Page 61
5. Maintenance Options and SMDR 5-5 MODEM INSTALLATIONFigure 5-2 CONNECTING A MODEM 80200 - 24 RS-232 Port Mod 8 Patch CordTo trunk Modem Power SupplyP/N 85981
Page 62
5-6 MAKING YOUR OWN DATA CABLES 80200 - 35 1Mod-8 1 2 3 4 5 6 7 8 DSR DCD DTR SG RD TD CTS RTSDTR DCD DSR SG TD RD RTS CTS R1 DB-9 4 1 6 5 3 2 7 8 98 9 6 5 1 80200-36 1 8 14 25 1 13 Mod-8 1 2 3 4 5 6 7 8 DSR DCD DTR SG RD TD CTS RTSDSR DCD DTR SG RD TD CTS RTS DB-25 6 8 20 7 3 2 5 4 Figure 5-3 MAKING YOUR OWN DATA CABLES DSRMod-8 Mod-8 Latch faces down 1 RTS 2RD 3SG 4TD 5CTS 6DTR 7DCD 81 2 3 4 5 6 7 8 8 18 1 80200 - 25
Page 63
5. Maintenance Options and SMDR 5-7 SYSTEM RESET Resetting Your System (Figure 5-4) You may need to reset your system for troubleshooting purposes.To reset your system: 1. Make sure the RUN/LOAD switch is set to RUN. 2. Following the illustration at right, press the red reset switch. Your system will automatically restart. FIGURE 5-4 RESETTING YOUR SYSTEM Reset Switch 80200 - 31 RUN/LOAD Switch
Page 65
6. Specifications and Parts 6-1 Section 6, SPECIFICATIONS AND PARTS LIST In this section . . . PageSpecifications . . . . . . . . . . . . . . . . . . . . . . .6-2 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . .6-6
Page 66
6-2 SPECIFICATIONS System Capacities Power Failure Telephones: 1 DSS Consoles: 1 max. per keyset, 4 max. per system External Paging Zones: 1 Internal Paging Zones: 8 (7 and All Call) Page Audio Output: 1 Music Input: 1 Conference Circuits Conference circuits dynam- ically allocated, with 8 par- ties max. per Conference. REJ Recording Jack Units 1 max. per keyset System Capacities Cabinets: 1 Talk Timeslots (Intercom/line): Non-blocking Analog Trunks (CO/PBX lines): Base: 3 Expansion: 3 Total: 6 Digital...
Page 67
6. Specifications and Parts 6-3 SPECIFICATIONS Electrical Specifications Power Supply: 120 VAC ±- 10% @ 50-60 Hz Output Power 35 W Input Current 550 mA VA 6 6 VA Kwh .066 KwH BTU 225 BTU Grounding Requirements: 12 AWG copper wire Environmental Specifications Cabinet, Key Telephones and Digital Door Box Temperature: 0-45 oC (32-113 oF) Humidity: 10-95% (non-condensing) Digital Door Box not intended for outdoor installation. Analog Door Box Temperature: -20-60 oC (4-140 oF) Humidity: 10-95%...
Page 68
6-4 SPECIFICATIONS Relay Contacts Contact Configuration: Normally open Maximum Load: 0.5A @ 120 VAC 1A @ 24 VDC Maximum Carry Current 2A Maximum Switched Voltage 120 VAC or 60 VDC Maximum Switched Power 60 VA or 24 W Minimum Switched Current 1 mA Minimum Switched Voltage 1 VDC Minimum Switched Power 0.05 mW Maximum Initial Contact Resistance: 100 mOhms External Paging Output Impedance: 600 Ohm Output Level: 0 dBr @ 1.0 KHz Mechanical Specifications Equipment Width Depth Height Weight Cabinet 13 3/4””2...
Page 69
6. Specifications and Parts 6-5 SPECIFICATIONS Cabling Requirements 1. Do not run station cable parallel with the AC source, telex or com- puter, etc. If the cables are near cable runs to those devices, use shielded cable with grounded shields or install the cable in conduit. 2. When cables must be run on the floor, use cable protectors. 3. Cable runs for key telephones, single line telephones, Door Boxes and 3-ACI Modules must be a dedicated, isolated cable pair.Device Cable Type Cable Run Length (ft)...
Page 70
6-6 PARTS LIST Common Equipment Description Part Number DS1000 3 x 8 x 4 Cabinet 80200 DS1000 3 x 8 x 4 Expansion Board 80221 DB9 to Mod-8 Adaptor 85980 DB25 to Mod-8 Adaptor 85981 Peripheral Station Equipment Description Part Number Digital Door Box 80560 Analog Door Box 92245 Station Equipment Description Part Number 34-Button Super Display Telephone 80673 34-Button Display Telephone 80663 22-Button Telephone 80570 22-Button Display Telephone 80573 24-Button DSS Console 80556 110-Button DSS Console...