the audio level is set to p60 dBu balanced and the component video level is set to Sony level (see page 90). The audio level can be set to p20 dBu unbalanced and the component video level to MII level with an internal switch. Consult your dealer for a detailed description.
–92– RET But ton The images recorded on the VTR or return video signal which has been input to the Time code input/output/Video input adaptor AJ-YA710 (option) can be seen on the viewfinder screen when the RET (return video) button is pressed or while it is kept pressed in. What is displayed on the viewfinder screen changes as indicated in the table below according to the RET VIDEO switch setting and VTR mode. ÈLens RET button functions RET VIDEO switch Internal VTR modeDescription of what appears setting on viewfinder screen INT Recording Images shot by camera. RET button does not function. Recording paused What has been recorded (2-second rec review) can be checked. Playing Internal VTR’s playback images. RET button does not function. Playback paused Search operation for successive shooting. EXT Recording Return video signal which has been supplied to AJ-YA710 (option). Recording paused Return video signal which has been supplied to AJ-YA710 (option). Playing Return video signal which has been supplied to AJ-YA710 (option). Playback paused Return video signal which has been supplied to AJ-YA710 (option).
–93– Replacing the Backup Battery The unit is shipped from the factory with a backup battery already mounted. When the battery runs out, the TCG time code value indicates 00:00:00:00. At this time, the time code value cannot be backed up. In addition, the “BACK UP BATT EMPTY” display appears in the viewfinder for 3 seconds when the POWER switch is set to ON to indicate that the battery must be replaced. Consult your dealer when replacing the battery. Backup Battery
–94– Setting Menu Screens MARKER Screen This page sets the setting for the marker displays inside the viewfinder. Menu screen display methods USER menu:Setting the MENU switch to SET displays the USER menu. ENG menu:Holding down the SHIFT/ITEM and UP buttons simultaneously and setting the MENU switch to SET displays the ENG menu. The underlined setting in the Variable range column indicates the preset mode. ItemVariable VF Remarksrange display CENTER MARK ON USER Center mark display ON/OFF OFF ENG SAFETY ZONE OFF USER Safety zone switching/display OFF 1–6 ENG -MARKER- ¢ CENT ERMARK :ON SAFETY ZONE : 1
–95– Setting Menu Screens VF DISPLAY Screen This page sets the setting for the display information inside the viewfinder. Menu screen display methods USER menu:Setting the MENU switch to SET displays the USER menu. ENG menu:Holding down the SHIFT/ITEM and UP buttons simultaneously and setting the MENU switch to SET displays the ENG menu. The underlined setting in the Variable range column indicates the preset mode. Item DISP MODE EXTENDER SHUTTER TAPE BATTERY FILTER WHITE GAIN LEVEL METER IRIS CAMERA ID Variable range 1– 3 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF IRIS SoIRIS S OFF ON OFF VF display USER ENG USER ENG USER ENG USER ENG USER ENG USER ENG USER ENG USER ENG USER ENG USER ENG USER ENG Remarks Extender display ON/OFF Shutter speed display ON/OFF Remaining tape length display ON/ OFF Battery voltage display ON/OFF Filter No. display ON/OFF AWB PRE/A/B display ON/OFF Currently selected gain display ON/ OFF Audio level meter display ON/OFF IRIS: Only the f-number is displayed. SoIRIS: Both the super iris ON status and f-number are displayed. S: Only the super iris ON status is displayed. OFF: Neither the super iris ON status nor f-number is displayed. ID Mix ON/OFF during color bar recording Change FILTER GAIN AWB AUTO KNEE SW SHUTTER ABB ATATUS AWB STATUS Display 1 q q q q q q q 2 q q q ¿ ¿ ¿ ¿ 3 ¿ ¿ ¿ ¿ ¿ ¿ ¿ -VF D I SPLAY-¢ DISPMODE : 3 EXTENDER :ON SHUT T ER :ON TAPE :ON BA T T ERY :ON FILTER :ONWHI TE :ONGAIN :ON L EVE LMETER : CA MERA I D :ON IRIS : IS ONS+IR
–96– Setting Menu Screens CAMERA ID Screen This page performs the camera ID settings. Each time the UP button is pressed, the character display changes in the order of space, English letters (A to Z), numbers (0 to 9) and symbols [space, {, |, ), (, ’, ‘, ,, --, -, x, /, !]. Pressing the DOWN button changes the character display in the reverse order. SHUTTER SPEED Screen This page performs the shutter speed settings. The ON/OFF status for each item is indicated by displaying an asterix (E) or period (. ) in front of the item on the screen. The underlined setting in the Variable range column indicates the preset mode. Menu screen display methods USER menu:Setting the MENU switch to SET displays the USER menu. ENG menu:Holding down the SHIFT/ITEM and UP buttons simultaneously and setting the MENU switch to SET displays the ENG menu. E:ON . : OFF ItemVariable VF Remarksrange display ID:EEEEEEEEEE—— USER Camera ID input ENG Item SYNCHRO SCAN SUPER V 1/100 1/120 1/250 1/500 1/1000 1/2000 Variable range ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF VF display ENG ENG ENG ENG ENG ENG ENG ENG Remarks Synchro scan shutter speed setting SUPER V mode setting Shutter speed 1/100 setting ON/OFF Shutter speed 1/120 setting ON/OFF Shutter speed 1/250 setting ON/OFF Shutter speed 1/500 setting ON/OFF Shutter speed 1/1000 setting ON/OFF Shutter speed 1/2000 setting ON/OFF -CAMERA I D- ID:EEEEEEEEEE -SHUT TER SPEED- ¢ ES YNCHROSCAN . SUPER V E1 / 100 E1 / 120 E1 / 250 E1 / 500 E1 / 1000 E1 / 2000 |Note{ Whether or not this set value is to be mixed is selected by setting CAMERA ID on the VF DISPLAY screen to ON or OFF.
–97– Setting Menu Screens SYNCHRO SCAN Screen This page performs the synchro scan settings. ! LED Screen This page sets the ON/OFF setting for the ! LED display inside the viewfinder. The ON/OFF status for each item is indicated by displaying an asterix (E) or period (. ) in front of the item on the screen. |Note{ The ! LED lights when both GAIN (0 dB) and GAIN (p3 dB) are ON unless the gain is set to p3 dB or 0 dB. The underlined setting in the Variable range column indicates the preset mode. Menu screen display methods USER menu:Setting the MENU switch to SET displays the USER menu. ENG menu:Holding down the SHIFT/ITEM and UP buttons simultaneously and setting the MENU switch to SET displays the ENG menu.E:ON . : OFF Item SYNCHRO SCAN Variable range 1/30.4 . . . 1/61.7 . . . 1/250 VF display USER ENGRemarks Synchro shutter speed selection Item GAIN (0 dB) GAIN (p3 dB) SHUTTER WHITE PRESET EXTENDER FILTER SUPER V Variable range ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF VF display ENG ENG ENG ENG ENG ENG ENG Remarks This selects whether or not the LED is lighted when the gain is any value other than 0 dB. This selects whether or not the LED is lighted when the gain is any value other than p3 dB. This selects whether or not the LED is lighted when the shutter is ON. This selects whether or not the LED is lighted when the AWB CH is PRESET. This selects whether or not the LED is lighted when the lens is in EXTENDER mode. This selects whether or not the LED is lighted when the filter is any value other than 3200K. This selects whether or not the LED is lighted when SUPER V is ON. -S YNCHROSCAN- 1/61.7 -!LED- ¢ EGAIN(0dB) dB ) .GAIN( ESHUT T ER . WH I TE PRESET EEXTENDER . FILTER . SUPER V -3
–98– Setting Menu Screens MAIN FUNCTION Screen This page performs the adjustment function settings. BAT T/ TAPE ALARM Screen The battery end and tape end audio warnings during shooting can be switched off if they become undesirable. The underlined setting in the Variable range column indicates the preset mode. Menu screen display methods USER menu:Setting the MENU switch to SET displays the USER menu. ENG menu:Holding down the SHIFT/ITEM and UP buttons simultaneously and setting the MENU switch to SET displays the ENG menu. Item BATT NEAR END BATT END TAPE NEAR END TAPE END Variable range ON OFF ON OFF ON OFF ON OFF VF display ENG ENG ENG ENG Remarks Battery near end audio ON/OFF Battery end audio warning ON/OFF Tape near end audio warning ON/OFF Tape end audio warning ON/OFF Item PHANTOM FRONT PHANTOM CH1 PHANTOM CH2 Variable range ON OFF ON OFF ON OFF VF display ENG ENG ENG Remarks Phantom microphone (front) usage selection ON: Phantom microphone (o48 V) used. OFF: Normal microphone used. Phantom microphone (CH1) usage selection ON: Phantom microphone (o48 V) used. OFF: Normal microphone used. Phantom microphone (CH2) usage selection ON: Phantom microphone (o48 V) used. OFF: Normal microphone used. -MA I N F UNC T ION- ¢ PHANTOMFRONT :ON PHANTOMCH 1 :OFF PHANTOMCH 2 :OFF -BAT T / TAPEALARM- ¢ BA T T NEAR END :ON BAT T END :ON T APE NEAR END :ON TAPEEND :ON
–99– E:ON . : OFF Setting Menu Screens FUNCTION 1/5 Screen This page performs the adjustment function 1 settings. The ON/OFF status for each item is indicated by displaying an asterix (E) or period (. ) in front of the item on the screen. FUNCTION 2/5 Screen This page performs the adjustment function 2 settings. Item DETAIL 2D LPF SKIN TONE DTL MATRIX GAMMA TEST SAW FLARE Variable range ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF VF display ENG ENG ENG ENG ENG ENG ENG Remarks Detail (H, V) ON/OFF switching ON/OFF switching for 2-dimensional LPF (Low Pass Filter) which reduces color smear Skin tone detail ON/OFF switching Color adjustment ON/OFF switching Gamma circuit ON/OFF switching Test signal ON/OFF switching Flare compensation ON/OFF switching Item SUPER V FILTER INH SHOCKLESS AWB S.IRIS SW S.SCAN SEL Variable range OFF FRM1 FRM2 ON OFF OFF NORMAL SLOW FAST S.IRIS 30 dB OFF ON OFF VF display ENG ENG ENG ENG ENG Remarks Super V ON/OFF switching FRM1: Normal mode FRM2: Lag reduction mode Switch that determines whether AWB memory (Ach, Bch) data is stored for each filter. ON: Ach and Bch memory only (2 memory units), regardless of the filter. OFF: Data is stored for each filter. (4q2r8 memory units) Shockless AWB ON (NORMAL/SLOW/ FAST)/OFF switching U Super iris (S.IRIS)/30 dB/OFF switching Synchro scan ON/OFF switching ON: S.SCAN speed can be varied by the SUPER IRIS/MODE CHECK switch. OFF: Normal mode The underlined setting in the Variable range column indicates the preset mode. Menu screen display methods USER menu:Setting the MENU switch to SET displays the USER menu. ENG menu:Holding down the SHIFT/ITEM and UP buttons simultaneously and setting the MENU switch to SET displays the ENG menu. -F UNC T ION1/5- ¢ EDETA ILE2D LPF . SK I N TONE DTLEMATRIX EGAMMA . TEST SAWEF L ARE -F UNC T ION2/5- ¢ SUPER V : FRM1 FILTER INH :OFF SHOCK L ESS AWB:NORMAL S. IRIS SW:S.IRIS S . SCANSE L :ON USHOCKLESS AWB ensures that no shock will occur when A/B/PRST set- ting of the WHITE BAL switch is changed. FAST (high speed), NORMAL (normal speed) or SLOW (low speed) can be set as the selection time.
– 100 – Setting Menu Screens FUNCTION 3/5 Screen This page performs the adjustment function 3 settings. Item HUMID OPE 26P CONTROL REC START TC MODE UB MODE PAUSE TIMER BATTERY SEL TCG VF DISP Variable range ON OFF OFF BOTH ON ALL NORMAL DF NDF USER REAL EXT 10 20 30 NiCd-12 NiCd-13 NiCd-14 DIGITAL ON OFF VF display ENG ENG ENG ENG ENG ENG ENG ENG Remarks VTR operation selection when condensation occurs. ON: Operation continues normally. OFF: All operations prohibited except for POWER switch and EJECT button. 26P remote control selection OFF: Unit only (26P control does not function.) BOTH: Unit and 26P remote control (TALLY LED indicates unit REC status.) ON: 26P remote control only (TALLY LED indicates 26P VTR REC status.) REC acceptance selection for VTR START/STOP ALL: REC accepted regardless of VTR mode. NORMAL: REC accepted only during STOP (POWER SAVE) mode and REC PAUSE mode. Time code DF/NDF switching DF: Drop frame mode NDF: Non-drop frame mode LTC UB usage method selection USER: User setting (fixed value) REAL: Real-time operation according to the TIME DATE time EXT: When there is external TC input, the UBG value is slave locked. (When there is no external input, the user setting is used.) Selection for the recording/pause hold time. 10: 10 minutes 20: 20 minutes 30: 30 minutes Battery type selectionF NiCd-12: 12 V Nicad battery NiCd-13: 13 V Nicad battery NiCd-14: 14 V Nicad battery DIGITAL: Digital battery Viewfinder time code display ON/OFF ON: Time code is displayed. OFF: Time code is not displayed. FEven if the BATTERY SEL is selected to NiCd-12, 13 or 14, the camera automatically senses whether or not an Anton Bauer’s Intelligent Battery is fitted. In the case of an intelligent battery, a numerical indication (percentage) of power available is displayed in the viewfinder. If the camera is usually used with an intelligent battery, BATTERY SEL should be set to DIGITAL. -F UNC T ION3/5- ¢ HUMIDOPE :OFF26P CONTROL:OFFREC S T ART:NORMAL TCM MODE : DF UB MODE : USER PA SET:30 UEIR BAT TERY SE L : N i Cd-12 TCGVF D I SP :OFF