Nitsuko Portrait 308 Hardware Manual
Here you can view all the pages of manual Nitsuko Portrait 308 Hardware Manual. The Nitsuko manuals for Telephone are available online for free. You can easily download all the documents as PDF.
Page 61
VOICEMAIL 4-25 Using Voice Mail (Figure 4-15) The Portrait System is compatible with the NVM-202ex or NVM-22 (P/N 17590A) Voice Mail Systems. This feature provides telephone users with comprehensive Voice Messaging and Auto Attendant capabilities. The system has a capacity of five voice mail ports. System Requir ements: l NVM-202ex (P/N 17670) software 6.01 or higher OR NVM-22 (P/N 17590A) software 7.01 or higher Voice Mail Units. l Portrait 308 with software version 1.00 or higher. NOTE: The Voice...
Page 62
VOICE MAIL 4-26 ORN-WHTto YELLOWlug 5.Back at the MDF, run two pairs of cross-connect wires between the pins on the B block and cross-connect block to complete the connection. 6.Install bridging clips as required. 7. Using a four-conductor line cord, connect the first modu- lar jack to ÒLINE1Ó on the Voice Mail Interface. Then, connect the second modular jack to ÒLINE2Ó on the Voice Mail Interface. If ÒLINE1Ó fails due to improper installation for an equipment problem, ÒLINE2Ó will not function. 8....
Page 63
VOICEMAIL 4-27 Figure 4-15 INSTALLING VOICE MAIL BLK RED GRN BLU-WHTORN-WHTWHT-ORN WHT-BLU 8240 - 62a YEL BLK RED GRN BLU-WHTORN-WHT WHT-ORN WHT-BLUYEL BLU-WHT ORN-WHT WHT-ORNWHT-BLU BLU-WHT ORN-WHT WHT-ORNWHT-BLU 25-Pair Cable to Portrait KSU Extension Modular JackExtension Modular Jack Twisted Pair Station Cable VOICE MAIL INTERFACE VOICE MAILLINE2LINE1 4-Conductor Line Cord NVM-22Connector for Ports 1 and 2 NVM-202ex Connector for Ports 1 and 2 HDWRY1-Aa.QXD 10/15/97 7:44 AM Page 4-27
Page 64
WALL MOUNT KITS 4-28 Using the Wall-Mount Kit You can use a wall-mount kit to attach any key telephone to a wall. The wall-mount kit includes a mounting bracket, wall-mount screws and a handset hanger. When a phone is wall-mounted, the directory tray located beneath the phone can not be used. Note: The wall-mount kit currently does not accommodate installing on a wall plate. Installing the Wall-Mount Handset Hanger (Figure 4-16) 1. Insert the handset hanger in the slot provided beneath the telephoneÕs...
Page 65
WALLMOUNT KITS 4-29 Wall-Mounting a Key Telephone (Figure 4-17) 1.Mount the wall-mount kitÕs plastic bracket in the desired location using the screws provided. 2.Insert the telephoneÕs line cord from the 625 modular jack through the plastic bracket using the space provided in the bracket. 4.Place the telephone on top of the plastic bracket on the clips provided. Gently push the bottom of the bracket in until it snaps into the slots on the phone. Figure 4-17 INSTALLING THE WALL MOUNT BRACKETS 82400 - 33...
Page 67
5-1 Section 5 Specifications and Parts List In this section. . . Page Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . .5-3 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-7 5. Specifications and Parts List HDWRY1.QXD 10/21/97 8:33 AM Page 5-1
Page 69
SPECIFICATIONS 5-3 System Capacities Tenant Groups: 4 Cabinets: 1 Talk Timeslots (Intercom/line): 2 Analog Trunks (CO/PBX lines): 3 Electronic Key and/or Analog Telephones: 8 (6 single line telephones maximum) Power Failure Telephones: 1 Door Boxes: 2 Door Box/Music On Hold Relays: 2 Alarm Sensors: 1 External Paging Zones: 1 Internal Paging Zones: 4 Speed Dial, Personal: 10 Speed Dial, System: 100 Caller ID Circuits: 3 Voice Mail Ports: 5 PCBs Auxiliary PCB: 1 Caller ID PCB: 1 CPU Central Processing...
Page 70
SPECIFICATIONS 5-4 Power Requirements A dedicated 110 VAC 60 Hz 15 amp circuit (terminated in a NEMA 5- 15R receptable) located within six feet of the cabinet is required. You should install a separate dedicated outlet for each cabinet. Environmental Specifications Cabinets and Key TelephonesDoor Box Temperature: 0-45oC (32-113oF)Temperature: -20-60oC (-4-140oF) Humidity: 10-95% (non-condensing)Humidity: 10-95% (non-condensing) Electrical Specifications Power Supply:110 VAC ±- 10% @ 50-60 Hz 15 amps...