English-29 English 3. Press the “DISPLAY” button on the remote control while aiming at the “PRIMARY” monitor. The Information OSD will be shown at top left side of the screen. Monitor ID: Displays the ID number of the current monitor within the daisy chain. Target ID: Displays the ID number of the monitor that to be controlled via daisy c\ hain from the current monitor. Press the “+” or “-” buttons to change the “Target ID” to show the ID number of the monitor to be controlled. To control the e ntire daisy chained monitors simultaneously, select “ALL” as the “Target ID.” 4. Use the wireless remote controller to control the “SECONDARY” monitor while aiming at the “PRIMARY” monitor. The “MENU OSD” will appear on the selected target monitor. NOTE: If the “ID No.” mode select OSD is showing, press the “DISPLAY” button on the remote control while pointing at the “PRIMARY” monitor to clear this OSD. HINT: If you lost control due to the incorrect setting of “IR CONTROL”, \ pressing the “DISPLAY” button on the remote control for 5 or more seconds will reset the “IR CONTROL” menu to “NORMAL” fu\ nction.
English-30 This LCD monitor can be controlled by connecting a personal computer wit\ h a RS-232C terminal. NOTE: When you use this function, EXTERNAL CONTROL should be “RS-232C” (See page 23). Functions that can be controlled by a personal computer are: • Power ON or OFF • Switching between input signals Connection LCD Monitor + PC RS-232C Cable PC (Out) RS-232C CableRS-232C (OUT) MultiSync RS-232C (IN) RS-232C (OUT) RS-232C (IN) IN OUT MultiSync MultiSync NOTE: If your PC is equipped only with a 25-pin serial port connector, a 25-pin serial port adapter is required. Contact your dealer for details. Check the “ID=ALL REPLY” setting in “EXTERNAL CONTROL”. * In order to function, the RS-232C OUT terminal can only be connected to another monitor of the same model. Do not connect to other types of equipment. To control monitor or multiple monitors that are daisy-chained together p\ lease use the control command. Instructions for the control command can be found on the CD included with the display. The fi le is called “External_control.pdf”. Multiple monitors that are daisy-chained have a limit to the conectable \ monitor. 1) Interface PROTOCOL RS-232C BAUD RATE 9600 [bps] DATA LENGTH 8 [bits] PARITY BIT NONE STOP BIT 1 [bit] FLOW CONTROL NONE This LCD monitor uses RXD, TXD and GND lines for RS-232C control. The reverse type cable (null modem cable) (not include) should be us\ ed for RS-232C control. Controlling the LCD monitor via RS-232C Remote Control
English-31 English 2) Control command diagram For other commands, please see “External_Control.pdf” fi le on the CD-ROM. Function (Monitor ID = 1) Code Data Power ON 01 30 41 30 41 30 43 02 43 32 30 33 44 36 30 30 30 31 03 73 0d Power OFF 01 30 41 30 41 30 43 02 43 32 30 33 44 36 30 30 30 34 03 76 0d Input Source Select DisplayPort 01 30 41 30 45 30 41 02 30 30 36 30 30 30 30 46 03 04 0d Input Source Select DVI 01 30 41 30 45 30 41 02 30 30 36 30 30 30 30 33 03 71 0d Input Source Select VGA 01 30 41 30 45 30 41 02 30 30 36 30 30 30 30 31 03 73 0d Input Source Select HDMI 01 30 41 30 45 30 41 02 30 30 36 30 30 30 31 31 03 72 0d Input Source Select DVD/HD 01 30 41 30 45 30 41 02 30 30 36 30 30 30 30 43 03 01 0d Input Source Select VIDEO 01 30 41 30 45 30 41 02 30 30 36 30 30 30 30 35 03 77 0d Input Source Select S-VIDEO 01 30 41 30 45 30 41 02 30 30 36 30 30 30 30 37 03 75 0d Input Source Select OPTION 01 30 41 30 45 30 41 02 30 30 36 30 30 30 30 44 03 06 0d Sound Mute ON 01 30 41 30 45 30 41 02 30 30 38 44 30 30 30 31 03 09 0d Sound Mute OFF 01 30 41 30 45 30 41 02 30 30 38 44 30 30 30 32 03 0a 0d
English-32 Connecting to a Network Using a LAN cable allows you to specify the Network Settings and the Alert Mail Settings by using an HTTP server function. NOTE: When you use this function, EXTERNAL CONTROL should be “LAN” (See page 23). To use a LAN connection, you are required to assign an IP address. Example of LAN connection: Server Hub NOTE: Use a category 5 or higher LAN cable. LAN cable (not supplied) Network Setting by Using an HTTP Browser Overview Connecting the monitor to a network allows for monitor control from a co\ mputer via the network. To perform the monitor control from a web browser, you must have an exclusive application installed on your computer. The IP address and subnet mask of the monitor can be set on the Network Settin\ g screen of the web browser by using an HTTP server function. Please be sure to use “Microsoft Internet Explorer 6\ .0” or a higher version for the web browser. (This device uses “JavaScript” and “Cookies” and the browse\ r should be set to accept these functions. The setting method will vary depending on the version of browser. Please refer to the help fi les and the other information provided in your software.) Access is gained to the HTTP server function by starting the Web browser on the computer via the network connected to the monitor and entering the following URL. Network Setting http:///index.html TIP: The default IP address is “192.168.0.10”. The exclusive application can be downloaded from our website. NOTE: If the MONITOR NETWORK SETTINGS screen does not appear in the web browser, press the Ctrl+F5 keys to refresh your web browser (or clear the cache). The display or button’s response can be slowed down or operation may not be accepted depending\ the settings of your network. Should this happen, consult your network administrator. The LCD monitor may not respond if its buttons are repeatedly pressed in\ rapid intervals. Should this happen, wait a moment and repeat. If you still can’t get a response, turn the monito\ r off and then back on. Controlling the LCD monitor via LAN Control
English-33 English Preparation Before Use Connect the monitor to a commercially available LAN cable before engagin\ g in browser operations. Operation with a browser that uses a proxy server may not be possible de\ pending on the type of proxy server and the setting method. Although the type of proxy server will be a factor, it is possible that items that have actually been set will not be displayed depending on the effectiveness of the cache, and the contents set from the browser may not \ be refl ected in operation. It is recommended that a proxy server not be used unless it is unavailab\ le. Handling of the Address for Operation via a Browser The host name can be used under the following cases: If the host name corresponding to the IP address of the monitor has been registered to the domain name server (\ DNS) by the network administrator, you can then access the network settings of the display via that regis\ tered host name using a compatible browser. If the host name corresponding to the IP address of the monitor has been confi gured in the “HOSTS” fi le of the computer being used, you can then access the network settings of the display via that h\ ost name using a compatible browser. Example 1: When the host name of the monitor has been set to “pd.nec.co.jp”, \ access is gained to the network setting by specifying http://pd.nec.co.jp/index.html for the address or the entry column of the URL. Example 2: When the IP address of the monitor is “192.168.73.1”, access is gained to the\ mail alert settings by specifying http://192.168.73.1/index.html for the address or the entry column of the URL. Network Settings http:// /index.html DHCP Enabling this option automatically assigns an IP address to the monitor from your DHCP server. Disabling this option allows you to register the IP address or subnet mask number obtained from your network administrator. NOTE: Consult your network administrator for the IP address when [ENABLE] is selected for [DHCP]. IP v4 Address Set your IP address of the network connected to the monitor when [DISABLE] is selec\ ted for [DHCP]. Subnet Mask Set your subnet mask number of the network connected to the monitor when\ [DISABLE] is selected for [DHCP]. Default Gateway Set your default gateway of the network connected to the monitor when [D\ ISABLE] is selected for [DHCP]. Primary DNS Set your primary DNS settings of the network connected to the monitor. Secondary DNS Set your secondary DNS settings of the network connected to the monitor. Apply Refl ect your settings. NOTE: Make sure to execute “the reboot” from the “reboot screen” o\ r to turn the monitor off and then back on to enable the changing, after clicking [Apply]. NOTE: The following settings will reset back to the factory setting when “L\ AN reset” is selected by an EXTERNAL CONTROL of OSD: [DHCP]: DISABLE, [IP v4 Address]: 192.168.0.10, [Subnet Mask]: 255.255.255.0, [Default Gateway]:\ 192.168.0.1 but [Primary DNS] and [Secondary DNS] are not changed.
English-34 Alert Mail Setting http:///lanconfi g.html This option notifi es your computer of an error message via e-mail when using wired LAN. An error message notifi cation will be sent when an error occurs in the monitor. Alert Mail Checking [ENABLE] will turn on the Alert Mail feature.Checking [DISABLE] will turn off the Alert Mail feature. Host Name Type in the hostname of the network connected to the monitor. Up to 60 alphanumeric characters can be used. Domain Name Type in the domain name of the network connected to the monitor. Up to 60 alphanumeric characters can be used. Sender’s Address Type in the senders address. Up to 60 alphanumeric and symbols characters\ can be used. SMTP Server Type in the SMTP server name to be connected to the monitor. Up to 60 alphanumeric characters can be used. Recipient’s Address 1 to 3 Type in your recipient’s address. Up to 60 alphanumeric and symbols characters can be used. Authentication Method This selects the authentication method of the e-mail transmission. POP3 Server This specifi es the address of the POP3 server that is used in the authentication of \ the e-mail. User Name This sets the user name for logging into the authentication server when \ authentication is required for the e-mail transmission. Up to 60 alphanumeric characters can be use\ d. Password This sets the password for logging into the authentication server when a\ uthentication is required for the e-mail transmission. Up to 60 alphanumeric characters can be used. TestMail Click this button to send a test mail to check if your settings are corr\ ect. Apply Click this button to refl ect the above settings. NOTE: Make sure to execute “the reboot” from the “reboot screen” o\ r to turn the monitor off and then back on to enable the changing, after clicking [Apply]. NOTE: • If you execute a test, you may not receive an Alert mail. Should this happen, check if the network settings are correct. • If you entered an incorrect address in a test, you may not receive an Alert mail. Should this happen, check if the Recipient’s Address is correct. TIP: The Alert Mail settings will not be affected even when [RESET] is done from the menu. For Control command diagram, please see fi le “External_Control.pdf” on the CD-ROM.
English-35 English Alert error message list Error number* ErrorCode Alert mail Message Explanation Measure 70h ~ 7Fh The monitor’s power supply is not functioning normally. Standby power Abnormal Please contact your supplier. 80h ~ Fh The cooling fan has stopped. Cooling fan Abnormal Please contact your supplier. 90h ~ 9Fh The monitor’s back light unit is not functioning normally. Backlight abnormal Please contact your supplier. A0h ~ AFh The monitor is overheated. Temperature Abnormal Please contact your supplier. A2h SENSOR reached at the temperature that the user had specifi ed. *condition: DISPLAY PROTECTION-FAN CONTROL-COOLING FAN = AUTOReconfi rm the setting condition from OSD (DISPLAY PROTECTION-FAN CONTROL) or please contact your supplier. B0h ~ BFh The monitor doesn’t have the input signal. No signal Please check “No picture” in “Troubleshooting”. C0h ~ CFh The monitor caused the problem of the abnormal of option board. Option board abnormal Please contact your supplier. Sample: The following examples are content of Alert Mail that informs the temperature anomaly of monitor. Sample: The following examples are content of test mail by browser.
English-36 Reduced Footprint: Provides the ideal solution for environments with superior image quality\ . Color Control Systems: Allow you to adjust the colors on your screen and customize the color ac\ curacy of your monitor to a variety of standards. OmniColor: Combines Six-axis color control and the sRGB standard. Six-axis color c\ ontrol permits color adjustments via six axes (R, G, B, C, M and Y) rather than through the three axes (R, G and B) previously availab\ le. The sRGB standard provides the monitor with a uniform color profi le. This assures that the colors displayed on the monitor are exactly the sa\ me as on the color printout (with sRGB supporting operating system and sRGB printer)\ . This allows you to adjust the colors on your screen and customise the color accuracy of your monitor to a variety of standar\ ds. sRGB Color Control: A new optimized color management standard which allows for color matching\ on computer displays and other peripherals. The sRGB standard, which is based on a calibrated color space, allows fo\ r optimal color representation and backward compatibility with other common color standards. OSD (On-Screen-Display) Controls: Allow you to quickly and easily adjust all elements of your screen image\ via simple to use on-screen menus. Plug and Play: The Microsoft ® solution with the Windows® operating system facilitates setup and installation by allowing the monitor to send its capabilities (such as screen size and resolutions supported) directly \ to your computer, automatically optimizing display performance. IPM (Intelligent Power Manager) System: Provides innovative power-saving methods that allow the monitor to shift\ to a lower power consumption level when on but not in use, saving two-thirds \ of your monitor energy costs, reducing emissions and lowering the air conditioning costs of the workplace. FullScan Capability: Allows you to use the entire screen area in most resolutions, signifi cantly expanding image size. VESA Standard (FDMIv1) Mounting Interface: Allows you to connect your LCD monitor to any VESA standard (FDMIv1) third party mounting arm or bracket. NEC recommends using mounting interface t\ hat comply with TÜV-GS and/or UL1678 standard in North America. DVI-D: The digital-only subset of DVI ratifi ed by the Digital Display Working Group (DDWG) for digital connections between computers and displays. As a digital-only connector, analog support is not provided for a DVI-D connector. As a DVI-based digital only connection, only a simple adapter is necessary for compatib\ ility between DVI-D and other DVI-based digital connectors such as DFP and P&D. The DVI interface of this display supports HDCP. TILE MATRIX, TILE COMP: Shows one image over multiple screens with accuracy while compensating f\ or bezel width. ZOOM: Expands image size for horizontal and vertical direction. RS-232C daisy chain: You can control the multiple monitors by controller or wireless remote co\ ntroller. Self-diagnosis: If an internal error should occur, a failure state will be indicated. HDCP (High-bandwidth Digital Content Protection): HDCP is a system for preventing illegal copying of video data sent over a Digital Visual Interface (DVI). If you are unable to view material via the DVI \ input, this does not necessarily mean the disp lay is not functioning properly. With the implementation of HDCP, there may be cases in which certain content is protected with HDCP and might not be displayed due to the decision/intention of the HDCP community (Digital Content Protection, LLC). Option board slot: You can use an option board. Please contact your supplier for detailed in\ formation. Features
English-37 EnglishNo picture • The signal cable should be completely connected to the display card/computer. • The display card should be completely seated in its slot. • Check the main Power Switch, it should be in the ON position. • Front Power Switch and computer power switch should be in the ON position. • Check to make sure that a supported mode has been selected on the display card or system being used. (Please consult display card or system manual to change graphics mode.) • Check the monitor and your display card with respect to compatibility and recommended settings. • Check the signal cable connector for bent or pushed-in pins. Power Button does not respond • Unplug the power cord of the monitor from the AC outlet to turn off and reset the monitor. • Check the main Power Switch on the back side of the monitor. Image persistence • Please be aware that LCD Technology may experience a phenomenon known as Image Persistence. Image Persistence occurs when a residual or “ghost” image of a previous image remains visible on the screen. Unlike CRT monitors, LCD monitors’ image persistence is not permanent, but constant images being displayed for a long period of time should be avoided. To alleviate image persistence, turn off the monitor for as long as the previous image was displayed. For example, if an image was on the monitor for one hour and a residual image remains, the monitor should be turned off for one hour to erase the image. NOTE: As with all personal display devices, NEC DISPLAY SOLUTIONS recommends displaying moving images and using a moving screen saver at regular intervals whenever the screen is idle or turning off the monitor when not in use. Image is unstable, unfocused or swimming is apparent • Signal cable should be completely attached to the computer. • Use the OSD Image Adjust controls to focus and adjust display by increasing or decreasing the fi ne adjustment. When the display mode is changed, the OSD Image Adjust settings may need to be re-adjusted. • Check the monitor and your display card with respect to compatibility and recommended signal timings. • If your text is garbled, change the video mode to non- interlace and use 60Hz refresh rate. Image of component signal is greenish • Check to see if the DVD/HD input connector is selected. LED on monitor is not lit (no green or red color can be seen) • Power Switch should be in the ON position and power cord should be connected. • Check the main Power Switch, it should be in the ON position. • Make certain the computer is not in a power-saving mode (touch the keyboard or mouse). • Check to see that the power indicator option in the OSD is set to ON. RED LED on monitor is blinking • A certain failure might have occurred, please contact your nearest authorized NEC DISPLAY SOLUTIONS service facility. • If the monitor is powered off by the inside temperature being higher than the normal operating temperature, a RED LED will blink six times. Power on the display again after confi rming the inside temperature has been reduced to normal operation temperature. Display image is not sized properly • Use the OSD Image Adjust controls to increase or decrease the coarse adjustment. • Check to make sure that a supported mode has been selected on the display card or system being used. (Please consult display card or system manual to change graphics mode.) Selected resolution is not displayed properly • Use OSD Display Mode to enter Information menu and confi rm that the appropriate resolution has been selected. If not, select corresponding option. No Sound • Check to see if audio cable is properly connected. • Check to see if mute is activated. • Check to see if volume is set at minimum. • Check to see if computer supports an audio signal through DisplayPort. If unsure, contact the computer manufacturer. • Check to see if SURROUND is ON. • Check Internal/External speaker switch. Remote Control is not available • Check the Remote Control’s batteries status. • Check if batteries are inserted correctly. • Check if the Remote Control is pointing at the monitor’s remote sensor. • Check the Remote Control Mode status. • The remote control system may not function when direct sunlight or strong illumination strikes the remote control sensor of the LCD monitor, or when there is an object in the path. “SCHEDULE”/“OFF TIMER” function is not working properly • The “SCHEDULE” function will be disabled when the “OFF TIMER” is set. • If the “OFF TIMER” function is enabled and the power to the LCD monitor is turned off when the power supply is interrupted unexpectedly, then the “OFF TIMER” will be reset. Snowy Picture, Poor Sound in TV • Check antenna/cable connection. Use new cable if necessary. Interference in TV • Check components for shielding, move away from monitor if necessary. RS-232C or LAN control is not available • Check RS-232C or LAN cable connection. • Check “CONTROL” setting in “EXTERNAL CONTROL”. • Check the “ID=ALL REPLY” setting in “EXTERNAL CONTROL”. Either light vertical or horizontal stripes may appear, depending on the specifi c display pattern. This is no product fault or degradation. Troubleshooting
English-38 Speci cations - V423 Product Speci cations LCD Module Pixel Pitch: Resolution: Color: Brightness: Contrast Ratio: Viewing Angle: 42”/1067 mm diagonal 0.485 mm 1920 x 1080 Over 16 million colors (depending on video card used) 450 cd/m 2 (Max.), 320 cd/m2 (Factory setting Typ.) @25°C 1300:1 89° (typ) @ CR>10 Frequency Horizontal: Vertical:15.625/15.734 kHz, 31.5 kHz - 91.1 kHz (Analog Input) 31.5 kHz - 91.1 kHz (Digital Input) 50.0 - 85.0 Hz Pixel Clock 25.2 MHz - 162.0 MHz Viewable Size 930.2 x 523.3 mm Input Signal DVI DVI-D 24pin Digital RGB DVI (HDCP) VGA60, SVGA60, XGA60, WXGA60, SXGA60, UXGA60* 1, 1920X1080 (60Hz), 1080p, 1080i DisplayPort DisplayPort Connector Digital RGB DisplayPort Complies with Standard V1.1a, applicable to HDCP V1.3 VGA60, SVGA60, XGA60, WXGA60, SXGA60, UXGA60* 1, 1920x1080 (60 Hz), 1080p, 1080i, 720p@50Hz/60Hz, 576p@50Hz, 480p@60Hz VGA* 215pin Mini D-sub Analog RGB 0.7 Vp-p/75 ohm VGA60, SVGA60, XGA60, WXGA60, SXGA60, UXGA60*1, 1920X1080 (60Hz) Sync Separate: TTL level (Pos./Neg.) Composite sync on Green Video: 0.3 Vp-p Neg. HDMI HDMI Connector Digital YUV Digital RGBHDMI VGA60, SVGA60, XGA60, WXGA60, SXGA60, UXGA60* 1, 1920x1080 (60 Hz), 1080p, 1080i, 720p@50Hz/60Hz, 576p@50Hz, 480p@60Hz, 576i@50Hz, 480i@60Hz DVD/HD* 215pin Mini D-sub Component Y: 1.0 Vp-p/75ohm, Cb/Cr (Pb/Pr): 0.7 Vp-p/75 ohmHDTV/DVD: 1080p, 1080i, 720p@50Hz/60Hz, 576p@50Hz, 480p@60Hz, 576i@50Hz,\ 480i@60Hz VIDEO1 VIDEO2*2BNC 15pin Mini D-sub Composite 1.0 Vp-p/75 ohm NTSC/PAL/SECAM/4.43NTSC/PAL60 S-VIDEO* 215pin Mini D-sub S-VIDEO Y: 1.0 Vp-p/75 ohm C: 0.286 Vp-p/75 ohm (NTSC), 0.3 Vp-p/75 ohm (PAL/SECAM) NTSC/PAL/SECAM/4.43NTSC/PAL60 Output Signal DVI DVI-D 24pin Digital RGB DVI (HDCP) AUDIO AUDIO Input STEREO Mini Jack Analog Audio Stereo L/R 0.5 Vrms HDMI Connector Digital Audio PCM 32, 44.1, 48 KHz (16/20/24bit) DisplayPort Connector Digital Audio PCM 32, 44.1, 48 KHz (16/20/24bit) AUDIO Output RCA (L/R) Analog Audio Stereo L/R 0.5 Vrms Speaker Output External Speaker Jack 15 W + 15 W (8 ohm) Internal Speaker 10 W + 10 W Control RS-232C In: RS-232C Out:LAN:9 Pin D-sub 9 Pin D-sub (with daisy chain) RJ-45 10/100 BASE-T Power Supply 2.4 - 1.0 A @ 100-240V AC, 50/60Hz Operational Environment Temperature* 3: Humidity: Altitude: 0 - 40°C / 32 - 104°F 20 - 80% (without condensation) 0 - 3000 m (Brightness may decrease with altitude) Storage Environment Temperature: Humidity:-20 - 60°C / -4 - 140°F 10 - 90% (without condensation) / 90% - 3.5% x (Temp - 40°C) regarding over 40°C Dimension 972.5 (W) x 565.4 (H) x 68.3 (D) mm / 38.3 (W) x 22.3 (H) x 2.\ 7 (D) inches Weight 16.8 kg (37.0 lbs) VESA compatible mounting interface 300 mm x 300 mm (M6, 4 Holes) Power Management VESA DPM Plug & Play VESA DDC2B, DDC/CI, DisplayPort Accessories Setup manual, Power Cord, Video Signal cable, Remote Control, AA Battery x 2, Clamp x 1, Screw x 1, CD-ROM NOTE: Technical specifi cations are subject to change without notice. *1: Compressed image. *2: Common terminal. *3: When you use option board accessories, please contact your supplier \ for detailed information.