EXTERNALPAGING AND PAGE RELAYS Using External Paging The Auxiliary PCB has one External Paging audio output and one associated control relay. You connect the audio out- put to the audio input on customer-provided paging systems. In some paging systems, you can use the control relay to automatically turn the amplifier on and off. The control relay is normally opened and closes whenever a user calls the External Paging zone. Installing External Paging and Page Relay (Figure 4-4) CAUTION Be sure the audio...
Page 42
EXTERNALPAGING AND PAGE RELAYS 4-6Figure 4-4 CONNECTING EXTERNAL PAGING/RELAY Figure 4-5 CONNECTING EXTERNAL PAGING One-Pair Cross-Connect DDK Connector To External Page audio output on Auxiliary PCB 25-Pair DDK Installation CableC Block Cross Connect BlockOutput to paging system control inputs 82400 - 10 One-Pair Cross-Connect DDK Connector To Control Relay on Auxiliary PCB 25-Pair DDK Installation CableC Block Cross Connect BlockOutput to paging system control inputs 82400 - 9 HDWRY1-Aa.QXD...
Page 43
EXTERNALPAGING AND PAGE RELAYS 4-7 Figure 4-6 CONNECTING CONTROL RELAYS TO THE AUXILIARYPCB 82500 - 13 Auxiliary PCB DH2 DH1 EXMOH SPK CTR RL2 RL1(DH2)(DH1)(SPK) VR4VR3VR1 ARM (MOH) EXT INT SW1 Amplifier Paging Speaker HDWRY1-Aa.QXD 10/15/97 7:44 AM Page 4-7
Page 44
DOOR BOX 4-8 Using the Door Box Each Auxiliary PCB supports two Door Boxes. In addition, you can connect each circuitÕs control relay to an electric door strike. This allows an extension user to remotely activate the door strike while talking to a visitor at the Door Box. The control relays are normally open. Installing a Door Box (Figure 4-7) 1. Locate an available 2-pin DDK connector in an auxiliary (C) block. 2. For the DDK connector chosen, cross-connect the associated wire pair from the C block to...
Page 45
DOOR BOX 4-9 Figure 4-7 CONNECTING A DOOR BOX 15 6 L C T T 234LF To Door Chime Box 1Rear view To Door Chime Box 221 22 23 24 * typical installation RED-BRN BRN-RED RED-SLT SLT-RED* * Misc Block Holes for mounting screws 920 - 159A HDWRY1-Aa.QXD 10/15/97 7:44 AM Page 4-9
Page 46
DOOR BOX 4-10 Installing Door Strike Control Relays(Figure 4-8) CAUTION Be sure the requirements of the door strike are compatible with the control relay output specifications of the system. Contact Configuration: Normally open MaximumLoad: 250 mA@ 24 VDC Maximum Initial Contact Resistance: 50 mOhms 1.Locate an available 2-pin DDK connector in an auxiliary (C) block. 2.For the DDK connector chosen, cross-connect the associ- ated wire pair from the C block to the cross-connect block. 3.Connect two leads...
Page 47
DOORBOX 4-11 Figure 4-8 CONNECTING TO THE DOOR STRIKE Figure 4-9 CONNECTING DOOR BOX/DOOR STRIKE RELAYS TO THE AUXILIARYPCB 82500 - 12 Auxiliary PCB To Door Strike Terminals DH2 DH1 EXMOH SPK CTR RL2 RL1(DH2)(DH1)(SPK) VR4VR3VR1 ARM (MOH) EXT INT SW1 Door Box One-Pair Cross-Connect DDK Connector To Control Relay on Auxiliary PCB 25-Pair DDK Installation CableC Block Cross Connect BlockOutput to door strike 82400 - 8 HDWRY1-Aa.QXD 10/15/97 7:44 AM Page 4-11
Page 48
MUSIC SOURCES 4-12 Music on Hold Music on Hold (MOH) provides music to callers on Hold. The systemÕs default setting provides an internal (synthe- sized) MOH music source, or a customer-provided music source connected to the Auxiliary PCB can be used instead. There are two jumpers that determine whether or not the system will play Music on Hold. The first jumper is located on the CPU and is labeled SW2. This jumper should be set to the ON position. If it is not, it overrides the setting of the SW1...
Page 49
MUSIC SOURCES 4-13 Figure 4-10 CONNECTING MUSIC SOURCES Figure 4-11 CONNECTING TO THE AUXILIARY PCB 82500 - 11 External MOH Source Auxiliary PCB The relay contacts RL1 and RL2 can be used as a MOH device control. The remote control terminal on the device must be connected to these contacts (see PROGRAM 56). DH2 DH1 EXMOH SPK CTR RL2 RL1(DH2)(DH1)(SPK) VR4VR3VR1 ARM (MOH) EXT INT SW1 82500 - 3 One-Pair Cross-Connect To MOH on Auxiliary PCBTo music source DDK Connector25-Pair DDK Installation CableC...
Page 50
CALLER ID 4-14 Using the Caller ID Feature Each Auxiliary PCB supports the use of Caller ID on the three CO lines in the system. Caller ID allows a display key- set to show an incoming callerÕs telephone number and/or name with the time and date on the phoneÕs display. The callerÕs information can be checked before answering an incoming call. The information received by the system depends upon the capabilities of your local telco. Connecting Caller ID (Figure 4-12) 1.With two 2-pin DDK connectors (one...