Page 21
38 OPM-4240 / OPM-4240R 39 Infinitely Expandable Go to "Control" in menu bar → PC Tracking → Auto in order to run "Tracking Auto" window. y In case alignment doesn't work through "Tracking Auto" command, y users can tune finely through "Tracking Manual". Go to "Control" of menu bar → PC Tracking → Manual or press "Ctrl+M" using keyboard. "Tracking Manual" window enables users to set Frequency, Phase, y LineStart and PixelStart. When...
Page 22
40 OPM-4240 / OPM-4240R 41 Infinitely Expandable 5.14. BiC Control You can control BIC functions related with burn-in compensation. y Please select "Menu → Control → BIC Control" or "Ctrl+B" to start BIC control. y Select one of BIC mode, BYPASS mode, REGENERAION mode and ANTI IMAGE STICKING mode and y click “EXE” to control Burn-in compensation function. 1.BICOn/Off BiC Mode:1) Activate BIC function to reduce burn-in effect. (BIC function On) BYPaSS Mode:2)...
Page 23
42 OPM-4240 / OPM-4240R 43 Infinitely Expandable Phosphor Update function changes phosphor value. y If you cannot have satisfactory compensation result by adjusting Deterioration function, you can change phosphor value. Deterioration function adjusts deterioration range for Red, Green and Blue respectively. y Set up Test pattern-Red, Green, Blue and "SCREEN" external image source, to control Deterioration.1) Adjust Deterioration range for Red, Green and Blue respectively. 2)...
Page 24
44 OPM-4240 / OPM-4240R 45 Infinitely Expandable How to Control BiC 1.MSCS 1) MSCS and MPDP must be always connected. 2) If MSCS command is executed prior to the BIC command, the BIC command will be executed again one hour later. 3) Turn off the energy save mode of the computer. 4) The compensation for undesirable burn-in effect is made automatically when BIC function is executed. If the compensation result is not satisfactory, use additional Burn-in compensation function in MSCS. (Please see...
Page 25
46 OPM-4240 / OPM-4240R 47 Infinitely Expandable MF-Controller configuration method 1. Connect power. 2. Connect female D-sub to the Com port in a computer. 3. Connect male D-sub to the RS-232C port in MPDP. 4. Set the number of the connected MPDP units in advance. The number can be set only by the Remote controller. 5. Set the switch at REMOCON side DC 5~9V BOOSTER REMOCONTO PDP FROM PC 아답터 연결잭(5V 1A 사용) MPDP연결PC연결 BOOSTER 또는 REMOCON 선택 스위치 ※note Select BOOSTER for a booster and BIC functions....
Page 26
48 OPM-4240 / OPM-4240R 49 Infinitely Expandable 8. Press "UP" and "DOWN" buttons to begin vertical configuration.(▲▼) Press the button for the number of the MPDP units and the same number of LEDs are turned on from the right side. (In case of 2X2, press button.) 2sets are selected. 9. Press "GO" button to finish configuration mode. (Configuration finish & save) 10. The rightmost LED (T.P.) is turned on when MF Controller starts BIC communication. If this LED blinks,...
Page 27
50 OPM-4240 / OPM-4240R 51 Infinitely Expandable Introduction1. This document contains the communication protocol between PDP and its control devices such as computer for better use of the product. However, it does not include detailed technical matters. It rather focuses on t\ he brief functional explanation and communication protocol. ID:1 Controller Tx/Rx Line ID:2ID:N-1ID:N ID:N+1 ID:N+N ID:(M-2)N+1 ID:(M-2)N+N ID:(M-1)N ID:(M-1)N+2 ID:(M-1)N+N-1ID:MXN ※ Connection formation can be vary based on...
Page 28
52 OPM-4240 / OPM-4240R 53 Infinitely Expandable Multi-Scale3.3. Screen expansion command for MPDP -Command Code -0xDD (DVI), 0xDE (PC), 0xDF (DTV), 0xE0 (DVD), 0xE1(S-Video), 0xE2 (Video)One way communication (Send to PDP) -Data: ID (1 byte) +X/Y(1 byte) + P(1 byte) -X: the number of horizontally installed MPDP Y: the number of vertically installed MPDP P: the location of expanded scaleX/Y: upper position 4bits - X (Max: 15), lower position 4bits - Y (Max: 15)e.g.) 0x44 for 4 x 4 screens, 0xFF for...
Page 29
54 OPM-4240 / OPM-4240R 55 Infinitely Expandable Tracking Mode3.9. Automatic or Manual screen alignment or open previous configuration at PC RGB Mode. -Command Code: -0x4A (Auto-tracking), 0x4B (Get Tracking Values), 0x4C (Frequency- tracking), 0x4D (Phase-tracking), 0x4E (Line-Start tracking), 0x4F (Pixel-Start tracking)Protocol format for each command -:Get Tracking Values - Two way communication (Send to PDP, Receive from PDP)①SendtoPDP STXCMDLengthIDETX 1 byte1 byte1 byte1 byte1 byte...
Page 30
56 OPM-4240 / OPM-4240R 57 Infinitely Expandable Elapsed Time3.14. Command for finding out how long the set was actually used. -Command code: 0x78 -Protocol Format: - two way communication (Send to PDP, Receive from PDP) -*SendtoPDP STXCMDLengthIDETX 1 byte1 byte1 byte1 byte1 byte Data: ID(1 byte) -*ReceiveFromPDP STXCMDLengthDataCheck SumETX 1 byte1 byte1 byte7 byte1 byte1 byte Data: ID(1 byte) + Elapsed Time Data(5 byte) -Elapsed Time Data -Data 0: position for hundred...