    							Diagnostics and Troubleshooting 71
     ProSAFE 8-Port and 16-Port Gigabit Click Switch
    The Switch Information screen displays.
    6.  Select  System > Monitoring > Cable T
     ester.
    7. Select one or more check boxes.
    8.  Click the  T
     est Selected Port button.
    The switch tests the cable connection for the selected port and displays\
     the results.
    Resolve a Subnet Conflict to Access the Switch
    If you power on the switch before you connect it to a network that inclu\
    des a DHCP server, 
    the switch uses its own default IP address of 192.168.0.239. This subnet might be different 
    from the subnet used in your network. You might see the following message if you try to use 
    the ProSAFE utility to access the switch:
    The switch and manager IP address are not in the same subnet.
    To fix this subnet conflict:
    1.  Disconnect the Ethernet cable between the switch and your network.
    2.  Unplug the switch’
     s power cord.
    3.  Reconnect the Ethernet cable between the switch and your network.
    4.  Plug the switch’
     s power cord into an electrical outlet.
    The switch powers on. The network DCHP server discovers the switch and assigns it an  IP address that is in the correct subnet for the network. 
    						
    							72
    A
    A.   Supplemental Information
    This appendix covers the following topics: 
    •Factory Default Settings
    •Technical Specifications 
    						
    							 Supplemental Information73
     ProSAFE 8-Port and 16-Port Gigabit Click Switch
    Factory Default Settings
    You can return the switch to its factory settings. Use the end of a paper\
     clip or some other 
    similar object to press and hold the 
    /Factory Defaults button on the back panel of the switch 
    for at least four seconds. The switch resets, and returns to the factory settings that are shown 
    in the following table.
    Table 2.  Factory default settings
    Factory Default SettingGSS108EGSS116E
    Switch name  N/A (empty)N/A (empty)
    Switch password passwordpassword
    IP address 192.168.0.239192.168.0.239
    Subnet mask 255.255.255.0255.255.255.0
    Gateway address 192.168.0.254192.168.0.254
    DHCP mode EnabledEnabled
    Port mirroring DisabledDisabled
    Loop detection DisabledDisabled
    IGMP snooping EnabledEnabled
    Port LED control Link speed and activityLink speed and activity
    LAG N/ADisabled
    VLAN DisabledDisabled
    QoS 802.1p/DSCP based802.1p/DSCP based
    Rate limit DisabledDisabled
    Broadcast filtering DisabledDisabled
    Port mode Auto negotiation Auto negotiation
    Flow control DisabledDisabled 
    						
    							 Supplemental Information
    74 ProSAFE 8-Port and 16-Port Gigabit Click Switch 
    Technical Specifications
    Table 3.  Technical specifications
    SpecificationGSS108EGSS116E
    Network interface RJ-45 connector for
    10BASE-T,
    100BASE-TX, or
    1000BASE-TRJ-45 connector for
    10BASE-T,
    100BASE-TX, or
    1000BASE-T
    Network cable Category 5e (Cat 5e) or better 
    Ethernet cableCategory 5e (Cat 5e) or better 
    Ethernet cable
    Ethernet ports 8 16
    USB ports (provides power 
    only)2–
    USB power 10W maximum per port 
    15 maximum total–
    Power 100–240 VAC 50/60Hz, 1.0A
    maximum100–240 VAC 50/60Hz, 0.5A
    maximum
    Power consumption 20.14W maximum 8.36W maximum
    Weight 0.43 kg (0.94 lb) 1.3 kg (2.64 lb)
    Dimensions (W X D x H) 305 mm x 65 mm x 36 mm
    12 in. x 2.54 in. x 1.39 in.407 mm x 70 mm x 36 mm
    16.02 in. x 2.7 in. x 1.39 in
    Operating temperature 0–40°C (32–104°F) 0–40°C (32–104°F)
    Operating humidity 0%–90% relative humidity,
    noncondensing0%–90% relative humidity,
    noncondensing
    Electromagnetic CE Class B, FCC Class B, VCCI
    Class B, RCM Class BCE Class B, FCC Class B, VCCI
    Class B, RCM Class B
    Safety agency approvals CE mark, CB CE mark, CB 
    						