Panasonic Ac Adapter Aw Ps300 Operating Instructions
Have a look at the manual Panasonic Ac Adapter Aw Ps300 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
AC Adapter AW-PS300 Before attempting to connect or operate this product, please read these instructions completely. â
Warning: Do not install this product near any object that burns easily. In case of using a halogen lamp, installation of it near such an object could cause a fire due to the heat generated by the lamp. This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOIS TURE. The lightning flash with arrowhead sym- bol, within an equilateral triangle, is intended to alert the user to the pres- ence of uninsulated dangerous voltage within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilat- eral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appli- ance.The serial number of this product may be found on the bot- tom of the unit. You should note the serial number of this unit in the space provided and retain this book as a permanent record of your purchase to aid identification in the event of theft. Model No. Serial No. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SER- VICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PER- SONNEL. CAUTIONRISK OF ELECTRIC SHOCK DO NOT OPEN SA 1965 SA 1966 For U.S.A For CANADA
CONTENTS FEATURES ................................................................................................................................................................................... 1 PRECAUTIONS ............................................................................................................................................................................. 2 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ...................................................................................................... 3 CONNECTION .............................................................................................................................................................................. 6 SPECIFICATIONS ......................................................................................................................................................................... 8 ACCESORY ................................................................................................................................................................................... 8 -1- FEATURES• This is the AC Adapter for the Pan/tilt Head AW-PH300. • It has an AC outlet (500 W maximum) for halogen lamps that can be switched on and off from a Control Panel (AW-RP301, AW-RP305, AW-RP501, or AW- RP505). • It also has an option switch (120V, 1A maximum) whose contact can be shorted or opened from a Control Panel (AW-RP301, AW-RP305, AW-RP501, or AW-RP505).• The maximum allowable cable length between this adapter and pan/tilt head is 30 meters.
-2- • Handle the adaptor with care. Dropping the control panel or subjecting it to a strong shock can cause a failure or an accident. • Operating temperature range –10°C to +45°C Avoid using it in a cold place below –10°C or a hot place above +45°C because low or high temperature will adversely affect the parts inside. • Switch power off before power cable connection or disconnection. Be sure to switch power off before connecting or dis- connecting the power cable. • Avoid outdoor use. • Install the control panel more than 1 meter away from the monitors.• Care Pull out the power cable plug, and wipe the control panel clean with a dry cloth. If it is extremely dirty, dip a cloth into a diluted solution of kitchen detergent, squeeze it hard, and wipe the product surfaces care- fully.PRECAUTIONS • Do not use benzine, paint thinner, or other volatile liquids. • When using a chemical duster, carefully read the caution notes on its use.Note
-3- MAJOR OPERATING CONTROLS AND THEIR FUNCTIONSnFRONT PANELqPower Switch (POWER, ON/OFF) Power is switched on to supply power to the pan/tilt head when this switch is pressed to the ON position (POWER Indicator lights), and is switched off when the switch is pressed to the OFF position. wPower Indicator (POWER) Lights red when POWER ON/OFF Switch qis pressed to the ON position, and goes out when POWER ON/OFF Switch qis pressed back to the OFF position. ONPOWER OFF POWERO I FUSE(POWER) 125V 3.15A FUSEFUSE FUSE(LAMP) 125V 6.3A FUSEFUSE AC AdaptorAW-PS300 T T eFuse [FUSE (POWER)] Power fuse. Use a 125V, 3.15A fuse to replace it. rLamp Fuse [FUSE (LAMP)] Halogen lamp fuse. Use a 125V, 6.3A fuse to replace it.
-4- tAC 120V Inlet [AC IN](AC 3P Inlet) Connect the supplied AC cable. yOption Switch Terminal (OPTION SW CONTROL OUT) (2P Terminal Board) A relay switch capable of controlling the contact to short or open from a Control Panel (AW-RP301, AW- RP305, AW-RP501, or AW-RP505). The terminal board has a maximum capacity of 120 V, 1 A (AC/DC), and is valid when it is connected to OPTION SW CONTROL IN Terminal uon the pan/tilt head. uOption Switch Control Input Terminal (OPTION SW CONTROL IN) (1P Terminal Board) Connect it to OP Output Terminal on the pan/tilt head when controlling OPTION SW CONTROL OUT Terminal AC IN LAMP AC OUT100V 500W OPTION SW CONTROL OUTOPTION SW CONTROL INLAMP CONTROL OP SC DC 15V OUT- + nFRONT PANEL yto short or open, using a cable (to be locally pur- chased) with a nominal cross section of 0.3 mm 2or more that meets the UL specifications. The maximum allowable cable length is 30 meters. Applicable Wire Solid wire: ø1.02 (AWG 18) Stranded wire: 0.75 mm 2 Usable wire range Solid wire: ø0.64 to ø1.02 (AWG 22 to 18) Stranded wire: 0.3 mm 2to 0.75 mm 2 (AWG 22 to 20) Strand diameter: ø0.18 or more Standard bare end length 10 mm
-5- iLamp Control Input Terminals (LAMP CONTROL C/S) (2P Terminal Board) Connect it to LAMP CONTROL C/S Terminals on the pan/tilt head when controlling the halogen lamp con- nected to LAMP AC OUT Connector !0to switch it on and off, using a cable (to be locally purchased) with a nominal cross section of 0.3 mm 2or more that meets the UL specifications. The maximum allowable cable length is 30 meters. Applicable wire Solid wire: ø1.29 (AWG 16) Stranded wire: 1.25 mm 2(AWG 16) Usable wire range Solid wire: ø0.64 to ø1.29 (AWG 22 to 16) Stranded wire: 0.3 mm 2to 1.25 mm 2 (AWG 22 to 16) Strand diameter ø0.18 or more Standard bare end length 11 mm oDC 15V Output Terminal (DC 15V OUT +/–) (2P Terminal Board) Connect it to (DC 15V IN +/– Terminals) on the pan/tilt head with a cable (to be locally purchased) with a nom- inal cross section of 1.25 mm 2or more that meets the UL specifications. The maximum allowable cable length is 30 meters.Applicable (usable) wire Solid wire: ø1.29 (AWG 16) Stranded wire: 1.25 mm 2(AWG 16) Strand diameter ø0.18 or more Standard bare end length 11 mm !0Lamp AC Output Connector [LAMP AC OUT] (AC 3P Outlet) AC Output Connector for halogen lamps to be switched on and off from a Control Panel (AW-RP301, AW-RP305, AW-RP501, or AW-RP505). Locally pur- chase an AC plug conversion cable that matches the AC plug for the halogen lamp to be used. Connect a halogen lamp of 250 W to 500 W. If a halogen lamp of less than 250 W is connected, the LAMP Indicator on the control panel may flash to indicate a burnt bulb even though the lamp is normal.
-6- • Switch off all the devices before making any connec- tion. • Use the Pan/tilt Head AW-PH300. • Connect the DC 15V OUT Terminals [+] and [–] on this adapter to the DC 15V IN Terminals [+] and [–] on the Pan/tilt Head (AW-PH300) respectively with cables (to be locally purchased) with a nominal cross section of 1.25 mm 2or more that meets the UL specifications. The maximum allowable cable length between the adapter and pan/tilt head is 30 meters. Applicable (usable) wire Solid wire: ø1.29 (AWG 16) Stranded wire: 1.25mm 2(AWG 16) Strand diameter ø0.18 or more Standard bare end length: 11 mm • To switch on and off the halogen lamp from the control panel, connect the LAMP CONTROL Input Terminals [C] and [S] to the LAMP CONTROL Output Terminals [C] and [S] on the pan/tilt head respectively with cables (to be locally purchased) with a nominal cross section of 0.3 mm 2or more that meets the UL specifications. The maximum allowable cable length is 30 meters. Locally purchase an AC plug conversion cable that matches the AC plug for the halogen lamp to be used, and connect a halogen lamp of 250 W to 500 W to the lamp AC outlet. If a halogen lamp of less than 250 W is connected, the LAMP Indicator on the control panel may flash to indicate a burnt bulb even though the lamp is normal. CONNECTION Applicable wire Solid wire: ø1.29 (AWG 16) Stranded wire: 1.25 mm(AWG16) 2 Usable wire range Solid wire: ø0.64 to 1.29 (AWG 22 to 16) Stranded wire: 0.3 mm 2to 1.25 mm 2 (AWG 22 to 16) Strand diameter ø0.18 or more Standard bare end length: 11 mm • To control the option switch terminal to short or open from the control panel, connect the OPTION SW CON- TROL IN Terminal [OP] on the adapter to the OP Output Terminal on the pan/tilt head with a cable (to be locally purchased) with a nominal cross section of 0.3 mm 2or more that meets the UL specifications. The maximum capacity of the option switch terminal is 120V 1A (AC/DC). Applicable wire Solid wire: ø1.02 (AWG 18) Stranded wire: 0.75 mm 2 Usable wire range Solid wire: ø0.64 to 1.02 (AWG 22 to 18) Stranded wire: 0.3 mm 2to 0.75 mm 2 (AWG 22 to 20) Strand diameter ø0.18 or more Standard bare end length: 10 mm • For details on the connection, refer to the Operating Instructions.
-7- • For a detailed description of con- necting the individual devices, refer to their Operating Instructions. • Connect the supplied AC cable to the AC 120V inlet. Plug the AC cable to an AC outlet, and press the power switch on the adapter to the ON position. AC IN LAMP AC OUT100V 500W OPTION SW CONTROL OUTOPTION SW CONTROL INLAMP CONTROL OP SC DC 15V OUT- + AC Cable (supplied) 120V AC 60HzPan/tilt Head AW-PH300 Halogen Lamp Option Unit Lamp Control Cable (Nominal cross section 0.3 mm 2or more, to be locally purchased) * Unnecessary if lamp control is not needed. Option switch control cable (Nominal cross section 0.3 mm2or more, to be locally purchased) * Unnecessary if option switch control is not needed.DC cable (Nominal cross section 1.25 mm 2or more, to be locally purchased) Locally purchase an AC plug conversion cable that matches the halogen lamp AC plug. * Unnecessary if no halogen lamp is con- nected.
-8- SPECIFICATIONSSource Voltage: 120 V AC 60 Hz Input Capacity: 552W Power Output: DC 15V OUT: DC15V 2.5A, with over-current protect circuit LAMP AC OUT: 120V AC, max. 500W, min. 250W Pan/tilt head connecting cables: 5 cables (2 DC power cables, 2 lamp control cables, 1 option switch control cable) (in case of using the lamp control and option switch control functions) Maximum cable length 30 m Operating temperature: –10°C to +45°C (14°F to 113°F) Dimensions: 210(W) x 51(H) x 250(D) mm 8-1/4”(W) x 2”(H) x 9-7/8”(D) Weight: 2.5 kg(5.5 lbs.) Finish: AV Ivory baking Weight and dimensions indicated are approximate. Specifications are subject to change without notice. AC Cable .......................................................................1 pc.ACCESORY