Page 1

AC Adapter
AW-PS300
Before attempting to connect or operate this product,
please read these instructions completely.
â 

Page 2

Warning:
Do not install this product near any object that burns easily.
In case of using a halogen lamp, installation of it near such
an object could cause a fire due to the heat generated by the
lamp.
This digital apparatus does not exceed the Class A limits for
radio noise emissions from digital apparatus set out in the
Radio Interference Regulations of the Canadian Department
of Communications.
WARNING:
TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOIS
TURE.
The...

Page 3

CONTENTS
FEATURES ................................................................................................................................................................................... 1
PRECAUTIONS ............................................................................................................................................................................. 2
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS...

Page 4

-2-
• Handle the adaptor with care.
Dropping the control panel or subjecting it to a strong
shock can cause a failure or an accident.
• Operating temperature range –10°C to +45°C
Avoid using it in a cold place below –10°C or a hot
place above +45°C because low or high temperature
will adversely affect the parts inside.
• Switch power off before power cable connection or
disconnection.
Be sure to switch power off before connecting or dis-
connecting the power cable.
• Avoid outdoor use.
• Install the...

Page 5

-3-
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONSnFRONT PANELqPower Switch (POWER, ON/OFF)
Power is switched on to supply power to the pan/tilt
head when this switch is pressed to the ON position
(POWER Indicator lights), and is switched off when the
switch is pressed to the OFF position.
wPower Indicator (POWER)
Lights red when POWER ON/OFF Switch qis pressed
to the ON position, and goes out when POWER
ON/OFF Switch qis pressed back to the OFF position.
ONPOWER
OFF
POWERO    I
FUSE(POWER)
125V  3.15A...

Page 6

-4-
tAC 120V Inlet [AC IN](AC 3P Inlet)
Connect the supplied AC cable.
yOption Switch Terminal (OPTION SW CONTROL
OUT) (2P Terminal Board)
A relay switch capable of controlling the contact to
short or open from a Control Panel (AW-RP301, AW-
RP305, AW-RP501, or AW-RP505). The terminal board
has a maximum capacity of 120 V, 1 A  (AC/DC), and is
valid when it is connected to OPTION SW CONTROL IN
Terminal uon the pan/tilt head.
uOption Switch Control Input Terminal (OPTION SW
CONTROL IN) (1P Terminal...

Page 7

-5-
iLamp Control Input Terminals (LAMP CONTROL
C/S) (2P Terminal Board)
Connect it to LAMP CONTROL C/S Terminals on the
pan/tilt head when controlling the halogen lamp con-
nected to LAMP AC OUT Connector !0to switch it on
and off, using a cable (to be locally purchased) with a
nominal cross section of 0.3 mm
2or more that meets
the UL specifications.  The maximum allowable cable
length is 30 meters.
Applicable wire
Solid wire: ø1.29 (AWG 16)
Stranded wire: 1.25 mm
2(AWG 16)
Usable wire range
Solid...

Page 8

-6-
• Switch off all the devices before making any connec-
tion.
• Use the Pan/tilt Head AW-PH300.
• Connect the DC 15V OUT Terminals [+] and [–] on this
adapter to the DC 15V IN Terminals [+] and [–] on the
Pan/tilt Head (AW-PH300) respectively with cables (to
be locally purchased) with a nominal cross section of
1.25 mm
2or more that meets the UL specifications.
The maximum allowable cable length between the
adapter and pan/tilt head is 30 meters.
Applicable (usable) wire
Solid wire: ø1.29 (AWG 16)...

Page 9

-7-
• For a detailed description of con-
necting the individual devices,
refer to their Operating
Instructions.
• Connect the supplied AC cable to
the AC 120V inlet. Plug the AC
cable to an AC outlet, and press
the power switch on the adapter
to the ON position.
AC IN
LAMP AC OUT100V   500W
OPTION   SW
CONTROL OUTOPTION   SW
CONTROL INLAMP
CONTROL
OP SC
DC 15V
OUT- +
AC Cable
(supplied)
120V AC
60HzPan/tilt Head
AW-PH300
Halogen Lamp
Option Unit
Lamp Control Cable
(Nominal cross section 0.3 mm
2or
more,...

Page 10

-8-
SPECIFICATIONSSource Voltage: 120 V AC 60 Hz
Input Capacity: 552W
Power Output: DC 15V OUT: DC15V 2.5A, with over-current protect circuit
LAMP AC OUT: 120V AC, max. 500W, min. 250W
Pan/tilt head connecting
cables: 5 cables (2 DC power cables, 2 lamp control cables, 1 option switch control cable)
(in case of using the lamp control and option switch control functions)
Maximum cable length 30 m
Operating temperature: –10°C to +45°C (14°F to 113°F)
Dimensions: 210(W) x 51(H) x 250(D) mm
8-1/4”(W) x 2”(H)...