Page 31

En-30
Setting the power on mode
This function sets the input mode and the sound volume
at the time the power is switched on.
Example: Setting the input mode to “VIDEO2”
On “OPTION3 ” menu, select “PWR.ON MODE ”, then
press the MENU/ENTER button.
The “PWR.ON MODE ” screen appears.
On “INPUT ” of “PWR.ON MODE ” menu, select
“VIDEO2”.
The available inputs depend on the setting of input.
SEL. ADJ. RETURNEXIT
PWR. ON MODE
INPUT
VOLUME:   VIDEO2 
:   LAST
Information
 INPUT settings
LAST: Last mode (the input...

Page 32

En-31
ID number setting
When using more than one of these displays, this function
sets ID numbers so that operation of the remote control
does not cause multiple monitors to operate at the same
time.
Example: Setting “2”
On “ID NUMBER” of “OPTION3” menu, select “2”.
SEL. ADJ. RETURN
OPTION 3 3 / 4
      PREVIOUS PAGE
TIMER
PWR. ON MODE
CONTROL LOCK
IR REMOTE
LOOP OUT 
REMOTE ID
ID NUMBER
VIDEO WALL
      NEXT PAGE:   OFF 
:   ON 
:   OFF 
:   ALL
:   2
EXIT
*  To reset back to ALL
Press the...

Page 33

En-32
DISP. MODE
Select the screen mode between two choices (Splitting,
Blanking).
Example: Setting “BLANK”
On “DISP. MODE” of “VIDEO WALL” menu, select
“BLANK”.
SEL. ADJ. RETURN
VIDEO WALL
DIVIDER
POSITION
DISP. MODE
AUTO ID
IMAGE ADJUST
P. ON DELAY
PLE LINK
REPEAT TIMER:   1 
:   BLANK 
:   OFF 
:   OFF 
:   OFF
:   OFF
EXIT
Information
 DISP. MODE settings
SPLIT: Combines enlarged screens and creates multiple
screens.
BLANK: Corrects misalignment of combined screen
portions and creates multiple...

Page 34

En-33
PLE LINK
Use this function to set a uniform brightness for each
display.
Turn on the AUTO ID and set the DIVIDER (at 1, 4 or 9)
before the following operations.
Example: Setting “ON”
On “PLE LINK” of “VIDEO WALL” menu, select “ON”,
then press the MENU/ENTER button.
SEL. ADJ. RETURN
VIDEO WALL
DIVIDER
POSITION
DISP. MODE
AUTO ID
IMAGE ADJUST
P. ON DELAY
PLE LINK
REPEAT TIMER:   1 
:   SPLIT 
:   OFF 
:   OFF 
:   ON
:   OFF
EXIT
Information
 PLE LINK settings
ON: Sets a uniform brightness for each...

Page 35

En-34
Option4 Settings Menu
Set “ADVANCED OSM” to “ON” in the MAIN MENU.
Removing the sub screen area when there is
no input signal detected for the sub picture
This function automatically removes the black frame of
the sub screen when there is no sub screen input signal.
This feature is available only when the picuture-in-picuture
mode is selected.
Example: Setting “DISPLAY” to “FADE”
On “SUB. PICTURE” of “OPTION4” menu, press the
MENU/ENTER button.
The “SUB. PICTURE” screen appears.
Adjust the items....

Page 36

En-35
RGB/PC1
RGB/PC1RGB/PC1
RGB/PC1
RGB/PC1RGB/PC1
Side-by-Side Picture-in-Picture
SELECT/
FREEZE
buttonSELECT/
FREEZE
button
S BY S1
RGB/PC1RGB/PC1
or
S BY S2
Switching the input source quickly
This feature enables quick input selection.
After setting ON, press the CLEAR/SEAMLESS SW
button for quick switching between the two selected input
signals.
Example: Set to switch quickly between RGB1 and
RGB2.
On “SEAMLESS SW” of “OPTION4” menu, select “ON”.
Select “RGB1” and “RGB2”.
SEL. ADJ. RETURN
OPTION 4 4...

Page 37

En-36
Color System Settings Menu
Setting the video signal format
Use these operations to set the color systems of composite
video signals or Y/C input signals.
Example: Setting the color system to “3.58 NTSC”
On the MAIN MENU, select “COLOR SYSTEM”, then press
the MENU/ENTER button.
The “COLOR SYSTEM” screen appears.
On “COLOR SYSTEM”, select “ 3.58NTSC ”.
RETURN
COLOR SYSTEM
COLOR SYSTEM
:   3.58NTSC 
EXITADJ.
Information
 Video signal formats
Different countries use different formats for video...

Page 38

En-37
Application
These specifications cover the communications control of
the plasma monitor by external equipment.
Connections
Connections are made as described below.
Connector on the plasma monitor side: EXTERNAL
CONTROL connector.
Use a crossed (reverse) cable.
Type of connector: D-Sub 9-pin male
15
9
62
34
78
Communication Parameters
(1) Communication system Asynchronous
(2) Interface RS-232C
(3) Baud rate 9600 bps
(4) Data length 8 bits
(5) Parity Odd
(6) Stop bit 1 bit
(7) Communication code Hex...

Page 39

En-38
If the picture quality is poor or there is some other problem, check the adjustments, operations, etc., before requesting service.
Troubleshooting
*1 Overheat protector
If the monitor becomes too hot, the overheat protector will be activated and the monitor will be turned off. If this happens, turn off the power to the monitor
and unplug the power cord. If the room where the monitor is installed is particularly hot, move the monitor to a cooler location and wait for the monitor
to cool for 60...

Page 40

En-39
Table of Signals Supported
Supported resolution (42XM4)
• When the screen mode is NORMAL, each signal is converted to a 768 dots768 lines signal. (Except for *2, 4)
• When the screen mode is FULL, each signal is converted to a 1024 dots768 lines signal.
Computer input signals supported by this system
Screen modeDots  lines
640400
720400
640480
720400
848480
852480*
1
800600
1024768
1152864
1280768
1280768*
9
1280800*9
1280854*9
1280960
1360765
1360768
1376768
12801024...