NEC Plasmasync 61xm4 Users Manual
Here you can view all the pages of manual NEC Plasmasync 61xm4 Users Manual. The NEC manuals for Television are available online for free. You can easily download all the documents as PDF.
Page 31
En-30 Setting the power on mode This function sets the input mode and the sound volume at the time the power is switched on. Example: Setting the input mode to “VIDEO2” On “OPTION3 ” menu, select “PWR.ON MODE ”, then press the MENU/ENTER button. The “PWR.ON MODE ” screen appears. On “INPUT ” of “PWR.ON MODE ” menu, select “VIDEO2”. The available inputs depend on the setting of input. SEL. ADJ. RETURNEXIT PWR. ON MODE INPUT VOLUME: VIDEO2 : LAST Information INPUT settings LAST: Last mode (the input...
Page 32
En-31 ID number setting When using more than one of these displays, this function sets ID numbers so that operation of the remote control does not cause multiple monitors to operate at the same time. Example: Setting “2” On “ID NUMBER” of “OPTION3” menu, select “2”. SEL. ADJ. RETURN OPTION 3 3 / 4 PREVIOUS PAGE TIMER PWR. ON MODE CONTROL LOCK IR REMOTE LOOP OUT REMOTE ID ID NUMBER VIDEO WALL NEXT PAGE: OFF : ON : OFF : ALL : 2 EXIT * To reset back to ALL Press the...
Page 33
En-32 DISP. MODE Select the screen mode between two choices (Splitting, Blanking). Example: Setting “BLANK” On “DISP. MODE” of “VIDEO WALL” menu, select “BLANK”. SEL. ADJ. RETURN VIDEO WALL DIVIDER POSITION DISP. MODE AUTO ID IMAGE ADJUST P. ON DELAY PLE LINK REPEAT TIMER: 1 : BLANK : OFF : OFF : OFF : OFF EXIT Information DISP. MODE settings SPLIT: Combines enlarged screens and creates multiple screens. BLANK: Corrects misalignment of combined screen portions and creates multiple...
Page 34
En-33 PLE LINK Use this function to set a uniform brightness for each display. Turn on the AUTO ID and set the DIVIDER (at 1, 4 or 9) before the following operations. Example: Setting “ON” On “PLE LINK” of “VIDEO WALL” menu, select “ON”, then press the MENU/ENTER button. SEL. ADJ. RETURN VIDEO WALL DIVIDER POSITION DISP. MODE AUTO ID IMAGE ADJUST P. ON DELAY PLE LINK REPEAT TIMER: 1 : SPLIT : OFF : OFF : ON : OFF EXIT Information PLE LINK settings ON: Sets a uniform brightness for each...
Page 35
En-34 Option4 Settings Menu Set “ADVANCED OSM” to “ON” in the MAIN MENU. Removing the sub screen area when there is no input signal detected for the sub picture This function automatically removes the black frame of the sub screen when there is no sub screen input signal. This feature is available only when the picuture-in-picuture mode is selected. Example: Setting “DISPLAY” to “FADE” On “SUB. PICTURE” of “OPTION4” menu, press the MENU/ENTER button. The “SUB. PICTURE” screen appears. Adjust the items....
Page 36
En-35 RGB/PC1 RGB/PC1RGB/PC1 RGB/PC1 RGB/PC1RGB/PC1 Side-by-Side Picture-in-Picture SELECT/ FREEZE buttonSELECT/ FREEZE button S BY S1 RGB/PC1RGB/PC1 or S BY S2 Switching the input source quickly This feature enables quick input selection. After setting ON, press the CLEAR/SEAMLESS SW button for quick switching between the two selected input signals. Example: Set to switch quickly between RGB1 and RGB2. On “SEAMLESS SW” of “OPTION4” menu, select “ON”. Select “RGB1” and “RGB2”. SEL. ADJ. RETURN OPTION 4 4...
Page 37
En-36 Color System Settings Menu Setting the video signal format Use these operations to set the color systems of composite video signals or Y/C input signals. Example: Setting the color system to “3.58 NTSC” On the MAIN MENU, select “COLOR SYSTEM”, then press the MENU/ENTER button. The “COLOR SYSTEM” screen appears. On “COLOR SYSTEM”, select “ 3.58NTSC ”. RETURN COLOR SYSTEM COLOR SYSTEM : 3.58NTSC EXITADJ. Information Video signal formats Different countries use different formats for video...
Page 38
En-37 Application These specifications cover the communications control of the plasma monitor by external equipment. Connections Connections are made as described below. Connector on the plasma monitor side: EXTERNAL CONTROL connector. Use a crossed (reverse) cable. Type of connector: D-Sub 9-pin male 15 9 62 34 78 Communication Parameters (1) Communication system Asynchronous (2) Interface RS-232C (3) Baud rate 9600 bps (4) Data length 8 bits (5) Parity Odd (6) Stop bit 1 bit (7) Communication code Hex...
Page 39
En-38 If the picture quality is poor or there is some other problem, check the adjustments, operations, etc., before requesting service. Troubleshooting *1 Overheat protector If the monitor becomes too hot, the overheat protector will be activated and the monitor will be turned off. If this happens, turn off the power to the monitor and unplug the power cord. If the room where the monitor is installed is particularly hot, move the monitor to a cooler location and wait for the monitor to cool for 60...
Page 40
En-39 Table of Signals Supported Supported resolution (42XM4) • When the screen mode is NORMAL, each signal is converted to a 768 dots768 lines signal. (Except for *2, 4) • When the screen mode is FULL, each signal is converted to a 1024 dots768 lines signal. Computer input signals supported by this system Screen modeDots lines 640400 720400 640480 720400 848480 852480* 1 800600 1024768 1152864 1280768 1280768* 9 1280800*9 1280854*9 1280960 1360765 1360768 1376768 12801024...